home *** CD-ROM | disk | FTP | other *** search
/ The Hacker's Encyclopedia 1998 / hackers_encyclopedia.iso / zines / phrack2 / phrack45.t21 < prev    next >
Encoding:
Text File  |  2003-06-11  |  43.8 KB  |  1,293 lines

  1.                               ==Phrack Magazine==
  2.  
  3.                  Volume Five, Issue Forty-Five, File 21 of 28
  4.  
  5. ****************************************************************************
  6.  
  7.                         The Universal Data Converter
  8.                         ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  9.                            Written by:  Maldoror
  10.                      ~~~ChUrcH oF ThE nOnConFOrMisT~~~
  11.                        ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  12.                      -=[     DELAMO LABS INC       ]=-
  13.                        """""""""""""""""""""""""""""
  14.  
  15. What IS a UDC?!
  16. """""""""""""""
  17.  
  18. The Universal Data converter (UDC), by Applied Computing Devices,
  19. was put into widespread use in 1979.  A UDC is used primarily in
  20. connection with a variety of switches, to log everything the switch does,
  21. and report it to the Central Office in a standard format, allowing the
  22. monitoring and reporting of a variety of different switches by one processor
  23. without the need of understanding each individual switch. This lets the
  24. Telco-Trouble shooters monitor exactly how much traffic is passing
  25. thru a given switch.  Exact number of calls, busys & fraud attempts, are
  26. some examples.  A UDC will give detailed reports of such activity, as
  27. well as hold it in a buffer file which you can view for your own excitement.
  28. The real purpose of this piece of hardware is to buffer data, convert it
  29. to a standard format, and send it on it's merry way to the Central Processor.
  30. Information may be buffered for up to an hour, before being able to be
  31. received by the Central Processor.
  32.  
  33. Which Switches use a UDC?
  34. """""""""""""""""""""""""
  35.  
  36. Well, apparently, nearly all switches owned by a tel-co use a UDC
  37. for their daily reports.  Here is a list of the switches of which I know
  38. may be connected to a converter:
  39.  
  40.  
  41.        At&t Autoplex 100
  42.        ITT/North 1210
  43.        ITT/North NX-1E
  44.        ITT/North "1200" Series (DSS-1)
  45.        GTE GTD-1 (Automatic Electric no. 1 EAX)
  46.        GTE GTD-2 (Automatic Electric no. 2 EAX)
  47.        GTE GTD-3 (Automatic Electric no. 3 EAX)
  48.        GTE GTD-5
  49.        Motorola EMX-250
  50.        NEC NEAX-61
  51.        NEC ND-20S
  52.        Northern Telecom DMS-10
  53.        Northern Telecom DMS-100
  54.        Northern Telecom DMS-200
  55.        Northern Telecom DMS-250
  56.        Northern Telecom DMS-300
  57.        Northern Telecom SL-1  (Seen these around locally)
  58.        Northern Telecom SP-1 PABX
  59.        Stromberg Carlson DCO
  60.        TRW Vidar ITS-4
  61.        TRW Vidar ITS-4/5
  62.        TRW Vidar ITS-5
  63.        Western Electric 5 ESS
  64.        GTE PBX's (GTD-1000, GTD-4600)
  65.  
  66.  
  67.  
  68. General Configurations:
  69. """""""""""""""""""""""
  70.  
  71. A UDC may be configured in several ways.  A UDC consists of up to 6 ports.
  72. Port 0 is usually a dialin line, in which it is connected to a 300/1200
  73. baud modem, so that GTE employees may call to check their switch
  74. information in the field.
  75.  
  76. Port 0 may also be a dedicated line, which is linked to a computer somewhere
  77. important, but if this is the case, you can't have found it anyways, so don't
  78. worry about it. (Unless of course you another indial port possibly 1)
  79.  
  80. Port 2 is usually the line which is hardwired to the data output of the
  81. switch.  This port receives the messages of a switch, analyses the data,
  82. buffers it, and waits until it is told to send the data to the CP, which
  83. may be every time the buffer flips, which of course is configured by hardware.
  84. It is not required that port 2 be the hardwire, although it is just the
  85. most common configuration.
  86.  
  87. Port 1 & 3-7 are also multi-use ports , which may be configured
  88. either for a dedicated line, or a standard phone line, just like port 1.
  89. The difference between this port and port 0 however, is that this port may
  90. also be used to test lines other than the hardware set report line #.
  91. (More later.)
  92.  
  93. NOTE:  ANY of these ports can be completely different depending on the
  94.        setup of the UDC's cards, and which slot they are in...
  95.  
  96.  
  97. The UDC can be configured (though I have never seen it this way) so that any
  98. of the six ports can preform the functions instead of the first three.
  99. If you find a UDC, be sure to check all the ports, and not just three.
  100.  
  101. The general idea of this box of tin is that it will monitor any
  102. switch, collect data into a buffer, and store it until it need be
  103. converted and polled by the SAC.  When the data is sent out, it is sent
  104. in standard UDC format, regardless of the type of switch, therefore any
  105. switch may be monitored by the SAC without having to be converted on
  106. the spot.
  107.  
  108. Yeah Great what the ?#!$ do I do?
  109. """"""""""""""""""""""""""""""""'
  110.  
  111. Scan your local area for all numbers ending in 99xx or 00xx, often
  112. (with GTE anyways) the prefix may be something like 446-9988, or something
  113. outright obvious.  Once you find one, you will know, because you will
  114. get one of two things.  Depending on the configuration of the UDC,
  115. you will either begin getting a dump of data, which will go into detail
  116. about the switch information, or you will get a prompt:
  117.  
  118. *B*>
  119.  
  120. When you receive this prompt, you can make your life easy by typing
  121. HELP in all caps, for a menu of commands, which will seem important at
  122. first (don't fool yourself).
  123.  
  124. Each letter between *'s represents a separate processor (yes even this tin
  125. box has more than one!  These letters will be in the menu
  126. when you type HELP.  To change processors, you will need to hold control
  127. while pressing the letter of the processor you wish to change to.
  128.  
  129. Here is a list of commands for each processor:
  130.  
  131.                         The Basic processor
  132.                         ~~~~~~~~~~~~~~~~~~~
  133.  
  134. *B*> DATE               Display the system Date
  135.  
  136. *B*> DATE mm/dd/yy      Set the date to mm/dd/yy
  137.  
  138. *B*> DIAGNOSTIC         This puts you in debug mode for the UDC's program
  139.                         When typing this command the UDC will respond with
  140.                         "PASSWORD" and will not echo letters.  If the password
  141.                         given is correct, you will get a prompt like this:
  142.                         *B*> DIAG
  143.                         PASSWORD 305      > I enter the good password<
  144.                         DEBUG 1,3         > 1,3 are the ports in use <
  145.                         ?
