home *** CD-ROM | disk | FTP | other *** search
Text File | 2003-06-11 | 43.8 KB | 1,293 lines |
- ==Phrack Magazine==
-
- Volume Five, Issue Forty-Five, File 21 of 28
-
- ****************************************************************************
-
- The Universal Data Converter
- ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Written by: Maldoror
- ~~~ChUrcH oF ThE nOnConFOrMisT~~~
- ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- -=[ DELAMO LABS INC ]=-
- """""""""""""""""""""""""""""
-
- What IS a UDC?!
- """""""""""""""
-
- The Universal Data converter (UDC), by Applied Computing Devices,
- was put into widespread use in 1979. A UDC is used primarily in
- connection with a variety of switches, to log everything the switch does,
- and report it to the Central Office in a standard format, allowing the
- monitoring and reporting of a variety of different switches by one processor
- without the need of understanding each individual switch. This lets the
- Telco-Trouble shooters monitor exactly how much traffic is passing
- thru a given switch. Exact number of calls, busys & fraud attempts, are
- some examples. A UDC will give detailed reports of such activity, as
- well as hold it in a buffer file which you can view for your own excitement.
- The real purpose of this piece of hardware is to buffer data, convert it
- to a standard format, and send it on it's merry way to the Central Processor.
- Information may be buffered for up to an hour, before being able to be
- received by the Central Processor.
-
- Which Switches use a UDC?
- """""""""""""""""""""""""
-
- Well, apparently, nearly all switches owned by a tel-co use a UDC
- for their daily reports. Here is a list of the switches of which I know
- may be connected to a converter:
-
-
- At&t Autoplex 100
- ITT/North 1210
- ITT/North NX-1E
- ITT/North "1200" Series (DSS-1)
- GTE GTD-1 (Automatic Electric no. 1 EAX)
- GTE GTD-2 (Automatic Electric no. 2 EAX)
- GTE GTD-3 (Automatic Electric no. 3 EAX)
- GTE GTD-5
- Motorola EMX-250
- NEC NEAX-61
- NEC ND-20S
- Northern Telecom DMS-10
- Northern Telecom DMS-100
- Northern Telecom DMS-200
- Northern Telecom DMS-250
- Northern Telecom DMS-300
- Northern Telecom SL-1 (Seen these around locally)
- Northern Telecom SP-1 PABX
- Stromberg Carlson DCO
- TRW Vidar ITS-4
- TRW Vidar ITS-4/5
- TRW Vidar ITS-5
- Western Electric 5 ESS
- GTE PBX's (GTD-1000, GTD-4600)
-
-
-
- General Configurations:
- """""""""""""""""""""""
-
- A UDC may be configured in several ways. A UDC consists of up to 6 ports.
- Port 0 is usually a dialin line, in which it is connected to a 300/1200
- baud modem, so that GTE employees may call to check their switch
- information in the field.
-
- Port 0 may also be a dedicated line, which is linked to a computer somewhere
- important, but if this is the case, you can't have found it anyways, so don't
- worry about it. (Unless of course you another indial port possibly 1)
-
- Port 2 is usually the line which is hardwired to the data output of the
- switch. This port receives the messages of a switch, analyses the data,
- buffers it, and waits until it is told to send the data to the CP, which
- may be every time the buffer flips, which of course is configured by hardware.
- It is not required that port 2 be the hardwire, although it is just the
- most common configuration.
-
- Port 1 & 3-7 are also multi-use ports , which may be configured
- either for a dedicated line, or a standard phone line, just like port 1.
- The difference between this port and port 0 however, is that this port may
- also be used to test lines other than the hardware set report line #.
- (More later.)
-
- NOTE: ANY of these ports can be completely different depending on the
- setup of the UDC's cards, and which slot they are in...
-
-
- The UDC can be configured (though I have never seen it this way) so that any
- of the six ports can preform the functions instead of the first three.
- If you find a UDC, be sure to check all the ports, and not just three.
-
- The general idea of this box of tin is that it will monitor any
- switch, collect data into a buffer, and store it until it need be
- converted and polled by the SAC. When the data is sent out, it is sent
- in standard UDC format, regardless of the type of switch, therefore any
- switch may be monitored by the SAC without having to be converted on
- the spot.
-
- Yeah Great what the ?#!$ do I do?
- """"""""""""""""""""""""""""""""'
-
- Scan your local area for all numbers ending in 99xx or 00xx, often
- (with GTE anyways) the prefix may be something like 446-9988, or something
- outright obvious. Once you find one, you will know, because you will
- get one of two things. Depending on the configuration of the UDC,
- you will either begin getting a dump of data, which will go into detail
- about the switch information, or you will get a prompt:
-
- *B*>
-
- When you receive this prompt, you can make your life easy by typing
- HELP in all caps, for a menu of commands, which will seem important at
- first (don't fool yourself).
-
- Each letter between *'s represents a separate processor (yes even this tin
- box has more than one! These letters will be in the menu
- when you type HELP. To change processors, you will need to hold control
- while pressing the letter of the processor you wish to change to.
