  1.                               ==Phrack Magazine==
  2.  
  3.                  Volume Seven, Issue Forty-Eight, File 9 of 18
  4.  
  5. ---------------------------------------------------------------------------
  6.         Information about Northern Telecom's FMT-150B/C/D
  7.                 Written by StaTiC
  8.                 (statik@free.org)
  9. --------------------------------------------------------------------------- 
  10.  
  11.         Ok, I know someone wrote an article in Phrack about the
  12. FMT-150B/C/D, but I figured I should write some more.  I am not going to
  13. write the same info that FyberLyte wrote, in fact I recommend you go and
  14. check it out.  It is in Phrack #44-13.  This is some stuff I obtained,
  15. that I figured the rest of the world would be interested in.
  16.  
  17. Included info:     Connecting a FMT-150 to a Rockwell OS-35
  18.         Connecting Environmental Alarms to the FMT-150
  19.         Procomm Script to Perform Configuration of FMT-150
  20.         FMT-150 Configuration Checklist 
  21.         Glossary of Terms
  22.  
  23.  
  24. ------------------------------------------------------------------------------
  25.  
  26.             INSTRUCTIONS FOR X-CONNECTING FMT-150 CUSTOMER OUTPUT TO
  27.                               ROCKWELL OS-35 INPUTS
  28.  
  29.      A pin block will be provided at the central office location, in the
  30.      bay equipped with FMT-150 equipment.  The pin block will provide
  31.      the termination points for the Rockwell OS-35A and the FMT-150
  32.      customer output alarms. Each pin block will be able to support a
  33.      maximum of 16 FMT-150 systems, see pin block diagram.
  34.  
  35.      Wiring of the FMT-150 customer outputs points and the OS-35A points
  36.      will be done by the vender on the back of the pin block.
  37.  
  38.      Once a FMT-150 system has been certified the certification team
  39.      will be responsible for x-connecting the FMT-150 customer output
  40.      alarm points to the appropriate OS-35A points on the front of the
  41.      pin block. Completion of this x-connecting will allow FMT-150
  42.      system alarms originating either from the CO or the RT to be
  43.      transported via the OS-35A back to the Lightwave and Radio Alarm
  44.      Center.
  45.  
  46.      IMPORTANT, MBT CERTIFICATION TEAMS X-CONNECT ONLY THE FMT-150 THAT
  47.      IS BEING PUT INTO SERVICE AND ONLY AFTER THE ELECTRONICS ARE
  48.      CERTIFIED.
  49.  
  50.      The FMT-150 16 customer outputs are defined as follows:
  51.  
  52.           OUTPUT        ALARM        OUTPUT        ALARM
  53.           ------        -----        ------        -----
  54.             1         BAY MAJOR        9          MI3 ALARM #3
  55.             2         BAY MINOR        10         HSA ALARM
  56.             3         OPT A FAIL       11         HSB ALARM
  57.             4         OPT B FAIL       12         DS1 GRP FAIL
  58.             5         STX TX           13         SYSTEM ID CLLI
  59.             6         STS RX           14         COMM. EQUIP. ALARM
  60.             7         M13 ALARM #1     15         NODE #1 CO
  61.             8         M13 ALARM #2     16         NODE #2 REMOTE
  62.  
  63.      The Rockwell OS-35A provides a total of 32 separate alarm points.
  64.      The first 16 points with the exception of point 13 have been
  65.      multiplied on the pin block to provide x-connect points for a total
  66.      of 16 FMT-150 systems, see pin block diagram.
  67.  
  68.      On the pin block x-connect the designated (1 of 16) FMT-150 system
  69.      customer outputs, pins 1-12 and 14-16 to the appropriate OS-35A
  70.      pins 1-12 and 14-16, see pin block diagram.
  71.  
  72.      Pins 17-32 on the pin block going to the OS-35A will be used for
  73.      x-connecting the customer output #13 from each FMT-150 system.
  74.      Customer output #13 provides the system ID for the FMT-150, see pin
  75.      block diagram.
  76.  
  77.          X-CONNECT CUSTOMER OUTPUT #13 FROM FMT-150 SYSTEMS IN
  78.          THIS SEQUENCE
  79.  
  80.                         OS-35A    FMT-150 System
  81.                         ------    --------------
  82.                         PIN 17      SYSTEM 1
  83.                         PIN 18      SYSTEM 2
  84.                           :            :
  85.                           :            :
  86.                         PIN 31      SYSTEM 15
  87.                         PIN 32      SYSTEM 16
  88.  