  146.                         At this point you can reboot the UDC by typing:
  147.                         ? G
  148.                         (ADDR)=1000       > I tell it to jmp to 1000 <
  149.                         Then all hell will break loose...trust me!
  150.                         O.k. well it will look like it anyway...
  151.  
  152.  
  153. *B*> HELP               Duh um, a Menu
  154.  
  155. *B*> RAMPAGE            Test traffic data storage area
  156.  
  157. *B*> SYSTEM             Display system checksums
  158.  
  159. *B*> TIME               Display system time
  160.  
  161. *B*> TIME hh:mm:ss      Set system time (confuse them, set it back then forwd)
  162.  
  163.  
  164.                         The Patch Processor
  165.                         ~~~~~~~~~~~~~~~~~~~
  166.  
  167. *P*> ANSWER n           Take channel 'n' off hook (neato)
  168.  
  169. *P*> BAUD c,bbbb,nnn    Set Channel 'c' Baud rate to 'bbbb', and
  170.                         number of nulls to 'nnn'
  171. *P*> HANGUP n           Put channel 'n' on hook (log out too)
  172.  
  173. *P*> HELP               Help Menus
  174.  
  175. *P*> PATCH n            Patch calling port to port 'n' (Dial out!)
  176.                         It IS possible to patch to modem ports, but I don't
  177.                         recommend it...all GTE numbers have their own COS.
  178.                         (Easy to find you)
  179.  
  180.                         The Plant Queue Processor
  181.                         ~~~~~~~~~~~~~~~~~~~~~~~~~
  182.  
  183. *Q*> ALARM              Display the alarm (error message) string
  184.  
  185. *Q*> ALARM xx..xxx      Set Alarm String (change it back if u want)
  186.  
  187. *Q*> CLEAR              Clear buffer without printing contents (not preferred)
  188.  
  189. *Q*> DUMP               Print and clear contents (destructive, not preferred)
  190.  
  191. *Q*> HELP               Help Menu
  192.  
  193. *Q*> LIMITS             Display buffer alarm threshold
  194.  
  195. *Q*> LIMITS nnnnn       Set buffer alarm threshold to 'nnnn'
  196.  
  197. *Q*> LIST               Display buffer contents (Better than dump)(ok!)
  198.  
  199. *Q*> LIST nnnn          Display buffer contents from 'nnnn' to end
  200.  
  201.  
  202.                         The Report Processor
  203.                         ~~~~~~~~~~~~~~~~~~~~
  204.  
  205. *R*> BACKUP             Transfer a copy of the ROM based table to the
  206.                         editor workspace
  207. *R*> DEFAULT            Make the ROM based table effective (can crash)
  208.  
  209. *R*> EDIT               Engage in edit mode
  210.  
  211.         APPEND          Add line to RMT (Hi there Gen-Tel!)
  212.         DELETE          Delete line from RMT
  213.         END             End edit session
  214.         HELP            List Editor Commands
  215.         LIST            List RMT
  216.         MODIFY          Modify a line in RMT
  217.  
  218. *R*> DOWNLOAD           Download RMT to PROM programmer (ha!)
  219.  
  220. *R*> HELP               More menus
  221.  
  222. *R*> LIST               List effective RMT
  223.  
  224. *R*> LIST N             List RMT without Heading
  225.  
  226. *R*> LIST nnnn          List line 'nnnn' of effective RMT
  227.  
  228. *R*> LIST nnnnN         List line 'nnnn' of effective RMT without heading
  229.  
  230. *R*> LIST nnnn,mmmm     List lines 'nnnn' to 'mmmm' of RMT
  231.  
  232. *R*> LIST nnnn,mmmmN    List lines 'nnnn' to 'mmmm' of RMT without heaading
  233.  
  234. *R*> NEW                Clear the editor workspace
  235.  
  236. *R*> USER               Make RAM based RMT active
  237.  
  238.  
  239.                         The Scanner Processor
  240.                         ~~~~~~~~~~~~~~~~~~~~~
  241.  
  242. *S*> CIRCUIT             Display Status Report
  243.  
  244. *S*> CIRCUIT nnn OFF     Turn off circuit 'nnn' and print Status report
  245.  
  246. *S*> CIRCUIT nnn OFF N   Turn off circuit 'nnn' without report
  247.  
  248. *S*> CIRCUIT nnn,mmm OFF Turn off circuts 'nnn' to 'mmm'
  249.  
  250. *S*> CIRCUIT nnn,mmm OFF N  Turn off 'nnn' to 'mmm' without report
  251.  
  252. *S*> CIRCUIT nnn ON      Turn 'nnn' ON and print report
  253.  
  254. *S*> CIRCUIT nnn ON N    Turn 'nnn' ON without report
  255.  
  256. *S*> CIRCUIT nnn,mmm ON  Turn circuts 'nnn' to 'mmm' on and print status report
  257.  
  258. *S*> CIRCUIT nnn,mmm,ON N   Turn on 'nnn' to 'mmm' but do not print report
  259.  
  260. *S*> REPORT             Display names of disable reports
  261.  
  262. *S*> REPORT report.type OFF     Disable 'report.type' for printing
  263.  
  264. *S*> REPORT report.type ON      Enable  'report.type' for printing
  265.  
  266. *S*> RESTART            Restart scanner interrogation
  267.  
  268. *S*> ROUTE n            Display all future alarm reports on channel 'n'
  269.  
  270. *S*> STOP               Stop scanner interrogation
  271.  
  272. *S*> TEST               Dial the alarm number set on the system optioning
  273.                         board (dip switches on the config board) for
  274.                         communication line testing.
  275.  
  276. *S*> TEST 3,1 nnn nnn nnnn    Dial the indicated number (on port 3) and test
  277.                               the communication lines.
  278.                               If you test with the port you called in on,
  279.                               you will have to hangup and call back for the
  280.                               results. (Port 0)
  281.  
  282.                         The Traffic Processor
  283.                         ~~~~~~~~~~~~~~~~~~~~~
  284.  
  285. *T*> ACTIVE             Display the contents of the active buffer
  286.  
  287. *T*> BANK               Display bank to be polled
  288.  
  289. *T*> BANK n             Set Bank to be polled (bank 'n')
  290.  
  291. *T*> FLIP               Flip the buffers (this MAY cause polling, depending
  292.                         on the hardware (switch) & port configuration)
  293. *T*> HELP               Processor Menus
  294.  
  295. *T*> METERS             Display current meter limits
  296.  
  297. *T*> METERS nnnn        Set upper meter limits
  298.  
  299. *T*> METERS mmmm,nnnn   Set lower and upper meter limits
  300.  
  301. *T*> METERS mmmm,nnnn V Set variable meter limits
  302.  
  303. *T*> METERS mmmm,nnnn F Set fixed meter limits
  304.  
  305. *T*> PASSIVE            Display the contents of a Passive buffer
  306.  