-
- Here is a list of commands for each processor:
-
- The Basic processor
- ~~~~~~~~~~~~~~~~~~~
-
- *B*> DATE Display the system Date
-
- *B*> DATE mm/dd/yy Set the date to mm/dd/yy
-
- *B*> DIAGNOSTIC This puts you in debug mode for the UDC's program
- When typing this command the UDC will respond with
- "PASSWORD" and will not echo letters. If the password
- given is correct, you will get a prompt like this:
- *B*> DIAG
- PASSWORD 305 > I enter the good password<
- DEBUG 1,3 > 1,3 are the ports in use <
- ?
- At this point you can reboot the UDC by typing:
- ? G
- (ADDR)=1000 > I tell it to jmp to 1000 <
- Then all hell will break loose...trust me!
- O.k. well it will look like it anyway...
-
-
- *B*> HELP Duh um, a Menu
-
- *B*> RAMPAGE Test traffic data storage area
-
- *B*> SYSTEM Display system checksums
-
- *B*> TIME Display system time
-
- *B*> TIME hh:mm:ss Set system time (confuse them, set it back then forwd)
-
-
- The Patch Processor
- ~~~~~~~~~~~~~~~~~~~
-
- *P*> ANSWER n Take channel 'n' off hook (neato)
-
- *P*> BAUD c,bbbb,nnn Set Channel 'c' Baud rate to 'bbbb', and
- number of nulls to 'nnn'
- *P*> HANGUP n Put channel 'n' on hook (log out too)
-
- *P*> HELP Help Menus
-
- *P*> PATCH n Patch calling port to port 'n' (Dial out!)
- It IS possible to patch to modem ports, but I don't
- recommend it...all GTE numbers have their own COS.
- (Easy to find you)
-
- The Plant Queue Processor
- ~~~~~~~~~~~~~~~~~~~~~~~~~
-
- *Q*> ALARM Display the alarm (error message) string
-
- *Q*> ALARM xx..xxx Set Alarm String (change it back if u want)
-
- *Q*> CLEAR Clear buffer without printing contents (not preferred)
-
- *Q*> DUMP Print and clear contents (destructive, not preferred)
-
- *Q*> HELP Help Menu
-
- *Q*> LIMITS Display buffer alarm threshold
-
- *Q*> LIMITS nnnnn Set buffer alarm threshold to 'nnnn'
-
- *Q*> LIST Display buffer contents (Better than dump)(ok!)
-
- *Q*> LIST nnnn Display buffer contents from 'nnnn' to end
-
-
- The Report Processor
- ~~~~~~~~~~~~~~~~~~~~
-
- *R*> BACKUP Transfer a copy of the ROM based table to the
- editor workspace
- *R*> DEFAULT Make the ROM based table effective (can crash)
-
- *R*> EDIT Engage in edit mode
-
- APPEND Add line to RMT (Hi there Gen-Tel!)
- DELETE Delete line from RMT
- END End edit session
- HELP List Editor Commands
- LIST List RMT
- MODIFY Modify a line in RMT
-
- *R*> DOWNLOAD Download RMT to PROM programmer (ha!)
-
- *R*> HELP More menus
-
- *R*> LIST List effective RMT
-
- *R*> LIST N List RMT without Heading
-
- *R*> LIST nnnn List line 'nnnn' of effective RMT
-
- *R*> LIST nnnnN List line 'nnnn' of effective RMT without heading
-
- *R*> LIST nnnn,mmmm List lines 'nnnn' to 'mmmm' of RMT
-
- *R*> LIST nnnn,mmmmN List lines 'nnnn' to 'mmmm' of RMT without heaading
-
- *R*> NEW Clear the editor workspace
-
- *R*> USER Make RAM based RMT active
-
-
- The Scanner Processor
- ~~~~~~~~~~~~~~~~~~~~~
-
- *S*> CIRCUIT Display Status Report
-
- *S*> CIRCUIT nnn OFF Turn off circuit 'nnn' and print Status report
-
- *S*> CIRCUIT nnn OFF N Turn off circuit 'nnn' without report
-
- *S*> CIRCUIT nnn,mmm OFF Turn off circuts 'nnn' to 'mmm'
-
- *S*> CIRCUIT nnn,mmm OFF N Turn off 'nnn' to 'mmm' without report
-
- *S*> CIRCUIT nnn ON Turn 'nnn' ON and print report
-
- *S*> CIRCUIT nnn ON N Turn 'nnn' ON without report
-
- *S*> CIRCUIT nnn,mmm ON Turn circuts 'nnn' to 'mmm' on and print status report
-
- *S*> CIRCUIT nnn,mmm,ON N Turn on 'nnn' to 'mmm' but do not print report
-
- *S*> REPORT Display names of disable reports
-
- *S*> REPORT report.type OFF Disable 'report.type' for printing
-
- *S*> REPORT report.type ON Enable 'report.type' for printing
-
- *S*> RESTART Restart scanner interrogation
-
- *S*> ROUTE n Display all future alarm reports on channel 'n'
-
- *S*> STOP Stop scanner interrogation
-
- *S*> TEST Dial the alarm number set on the system optioning
- board (dip switches on the config board) for
- communication line testing.
-
- *S*> TEST 3,1 nnn nnn nnnn Dial the indicated number (on port 3) and test
- the communication lines.