  89.      AGAIN, WIRE ONLY THE FMT-150 SYSTEM THAT IS BEING PUT INTO SERVICE
  90.      AND ONLY AFTER CERTIFICATION OF ELECTRONICS HAVE BEEN COMPLETED.
  91.  
  92.      After x-connects have been completed on FMT-150 system that has
  93.      been certified, contact the Alarm Center at (313) 223-9688 and
  94.      verify that all 16 customer output alarm conditions at both the CO
  95.      and RT can be activated and are reporting via the OS-35A back to
  96.      the alarm center.
  97.  
  98.      The Lightwave Alarm Center will monitor the FMT-150 system for a 24
  99.      hour quiet period for alarms.  During this 24 hour period if no
  100.      alarms are detected by the Lightwave Alarm Center, the FMT-150 will
  101.      be considered certified for alarming and ready for continual
  102.      monitoring.
  103.  
  104.      If during the 24 hour quiet period the alarm center receives alarms
  105.      from the FMT-150 system, it will not be certified for continual
  106.      monitoring and it will be the responsibility of the MBT
  107.      Certification Teams to resolve those alarms.
  108.  
  109.  
  110. ----------------------------------------------------------------------------
  111.  
  112.            INSTRUCTIONS FOR CROSS CONNECTING ENVIRONMENTAL ALARMS TO
  113.                                THE FMT-150 INPUTS.
  114.  
  115.      Environmental alarms at remote locations may be connected to the
  116.      FMT-150 customer inputs.  If more than one system exists, these
  117.      alarms should only be connected to the first.  Since many remotes
  118.      will not be equipped with all of these alarms, a checklist has been
  119.      provided on the system acceptance sheets to indicate which have
  120.      been wired.  The alarms provided for are Smoke Detector, Sump Pump,
  121.      Open Door, AC Power Fail, HI-LO Temperature, Rectifier Fail, and
  122.      Battery Float.  These are wired to pins D8 through E9 on the
  123.      FMT-150 backplane.  See Shelf Backplane Detail, attached.
  124.  
  125.      All Customer Inputs are software connected to Customer Output #12.
  126.      They will also bring in Bay Minor (Output #1) or Bay Major (Output
  127.      #2) as appropriate.  Inputs #1 (Smoke Detector) and #2 (Sump Pump)
  128.      are latching inputs that can only be cleared by accessing the MCU
  129.      with a VT100 terminal.  See Section 321-3211-01, DP 3003, page 2.
  130.  
  131.      FMT-150 systems using external inputs for environmental alarms and
  132.      which use E2 telemetry rather than the OS-35 MUST be provided with
  133.      type NT7H90XH Maintenance Control Units at both ends.
  134.  
  135.      External alarm operation and telemetry if equipped, should be
  136.      verified with the Alarm Center during acceptance.
  137.  
  138.  
  139.  
  140.  
  141. --------------------------------------------------------------------------
  142.         Procomm Script for Accessing FMT-150B/C/D
  143.  
  144. ;**********************************************************************
  145. ;*                                                                    *
  146. ;*    FMT150.CMD       Version 5.00        Dec 18, 1990               *
  147. ;*    Please Destroy all previous versions of this program!           *
  148. ;*                                                                    *
  149. ;*    NOTE:  Procomm is a product of Datastorm Technologies           *
  150. ;**********************************************************************
  151. ;         
  152. ;     The  script  FMT150.CMD was written to automatically  perform
  153. ;     all  configuration commands for the Northern Telecom  FMT-150
  154. ;     fiber  optic multiplexer.   Specifically,  this  script  will
  155. ;     complete   over  125  configuration   commands   (performance
  156. ;     threshold,  error correction,  and alarm outputs) as outlined
  157. ;     in Section 4 of the Michigan Bell Certification Procedure for
  158. ;     the   FMT-150.    This  program  is   compatible   with   all
  159. ;     certification requirements for FMT-150  MCU NT7H90XA  or  MCU
  160. ;     NT7H90XE.
  161. ;    
  162. ;     Requirements:
  163. ;     1)  Toshiba T1000 craft terminal or DOS equivalent.
  164. ;     2)  Proper serial cables and adapters.
  165. ;     3)  Procomm disk with FMT150.CMD file.
