- Information about Northern Telecom's FMT-150B/C/D
- Written by StaTiC
- (statik@free.org)
- ---------------------------------------------------------------------------
-
- Ok, I know someone wrote an article in Phrack about the
- FMT-150B/C/D, but I figured I should write some more. I am not going to
- write the same info that FyberLyte wrote, in fact I recommend you go and
- check it out. It is in Phrack #44-13. This is some stuff I obtained,
- that I figured the rest of the world would be interested in.
-
- Included info: Connecting a FMT-150 to a Rockwell OS-35
- Connecting Environmental Alarms to the FMT-150
- Procomm Script to Perform Configuration of FMT-150
- FMT-150 Configuration Checklist
- Glossary of Terms
-
-
- ------------------------------------------------------------------------------
-
- INSTRUCTIONS FOR X-CONNECTING FMT-150 CUSTOMER OUTPUT TO
- ROCKWELL OS-35 INPUTS
-
- A pin block will be provided at the central office location, in the
- bay equipped with FMT-150 equipment. The pin block will provide
- the termination points for the Rockwell OS-35A and the FMT-150
- customer output alarms. Each pin block will be able to support a
- maximum of 16 FMT-150 systems, see pin block diagram.
-
- Wiring of the FMT-150 customer outputs points and the OS-35A points
- will be done by the vender on the back of the pin block.
-
- Once a FMT-150 system has been certified the certification team
- will be responsible for x-connecting the FMT-150 customer output
- alarm points to the appropriate OS-35A points on the front of the
- pin block. Completion of this x-connecting will allow FMT-150
- system alarms originating either from the CO or the RT to be
- transported via the OS-35A back to the Lightwave and Radio Alarm
- Center.
-
- IMPORTANT, MBT CERTIFICATION TEAMS X-CONNECT ONLY THE FMT-150 THAT
- IS BEING PUT INTO SERVICE AND ONLY AFTER THE ELECTRONICS ARE
- CERTIFIED.
-
- The FMT-150 16 customer outputs are defined as follows:
-
- OUTPUT ALARM OUTPUT ALARM
- ------ ----- ------ -----
- 1 BAY MAJOR 9 MI3 ALARM #3
- 2 BAY MINOR 10 HSA ALARM
- 3 OPT A FAIL 11 HSB ALARM
- 4 OPT B FAIL 12 DS1 GRP FAIL
- 5 STX TX 13 SYSTEM ID CLLI
- 6 STS RX 14 COMM. EQUIP. ALARM
- 7 M13 ALARM #1 15 NODE #1 CO
- 8 M13 ALARM #2 16 NODE #2 REMOTE
-
- The Rockwell OS-35A provides a total of 32 separate alarm points.
- The first 16 points with the exception of point 13 have been
- multiplied on the pin block to provide x-connect points for a total
- of 16 FMT-150 systems, see pin block diagram.
-
- On the pin block x-connect the designated (1 of 16) FMT-150 system
- customer outputs, pins 1-12 and 14-16 to the appropriate OS-35A
- pins 1-12 and 14-16, see pin block diagram.
-
- Pins 17-32 on the pin block going to the OS-35A will be used for
- x-connecting the customer output #13 from each FMT-150 system.
- Customer output #13 provides the system ID for the FMT-150, see pin
- block diagram.
-
- X-CONNECT CUSTOMER OUTPUT #13 FROM FMT-150 SYSTEMS IN
- THIS SEQUENCE
-
- OS-35A FMT-150 System
- ------ --------------
- PIN 17 SYSTEM 1
- PIN 18 SYSTEM 2
- : :
- : :
- PIN 31 SYSTEM 15
- PIN 32 SYSTEM 16
-
- AGAIN, WIRE ONLY THE FMT-150 SYSTEM THAT IS BEING PUT INTO SERVICE
- AND ONLY AFTER CERTIFICATION OF ELECTRONICS HAVE BEEN COMPLETED.
-
- After x-connects have been completed on FMT-150 system that has
- been certified, contact the Alarm Center at (313) 223-9688 and
- verify that all 16 customer output alarm conditions at both the CO
- and RT can be activated and are reporting via the OS-35A back to
- the alarm center.
-
- The Lightwave Alarm Center will monitor the FMT-150 system for a 24
- hour quiet period for alarms. During this 24 hour period if no
- alarms are detected by the Lightwave Alarm Center, the FMT-150 will
- be considered certified for alarming and ready for continual
- monitoring.