- If you test with the port you called in on,
- you will have to hangup and call back for the
- results. (Port 0)
-
- The Traffic Processor
- ~~~~~~~~~~~~~~~~~~~~~
-
- *T*> ACTIVE Display the contents of the active buffer
-
- *T*> BANK Display bank to be polled
-
- *T*> BANK n Set Bank to be polled (bank 'n')
-
- *T*> FLIP Flip the buffers (this MAY cause polling, depending
- on the hardware (switch) & port configuration)
- *T*> HELP Processor Menus
-
- *T*> METERS Display current meter limits
-
- *T*> METERS nnnn Set upper meter limits
-
- *T*> METERS mmmm,nnnn Set lower and upper meter limits
-
- *T*> METERS mmmm,nnnn V Set variable meter limits
-
- *T*> METERS mmmm,nnnn F Set fixed meter limits
-
- *T*> PASSIVE Display the contents of a Passive buffer
-
- *T*> TRAFFIC Interrupt or resume traffic after user interaction
- with channel 1
-
-
-
- Standard Control Codes
- ~~~~~~~~~~~~~~~~~~~~~
-
- ^A Start of Heading
- ^B Start of Text
- ^C End of Text
- ^D End of transmission
- ^E Enquiry (no not like CBI)
- ^F Acknowledgment
- ^G Bell :)
- ^H Backspace
- ^I Horizontal Tab
- ^J Line feed
- ^K Vertical Tab
- ^L Form Feed
- ^M Carriage return
- ^N Shift out
- ^O Shift in
- ^P Data line escape
- ^Q Device Control 1
- ^R Device Control 2
- ^S Device Control 3
- ^T Device Control 4
- ^U Negative Acknowledgment
- ^V Synchronous Idle
- ^W End of Transmission Block
- ^X Cancel
- ^Y End of Medium
- ^Z Substitute
-
-
-
- What is all this?
- ~~~~~~~~~~~~~~~~
-
- The RMT data is the data transmitted to the UDC by the switch. This data
- is formatted in such a way that it tells the UDC what is happening and what
- has already happened since the last buffer flip. This data is then converted
- to a standard format to be transferred to the Central Processor. For examples
- of switch output, refer to the switch example list further in this article.
-
- Here is an example of the System Output data, after being translated into
- standard format by the UDC:
-
-
- The first two lines of the System Output data will contain the values
- of the 19 status registers as follows:
-
- 0 1 2 3 4 5 6 7 8 9
-
- 000 00345 00003 00013 00000 00005 00000 00005 01903 00012 00000
- 001 06800 01021 01101 01065 00000 00003 00007 02435 00000 00000
-
- 10 11 12 13 14 15 16 17 18 19
-
- The registers are as follows:
-
- 0 UDC control program number (usually 345, newer versions may be diff.)
- 1 UDC control program version (1,3,5,etc.)
- 2 Hour at buffer flip (active to passive)
- 3 Minute at buffer flip (active to passive)
- 4 Number of buffer flips since power on (65535 maximum)
- 5 Power interrupt flag (99 if fewer than two intervals have occurred
- since the power interrupt or hard restart; 0 otherwise)
- 6 Number of reports in the buffer
- 7 Total number of meters in this buffer (including headers)
- 8 Hour at buffer flip (passive to active)
- 9 Minute at buffer flip (passive to active)
- 10-13 Strapping Card signature
- 14 Total number of errors since last had reset or power up
- 15 Number of soft restarts since last power-up or hard restart
- 16 Number of buffer flips since last soft restart
- 17 Address of last error which caused a soft restart
- 18-19 unused
-
-
- When a traffic report is to be sent, the following header will be sent
- (in the System Output) to the UDC processor(s) to tell the traffic processor
- to begin buffering the report:
-
- 0 1 2 3 4 5 6 7 8 9
-
- 190 65535 00008 00022 00000 00000 00000 00000 00000 00000 00000
- 191 00004 00027 00078 00700 00800 31227 00074 00000 00002 00018
- 192 00078 00000 00000 00000 00000 00000 00000 00000 00000 00000
-
- 10 11 12 13 14 15 16 17 18 19
-
- The registers for the header are as follows:
-
- 0 65535 (This signals the beginning of the switch report)
- 1 Message type obtained from the 'type' field of the RMT
- 2 The number of registers used by the message, including the
- 10 registers of this header.
- 3-9 unused (00000)
-
-
-
- Ok ?! Now what?!