  166. ;    
  167. ;     Procedure for use:
  168. ;     1)  Remove disk from drive, then turn on computer.  When the DOS 
  169. ;         prompt appears insert the PROCOMM disk into disk drive.  
  170. ;         Enter the command "A:" + <ENTER>.
  171. ;     2)  Enter the command "FIXPRN" + <ENTER>.
  172. ;     3)  Enter the command "PROCOMM" + <ENTER>.
  173. ;     4)  While holding the <ALT> key down, press the <D> key, 
  174. ;         and select FMT-150 from the dialing menu.
  175. ;     5)  Gain access to MCU as normal (press the <ENTER> key 3 times).
  176. ;     6)  Once logged in, reset the MCU to factory default by
  177. ;         entering "M"(aintenance) "R"(eset) "*"(all) + <ENTER>.
  178. ;         It will take approximately three minutes to reconfigure.
  179. ;     7)  Gain access to MCU again as in steps 3) & 4).
  180. ;     8)  Select the script by pressing <ALT><F5> keys simultaneously.
  181. ;     9)  When prompted for command file enter "FMT150" + <ENTER>.
  182. ;     10) Answer questions and away you go!
  183. ;
  184. ; HISTORY: Version 4.00 May 15, 1990 by AQW final release version
  185. ; HISTORY: Version 4.10 Aug 08, 1990 by JBH mod to use VPRINT to divert
  186. ;          printer into a better bit bucket, and to correct callback #.
  187. ; HISTORY: Version 4.12 Nov 21, 1990 by EEE to use Customer Inputs
  188. ; HISTORY: Version 5.00 Dec 18, 1990 by JBH to update documentation
  189. ;SN051690000
  190. ;REFNO=5.00
  191. CLEAR
  192. PAUSE 1
  193. ALARM 1
  194. MESSAGE " "
  195. MESSAGE "            *************************************************"
  196. MESSAGE "            *                                               *"
  197. MESSAGE "            * FMT-150 MCU NT7H90XC\CA CONFIGURATION PROGRAM *"
  198. MESSAGE "            *         MCU NT7H90XE\EA CONFIGURATION PROGRAM *"
  199. MESSAGE "            *                                               *"
  200. MESSAGE "            *      VERSION 5.00         DEC 18, 1990        *"
  201. MESSAGE "            *                                               *"
  202. MESSAGE "            *       MICHIGAN BELL TELEPHONE COMPANY         *"
  203. MESSAGE "            *           A DIVISION OF AMERITECH             *"
  204. MESSAGE "            *                                               *"
  205. MESSAGE "            *                                               *"
  206. MESSAGE "            *************************************************"
  207. MESSAGE " "
  208. MESSAGE " "
  209. MESSAGE "          ....TO EXIT THIS PROGRAM AT ANY TIME, PRESS <ESC>...."
  210. PAUSE 3
  211. ALARM 1
  212.  
  213. ;VARIABLE DOCUMENTATION
  214. ;S0=CLLI A USER INPUT
  215. ;S1=CLLI B USER INPUT
  216. ;S2=CLLI LOCAL USER INPUT
  217. ;S3=YEAR 2 DIGIT USER INPUT
  218. ;S4=MONTH 2 DIGIT USER INPUT
  219. ;S5=DAY 2 DIGIT USER INPUT
  220. ;S6=HOUR 2 DIGIT USER INPUT
  221. ;S7=MINUTE 2 DIGIT USER INPUT
  222. ;S8=SYSTEM ID & USER RESPONSE USED TO CONTROL PROGRAM FLOW
  223. ;S9=SYSTEM NUMBER
  224.  
  225. LABEL1:
  226.  
  227. ; note the following statement was superseded in version 4.10 by VPRINT
  228. ;DOS "MODE LPT1:=COM2:" ; REQUIRED TO TURN PRINTER ERROR OFF
  229. ; following flushes the "RUB" buffer
  230. TRANSMIT "^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H"
  231. CLEAR
  232. LOCATE 10,2
  233. MESSAGE "Enter CLLI code for LOCATION A (C.O.) using full 8 or 11 characters:"
  234. LOCATE 12,2
  235. GET S0 11 ;CLLI A
  236. MESSAGE " "
  237. CLEAR
  238. LOCATE 10,2
  239. MESSAGE "Enter CLLI code for LOCATION B (REMOTE) using full 8 or 11 characters:"
  240. LOCATE 12,2
  241. GET S1 11 ;CLLI B
  242. MESSAGE " "
  243. CLEAR
  244. LOCATE 10,2
  245. MESSAGE "Enter CLLI code for YOUR location using full 8 or 11 characters:"
  246. LOCATE 12,2
  247. GET S2 11
  248.  