  307. *T*> TRAFFIC            Interrupt or resume traffic after user interaction
  308.                         with channel 1
  309.  
  310.  
  311.  
  312. Standard Control Codes
  313. ~~~~~~~~~~~~~~~~~~~~~
  314.  
  315. ^A      Start of Heading
  316. ^B      Start of Text
  317. ^C      End of Text
  318. ^D      End of transmission
  319. ^E      Enquiry (no not like CBI)
  320. ^F      Acknowledgment
  321. ^G      Bell :)
  322. ^H      Backspace
  323. ^I      Horizontal Tab
  324. ^J      Line feed
  325. ^K      Vertical Tab
  326. ^L      Form Feed
  327. ^M      Carriage return
  328. ^N      Shift out
  329. ^O      Shift in
  330. ^P      Data line escape
  331. ^Q      Device Control 1
  332. ^R      Device Control 2
  333. ^S      Device Control 3
  334. ^T      Device Control 4
  335. ^U      Negative Acknowledgment
  336. ^V      Synchronous Idle
  337. ^W      End of Transmission Block
  338. ^X      Cancel
  339. ^Y      End of Medium
  340. ^Z      Substitute
  341.  
  342.  
  343.  
  344. What is all this?
  345. ~~~~~~~~~~~~~~~~
  346.  
  347. The RMT data is the data transmitted to the UDC by the switch.  This data
  348. is formatted in such a way that it tells the UDC what is happening and what
  349. has already happened since the last buffer flip.  This data is then converted
  350. to a standard format to be transferred to the Central Processor.  For examples
  351. of switch output, refer to the switch example list further in this article.
  352.  
  353. Here is an example of the System Output data, after being translated into
  354. standard format by the UDC:
  355.  
  356.  
  357. The first two lines of the System Output data will contain the values
  358. of the 19 status registers as follows:
  359.  
  360.        0     1     2     3     4     5     6     7     8     9
  361.  
  362. 000  00345 00003 00013 00000 00005 00000 00005 01903 00012 00000
  363. 001  06800 01021 01101 01065 00000 00003 00007 02435 00000 00000
  364.  
  365.        10    11    12    13    14    15    16    17    18    19
  366.  
  367. The registers are as follows:
  368.  
  369. 0       UDC control program number (usually 345, newer versions may be diff.)
  370. 1       UDC control program version (1,3,5,etc.)
  371. 2       Hour at buffer flip (active to passive)
  372. 3       Minute at buffer flip (active to passive)
  373. 4       Number of buffer flips since power on (65535 maximum)
  374. 5       Power interrupt flag (99 if fewer than two intervals have occurred
  375.         since the power interrupt or hard restart; 0 otherwise)
  376. 6       Number of reports in the buffer
  377. 7       Total number of meters in this buffer (including headers)
  378. 8       Hour at buffer flip (passive to active)
  379. 9       Minute at buffer flip (passive to active)
  380. 10-13   Strapping Card signature
  381. 14      Total number of errors since last had reset or power up
  382. 15      Number of soft restarts since last power-up or hard restart
  383. 16      Number of buffer flips since last soft restart
  384. 17      Address of last error which caused a soft restart
  385. 18-19   unused
  386.  
  387.  
  388. When a traffic report is to be sent, the following header will be sent
  389. (in the System Output) to the UDC processor(s) to tell the traffic processor
  390. to begin buffering the report:
  391.  
  392.        0     1     2     3     4     5     6     7     8     9
  393.  
  394. 190  65535 00008 00022 00000 00000 00000 00000 00000 00000 00000
  395. 191  00004 00027 00078 00700 00800 31227 00074 00000 00002 00018
  396. 192  00078 00000 00000 00000 00000 00000 00000 00000 00000 00000
  397.  
  398.        10    11    12    13    14    15    16    17    18    19
  399.  
  400. The registers for the header are as follows:
  401.  
  402. 0       65535 (This signals the beginning of the switch report)
  403. 1       Message type obtained from the 'type' field of the RMT
  404. 2       The number of registers used by the message, including the
  405.         10 registers of this header.
  406. 3-9     unused (00000)
  407.  
  408.  
  409.  
  410. Ok ?!  Now what?!
  411. ~~~~~~~~~~~~~~~~~
  412.  
  413. Well now that I have explained all the commands, the data formats, etc,
  414. of the UDC, you can now check the RMT or TRAFFIC buffers to see exactly
  415. what type of switch you are monitoring.  Here are some examples of the
  416. Data format for the following switches:
  417.  
  418. ************************************************************************
  419. -------------------  AT&T AUTOPLEX 100 SWITCH  -------------------------
  420. ************************************************************************
  421.  
  422.  
  423. Example of RMT data:
  424. ~~~~~~~~~~~~~~~~~~~
  425.  
  426.  
  427. ENTRY  REQUIRED   STRING        NEW     ACTION  TYPE    STARTING      ENDING
  428.         PHASE                   PHASE                   REGISTER      REGISTER
  429. ------------------------------------------------------------------------------
  430. 001     000     /M 00/          001     075     255     65535           65535
  431. 002     001     /BLOCK C/       002     077     001     00020           00169
  432. 003     002     /FINISH/        001     073     255     65535           65535
  433. 004     001     /CELL 001/      001     077     002     00170           00229
  434. 005     001     /CELL 002/      001     077     003     00230           00289
  435. 006     001     /CELL 003/      001     077     004     00290           00349
  436. 007     001     /CELL 005/      001     077     005     00350           00409
  437. 008     001     /CELL 006/      001     077     006     00410           00469
  438. 009     001     /CELL 007/      001     077     007     00470           00529
  439. 010     001     /CELL 008/      001     077     008     00530           00589
  440. 011     001     /CELL 009/      001     077     009     00590           00649
  441. 012     001     /CELL 010/      001     077     010     00650           00709
  442. 013     001     /CELL 011/      001     077     011     00710           00769
  443. 014     001     /CELL 012/      001     077     012     00770           00829
  444. 015     001     /CELL 013/      001     077     013     00830           00889
  445. 016     001     /BLOCK H/       001     077     014     00890           00949
  446. 017     001     /FINISH/        001     073     255     65535           65535
  447.  
  448.  
  449. Example of TRAFFIC report:
  450. ~~~~~~~~~~~~~~~~~~~~~~~~~
  451.  
  452. M 00    3/7/1993        THU     13:00:00
  453.         #068
  454.  
  455.         A 30
  456.  
  457.         BLOCK C 000034   13:00  3/7/1993        12:00   3/7/1993
  458.  
  459. (0)
  460. 000100 000313 000197 000049 000029 000103 000226 000125 000220 000066
  461. (1)
  462. 000180 000291 000238 000123 000050 000154 000326 000146 000074 000089
  463. (2)
  464. 000000 000007 000000 000000 000000 000000 000000 000000 000000 000000
  465. (3)
  466. 000000 000000 000000 000000 000000 000000 000000 000036 000180 000000
  467. (4)
  468. 000023 000023 000366 000000 000000 000000 000000 000000 000000 000000
  469. (5)
  470. .