- ~~~~~~~~~~~~~~~~~
-
- Well now that I have explained all the commands, the data formats, etc,
- of the UDC, you can now check the RMT or TRAFFIC buffers to see exactly
- what type of switch you are monitoring. Here are some examples of the
- Data format for the following switches:
-
- ************************************************************************
- ------------------- AT&T AUTOPLEX 100 SWITCH -------------------------
- ************************************************************************
-
-
- Example of RMT data:
- ~~~~~~~~~~~~~~~~~~~
-
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ------------------------------------------------------------------------------
- 001 000 /M 00/ 001 075 255 65535 65535
- 002 001 /BLOCK C/ 002 077 001 00020 00169
- 003 002 /FINISH/ 001 073 255 65535 65535
- 004 001 /CELL 001/ 001 077 002 00170 00229
- 005 001 /CELL 002/ 001 077 003 00230 00289
- 006 001 /CELL 003/ 001 077 004 00290 00349
- 007 001 /CELL 005/ 001 077 005 00350 00409
- 008 001 /CELL 006/ 001 077 006 00410 00469
- 009 001 /CELL 007/ 001 077 007 00470 00529
- 010 001 /CELL 008/ 001 077 008 00530 00589
- 011 001 /CELL 009/ 001 077 009 00590 00649
- 012 001 /CELL 010/ 001 077 010 00650 00709
- 013 001 /CELL 011/ 001 077 011 00710 00769
- 014 001 /CELL 012/ 001 077 012 00770 00829
- 015 001 /CELL 013/ 001 077 013 00830 00889
- 016 001 /BLOCK H/ 001 077 014 00890 00949
- 017 001 /FINISH/ 001 073 255 65535 65535
-
-
- Example of TRAFFIC report:
- ~~~~~~~~~~~~~~~~~~~~~~~~~
-
- M 00 3/7/1993 THU 13:00:00
- #068
-
- A 30
-
- BLOCK C 000034 13:00 3/7/1993 12:00 3/7/1993
-
- (0)
- 000100 000313 000197 000049 000029 000103 000226 000125 000220 000066
- (1)
- 000180 000291 000238 000123 000050 000154 000326 000146 000074 000089
- (2)
- 000000 000007 000000 000000 000000 000000 000000 000000 000000 000000
- (3)
- 000000 000000 000000 000000 000000 000000 000000 000036 000180 000000
- (4)
- 000023 000023 000366 000000 000000 000000 000000 000000 000000 000000
- (5)
- .
- .
- .
- (more data)
-
- .
- .
- (13)
- 000000 000000 000000 000000 000000 000000 000000 000000 000000 000000
- FINISH
- 03/07/93 13:30:38
- #371
- .
- .
- .
-
- M 00 3/7/1993 THU 13:00:00
- #068
-
-
- 00 REPT:AMPSTRSF CELL 001 START 120 STOP 130 03/07 COMPLETE
- 000089 000014 000000 000000 000000 000000 000084 000014 000201 000001
- 000052 000050 000048 000036 000002 000008 000003 000199 000000 002654
- 000000 000031 000000 000360 000000 000000 000000 000036 003728 005170
- 000000 004065 003170 000000 003992 000071 000000 000067 000146 000000
- 000241 000000 000000 000000 000000 000000 000000 000000 000000 000000
- #077
-
- M 00 REPT:RC CENSUS
- OFFICE RC CHANNEL = REM
- TRCA OVER 0% FULL
- RBA OVER 5% FULL
- RCMDS MODE = 0
- #082
-
-
- M 00 REPT:RC SOURCE
-
- SCV=0
- CFV=0
- RCS=0
- DLY=0
- VSS=0
- ACS=0
- CSR=0
- BIS=0
- TRB=0
- FBP=0
- LOG=0
- CR6=0
- #083
- .
- .
- .
- (more)
- .
- .
-
- *************************************************************************
- --------------------- ITT/North 1210 Switch --------------------------
- *************************************************************************
-
-
-
- Example of RMT data:
- ~~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 003 FIXED LOWER: 00000 UPPER: 02039
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- -------------------------------------------------------------------------------
- 001 000 /:/ 001 076 255 65535 65535
- 002 001 /TYPE/ 002 073 255 65535 65535
- 003 002 /2 / 003 077 002 00020 00098
- 004 002 /4 / 003 077 004 00100 00319
- 005 002 /5 / 003 077 005 00320 00469
- 006 002 /16 / 003 077 016 00670 01769
- 007 002 /18 / 003 077 018 01770 02040
- 008 002 /20 / 003 077 020 00470 00669
- 009 003 /END/ 000 073 255 65535 65535
-
- Example of a TRAFFIC report:
- ~~~~~~~~~~~~~~~~~~~~~~~~~~
-
- DSS-1 VAR-00 VER-00 PAT=43 ACD
- 938 R TRAFF 4703 12/06/93 09:00:00 SBG-B
- DATA FROM 1210 SWITCH TO UDC
-
- DIAL TONE DELAY
- TYPE CODE SCAN(SEC) BRP START/TIME LENGTH(MIN) ORDER/DATE
- 2 R 10 21(45) 08:00 60 12/16/93
-
- THRESHOLD TIME 2.0
-
- LSID DTD TIME(SEC) CALLS DELAY CALLS
- 1 .34 60 1
- 2 .47 34 0
- SYS TOTAL .43 94 1
- END
-
- 936 TRAFF 4703 12/06/93 09:45:55 SBG-B
- SEPERATIONS
-
- TYPE CODE SCAN(SEC) BRP START/TIME LENGTH(MIN) ORDER/DATE
- 4 R NONE 10(43Z 12:00 60 12/06/79
-
- CNTR* VALUE CNTR* VALUE CNTR* VALUE CNTR* VALUE CNTR* VALUE
- 1 32 2 65 3 73 4 84 5 64
- 6 42 7 84 8 51 9 63 10 69
-
- END
-
- 9344 TRAFF 4703 12/06/93 09:46:00 CALL COUNT
- .