  249. CLEAR
  250. LOCATE 8,2
  251. MESSAGE "Enter system ID without 'MI', for example ALBNMN-JCSNMN."
  252. LOCATE 10,2
  253. GET S8 13
  254. LOCATE 13,2
  255. MESSAGE "Enter system number, for example 1201 / T3X."
  256. LOCATE 15,2
  257. GET S9 15
  258.  
  259. TRANSMIT "CGNS"
  260. TRANSMIT "`""
  261. TRANSMIT S8
  262. TRANSMIT "`""
  263. TRANSMIT "!"
  264.  
  265. CLEAR
  266. LOCATE 6,2
  267. MESSAGE "Enter today's date."
  268. LOCATE 8,2
  269. MESSAGE "Enter two digit year + <ENTER>"
  270. LOCATE 8,34
  271. GET S3 2 ; 2 DIGIT YEAR
  272. LOCATE 10,2
  273. MESSAGE "Enter two digit month + <ENTER>.  Use 0's if required."
  274. LOCATE 10,58
  275. GET S4 2 ; 2 DIGIT MONTH
  276. LOCATE 12,2
  277. MESSAGE "Enter two digit day + <ENTER>.  Use 0's if required."
  278. LOCATE 12,56
  279. GET S5 2 ; 2 DIGIT DAY
  280. CLEAR
  281. LOCATE 6,2
  282. MESSAGE "Enter time."
  283. LOCATE 8,2
  284. MESSAGE "Enter two digit hour + <ENTER>.  Use 0's if required."
  285. LOCATE 8,57
  286. GET S6 2 ; 2 DIGIT HOUR
  287. LOCATE 10,2
  288. MESSAGE "Enter two digit minute + <ENTER>.  Use 0's if required."
  289. LOCATE 10,59
  290. GET S7 2 ; 2 DIGIT MINUTE
  291. CLEAR
  292.  
  293. ;SET TIME DP3025
  294. TRANSMIT "CT"
  295. TRANSMIT S6
  296. TRANSMIT " "
  297. TRANSMIT S7
  298. TRANSMIT " !"
  299. PAUSE 1
  300. KFLUSH
  301. RFLUSH
  302. CLEAR
  303.  
  304. ;PROMPT THE USER TO CHECK INPUTS FOR LOCATIONS
  305. LOCATE 1,2
  306. MESSAGE "Please verify the following information."
  307. LOCATE 4,2
  308. MESSAGE "LOCATION A CLLI CODE = "
  309. LOCATE 4,26
  310. MESSAGE S0
  311. LOCATE 6,2
  312. MESSAGE "LOCATION B CLLI CODE = "
  313. LOCATE 6,26
  314. MESSAGE S1
  315. LOCATE 8,2
  316. MESSAGE "LOCAL LOCATION CLLI CODE ="
  317. LOCATE 8,29
  318. MESSAGE S2
  319. LOCATE 10,2
  320. MESSAGE "SYSTEM ID = "
  321. LOCATE 10,17
  322. MESSAGE S8
  323. LOCATE 12,2
  324. MESSAGE "SYSTEM NUMBER = "
  325. LOCATE 12,21
  326. MESSAGE S9
  327. LOCATE 17,2
  328. MESSAGE "IS INFORMATION CORRECT?  Y/N + <ENTER>"
  329. LOCATE 17,44
  330. GET S8 1
  331. SWITCH S8
  332.      CASE "Y"
  333.           ;DO NOTHING
  334.      ENDCASE
  335.      DEFAULT
  336.           GOTO LABEL1 ; JUMP TO TOP AND ENTER INFORMATION AGAIN
  337.      ENDCASE
  338. ENDSWITCH
  339. CLEAR
  340. LOCATE 8,15
  341. MESSAGE "DO NOT PRESS ANY KEYS UNTIL CONFIGURATION COMPLETE"
  342. LOCATE 10,15
  343. MESSAGE "OK...HERE WE GO..."
  344. ALARM 1
  345. PAUSE 2
  346.  