  471. .
  472. .
  473.   (more data)
  474.  
  475. .
  476. .
  477. (13)
  478. 000000 000000 000000 000000 000000 000000 000000 000000 000000 000000
  479.         FINISH
  480.         03/07/93  13:30:38
  481.         #371
  482.         .
  483.         .
  484.         .
  485.  
  486. M 00    3/7/1993 THU 13:00:00
  487.         #068
  488.  
  489.  
  490. 00 REPT:AMPSTRSF        CELL 001  START 120    STOP 130     03/07   COMPLETE
  491. 000089 000014 000000 000000 000000 000000 000084 000014 000201 000001
  492. 000052 000050 000048 000036 000002 000008 000003 000199 000000 002654
  493. 000000 000031 000000 000360 000000 000000 000000 000036 003728 005170
  494. 000000 004065 003170 000000 003992 000071 000000 000067 000146 000000
  495. 000241 000000 000000 000000 000000 000000 000000 000000 000000 000000
  496. #077
  497.  
  498.         M 00 REPT:RC CENSUS
  499.                 OFFICE RC CHANNEL = REM
  500.                 TRCA OVER 0% FULL
  501.                 RBA OVER 5% FULL
  502.                 RCMDS   MODE = 0
  503.                 #082
  504.  
  505.  
  506.         M 00 REPT:RC SOURCE
  507.  
  508.         SCV=0
  509.         CFV=0
  510.         RCS=0
  511.         DLY=0
  512.         VSS=0
  513.         ACS=0
  514.         CSR=0
  515.         BIS=0
  516.         TRB=0
  517.         FBP=0
  518.         LOG=0
  519.         CR6=0
  520.         #083
  521.         .
  522.         .
  523.         .
  524.         (more)
  525.         .
  526.         .
  527.  
  528. *************************************************************************
  529. ---------------------   ITT/North 1210 Switch  --------------------------
  530. *************************************************************************
  531.  
  532.  
  533.  
  534. Example of RMT data:
  535. ~~~~~~~~~~~~~~~~~~~
  536.  
  537. ACTION  IN LINE  003                    FIXED LOWER: 00000  UPPER: 02039
  538.  
  539. ENTRY  REQUIRED STRING          NEW     ACTION  TYPE  STARTING  ENDING
  540.         PHASE                   PHASE                 REGISTER  REGISTER
  541. -------------------------------------------------------------------------------
  542. 001     000     /:/             001     076     255     65535   65535
  543. 002     001     /TYPE/          002     073     255     65535   65535
  544. 003     002     /2  /           003     077     002     00020   00098
  545. 004     002     /4  /           003     077     004     00100   00319
  546. 005     002     /5  /           003     077     005     00320   00469
  547. 006     002     /16 /           003     077     016     00670   01769
  548. 007     002     /18 /           003     077     018     01770   02040
  549. 008     002     /20 /           003     077     020     00470   00669
  550. 009     003     /END/           000     073     255     65535   65535
  551.  
  552. Example of a TRAFFIC report:
  553. ~~~~~~~~~~~~~~~~~~~~~~~~~~
  554.  
  555. DSS-1  VAR-00 VER-00 PAT=43   ACD
  556. 938 R TRAFF 4703 12/06/93       09:00:00 SBG-B
  557.                                 DATA FROM 1210 SWITCH TO UDC
  558.  
  559. DIAL TONE DELAY
  560. TYPE    CODE    SCAN(SEC)       BRP     START/TIME   LENGTH(MIN) ORDER/DATE
  561.   2      R          10          21(45)   08:00          60       12/16/93
  562.  
  563. THRESHOLD TIME 2.0
  564.  
  565. LSID    DTD  TIME(SEC)  CALLS   DELAY CALLS
  566.  1              .34     60           1
  567.  2              .47     34           0
  568. SYS TOTAL       .43     94           1
  569. END
  570.  
  571. 936 TRAFF  4703 12/06/93        09:45:55        SBG-B
  572. SEPERATIONS
  573.  
  574. TYPE    CODE    SCAN(SEC) BRP   START/TIME      LENGTH(MIN)     ORDER/DATE
  575.   4      R      NONE     10(43Z 12:00            60             12/06/79
  576.  
  577. CNTR*  VALUE  CNTR*  VALUE  CNTR*   VALUE CNTR*  VALUE  CNTR*  VALUE
  578.   1    32      2      65     3       73    4      84     5      64
  579.   6    42      7      84     8       51    9      63     10     69
  580.  
  581. END
  582.  
  583. 9344  TRAFF 4703  12/06/93  09:46:00    CALL COUNT
  584. .
  585. .
  586. (more)
  587. .
  588. .
  589.  
  590.         note: This thing is a beast! If you find one of these call
  591.                 a museum quick!!!
  592.  
  593. *************************************************************************
  594. ---------------         ITT/North NX-1E Switch    -----------------------
  595. *************************************************************************
  596.  
  597.  
  598.  
  599. RMT data example:
  600. """"""""""""""""""
  601.  
  602.  
  603.  
  604. ACTION IN LINE 000                      VARIABLE LOWER: 00000 UPPER: 00019
  605.  
  606. ENTRY   REQUIRED        STRING  NEW     ACTION  TYPE    STARTING  ENDING
  607.         PHASE                   PHASE                   REGISTER  REGISTER
  608. ---------------------------------------------------------------------------
  609.  
  610. 001     000        /:/          001     076     255     65535     65535
  611. 002     001        /DATA TYPE/  001     078     001     65535     65535
  612. 003     001        /END OF/     000     073     255     65535     65535
  613.  
  614.  
  615. Example of a TRAFFIC report:
  616. """"""""""""""""""""""""""""
  617.  
  618. 26 JUNE 86   10:00:00    THT  735    TM GROUPED   DATA DUMP REPORT
  619.  
  620. TIME OF LAST REPORT:    26 JUNE 78    09:00:00
  621.  
  622. DATA TYPE               GROUPED DATA
  623.  
  624. SOTU    572     681
  625.  
  626. SOTP    434     863
  627.  
  628. RSOU    894
  629.  
  630. RSOP    978
  631.  
  632. GTCA    1       1       2       3       4       5       6
  633.  
  634. SLA     0       0       0       0       1       1       1
  635.  
  636. TKTU    631     408     17      358     951     426     324
  637.         436     384     277     462     46      853     956
  638.  
  639. TKTP    543     753     783     34      572     294     815
  640.         426     85      357     392     739     212     142
  641.  
  642. TK2U    584     282     53      19
  643.  
  644. BSWU    27      7
  645.  
  646. QTCU    18
  647.  