-
- If during the 24 hour quiet period the alarm center receives alarms
- from the FMT-150 system, it will not be certified for continual
- monitoring and it will be the responsibility of the MBT
- Certification Teams to resolve those alarms.
-
-
- ----------------------------------------------------------------------------
-
- INSTRUCTIONS FOR CROSS CONNECTING ENVIRONMENTAL ALARMS TO
- THE FMT-150 INPUTS.
-
- Environmental alarms at remote locations may be connected to the
- FMT-150 customer inputs. If more than one system exists, these
- alarms should only be connected to the first. Since many remotes
- will not be equipped with all of these alarms, a checklist has been
- provided on the system acceptance sheets to indicate which have
- been wired. The alarms provided for are Smoke Detector, Sump Pump,
- Open Door, AC Power Fail, HI-LO Temperature, Rectifier Fail, and
- Battery Float. These are wired to pins D8 through E9 on the
- FMT-150 backplane. See Shelf Backplane Detail, attached.
-
- All Customer Inputs are software connected to Customer Output #12.
- They will also bring in Bay Minor (Output #1) or Bay Major (Output
- #2) as appropriate. Inputs #1 (Smoke Detector) and #2 (Sump Pump)
- are latching inputs that can only be cleared by accessing the MCU
- with a VT100 terminal. See Section 321-3211-01, DP 3003, page 2.
-
- FMT-150 systems using external inputs for environmental alarms and
- which use E2 telemetry rather than the OS-35 MUST be provided with
- type NT7H90XH Maintenance Control Units at both ends.
-
- External alarm operation and telemetry if equipped, should be
- verified with the Alarm Center during acceptance.
-
-
-
-
- --------------------------------------------------------------------------
- Procomm Script for Accessing FMT-150B/C/D
-
- ;**********************************************************************
- ;* *
- ;* FMT150.CMD Version 5.00 Dec 18, 1990 *
- ;* Please Destroy all previous versions of this program! *
- ;* *
- ;* NOTE: Procomm is a product of Datastorm Technologies *
- ;**********************************************************************
- ;
- ; The script FMT150.CMD was written to automatically perform
- ; all configuration commands for the Northern Telecom FMT-150
- ; fiber optic multiplexer. Specifically, this script will
- ; complete over 125 configuration commands (performance
- ; threshold, error correction, and alarm outputs) as outlined
- ; in Section 4 of the Michigan Bell Certification Procedure for
- ; the FMT-150. This program is compatible with all
- ; certification requirements for FMT-150 MCU NT7H90XA or MCU
- ; NT7H90XE.
- ;
- ; Requirements:
- ; 1) Toshiba T1000 craft terminal or DOS equivalent.
- ; 2) Proper serial cables and adapters.
- ; 3) Procomm disk with FMT150.CMD file.
- ;
- ; Procedure for use:
- ; 1) Remove disk from drive, then turn on computer. When the DOS
- ; prompt appears insert the PROCOMM disk into disk drive.
- ; Enter the command "A:" + <ENTER>.
- ; 2) Enter the command "FIXPRN" + <ENTER>.
- ; 3) Enter the command "PROCOMM" + <ENTER>.
- ; 4) While holding the <ALT> key down, press the <D> key,
- ; and select FMT-150 from the dialing menu.
- ; 5) Gain access to MCU as normal (press the <ENTER> key 3 times).
- ; 6) Once logged in, reset the MCU to factory default by
- ; entering "M"(aintenance) "R"(eset) "*"(all) + <ENTER>.
- ; It will take approximately three minutes to reconfigure.
- ; 7) Gain access to MCU again as in steps 3) & 4).
- ; 8) Select the script by pressing <ALT><F5> keys simultaneously.
- ; 9) When prompted for command file enter "FMT150" + <ENTER>.
- ; 10) Answer questions and away you go!
- ;
- ; HISTORY: Version 4.00 May 15, 1990 by AQW final release version
- ; HISTORY: Version 4.10 Aug 08, 1990 by JBH mod to use VPRINT to divert
- ; printer into a better bit bucket, and to correct callback #.