  347. ;SET DATE DP3024
  348. TRANSMIT "CD"
  349. TRANSMIT S3
  350. TRANSMIT " "
  351. TRANSMIT S4
  352. TRANSMIT " "
  353. TRANSMIT S5
  354. TRANSMIT " !"
  355. PAUSE 1
  356.  
  357. ;NAME NODE 1 USING CENTRAL OFFICE CLLI CODE
  358. TRANSMIT "CGNN1 "
  359. TRANSMIT "`""
  360. TRANSMIT S0
  361. TRANSMIT "`""
  362. TRANSMIT "!"
  363.  
  364. ;NAME NODE 2 USING REMOTE CLLI CODE
  365. TRANSMIT "CGNN2 "
  366. TRANSMIT "`""
  367. TRANSMIT S1
  368. TRANSMIT "`""
  369. TRANSMIT "!"
  370.  
  371. ;DEFINE SITE
  372. TRANSMIT "CGS1 1 2 !"
  373. ;TRANSMIT "`""
  374. ;TRANSMIT S0
  375. ;TRANSMIT "`""
  376. ;TRANSMIT S1
  377. ;TRANSMIT " "
  378. ;TRANSMIT "!"
  379.  
  380. ;CONFIGURE CUSTOMER OUTPUT POINTS DP3013
  381. TRANSMIT "CGNO1 "
  382. TRANSMIT "`"BAY MINOR`""
  383. TRANSMIT "!"
  384. TRANSMIT "CGNO2 "
  385. TRANSMIT "`"BAY MAJOR`""
  386. TRANSMIT "!"
  387. TRANSMIT "CGNO3 "
  388. TRANSMIT "`"OPT A FAIL`""
  389. TRANSMIT "!"
  390. TRANSMIT "CGNO4 "
  391. TRANSMIT "`"OPT B FAIL`""
  392. TRANSMIT "!"
  393. TRANSMIT "CGNO5 "
  394. TRANSMIT "`"STX TX`""
  395. TRANSMIT "!"
  396. TRANSMIT "CGNO6 "
  397. TRANSMIT "`"STX RX`""
  398. TRANSMIT "!"
  399. TRANSMIT "CGNO7 "
  400. TRANSMIT "`"M13 ALARM #1`""
  401. TRANSMIT "!"
  402. TRANSMIT "CGNO8 "
  403. TRANSMIT "`"M13 ALARM #2`""
  404. TRANSMIT "!"
  405. TRANSMIT "CGNO9 "
  406. TRANSMIT "`"M13 ALARM #3`""
  407. TRANSMIT "!"
  408. TRANSMIT "CGNO10 "
  409. TRANSMIT "`"HSA ALARM`""
  410. TRANSMIT "!"
  411. TRANSMIT "CGNO11 "
  412. TRANSMIT "`"HSB ALARM`""
  413. TRANSMIT "!"
  414. ;TRANSMIT "CGNO12 "
  415. ;TRANSMIT "`"DS1 GRP FAIL`""
  416. ;TRANSMIT "!"
  417. TRANSMIT "CGNO13 "
  418. TRANSMIT "`""
  419. TRANSMIT S9
  420. TRANSMIT "`""
  421. TRANSMIT "!"
  422. TRANSMIT "CGNO14 "
  423. TRANSMIT "`"COM EQUIP ALRM`""
  424. TRANSMIT "!"
  425. TRANSMIT "CGNO15 "
  426. TRANSMIT "`"NODE #1 CO`""
  427. TRANSMIT "!"
  428. TRANSMIT "CGNO16 "
  429. TRANSMIT "`"NODE #2 REMOTE`""
  430. TRANSMIT "!"
  431.  
  432. ;DELETE ALL EXISTING CUSTOMER OUTPUTS
  433. TRANSMIT "CGO1 D*!"
  434. TRANSMIT "CGO2 D*!"
  435. TRANSMIT "CGO3 D*!"
  436. TRANSMIT "CGO4 D*!"
  437. TRANSMIT "CGO5 D*!"
  438. TRANSMIT "CGO6 D*!"
  439. TRANSMIT "CGO7 D*!"
  440. TRANSMIT "CGO8 D*!"
  441. TRANSMIT "CGO9 D*!"
  442. TRANSMIT "CGO10 D*!"
  443. TRANSMIT "CGO11 D*!"
  444. TRANSMIT "CGO12 D*!"
  445. TRANSMIT "CGO13 D*!"
  446. TRANSMIT "CGO14 D*!"
  447. TRANSMIT "CGO15 D*!"
  448. TRANSMIT "CGO16 D*!"
  449.  