- .
- (more)
- .
- .
-
- note: This thing is a beast! If you find one of these call
- a museum quick!!!
-
- *************************************************************************
- --------------- ITT/North NX-1E Switch -----------------------
- *************************************************************************
-
-
-
- RMT data example:
- """"""""""""""""""
-
-
-
- ACTION IN LINE 000 VARIABLE LOWER: 00000 UPPER: 00019
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ---------------------------------------------------------------------------
-
- 001 000 /:/ 001 076 255 65535 65535
- 002 001 /DATA TYPE/ 001 078 001 65535 65535
- 003 001 /END OF/ 000 073 255 65535 65535
-
-
- Example of a TRAFFIC report:
- """"""""""""""""""""""""""""
-
- 26 JUNE 86 10:00:00 THT 735 TM GROUPED DATA DUMP REPORT
-
- TIME OF LAST REPORT: 26 JUNE 78 09:00:00
-
- DATA TYPE GROUPED DATA
-
- SOTU 572 681
-
- SOTP 434 863
-
- RSOU 894
-
- RSOP 978
-
- GTCA 1 1 2 3 4 5 6
-
- SLA 0 0 0 0 1 1 1
-
- TKTU 631 408 17 358 951 426 324
- 436 384 277 462 46 853 956
-
- TKTP 543 753 783 34 572 294 815
- 426 85 357 392 739 212 142
-
- TK2U 584 282 53 19
-
- BSWU 27 7
-
- QTCU 18
-
- END OF GROUPED DATA DUMP
-
-
-
- ***************************************************************************
- ----------- THE GTE GTD-1 (Automatic Electric No.1 EAX) Switch-------------
- ***************************************************************************
-
- Example of RMT data:
- ~~~~~~~~~~~~~~~~~~~
-
-
-
-
- ACTION IN LINE 007 VARIABLE LOWER: 00000 UPPER: 00079
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ---------------------------------------------------------------------------
-
- 001 000 /HO UR/ 000 075 255 65535 65535
- 002 000 /MS 19/ 001 077 001 00020 00039
- 003 001 /MS 19/ 001 081 001 00101 65535
- 004 001 /COUNTS/ 001 073 255 65535 65535
- 005 001 /MS 21/ 002 077 002 00040 00079
- 006 002 /MS 21/ 002 081 001 00101 65535
- 007 002 /COUNTS/ 003 073 255 65535 65535
-
-
-
-
-
- Example of TRAFFIC report:
- ~~~~~~~~~~~~~~~~~~~~~~~~~
-
- I 00 HO UR 1:00:00
- R 00 ME RR 9
- R 00 MS 19 7 COUNTS GREATER THAN 0
- R 00 MS 19 1,01 1152 1,02 1350 1,03 1194
- R 00 MS 19 1,04 1378 1,05 1212 1,06 1231
- R 00 MS 19 1,07 1099
- R 00 MS 21 7 COUNTS GREATER THAN 0
- R 00 MS 21 1,01 397 1,02 570 1,03 574
- R 00 MS 21 1,04 542 1,05 682 1,06 668
- R 00 MS 21 1,07 542
- R 00 MS 22 7 COUNTS GREATER THAN 0
-
-
- **************************************************************************
- --------- THE GTE GTD-2 (Automatic Electric No.2 EAX) Switch -------------
- **************************************************************************
-
- Example of RMT data:
- ~~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 007 VARIABLE LOWER: 00000 UPPER: 00079
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ---------------------------------------------------------------------------
- 001 000 /S@/ 001 084 255 65535 65535
- 002 001 /MPTK/ 001 078 001 65535 65535
- 003 001 /MPSW/ 001 078 002 65535 65535
- 004 001 /MPLB/ 001 078 003 65535 65535
- 005 001 /MPMA/ 001 078 004 65535 65535
- 006 001 /MPLS/ 001 078 005 65535 65535
- 007 001 /MPSP/ 001 078 006 65535 65535
-
-
- Example of TRAFFIC report:
- ~~~~~~~~~~~~~~~~~~~~~~~~~
-
- S@1900 TDA MPTK 08-14-86 1900 2000
-
- TRK ICT ICT ICT OGT OGT OGT PRE
- GRP USAGE ATT HITS USAGE ATT OFL DIAL
-
- 128 0 0 0 31 18 0 0
- 129 0 0 0 32 12 0 0
- 130 0 0 0 0 0 0 0
- 131 0 0 0 486 269 0 0
- 132 0 0 0 55 13 0 0
- 133 317 143 0 264 108 0 0
- 134 0 0 0 1 2 0 0
-
- S@1901 TDA PMSW 08-14-86 1900 2000
-
- SVC USAGE ATT OFL
-
- 10 3
- 10 3 164 0
- 11 17 163 0
- 14 302 2523 0
- 15 200 2391 0
- 16 377 2187 0
- 18 84 1171 0
- 19 113 1477 0
-
-
- **************************************************************************
- ------------------- The Motorola EMX-250 Switch --------------------------
- **************************************************************************
-
-
- Example of RMT data:
- ~~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPER: 00389
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ----------------------------------------------------------------------------
- 001 000 /TRA21/ 001 078 001 65535 65535
- 002 001 / / 002 073 255 65535 65535
- 003 002 /^M/ 000 078 002 65535 65535
-
-
-
- Example of TRAFFIC report:
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
- TRA21 0307 1400 1500
- 0369 0000 00
- 00129 00045 00178 00127 00000 00000 00000 00000
- 00000 00000 00000 00001 00000 00000 00000 00000
- 101 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1
-
- TRA30 0307 1400 1500
- 0000 0000 00
- 00000 00000 00000 00000 00000 00000 00000 00000
- 00000 00000 00000 00000 00000 00000 00000 00000