  648. END OF GROUPED DATA DUMP
  649.  
  650.  
  651.  
  652. ***************************************************************************
  653. ----------- THE GTE GTD-1 (Automatic Electric No.1 EAX) Switch-------------
  654. ***************************************************************************
  655.  
  656. Example of RMT data:
  657. ~~~~~~~~~~~~~~~~~~~
  658.  
  659.  
  660.  
  661.  
  662. ACTION IN LINE 007                      VARIABLE LOWER: 00000 UPPER: 00079
  663.  
  664. ENTRY   REQUIRED  STRING        NEW     ACTION  TYPE    STARTING   ENDING
  665.         PHASE                   PHASE                   REGISTER   REGISTER
  666. ---------------------------------------------------------------------------
  667.  
  668. 001     000     /HO UR/         000     075     255     65535      65535
  669. 002     000     /MS 19/         001     077     001     00020      00039
  670. 003     001     /MS 19/         001     081     001     00101      65535
  671. 004     001     /COUNTS/        001     073     255     65535      65535
  672. 005     001     /MS 21/         002     077     002     00040      00079
  673. 006     002     /MS 21/         002     081     001     00101      65535
  674. 007     002     /COUNTS/        003     073     255     65535      65535
  675.  
  676.  
  677.  
  678.  
  679.  
  680. Example of TRAFFIC report:
  681. ~~~~~~~~~~~~~~~~~~~~~~~~~
  682.  
  683. I  00  HO UR  1:00:00
  684. R  00  ME RR   9
  685. R  00  MS 19   7 COUNTS GREATER THAN 0
  686. R  00  MS 19   1,01   1152  1,02  1350  1,03  1194
  687. R  00  MS 19   1,04   1378  1,05  1212  1,06  1231
  688. R  00  MS 19   1,07   1099
  689. R  00  MS 21   7 COUNTS GREATER THAN 0
  690. R  00  MS 21   1,01   397  1,02  570  1,03  574
  691. R  00  MS 21   1,04   542  1,05  682  1,06  668
  692. R  00  MS 21   1,07   542
  693. R  00  MS 22   7 COUNTS GREATER THAN 0
  694.  
  695.  
  696. **************************************************************************
  697. --------- THE GTE GTD-2 (Automatic Electric No.2 EAX) Switch -------------
  698. **************************************************************************
  699.  
  700. Example of RMT data:
  701. ~~~~~~~~~~~~~~~~~~~
  702.  
  703. ACTION IN LINE 007                      VARIABLE LOWER: 00000 UPPER: 00079
  704.  
  705. ENTRY  REQUIRED STRING          NEW     ACTION  TYPE   STARTING ENDING
  706.        PHASE                    PHASE                  REGISTER REGISTER
  707. ---------------------------------------------------------------------------
  708. 001     000     /S@/            001     084     255     65535   65535
  709. 002     001     /MPTK/          001     078     001     65535   65535
  710. 003     001     /MPSW/          001     078     002     65535   65535
  711. 004     001     /MPLB/          001     078     003     65535   65535
  712. 005     001     /MPMA/          001     078     004     65535   65535
  713. 006     001     /MPLS/          001     078     005     65535   65535
  714. 007     001     /MPSP/          001     078     006     65535   65535
  715.  
  716.  
  717. Example of TRAFFIC report:
  718. ~~~~~~~~~~~~~~~~~~~~~~~~~
  719.  
  720. S@1900  TDA     MPTK    08-14-86        1900    2000
  721.  
  722.         TRK     ICT     ICT     ICT     OGT     OGT     OGT     PRE
  723.         GRP     USAGE   ATT     HITS    USAGE   ATT     OFL     DIAL
  724.  
  725.         128     0       0       0       31      18      0       0
  726.         129     0       0       0       32      12      0       0
  727.         130     0       0       0       0       0       0       0
  728.         131     0       0       0       486     269     0       0
  729.         132     0       0       0       55      13      0       0
  730.         133     317     143     0       264     108     0       0
  731.         134     0       0       0       1       2       0       0
  732.  
  733. S@1901  TDA     PMSW    08-14-86        1900    2000
  734.  
  735.         SVC     USAGE   ATT     OFL
  736.  
  737.         10      3
  738.         10      3       164     0
  739.         11      17      163     0
  740.         14      302     2523    0
  741.         15      200     2391    0
  742.         16      377     2187    0
  743.         18      84      1171    0
  744.         19      113     1477    0
  745.  
  746.  
  747. **************************************************************************
  748. ------------------- The Motorola EMX-250 Switch --------------------------
  749. **************************************************************************
  750.  
  751.  
  752. Example of RMT data:
  753. ~~~~~~~~~~~~~~~~~~~
  754.  
  755. ACTION IN LINE 003                      VARIABLE  LOWER: 00000 UPPER: 00389
  756.  
  757. ENTRY  REQUIRED    STRING       NEW     ACTION  TYPE    STARTING  ENDING
  758.         PHASE                   PHASE                   REGISTER  REGISTER
  759. ----------------------------------------------------------------------------
  760. 001     000        /TRA21/      001     078     001     65535     65535
  761. 002     001        / /          002     073     255     65535     65535
  762. 003     002        /^M/         000     078     002     65535     65535
  763.  
  764.  
  765.  
  766. Example of TRAFFIC report:
  767. ~~~~~~~~~~~~~~~~~~~~~~~~
  768.  
  769. TRA21   0307    1400    1500
  770. 0369    0000    00
  771. 00129 00045 00178 00127 00000 00000 00000 00000
  772. 00000 00000 00000 00001 00000 00000 00000 00000
  773. 101 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1
  774.  
  775. TRA30 0307 1400 1500
  776. 0000 0000 00
  777. 00000 00000 00000 00000 00000 00000 00000 00000
  778. 00000 00000 00000 00000 00000 00000 00000 00000
  779. 247 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 2134 1
  780.  
  781. TRA31 0307 1400 1500
  782. 0000 0000 00
  783. 00000 00000 00000 00000 00000 00000 00000 00000
  784. 00000 00000 00000 00000 00000 00000 00000 00000
  785. 253 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1
  786.  
  787. TRA32 0307 1400 1500
  788. 00000 00000 00000 00000 00000 00000 00000 00000
  789. 00000 00000 00000 00000 00000 00000 00000 00000
  790. 254 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1
  791.  
  792.  
  793. ************************************************************************
  794. -----------------         NEC ND-20S SWITCH      -----------------------
  795. ************************************************************************
  796.  
  797.  
  798. Example of RMT data
  799. """""""""""""""""""
  800.  
  801.  
  802.  
  803. ENTRY   REQUIRED   STRING       NEW     ACTION  TYPE    STARTING  ENDING
  804.         PHASE                   PHASE                   REGISTER  REGISTER
  805. --------------------------------------------------------------------------
  806.  