  450. ;CUSTOMER OUTPUTS 1-2
  451. TRANSMIT "CGO1 AS1 G100 !"
  452. TRANSMIT "CGO2 AS1 G120 !"
  453.  
  454. ;CUSTOMER OUTPUTS 3-9
  455. TRANSMIT "CGO3 AS1 G107 !"
  456. TRANSMIT "CGO4 AS1 G108 !"
  457. TRANSMIT "CGO5 AS1 G101 !"
  458. TRANSMIT "CGO5 AS1 G102 !"
  459. TRANSMIT "CGO5 AS1 G103 !"
  460. TRANSMIT "CGO6 AS1 G104 !"
  461. TRANSMIT "CGO6 AS1 G105 !"
  462. TRANSMIT "CGO6 AS1 G106 !"
  463. TRANSMIT "CGO7 AS1 G109 !"
  464. TRANSMIT "CGO8 AS1 G110 !"
  465. TRANSMIT "CGO9 AS1 G111 !"
  466.  
  467. ;CUSTOMER OUTPUTS 10-11
  468. TRANSMIT "CGO10 AS1 M1 MH18 !"
  469. TRANSMIT "CGO10 AS1 M2 MH18 !"
  470. TRANSMIT "CGO10 AS1 M3 MH18 !"
  471. TRANSMIT "CGO11 AS1 M1 MH19 !"
  472. TRANSMIT "CGO11 AS1 M2 MH19 !"
  473. TRANSMIT "CGO11 AS1 M3 MH19 !"
  474. ;TRANSMIT "CGO12 AS1 M1 1H2 !"
  475. ;TRANSMIT "CGO12 AS1 M2 1H2 !"
  476. ;TRANSMIT "CGO12 AS1 M3 1H2 !"
  477. ;TRANSMIT "CGO12 AS1 M1 1H3 !"
  478. ;TRANSMIT "CGO12 AS1 M2 1H3 !"
  479. ;TRANSMIT "CGO12 AS1 M3 1H3 !"
  480.  
  481. ;CUSTOMER OUTPUT 13, 14
  482. TRANSMIT "CGO13 AS1 G100 !"
  483. TRANSMIT "CGO13 AS1 G120 !"
  484. TRANSMIT "CGO14 AS1 G112 !"
  485.  
  486. ;CUSTOMER OUTPUTS 15, 16
  487. TRANSMIT "CGO15 AN1 G100 !"
  488. TRANSMIT "CGO15 AN1 G120 !"
  489. TRANSMIT "CGO16 AN2 G100 !"
  490. TRANSMIT "CGO16 AN2 G120 !"
  491.  
  492. ;SET TO AUTOMATIC CONTROL
  493. TRANSMIT "CGO1 CA!"
  494. TRANSMIT "CGO2 CA!"
  495. TRANSMIT "CGO3 CA!"
  496. TRANSMIT "CGO4 CA!"
  497. TRANSMIT "CGO5 CA!"
  498. TRANSMIT "CGO6 CA!"
  499. TRANSMIT "CGO7 CA!"
  500. TRANSMIT "CGO8 CA!"
  501. TRANSMIT "CGO9 CA!"
  502. TRANSMIT "CGO10 CA!"
  503. TRANSMIT "CGO11 CA!"
  504. TRANSMIT "CGO12 CA!"
  505. TRANSMIT "CGO13 CA!"
  506. TRANSMIT "CGO14 CA!"
  507. TRANSMIT "CGO15 CA!"
  508. TRANSMIT "CGO16 CA!"
  509. ;
  510. ;DEFINE CUSTOMER OUTPUT 12
  511. TRANSMIT "CGO12 D*!"
  512. TRANSMIT "CGNO12 "
  513. TRANSMIT "`"EXT ALM`""
  514. TRANSMIT "!"
  515. TRANSMIT "CGO12 AN2 G118 !"
  516. ;also attach to pt 13 for alarm center ID
  517. TRANSMIT "CGO13 AN2 G118 !"
  518. ;