- 247 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 2134 1
-
- TRA31 0307 1400 1500
- 0000 0000 00
- 00000 00000 00000 00000 00000 00000 00000 00000
- 00000 00000 00000 00000 00000 00000 00000 00000
- 253 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1
-
- TRA32 0307 1400 1500
- 00000 00000 00000 00000 00000 00000 00000 00000
- 00000 00000 00000 00000 00000 00000 00000 00000
- 254 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1
-
-
- ************************************************************************
- ----------------- NEC ND-20S SWITCH -----------------------
- ************************************************************************
-
-
- Example of RMT data
- """""""""""""""""""
-
-
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- --------------------------------------------------------------------------
-
- 001 000 /// 000 075 255 65535 65535
- 002 000 /ORG. CALL/ 001 078 001 65535 65535
- 003 001 /DUMP END/ 000 073 255 65535 65535
- 004 000 /SPECIAL DU/ 001 078 002 65536 65535
-
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
-
- 06/21 20:01 CON-TEST NG
- PL:1 0 5 4 5 4 6 PT:1 0 3 1 6 4 2
- 06/21 20:02 * TRAFFIC NORMAL DUMP *
-
- COM ORG. CALL ATTEMPTS (PEG COUNT)
-
- 026613 000079 000233 00000 00000 00000 00038
- 000000 000114
-
- COM ORG. CALL COMPLETED (PEG COUNT)
-
- 012172 000049 000113 000047
-
- OOH TER. CALL COMPLETED (PEG COUNT)
-
- 034146 000142 000000
-
- OOH CALLED PARTY BUSY ENCOUNTERED (PEG COUNT)
-
- 003356
-
- 06/21 20:04 *NORMAL DUMP END*
-
-
- 000000 000000
-
- 00H CALLED OFFICE (PEG COUNT)
-
- 000000 000000 000000 000000 000000 000000 000000 000000
-
- OOH A-LINK USAGE PER NW BASIS (CCS)
-
-
- 0733.80 0594.40 0000.00 0000.00
-
- OOH TRUNK USAGE (CCS) OGY
-
- 0002.40 0004.20 0009.00 0001.60 0009.60 0002.20 0016.00
- 0000.00 0003.00 0000.00 0000.00 0046.80 0000.00 0003.00
-
- 06/21 20:22 *SPECIAL DUMP END*
-
- 06/21 20:22
-
-
- ***************************************************************************
- ------------------ Northern Telecom DMS-10 Switch -------------------------
- ***************************************************************************
-
- Example of RMT data:
- ~~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 011 VARIABLE LOWER: 00000 UPPER: 00560
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- --------------------------------------------------------------------------
- 001 000 /OPM001/ 000 072 001 65535 65535
- 002 000 /OPM002/ 000 078 002 65535 65535
- 003 000 /OPM003/ 000 078 003 65535 65535
- 004 000 /OPM004/ 000 078 004 65535 65535
- 005 000 /OPM005/ 000 078 005 65535 65535
- 006 000 /OPM006/ 000 078 006 65535 65535
- 007 000 /OPM007/ 000 078 007 65535 65535
- 008 000 /OPM008/ 000 078 008 65535 65535
- 009 000 /OPM009/ 000 078 009 65535 65535
- 010 000 /OPM010/ 000 078 010 65535 65535
- 011 000 /OPM011/ 000 078 011 65535 65535
- 012 000 /OPM012/ 000 078 012 65535 65535
- 013 000 /OPM013/ 000 078 013 65535 65535
-
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
- OPM001 TRAF HLST MON 08/19/86 15:00:00 HRHR
-
- PEG BLK USE
- ORTM 00635 00000 00978
- OROG 00477 00000 00685
- ORNC 00089
- RVRT 00012
- INTM 00429 00000 00707
- INOG 00000 00000 00000
- INNC 00003
-
- OPM002 OSVC HLST MON 11/02/85 15:00:00 HRHR
-
- PEG
-
- PSIG 00027
- PDTO 00015
- PABN 00092
- FSTR 00168
- DGTC 00599
- DPC 00874
- TOTC 01473
- %
- DGTS 000.0
- DPS 000.0
- TOTS 000.0
-
-
- ************************************************************************
- ----------------- Northern Telecom DMS-100 Switch ----------------------
- ************************************************************************
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 004 VARIABLE LOWER: 00000 UPPER: 01015
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ---------------------------------------------------------------------------
- 001 000 /QWMPR2/ 001 075 255 65535 65535
- 002 001 /SLOWS/ 002 077 001 00020 00999
- 003 002 /TRMT2/ 003 068 066 65535 65535
- 004 002 /ANN^J/ 002 068 119 65535 65535
- 005 002 /SITE^J/ 003 073 255 65535 65535
- 006 003 /TRK^J/ 004 077 002 01000 04499
- 007 004 /KEY/ 005 081 019 00027 65535
- 008 005 /QFZ^J/ 000 077 003 04500 04920
-
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
- CMFLINT OMPR213 AUG13 15:01:09 3684 INFO CM REPORT
-
- CLASS: NMCTRAFF
- START: 1986/08/13 14:00:00 WED; STOP: 1986/08/13 15:00:00 WED;
- SLOWSAMPLES: 36; FASTSAMPLES: 360;
-
- CPU
- MTCHINT TRAPINT CPUFLT SYSWINIT SYSCINIT SYNCLOSS
- MSYLOSSU SSYLOSSU
- 0 0 0 0 0 0 0
- 0 0
-
- ICO
-
- IOCERR IOCLKERR IOCFLT IOCLKSBU IOLKMBU IOCSBU
- IOCMBU
- 0 0 0 0 0 0 0
- 0
-
- CMC
- KEY (CMC_INDEX)
- .