- ; HISTORY: Version 4.12 Nov 21, 1990 by EEE to use Customer Inputs
- ; HISTORY: Version 5.00 Dec 18, 1990 by JBH to update documentation
- ;SN051690000
- ;REFNO=5.00
- CLEAR
- PAUSE 1
- ALARM 1
- MESSAGE " "
- MESSAGE " *************************************************"
- MESSAGE " * *"
- MESSAGE " * FMT-150 MCU NT7H90XC\CA CONFIGURATION PROGRAM *"
- MESSAGE " * MCU NT7H90XE\EA CONFIGURATION PROGRAM *"
- MESSAGE " * *"
- MESSAGE " * VERSION 5.00 DEC 18, 1990 *"
- MESSAGE " * *"
- MESSAGE " * MICHIGAN BELL TELEPHONE COMPANY *"
- MESSAGE " * A DIVISION OF AMERITECH *"
- MESSAGE " * *"
- MESSAGE " * *"
- MESSAGE " *************************************************"
- MESSAGE " "
- MESSAGE " "
- MESSAGE " ....TO EXIT THIS PROGRAM AT ANY TIME, PRESS <ESC>...."
- PAUSE 3
- ALARM 1
-
- ;VARIABLE DOCUMENTATION
- ;S0=CLLI A USER INPUT
- ;S1=CLLI B USER INPUT
- ;S2=CLLI LOCAL USER INPUT
- ;S3=YEAR 2 DIGIT USER INPUT
- ;S4=MONTH 2 DIGIT USER INPUT
- ;S5=DAY 2 DIGIT USER INPUT
- ;S6=HOUR 2 DIGIT USER INPUT
- ;S7=MINUTE 2 DIGIT USER INPUT
- ;S8=SYSTEM ID & USER RESPONSE USED TO CONTROL PROGRAM FLOW
- ;S9=SYSTEM NUMBER
-
- LABEL1:
-
- ; note the following statement was superseded in version 4.10 by VPRINT
- ;DOS "MODE LPT1:=COM2:" ; REQUIRED TO TURN PRINTER ERROR OFF
- ; following flushes the "RUB" buffer
- TRANSMIT "^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H"
- CLEAR
- LOCATE 10,2
- MESSAGE "Enter CLLI code for LOCATION A (C.O.) using full 8 or 11 characters:"
- LOCATE 12,2
- GET S0 11 ;CLLI A
- MESSAGE " "
- CLEAR
- LOCATE 10,2
- MESSAGE "Enter CLLI code for LOCATION B (REMOTE) using full 8 or 11 characters:"
- LOCATE 12,2
- GET S1 11 ;CLLI B
- MESSAGE " "
- CLEAR
- LOCATE 10,2
- MESSAGE "Enter CLLI code for YOUR location using full 8 or 11 characters:"
- LOCATE 12,2
- GET S2 11
-
- CLEAR
- LOCATE 8,2
- MESSAGE "Enter system ID without 'MI', for example ALBNMN-JCSNMN."
- LOCATE 10,2
- GET S8 13
- LOCATE 13,2
- MESSAGE "Enter system number, for example 1201 / T3X."
- LOCATE 15,2
- GET S9 15
-
- TRANSMIT "CGNS"
- TRANSMIT "`""
- TRANSMIT S8
- TRANSMIT "`""
- TRANSMIT "!"
-
- CLEAR
- LOCATE 6,2
- MESSAGE "Enter today's date."
- LOCATE 8,2
- MESSAGE "Enter two digit year + <ENTER>"
- LOCATE 8,34
- GET S3 2 ; 2 DIGIT YEAR
- LOCATE 10,2
- MESSAGE "Enter two digit month + <ENTER>. Use 0's if required."
- LOCATE 10,58
- GET S4 2 ; 2 DIGIT MONTH
- LOCATE 12,2
- MESSAGE "Enter two digit day + <ENTER>. Use 0's if required."
- LOCATE 12,56
- GET S5 2 ; 2 DIGIT DAY
- CLEAR
- LOCATE 6,2
- MESSAGE "Enter time."
- LOCATE 8,2
- MESSAGE "Enter two digit hour + <ENTER>. Use 0's if required."
- LOCATE 8,57
- GET S6 2 ; 2 DIGIT HOUR
- LOCATE 10,2
- MESSAGE "Enter two digit minute + <ENTER>. Use 0's if required."