  519. ;DEFINE CUSTOMER INPUTS
  520. TRANSMIT "CGNI1 "
  521. TRANSMIT "`"SMOKE DET.`""
  522. TRANSMIT "!"
  523. TRANSMIT "CGNI2 "
  524. TRANSMIT "`"SUMP PUMP`"" 
  525. TRANSMIT "!" 
  526. TRANSMIT "CGNI3 " 
  527. TRANSMIT "`"OPEN DOOR`""
  528. TRANSMIT "!"
  529. TRANSMIT "CGNI4 "
  530. TRANSMIT "`"AC PWR FAIL`""
  531. TRANSMIT "!"
  532. TRANSMIT "CGNI5 "
  533. TRANSMIT "`"HI-LO TEMP`""
  534. TRANSMIT "!"
  535. TRANSMIT "CGNI6 "
  536. TRANSMIT "`"RECT. FAIL`""
  537. TRANSMIT "!"
  538. TRANSMIT "CGNI7 "
  539. TRANSMIT "`"BATT FLOAT`""
  540. TRANSMIT "!"
  541. ;
  542. ;ADD CONDITIONS TO CUSTOMER OUTPUT 1
  543. TRANSMIT "CGO1 AN2 SS5 !"
  544. TRANSMIT "CGO1 AN2 SS6 !"
  545. TRANSMIT "CGO1 AN2 SS7 !"
  546. ;
  547. ;ADD CONDITIONS TO CUSTOMER OUTPUT 2
  548. TRANSMIT "CGO2 AN2 SS1 !"
  549. TRANSMIT "CGO2 AN2 SS2 !"
  550. TRANSMIT "CGO2 AN2 SS3 !"
  551. TRANSMIT "CGO2 AN2 SS4 !"
  552. ;
  553.      ;PER JOE OLSZTYN SWITCHING SYSTEMS STAFF
  554.      ;LEAVE PERFORMANCE MONITORING AT FACTORY DEFAULT
  555.      ;DISABLE BLUE INSERTION FOR POINT TO POINT SYSTEMS
  556.      ;IN A MULTIPOINT SYSTEM BLUE INSERTION SHOULD BE ENABLED.
  557.  
  558.      ;ENABLE ALARM LOGGER
  559.      TRANSMIT "CAD!"
  560.  
  561.      ;DISABLE BLUE INSERTION NODE 1 DP3019
  562.      TRANSMIT "CN1 T1 BE!"
  563.      TRANSMIT "CN1 T2 BE!"
  564.      TRANSMIT "CN1 T3 BE!"
  565.  
  566.      ;ENABLE PARITY CORRECTION NODE 1 DP3020
  567.      TRANSMIT "CN1 T1 PE!"
  568.      TRANSMIT "CN1 T2 PE!"
  569.      TRANSMIT "CN1 T3 PE!"
  570.  
  571.      ;ENABLE RX OVERHEAD NODE 1 DP3021
  572.      TRANSMIT "CN1 T1 RE!"
  573.      TRANSMIT "CN1 T2 RE!"
  574.      TRANSMIT "CN1 T3 RE!"
  575.  
  576.      ;ENABLE TX OVERHEAD NODE 1 DP3022
  577.      TRANSMIT "CN1 T1 TE!"
  578.      TRANSMIT "CN1 T2 TE!"
  579.      TRANSMIT "CN1 T3 TE!"
  580.  
  581.      ;SIGNAL DEGRADE 10E-8 NODE 1 DP3158
  582.      TRANSMIT "CN1 T1 S8!" 
  583.      TRANSMIT "CN1 T2 S8!"
  584.      TRANSMIT "CN1 T3 S8!"
  585.  
  586.      ;DISABLE BLUE INSERTION NODE 2 DP3019
  587.      TRANSMIT "CN2 T1 BE!"
  588.      TRANSMIT "CN2 T2 BE!"
  589.      TRANSMIT "CN2 T3 BE!"
  590.  
  591.      ;ENABLE PARITY CORRECTION NODE 2 DP3020
  592.      TRANSMIT "CN2 T1 PE!"
  593.      TRANSMIT "CN2 T2 PE!"
  594.      TRANSMIT "CN2 T3 PE!"
  595.  
  596.      ;ENABLE RX OVERHEAD NODE 2 DP3021
  597.      TRANSMIT "CN2 T1 RE!"
  598.      TRANSMIT "CN2 T2 RE!"
  599.      TRANSMIT "CN2 T3 RE!"
  600.  