  807. 001     000        ///          000     075     255     65535     65535
  808. 002     000        /ORG. CALL/  001     078     001     65535     65535
  809. 003     001        /DUMP END/   000     073     255     65535     65535
  810. 004     000        /SPECIAL DU/ 001     078     002     65536     65535
  811.  
  812.  
  813. Example of TRAFFIC report
  814. ~~~~~~~~~~~~~~~~~~~~~~~~
  815.  
  816.  
  817. 06/21   20:01   CON-TEST        NG
  818. PL:1 0 5 4 5 4 6 PT:1 0 3 1 6 4 2
  819. 06/21   20:02   * TRAFFIC NORMAL DUMP *
  820.  
  821.         COM  ORG. CALL ATTEMPTS (PEG COUNT)
  822.  
  823. 026613  000079  000233   00000 00000 00000 00038
  824. 000000  000114
  825.  
  826.         COM  ORG. CALL COMPLETED (PEG COUNT)
  827.  
  828. 012172  000049  000113  000047
  829.  
  830.         OOH  TER. CALL COMPLETED (PEG COUNT)
  831.  
  832. 034146  000142  000000
  833.  
  834.         OOH  CALLED PARTY BUSY ENCOUNTERED   (PEG COUNT)
  835.  
  836. 003356
  837.  
  838. 06/21   20:04   *NORMAL DUMP END*
  839.  
  840.  
  841. 000000 000000
  842.  
  843.         00H  CALLED OFFICE   (PEG COUNT)
  844.  
  845. 000000 000000 000000 000000 000000 000000 000000 000000
  846.  
  847.         OOH  A-LINK     USAGE PER NW BASIS  (CCS)
  848.  
  849.  
  850. 0733.80  0594.40 0000.00 0000.00
  851.  
  852.         OOH  TRUNK USAGE   (CCS)  OGY
  853.  
  854. 0002.40  0004.20 0009.00 0001.60 0009.60 0002.20 0016.00
  855. 0000.00  0003.00 0000.00 0000.00 0046.80 0000.00 0003.00
  856.  
  857. 06/21   20:22  *SPECIAL DUMP END*
  858.  
  859. 06/21   20:22
  860.  
  861.  
  862. ***************************************************************************
  863. ------------------ Northern Telecom DMS-10 Switch -------------------------
  864. ***************************************************************************
  865.  
  866. Example of RMT data:
  867. ~~~~~~~~~~~~~~~~~~~
  868.  
  869. ACTION IN LINE 011                      VARIABLE LOWER: 00000 UPPER: 00560
  870.  
  871. ENTRY  REQUIRED  STRING         NEW     ACTION  TYPE    STARTING  ENDING
  872.         PHASE                   PHASE                   REGISTER  REGISTER
  873. --------------------------------------------------------------------------
  874. 001     000     /OPM001/        000     072     001     65535     65535
  875. 002     000     /OPM002/        000     078     002     65535     65535
  876. 003     000     /OPM003/        000     078     003     65535     65535
  877. 004     000     /OPM004/        000     078     004     65535     65535
  878. 005     000     /OPM005/        000     078     005     65535     65535
  879. 006     000     /OPM006/        000     078     006     65535     65535
  880. 007     000     /OPM007/        000     078     007     65535     65535
  881. 008     000     /OPM008/        000     078     008     65535     65535
  882. 009     000     /OPM009/        000     078     009     65535     65535
  883. 010     000     /OPM010/        000     078     010     65535     65535
  884. 011     000     /OPM011/        000     078     011     65535     65535
  885. 012     000     /OPM012/        000     078     012     65535     65535
  886. 013     000     /OPM013/        000     078     013     65535     65535
  887.  
  888.  
  889. Example of TRAFFIC report
  890. ~~~~~~~~~~~~~~~~~~~~~~~~
  891.  
  892. OPM001 TRAF HLST MON   08/19/86   15:00:00  HRHR
  893.  
  894.                 PEG     BLK     USE
  895.         ORTM    00635   00000   00978
  896.         OROG    00477   00000   00685
  897.         ORNC    00089
  898.         RVRT    00012
  899.         INTM    00429   00000   00707
  900.         INOG    00000   00000   00000
  901.         INNC    00003
  902.  
  903. OPM002 OSVC HLST MON  11/02/85  15:00:00 HRHR
  904.  
  905.                 PEG
  906.  
  907.         PSIG    00027
  908.         PDTO    00015
  909.         PABN    00092
  910.         FSTR    00168
  911.         DGTC    00599
  912.         DPC     00874
  913.         TOTC    01473
  914.                   %
  915.         DGTS    000.0
  916.         DPS     000.0
  917.         TOTS    000.0
  918.  
  919.  
  920. ************************************************************************
  921. ----------------- Northern Telecom DMS-100 Switch ----------------------
  922. ************************************************************************
  923.  
  924. Example of RMT data
  925. ~~~~~~~~~~~~~~~~~~
  926.  
  927. ACTION IN LINE 004                      VARIABLE LOWER: 00000 UPPER: 01015
  928.  
  929. ENTRY   REQUIRED   STRING       NEW     ACTION  TYPE    STARTING   ENDING
  930.         PHASE                   PHASE                   REGISTER   REGISTER
  931. ---------------------------------------------------------------------------
  932. 001     000        /QWMPR2/     001     075     255     65535      65535
  933. 002     001        /SLOWS/      002     077     001     00020      00999
  934. 003     002        /TRMT2/      003     068     066     65535      65535
  935. 004     002        /ANN^J/      002     068     119     65535      65535
  936. 005     002        /SITE^J/     003     073     255     65535      65535
  937. 006     003        /TRK^J/      004     077     002     01000      04499
  938. 007     004        /KEY/        005     081     019     00027      65535
  939. 008     005        /QFZ^J/      000     077     003     04500      04920
  940.  
  941.  
  942. Example of TRAFFIC report
  943. ~~~~~~~~~~~~~~~~~~~~~~~~
  944.  
  945. CMFLINT OMPR213  AUG13  15:01:09     3684       INFO  CM  REPORT
  946.  
  947. CLASS: NMCTRAFF
  948. START: 1986/08/13  14:00:00  WED; STOP: 1986/08/13   15:00:00 WED;
  949. SLOWSAMPLES:         36;  FASTSAMPLES:          360;
  950.  
  951. CPU
  952.         MTCHINT   TRAPINT   CPUFLT  SYSWINIT SYSCINIT    SYNCLOSS
  953.         MSYLOSSU  SSYLOSSU
  954.  0           0         0       0       0          0           0
  955.              0         0
  956.  
  957. ICO
  958.  
  959.         IOCERR    IOCLKERR   IOCFLT   IOCLKSBU   IOLKMBU  IOCSBU
  960.         IOCMBU
  961.  0           0         0        0      0          0           0
  962.              0
  963.  