- LOCATE 10,59
- GET S7 2 ; 2 DIGIT MINUTE
- CLEAR
-
- ;SET TIME DP3025
- TRANSMIT "CT"
- TRANSMIT S6
- TRANSMIT " "
- TRANSMIT S7
- TRANSMIT " !"
- PAUSE 1
- KFLUSH
- RFLUSH
- CLEAR
-
- ;PROMPT THE USER TO CHECK INPUTS FOR LOCATIONS
- LOCATE 1,2
- MESSAGE "Please verify the following information."
- LOCATE 4,2
- MESSAGE "LOCATION A CLLI CODE = "
- LOCATE 4,26
- MESSAGE S0
- LOCATE 6,2
- MESSAGE "LOCATION B CLLI CODE = "
- LOCATE 6,26
- MESSAGE S1
- LOCATE 8,2
- MESSAGE "LOCAL LOCATION CLLI CODE ="
- LOCATE 8,29
- MESSAGE S2
- LOCATE 10,2
- MESSAGE "SYSTEM ID = "
- LOCATE 10,17
- MESSAGE S8
- LOCATE 12,2
- MESSAGE "SYSTEM NUMBER = "
- LOCATE 12,21
- MESSAGE S9
- LOCATE 17,2
- MESSAGE "IS INFORMATION CORRECT? Y/N + <ENTER>"
- LOCATE 17,44
- GET S8 1
- SWITCH S8
- CASE "Y"
- ;DO NOTHING
- ENDCASE
- DEFAULT
- GOTO LABEL1 ; JUMP TO TOP AND ENTER INFORMATION AGAIN
- ENDCASE
- ENDSWITCH
- CLEAR
- LOCATE 8,15
- MESSAGE "DO NOT PRESS ANY KEYS UNTIL CONFIGURATION COMPLETE"
- LOCATE 10,15
- MESSAGE "OK...HERE WE GO..."
- ALARM 1
- PAUSE 2
-
- ;SET DATE DP3024
- TRANSMIT "CD"
- TRANSMIT S3
- TRANSMIT " "
- TRANSMIT S4
- TRANSMIT " "
- TRANSMIT S5
- TRANSMIT " !"
- PAUSE 1
-
- ;NAME NODE 1 USING CENTRAL OFFICE CLLI CODE
- TRANSMIT "CGNN1 "
- TRANSMIT "`""
- TRANSMIT S0
- TRANSMIT "`""
- TRANSMIT "!"
-
- ;NAME NODE 2 USING REMOTE CLLI CODE
- TRANSMIT "CGNN2 "
- TRANSMIT "`""
- TRANSMIT S1
- TRANSMIT "`""
- TRANSMIT "!"
-
- ;DEFINE SITE
- TRANSMIT "CGS1 1 2 !"
- ;TRANSMIT "`""
- ;TRANSMIT S0
- ;TRANSMIT "`""
- ;TRANSMIT S1
- ;TRANSMIT " "
- ;TRANSMIT "!"
-
- ;CONFIGURE CUSTOMER OUTPUT POINTS DP3013
- TRANSMIT "CGNO1 "
- TRANSMIT "`"BAY MINOR`""
- TRANSMIT "!"
- TRANSMIT "CGNO2 "
- TRANSMIT "`"BAY MAJOR`""
- TRANSMIT "!"
- TRANSMIT "CGNO3 "
- TRANSMIT "`"OPT A FAIL`""
- TRANSMIT "!"
- TRANSMIT "CGNO4 "
- TRANSMIT "`"OPT B FAIL`""
- TRANSMIT "!"
- TRANSMIT "CGNO5 "
- TRANSMIT "`"STX TX`""
- TRANSMIT "!"
- TRANSMIT "CGNO6 "
- TRANSMIT "`"STX RX`""
- TRANSMIT "!"
- TRANSMIT "CGNO7 "
- TRANSMIT "`"M13 ALARM #1`""
- TRANSMIT "!"
- TRANSMIT "CGNO8 "
- TRANSMIT "`"M13 ALARM #2`""
- TRANSMIT "!"
- TRANSMIT "CGNO9 "
- TRANSMIT "`"M13 ALARM #3`""
- TRANSMIT "!"
- TRANSMIT "CGNO10 "
- TRANSMIT "`"HSA ALARM`""
- TRANSMIT "!"
- TRANSMIT "CGNO11 "
- TRANSMIT "`"HSB ALARM`""
- TRANSMIT "!"