- .
- .
-
- ***********************************************************************
- ----------------- Northern Telecom DMS-250 ----------------------------
- ***********************************************************************
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPER: 02387
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- --------------------------------------------------------------------------
- 001 000 /QMPR2/ 001 072 255 65535 65535
- 002 001 /INFO/ 002 073 255 65535 65535
- 003 002 /SLOWS/ 000 078 001 65535 65535
-
-
-
- Example of TRAFFIC data
- ~~~~~~~~~~~~~~~~~~~~~~
-
- QMPR18 AUG28 17:00:43 4000 INFO QM REPORT
- CLASS:SCHOURDC
- START:1984/08/28 16:00:00 TUE; STOP: 1984/08/28 17:00:00 TUE;
- SLOWSAMPLES: 36; FASTSAMPLES
-
- TRMT1
- VACT UNCA HNPI UNDN BLDN UNIN
- TESS
-
- 0 60 0 0 0 0 0
- 0 0 0
-
- TRMT2
-
- DNTR CNOT DCFC PRSC GNCT ATBS
- MHLD
-
- 0 0 0 0 0 0 0
- 0 0
-
-
- QMPR220 AUG28 17:30:16 6100 INFO REPORT
- CLASS: ADHOURC
- START:1984/08/28 17:00:00 TUE; STOP 1984/08/28 18:00:00 TUE;
- SLOWSAMPLES: 36; FASTSAMPLES: 360;
-
- TRK
- KEY (COMMON_LANGUAGE_NAME)
- INFO (QM2TRKINFO)
- INCATOT PRERTEAB INFAIL NATMPT MOVFLATB GLARE
- QUTFAIL DEFLCDA DREU PREU TRU SBU
- ANSWER INVAUTH CONNECT TANDEM AQF ANF
-
-
- *********************************************************************
- ---------------- Northern Telecom SL-1 Switch ----------------------
- *********************************************************************
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 005 (RAM) VARIABLE LOWER: 00000 UPPER: 00010
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- -------------------------------------------------------------------------
- 001 000 /TFS000/ 001 073 255 65535 65535
- 002 001 /19/ 002 073 255 65535 65535
- 003 002 / / 000 084 255 65535 65535
- 004 001 /TF/ 000 073 255 65535 65535
- 005 002 /TF/ 000 073 255 65535 65535
- 006 000 /TFS001/ 000 078 001 65535 65535
- 007 000 /TFS002/ 000 078 002 65535 65535
- 008 000 /TFS411/ 000 078 141 65535 65535
- 009 000 /TFS412/ 000 078 142 65535 65535
- 010 000 /TFS999/ 000 073 255 65535 65535
-
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
- 001 TFS000
-
- 13 10 1978
- 10 30 00
-
- 001 TFS102
-
- 00 0000157 00100
-
- 001 TFS102
-
- 01 0000194 00100
-
- 001 TFS102
-
- 02 0000194 00100
-
- .
- .
- .
-
- 001 TFS001
-
- 00 TERM 00000 0000012 00023 00000 0000157 00161
- 01 TERM 00000 0000028 00018 00000 0000256 00157
- 02 TERM 00000 0000015 00019 00000 0000194 00134
- 06 CONF 00000 0000000 00000 00000 0000001 00003
- 07 TDS 00000 0000000 00000 00000 0000000 00000
- .
- .
- .
-
-
-
- ************************************************************************
- ---------------- Northern Telecom SP-1 PABX Switch ---------------------
- ************************************************************************
-
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 013 VARIABLE LOWER: 00000 UPPER: 00042
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- --------------------------------------------------------------------------
- 001 001 /JAN/ 002 073 255 65535 65535
- 002 001 /FEB/ 002 073 255 65535 65536
- 003 001 /MAR/ 002 073 255 65535 65535
- 004 001 /APR/ 002 073 255 65535 65535
- 005 001 /MAY/ 002 073 255 65535 65535
- 006 001 /JUN/ 002 073 255 65535 65535
- 007 001 /JUL/ 002 073 255 65535 65535
- 008 001 /AUG/ 002 073 255 65535 65535
- 009 001 /SEP/ 002 073 255 65535 65535
- 010 001 /OCT/ 002 073 255 65535 65535
- 011 001 /NOV/ 002 073 255 65535 65535
- 012 001 /DEC/ 002 073 255 65535 65535
- 013 002 /19/ 000 075 054 65535 65535
- .