  964. CMC
  965.         KEY (CMC_INDEX)
  966.         .
  967.         .
  968.         .
  969.  
  970. ***********************************************************************
  971. ----------------- Northern Telecom DMS-250 ----------------------------
  972. ***********************************************************************
  973.  
  974. Example of RMT data
  975. ~~~~~~~~~~~~~~~~~~
  976.  
  977. ACTION IN LINE 003                      VARIABLE LOWER: 00000 UPPER: 02387
  978.  
  979. ENTRY     REQUIRED    STRING    NEW   ACTION  TYPE STARTING  ENDING
  980.           PHASE                 PHASE              REGISTER  REGISTER
  981. --------------------------------------------------------------------------
  982. 001        000       /QMPR2/    001     072   255  65535     65535
  983. 002        001       /INFO/     002     073   255  65535     65535
  984. 003        002       /SLOWS/    000     078   001  65535     65535
  985.  
  986.  
  987.  
  988. Example of TRAFFIC data
  989. ~~~~~~~~~~~~~~~~~~~~~~
  990.  
  991. QMPR18 AUG28  17:00:43 4000 INFO QM REPORT
  992.         CLASS:SCHOURDC
  993.         START:1984/08/28  16:00:00  TUE; STOP: 1984/08/28 17:00:00 TUE;
  994.         SLOWSAMPLES:       36; FASTSAMPLES
  995.  
  996. TRMT1
  997.         VACT    UNCA    HNPI    UNDN    BLDN    UNIN
  998.         TESS
  999.  
  1000.    0     60       0       0       0       0       0
  1001.           0       0       0
  1002.  
  1003. TRMT2
  1004.  
  1005.         DNTR    CNOT    DCFC    PRSC    GNCT    ATBS
  1006.                 MHLD
  1007.  
  1008.    0      0       0       0       0       0       0
  1009.           0       0
  1010.  
  1011.  
  1012. QMPR220 AUG28 17:30:16  6100 INFO REPORT
  1013.         CLASS: ADHOURC
  1014.         START:1984/08/28        17:00:00 TUE; STOP 1984/08/28   18:00:00 TUE;
  1015.         SLOWSAMPLES:    36;     FASTSAMPLES:    360;
  1016.  
  1017. TRK
  1018.         KEY (COMMON_LANGUAGE_NAME)
  1019.         INFO (QM2TRKINFO)
  1020.           INCATOT PRERTEAB   INFAIL   NATMPT MOVFLATB   GLARE
  1021.           QUTFAIL DEFLCDA    DREU     PREU   TRU        SBU
  1022.           ANSWER  INVAUTH    CONNECT  TANDEM AQF        ANF
  1023.  
  1024.  
  1025. *********************************************************************
  1026. ---------------- Northern Telecom SL-1 Switch ----------------------
  1027. *********************************************************************
  1028.  
  1029. Example of RMT data
  1030. ~~~~~~~~~~~~~~~~~~
  1031.  
  1032. ACTION IN LINE 005 (RAM)        VARIABLE LOWER: 00000 UPPER: 00010
  1033.  
  1034. ENTRY   REQUIRED   STRING       NEW     ACTION  TYPE    STARTING ENDING
  1035.         PHASE                   PHASE                   REGISTER REGISTER
  1036. -------------------------------------------------------------------------
  1037. 001     000     /TFS000/        001     073     255     65535    65535
  1038. 002     001     /19/            002     073     255     65535    65535
  1039. 003     002     / /             000     084     255     65535    65535
  1040. 004     001     /TF/            000     073     255     65535    65535
  1041. 005     002     /TF/            000     073     255     65535    65535
  1042. 006     000     /TFS001/        000     078     001     65535    65535
  1043. 007     000     /TFS002/        000     078     002     65535    65535
  1044. 008     000     /TFS411/        000     078     141     65535    65535
  1045. 009     000     /TFS412/        000     078     142     65535    65535
  1046. 010     000     /TFS999/        000     073     255     65535    65535
  1047.  
  1048.  
  1049. Example of TRAFFIC report
  1050. ~~~~~~~~~~~~~~~~~~~~~~~~
  1051.  
  1052. 001 TFS000
  1053.  
  1054. 13      10      1978
  1055. 10      30      00
  1056.  
  1057. 001 TFS102
  1058.  
  1059. 00      0000157 00100
  1060.  
  1061. 001 TFS102
  1062.  
  1063. 01      0000194 00100
  1064.  
  1065. 001 TFS102
  1066.  
  1067. 02      0000194 00100
  1068.  
  1069. .
  1070. .
  1071. .
  1072.  
  1073. 001     TFS001
  1074.  
  1075. 00      TERM    00000   0000012 00023   00000   0000157 00161
  1076. 01      TERM    00000   0000028 00018   00000   0000256 00157
  1077. 02      TERM    00000   0000015 00019   00000   0000194 00134
  1078. 06      CONF    00000   0000000 00000   00000   0000001 00003
  1079. 07      TDS     00000   0000000 00000   00000   0000000 00000
  1080.  .
  1081.  .
  1082.  .
  1083.  
  1084.  
  1085.  
  1086. ************************************************************************
  1087. ---------------- Northern Telecom SP-1 PABX Switch ---------------------
  1088. ************************************************************************
  1089.  
  1090.  
  1091. Example of RMT data
  1092. ~~~~~~~~~~~~~~~~~~
  1093.  
  1094. ACTION IN LINE 013                      VARIABLE LOWER: 00000 UPPER: 00042
  1095.  
  1096. ENTRY   REQUIRED  STRING        NEW     ACTION  TYPE    STARTING  ENDING
  1097.         PHASE                   PHASE                   REGISTER  REGISTER
  1098. --------------------------------------------------------------------------
  1099. 001     001       /JAN/         002     073     255     65535     65535
  1100. 002     001       /FEB/         002     073     255     65535     65536
  1101. 003     001       /MAR/         002     073     255     65535     65535
  1102. 004     001       /APR/         002     073     255     65535     65535
  1103. 005     001       /MAY/         002     073     255     65535     65535
  1104. 006     001       /JUN/         002     073     255     65535     65535
  1105. 007     001       /JUL/         002     073     255     65535     65535
  1106. 008     001       /AUG/         002     073     255     65535     65535
  1107. 009     001       /SEP/         002     073     255     65535     65535
  1108. 010     001       /OCT/         002     073     255     65535     65535
  1109. 011     001       /NOV/         002     073     255     65535     65535
  1110. 012     001       /DEC/         002     073     255     65535     65535
  1111. 013     002       /19/          000     075     054     65535     65535
  1112. .
  1113. .
  1114. .
  1115.  
  1116. Example of TRAFFIC report
  1117. ~~~~~~~~~~~~~~~~~~~~~~~~
  1118.  
  1119.  
  1120. 0067  OPR  MEA  00315  013077  18 - 200SUS
  1121.  