  601.      ;ENABLE TX OVERHEAD NODE 2 DP3022
  602.      TRANSMIT "CN2 T1 TE!"
  603.      TRANSMIT "CN2 T2 TE!"
  604.      TRANSMIT "CN2 T3 TE!"
  605.  
  606.      ;SIGNAL DEGRADE 10E-8 NODE 2 DP3158
  607.      TRANSMIT "CN2 T1 S8!" 
  608.      TRANSMIT "CN2 T2 S8!"
  609.      TRANSMIT "CN2 T3 S8!"
  610.  
  611. ;LINE LEARN ALL MULTIPLEXERS BOTH NODES
  612. TRANSMIT "CN1 M1 L!"
  613. TRANSMIT "CN1 M2 L!"
  614. TRANSMIT "CN1 M3 L!"
  615. TRANSMIT "CN2 M1 L!"
  616. TRANSMIT "CN2 M2 L!"
  617. TRANSMIT "CN2 M3 L!"
  618.  
  619. ;CONFIGURATION IS COMPLETE EXIT THE PROGRAM
  620. CLEAR
  621. ALARM 1
  622. LOCATE 10,20
  623. MESSAGE "......CONFIGURATION COMPLETE......"
  624. LOCATE 14,17
  625. MESSAGE "CONTINUE WITH SECTION 5 OF CERTIFICATION"
  626. ALARM 2
  627. PAUSE 5
  628. EXIT
  629.  
  630.  
  631. ----------------------------------------------------------------------------
  632.             Glossary of Terms
  633.  
  634. 4W    Four Wire
  635. ACO    Alarm Cut-Off
  636. ACTV    Active (module -- carrying traffic)
  637. AGC     Automatic Gain Control
  638. AIS     Alarm Indication Signal -- indicates an alarm upstream
  639. AMI    Alternate Mark Inversion -- a technique by which the polarity of
  640.     alternate pulses is inverted
  641. APD    Avalanche Photo Diode -- used for detecting pulses of light
  642.     at the receive end of an optical fiber
  643. AUD    Audible alarm
  644. BDF    Battery Distribution Frame
  645. BER    Bit Error Rate
  646. BIP    Bit Interleave Parity
  647. BPV    Bipolar Violation -- signal is not alternating as expected
  648. CAMMS   Centralized Access Maintenance and Monitoring System --
  649.         a bay-mounted shelf with push buttons and an luminescent display,
  650.     which is used to control FMT-150 networks, as well as other 
  651.     Northern Telecom transmission equipment
  652. CDP    Centralized Display Panel
  653. CEV    Controlled Environment Vault
  654. CO    Central Office
  655. CPC    Common Product Code -- a Northern Telecom code used to identify
  656.     equipment
  657. DDD    Direct Distance Dialing
  658. DM-13   Digital Multiplexer which multiplexes between DS-1/1C/2 signals
  659.     and DS-3 signals
  660. DNA    Dynamic Network Architecture
  661. E2A    A serial interface for alarm polling of equipment
  662. FE    Frame Error
  663. FER    Frame Error Rate
  664. FL    Frame Loss
  665. FLC     Frame Loss Counter
  666. FLS    Frame Loss Seconds
  667. FPD    Future Product to be Developed
  668. Group    A multiplexed signal made up of four DS-1s, two DS-1Cs, or 
  669.     one Ds-2
  670. Hub    An FMT-150 site which branches one 150 Mb/s signal into two or
  671.     three signals, in different directions, without sacrificing 
  672.     OA & M continuity
  673. LBR    Loopback Request
  674. MCU    Maintenance Control Unit
  675. MM    Multimode Optical Fiber
  676. MSB    Most Significant Bit
  677. Muldem  Multiplexer/demultiplexer
  678. NRZ    Non-Return to Zero
  679. OTT    Optical Termination Tray
  680. PEC    Product Engineering Code -- a Norther Telecom code used to identify
  681.     equipment.  The preferred code to be used when ordering Northern
  682.     Telecom equipment.
  683. PER    Parity Error Rate
  684. PES    Parity Error Seconds
  685. RTO    Ready To Order
  686. SCU    Service Channel Unit
  687. SMB    Sub-Miniature BNC type connector
  688. SR    Stuff Request
  689. STX    (Pseudo) Synchronous Transport Signal: First Level at
  690.     49.92  Mb/s (Northern Telecom)
  691. TBOS    Telemetry Byte Oriented System
  692. VIS    Visual Alarm