- ;TRANSMIT "CGNO12 "
- ;TRANSMIT "`"DS1 GRP FAIL`""
- ;TRANSMIT "!"
- TRANSMIT "CGNO13 "
- TRANSMIT "`""
- TRANSMIT S9
- TRANSMIT "`""
- TRANSMIT "!"
- TRANSMIT "CGNO14 "
- TRANSMIT "`"COM EQUIP ALRM`""
- TRANSMIT "!"
- TRANSMIT "CGNO15 "
- TRANSMIT "`"NODE #1 CO`""
- TRANSMIT "!"
- TRANSMIT "CGNO16 "
- TRANSMIT "`"NODE #2 REMOTE`""
- TRANSMIT "!"
-
- ;DELETE ALL EXISTING CUSTOMER OUTPUTS
- TRANSMIT "CGO1 D*!"
- TRANSMIT "CGO2 D*!"
- TRANSMIT "CGO3 D*!"
- TRANSMIT "CGO4 D*!"
- TRANSMIT "CGO5 D*!"
- TRANSMIT "CGO6 D*!"
- TRANSMIT "CGO7 D*!"
- TRANSMIT "CGO8 D*!"
- TRANSMIT "CGO9 D*!"
- TRANSMIT "CGO10 D*!"
- TRANSMIT "CGO11 D*!"
- TRANSMIT "CGO12 D*!"
- TRANSMIT "CGO13 D*!"
- TRANSMIT "CGO14 D*!"
- TRANSMIT "CGO15 D*!"
- TRANSMIT "CGO16 D*!"
-
- ;CUSTOMER OUTPUTS 1-2
- TRANSMIT "CGO1 AS1 G100 !"
- TRANSMIT "CGO2 AS1 G120 !"
-
- ;CUSTOMER OUTPUTS 3-9
- TRANSMIT "CGO3 AS1 G107 !"
- TRANSMIT "CGO4 AS1 G108 !"
- TRANSMIT "CGO5 AS1 G101 !"
- TRANSMIT "CGO5 AS1 G102 !"
- TRANSMIT "CGO5 AS1 G103 !"
- TRANSMIT "CGO6 AS1 G104 !"
- TRANSMIT "CGO6 AS1 G105 !"
- TRANSMIT "CGO6 AS1 G106 !"
- TRANSMIT "CGO7 AS1 G109 !"
- TRANSMIT "CGO8 AS1 G110 !"
- TRANSMIT "CGO9 AS1 G111 !"
-
- ;CUSTOMER OUTPUTS 10-11
- TRANSMIT "CGO10 AS1 M1 MH18 !"
- TRANSMIT "CGO10 AS1 M2 MH18 !"
- TRANSMIT "CGO10 AS1 M3 MH18 !"
- TRANSMIT "CGO11 AS1 M1 MH19 !"
- TRANSMIT "CGO11 AS1 M2 MH19 !"
- TRANSMIT "CGO11 AS1 M3 MH19 !"
- ;TRANSMIT "CGO12 AS1 M1 1H2 !"
- ;TRANSMIT "CGO12 AS1 M2 1H2 !"
- ;TRANSMIT "CGO12 AS1 M3 1H2 !"
- ;TRANSMIT "CGO12 AS1 M1 1H3 !"
- ;TRANSMIT "CGO12 AS1 M2 1H3 !"
- ;TRANSMIT "CGO12 AS1 M3 1H3 !"
-
- ;CUSTOMER OUTPUT 13, 14
- TRANSMIT "CGO13 AS1 G100 !"
- TRANSMIT "CGO13 AS1 G120 !"
- TRANSMIT "CGO14 AS1 G112 !"
-
- ;CUSTOMER OUTPUTS 15, 16
- TRANSMIT "CGO15 AN1 G100 !"
- TRANSMIT "CGO15 AN1 G120 !"
- TRANSMIT "CGO16 AN2 G100 !"
- TRANSMIT "CGO16 AN2 G120 !"
-
- ;SET TO AUTOMATIC CONTROL
- TRANSMIT "CGO1 CA!"
- TRANSMIT "CGO2 CA!"
- TRANSMIT "CGO3 CA!"
- TRANSMIT "CGO4 CA!"
- TRANSMIT "CGO5 CA!"
- TRANSMIT "CGO6 CA!"
- TRANSMIT "CGO7 CA!"