  1122. LIN#    0       78
  1123.  2      2       8       0       0       32      0       36      0     2  82
  1124.  
  1125. LIN#    1       8
  1126.  0      0       8       0       0       32      0       0       32     2  0
  1127.  
  1128.  
  1129. WED 11 SEPT     1980    112777
  1130.  
  1131. 572     415     23      3       46      160     1992    0
  1132.   0     516      0      0       22        1     2180    0
  1133.  
  1134.         0055  OPR  MEA   045331   112044
  1135.  
  1136. 2420    1713    101     10      327     628     4512    8512    0
  1137.  
  1138.  WED  11 SEPT 1980    1:06:27    1606CLS3
  1139.  
  1140.  
  1141.  .
  1142.  .
  1143.  .
  1144.  
  1145.  
  1146. ***********************************************************************
  1147. --------------- Stromberg Carlson DCO Switch (!!) ---------------------
  1148. ***********************************************************************
  1149.  
  1150. Example of RMT data
  1151. ~~~~~~~~~~~~~~~~~~
  1152.  
  1153. ACTION IN LINE 006                      VARIABLE LOWER: 00000 UPPER: 00837
  1154.  
  1155. ENTRY   REQUIRED  STRING        NEW     ACTION  TYPE    STARTING ENDING
  1156.         PHASE                   PHASE                   REGISTER REGISTER
  1157. --------------------------------------------------------------------------
  1158. 001     000      /COMPLETION/   000     084     255     65535    65535
  1159. 002     000      /ROW/          001     077     001     00100    02039
  1160. 003     001      /END OF TMR/   000     073     255     65535    65535
  1161. 004     001      /***/          002     073     255     65535    65535
  1162. 005     002      /^M/           001     066     001     65535    65535
  1163.  
  1164.  
  1165. Example of a TRAFFIC report
  1166. ~~~~~~~~~~~~~~~~~~~~~~~~~~
  1167.  
  1168. SITE:ACD,INC.           GROUP: 1                BUFFER:ACTIVE
  1169. COLLECTION TIME: 08:00:00       05/01/79
  1170. COMPLETION TIME: 08:01:05       05/01/79
  1171.  
  1172. ROW     ODD3S   ODTNP
  1173. 0       1       2
  1174. 1
  1175.         OLOSZ   OLMAT   ORVEC
  1176. 2       3       2       1
  1177.         OLOTB   OLOTL   OLOTP   OLMDS   OLMBY
  1178. 3       7       2       1       8       3
  1179.  
  1180. 4
  1181.  
  1182. 5
  1183.  
  1184. ...
  1185. .
  1186. .
  1187. .
  1188. .
  1189.  
  1190.  
  1191. ***********************************************************************
  1192. -------------- TRW Vidar ITS 4/5 and ITS 5 Switches -------------------
  1193. ***********************************************************************
  1194.  
  1195.  
  1196.  
  1197. Example of RMT data
  1198. ~~~~~~~~~~~~~~~~~~
  1199.  
  1200.  
  1201. ACTION IN LINE 006              VARIABLE LOWER: 00000 UPPER: 00837
  1202.  
  1203. ENTRY   REQUIRED   STRING       NEW     ACTION  TYPE    STARTING  ENDING
  1204.         PHASE                   PHASE                   REGISTER  REGISTER
  1205. ---------------------------------------------------------------------------
  1206. 001     000     /ITD REPORT/    000     073     255     65535     65535
  1207. 002     000     / TO /          000     072     001     65535     65535
  1208. 003     000     /SYSTEM/        000     078     002     65535     65535
  1209. 004     000     /GRADE/         000     078     004     65535     65535
  1210. 005     000     /SEPAR/         000     073     004     65535     65535
  1211. 006     000     /END/           000     004     255     65535     65535
  1212.  
  1213.  
  1214. Example of TRAFFIC report
  1215. ~~~~~~~~~~~~~~~~~~~~~~~~
  1216.  
  1217. TIMED  ITS REPORT   ADAM FROM 08-18-86  13:01:31 TO 08-18-86 14:00:28
  1218. CLEARING COUNTERS
  1219.  
  1220. GROUP TOTALS
  1221.  
  1222.         NAME    TYPE    ATT     COM     XCS     AVH     OFL
  1223.  
  1224.         LSSO    ORIG    131     93      1671    13      0
  1225.         LSSO    TERM    129     98      1729    13      0
  1226.         LSS1    ORIG    159     111     3093    19      0
  1227.         LSS1    TERM    114     97      2793    25      0
  1228.         LSS2    ORIG
  1229.         .
  1230.         .
  1231.         .
  1232.         .
  1233.  
  1234.  
  1235. *********************************************************************
  1236. ------------- Western Electric ESS 5 Switch -------------------------
  1237. *********************************************************************
  1238.  
  1239. Example of RMT data
  1240. ~~~~~~~~~~~~~~~~~~
  1241.  
  1242. ACTION IN LINE 003                      VARIABLE LOWER: 00000 UPPPER: 00100
  1243.  
  1244. ENTRY   REQUIRED   STRING       NEW     ACTION  TYPE    STARTING ENDING
  1245.         PHASE                   PHASE                   REGISTER REGISTER
  1246. ----------------------------------------------------------------------------
  1247. 001     000     /S570/          001     075     255     65535    65535
  1248. 002     001     /TION 1:/       002     078     001     65535    65535
  1249. 003     002     /TION 3:/       003     078     002     65535    65535
  1250.  
  1251. Example of TRAFFIC report
  1252. ~~~~~~~~~~~~~~~~~~~~~~~~
  1253.  
  1254. S570-108396613 86-05-13  12:01:22  12430
  1255. OP TRFC30 VLD
  1256.   TIME: 12:0:27
  1257.  
  1258. SECTION 1: VALIDITY
  1259.  
  1260. PROC    DATLOS  SCN10   SCN100
  1261. 0       VALID   0       18
  1262. 7       VALID   180     18
  1263. 10      VALID   180     19
  1264. 9       VALID   180     18
  1265. 2       VALID   180     18
  1266. 6       VALID   180     18
  1267. 4       VALID   180     18
  1268. 3       VALID   180     18
  1269. 8       VALID   180     18
  1270. 5       VALID   180     18
  1271. 1       VALID   180     18
  1272. 11      VALID   180     18
  1273.  
  1274.  
  1275. S570-108396613  86-05-13 12:01:24  12431
  1276. OP TRFC30 OFC
  1277.   TIME 12:0:27
  1278.  
  1279. SECTION 3: OFFICE TOTALS
  1280.  
  1281. DPORQ =   46    TTPRQ =  693  DPINRQ =  1226
  1282. MFINRQ=   9577  CDIRR =  58   TCBUSY =  11
  1283.  .
  1284.  .
  1285.  .
  1286.  .
  1287.  .
  1288.  
  1289.  