- .
- .
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
-
- 0067 OPR MEA 00315 013077 18 - 200SUS
-
- LIN# 0 78
- 2 2 8 0 0 32 0 36 0 2 82
-
- LIN# 1 8
- 0 0 8 0 0 32 0 0 32 2 0
-
-
- WED 11 SEPT 1980 112777
-
- 572 415 23 3 46 160 1992 0
- 0 516 0 0 22 1 2180 0
-
- 0055 OPR MEA 045331 112044
-
- 2420 1713 101 10 327 628 4512 8512 0
-
- WED 11 SEPT 1980 1:06:27 1606CLS3
-
-
- .
- .
- .
-
-
- ***********************************************************************
- --------------- Stromberg Carlson DCO Switch (!!) ---------------------
- ***********************************************************************
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 006 VARIABLE LOWER: 00000 UPPER: 00837
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- --------------------------------------------------------------------------
- 001 000 /COMPLETION/ 000 084 255 65535 65535
- 002 000 /ROW/ 001 077 001 00100 02039
- 003 001 /END OF TMR/ 000 073 255 65535 65535
- 004 001 /***/ 002 073 255 65535 65535
- 005 002 /^M/ 001 066 001 65535 65535
-
-
- Example of a TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~~~
-
- SITE:ACD,INC. GROUP: 1 BUFFER:ACTIVE
- COLLECTION TIME: 08:00:00 05/01/79
- COMPLETION TIME: 08:01:05 05/01/79
-
- ROW ODD3S ODTNP
- 0 1 2
- 1
- OLOSZ OLMAT ORVEC
- 2 3 2 1
- OLOTB OLOTL OLOTP OLMDS OLMBY
- 3 7 2 1 8 3
-
- 4
-
- 5
-
- ...
- .
- .
- .
- .
-
-
- ***********************************************************************
- -------------- TRW Vidar ITS 4/5 and ITS 5 Switches -------------------
- ***********************************************************************
-
-
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
-
- ACTION IN LINE 006 VARIABLE LOWER: 00000 UPPER: 00837
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ---------------------------------------------------------------------------
- 001 000 /ITD REPORT/ 000 073 255 65535 65535
- 002 000 / TO / 000 072 001 65535 65535
- 003 000 /SYSTEM/ 000 078 002 65535 65535
- 004 000 /GRADE/ 000 078 004 65535 65535
- 005 000 /SEPAR/ 000 073 004 65535 65535
- 006 000 /END/ 000 004 255 65535 65535
-
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
- TIMED ITS REPORT ADAM FROM 08-18-86 13:01:31 TO 08-18-86 14:00:28
- CLEARING COUNTERS
-
- GROUP TOTALS
-
- NAME TYPE ATT COM XCS AVH OFL
-
- LSSO ORIG 131 93 1671 13 0
- LSSO TERM 129 98 1729 13 0
- LSS1 ORIG 159 111 3093 19 0
- LSS1 TERM 114 97 2793 25 0
- LSS2 ORIG
- .
- .
- .
- .
-
-
- *********************************************************************
- ------------- Western Electric ESS 5 Switch -------------------------
- *********************************************************************
-
- Example of RMT data
- ~~~~~~~~~~~~~~~~~~
-
- ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPPER: 00100
-
- ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING
- PHASE PHASE REGISTER REGISTER
- ----------------------------------------------------------------------------
- 001 000 /S570/ 001 075 255 65535 65535
- 002 001 /TION 1:/ 002 078 001 65535 65535
- 003 002 /TION 3:/ 003 078 002 65535 65535
-
- Example of TRAFFIC report
- ~~~~~~~~~~~~~~~~~~~~~~~~
-
- S570-108396613 86-05-13 12:01:22 12430
- OP TRFC30 VLD
- TIME: 12:0:27
-
- SECTION 1: VALIDITY
-
- PROC DATLOS SCN10 SCN100
- 0 VALID 0 18
- 7 VALID 180 18
- 10 VALID 180 19
- 9 VALID 180 18
- 2 VALID 180 18
- 6 VALID 180 18
- 4 VALID 180 18
- 3 VALID 180 18
- 8 VALID 180 18
- 5 VALID 180 18
- 1 VALID 180 18
- 11 VALID 180 18
-
-
- S570-108396613 86-05-13 12:01:24 12431
- OP TRFC30 OFC
- TIME 12:0:27
-
- SECTION 3: OFFICE TOTALS
-
- DPORQ = 46 TTPRQ = 693 DPINRQ = 1226
- MFINRQ= 9577 CDIRR = 58 TCBUSY = 11
- .
- .
- .
- .
- .
-
-
-
- ----------------------------------------------------------------------------
-
-