- TRANSMIT "CGO8 CA!"
- TRANSMIT "CGO9 CA!"
- TRANSMIT "CGO10 CA!"
- TRANSMIT "CGO11 CA!"
- TRANSMIT "CGO12 CA!"
- TRANSMIT "CGO13 CA!"
- TRANSMIT "CGO14 CA!"
- TRANSMIT "CGO15 CA!"
- TRANSMIT "CGO16 CA!"
- ;
- ;DEFINE CUSTOMER OUTPUT 12
- TRANSMIT "CGO12 D*!"
- TRANSMIT "CGNO12 "
- TRANSMIT "`"EXT ALM`""
- TRANSMIT "!"
- TRANSMIT "CGO12 AN2 G118 !"
- ;also attach to pt 13 for alarm center ID
- TRANSMIT "CGO13 AN2 G118 !"
- ;
- ;DEFINE CUSTOMER INPUTS
- TRANSMIT "CGNI1 "
- TRANSMIT "`"SMOKE DET.`""
- TRANSMIT "!"
- TRANSMIT "CGNI2 "
- TRANSMIT "`"SUMP PUMP`""
- TRANSMIT "!"
- TRANSMIT "CGNI3 "
- TRANSMIT "`"OPEN DOOR`""
- TRANSMIT "!"
- TRANSMIT "CGNI4 "
- TRANSMIT "`"AC PWR FAIL`""
- TRANSMIT "!"
- TRANSMIT "CGNI5 "
- TRANSMIT "`"HI-LO TEMP`""
- TRANSMIT "!"
- TRANSMIT "CGNI6 "
- TRANSMIT "`"RECT. FAIL`""
- TRANSMIT "!"
- TRANSMIT "CGNI7 "
- TRANSMIT "`"BATT FLOAT`""
- TRANSMIT "!"
- ;
- ;ADD CONDITIONS TO CUSTOMER OUTPUT 1
- TRANSMIT "CGO1 AN2 SS5 !"
- TRANSMIT "CGO1 AN2 SS6 !"
- TRANSMIT "CGO1 AN2 SS7 !"
- ;
- ;ADD CONDITIONS TO CUSTOMER OUTPUT 2
- TRANSMIT "CGO2 AN2 SS1 !"
- TRANSMIT "CGO2 AN2 SS2 !"
- TRANSMIT "CGO2 AN2 SS3 !"
- TRANSMIT "CGO2 AN2 SS4 !"
- ;
- ;PER JOE OLSZTYN SWITCHING SYSTEMS STAFF
- ;LEAVE PERFORMANCE MONITORING AT FACTORY DEFAULT
- ;DISABLE BLUE INSERTION FOR POINT TO POINT SYSTEMS
- ;IN A MULTIPOINT SYSTEM BLUE INSERTION SHOULD BE ENABLED.
-
- ;ENABLE ALARM LOGGER
- TRANSMIT "CAD!"
-
- ;DISABLE BLUE INSERTION NODE 1 DP3019
- TRANSMIT "CN1 T1 BE!"
- TRANSMIT "CN1 T2 BE!"
- TRANSMIT "CN1 T3 BE!"
-
- ;ENABLE PARITY CORRECTION NODE 1 DP3020
- TRANSMIT "CN1 T1 PE!"
- TRANSMIT "CN1 T2 PE!"
- TRANSMIT "CN1 T3 PE!"
-
- ;ENABLE RX OVERHEAD NODE 1 DP3021
- TRANSMIT "CN1 T1 RE!"
- TRANSMIT "CN1 T2 RE!"
- TRANSMIT "CN1 T3 RE!"
-
- ;ENABLE TX OVERHEAD NODE 1 DP3022
- TRANSMIT "CN1 T1 TE!"
- TRANSMIT "CN1 T2 TE!"
- TRANSMIT "CN1 T3 TE!"
-
- ;SIGNAL DEGRADE 10E-8 NODE 1 DP3158
- TRANSMIT "CN1 T1 S8!"
- TRANSMIT "CN1 T2 S8!"
- TRANSMIT "CN1 T3 S8!"
-
- ;DISABLE BLUE INSERTION NODE 2 DP3019
- TRANSMIT "CN2 T1 BE!"
- TRANSMIT "CN2 T2 BE!"
- TRANSMIT "CN2 T3 BE!"
-
- ;ENABLE PARITY CORRECTION NODE 2 DP3020
- TRANSMIT "CN2 T1 PE!"
- TRANSMIT "CN2 T2 PE!"
- TRANSMIT "CN2 T3 PE!"
-
- ;ENABLE RX OVERHEAD NODE 2 DP3021
- TRANSMIT "CN2 T1 RE!"
- TRANSMIT "CN2 T2 RE!"
- TRANSMIT "CN2 T3 RE!"
-
- ;ENABLE TX OVERHEAD NODE 2 DP3022
- TRANSMIT "CN2 T1 TE!"
- TRANSMIT "CN2 T2 TE!"
- TRANSMIT "CN2 T3 TE!"
-
- ;SIGNAL DEGRADE 10E-8 NODE 2 DP3158
- TRANSMIT "CN2 T1 S8!"
- TRANSMIT "CN2 T2 S8!"
- TRANSMIT "CN2 T3 S8!"
-
- ;LINE LEARN ALL MULTIPLEXERS BOTH NODES
- TRANSMIT "CN1 M1 L!"
- TRANSMIT "CN1 M2 L!"
- TRANSMIT "CN1 M3 L!"
- TRANSMIT "CN2 M1 L!"
- TRANSMIT "CN2 M2 L!"
- TRANSMIT "CN2 M3 L!"
-
- ;CONFIGURATION IS COMPLETE EXIT THE PROGRAM
- CLEAR
- ALARM 1
- LOCATE 10,20
- MESSAGE "......CONFIGURATION COMPLETE......"
- LOCATE 14,17
- MESSAGE "CONTINUE WITH SECTION 5 OF CERTIFICATION"
- ALARM 2
- PAUSE 5
- EXIT
-
-
- ----------------------------------------------------------------------------
- Glossary of Terms
-
- 4W Four Wire
- ACO Alarm Cut-Off
- ACTV Active (module -- carrying traffic)
- AGC Automatic Gain Control
- AIS Alarm Indication Signal -- indicates an alarm upstream
- AMI Alternate Mark Inversion -- a technique by which the polarity of
- alternate pulses is inverted
- APD Avalanche Photo Diode -- used for detecting pulses of light
- at the receive end of an optical fiber
- AUD Audible alarm
- BDF Battery Distribution Frame
- BER Bit Error Rate
- BIP Bit Interleave Parity
- BPV Bipolar Violation -- signal is not alternating as expected
- CAMMS Centralized Access Maintenance and Monitoring System --
- a bay-mounted shelf with push buttons and an luminescent display,
- which is used to control FMT-150 networks, as well as other
- Northern Telecom transmission equipment
- CDP Centralized Display Panel
- CEV Controlled Environment Vault
- CO Central Office
- CPC Common Product Code -- a Northern Telecom code used to identify
- equipment
- DDD Direct Distance Dialing
- DM-13 Digital Multiplexer which multiplexes between DS-1/1C/2 signals
- and DS-3 signals
- DNA Dynamic Network Architecture
- E2A A serial interface for alarm polling of equipment
- FE Frame Error
- FER Frame Error Rate
- FL Frame Loss
- FLC Frame Loss Counter
- FLS Frame Loss Seconds
- FPD Future Product to be Developed
- Group A multiplexed signal made up of four DS-1s, two DS-1Cs, or
- one Ds-2
- Hub An FMT-150 site which branches one 150 Mb/s signal into two or
- three signals, in different directions, without sacrificing
- OA & M continuity
- LBR Loopback Request
- MCU Maintenance Control Unit
- MM Multimode Optical Fiber
- MSB Most Significant Bit
- Muldem Multiplexer/demultiplexer
- NRZ Non-Return to Zero
- OTT Optical Termination Tray
- PEC Product Engineering Code -- a Norther Telecom code used to identify
- equipment. The preferred code to be used when ordering Northern
- Telecom equipment.
- PER Parity Error Rate
- PES Parity Error Seconds
- RTO Ready To Order
- SCU Service Channel Unit
- SMB Sub-Miniature BNC type connector
- SR Stuff Request
- STX (Pseudo) Synchronous Transport Signal: First Level at
- 49.92 Mb/s (Northern Telecom)
- TBOS Telemetry Byte Oriented System
- VIS Visual Alarm
- WDM Wavelength Division Multiplexing
- XOW Express Orderwire
-
-