home *** CD-ROM | disk | FTP | other *** search
-
-
-
-
-
-
- Network Working Group G. Malkin
- Request for Comments: 1783 Xylogics, Inc.
- Updates: 1350 A. Harkin
- Category: Standards Track Hewlett Packard Co.
- March 1995
-
-
- TFTP Blocksize Option
-
- Status of this Memo
-
- This document specifies an Internet standards track protocol for the
- Internet community, and requests discussion and suggestions for
- improvements. Please refer to the current edition of the "Internet
- Official Protocol Standards" (STD 1) for the standardization state
- and status of this protocol. Distribution of this memo is unlimited.
-
- Abstract
-
- The Trivial File Transfer Protocol [1] is a simple, lock-step, file
- transfer protocol which allows a client to get or put a file onto a
- remote host. One of its primary uses is the booting of diskless
- nodes on a Local Area Network. TFTP is used because it is very
- simple to implement in a small node's limited ROM space. However,
- the choice of a 512-byte blocksize is not the most efficient for use
- on a LAN whose MTU may 1500 bytes or greater.
-
- This document describes a TFTP option which allows the client and
- server to negotiate a blocksize more applicable to the network
- medium. The TFTP Option Extension mechanism is described in [2].
-
- Blocksize Option Specification
-
- The TFTP Read Request or Write Request packet is modified to include
- the blocksize option as follows:
-
- +-------+---~~---+---+---~~---+---+---~~---+---+---~~---+---+
- | opc |filename| 0 | mode | 0 | blksize| 0 | #octets| 0 |
- +-------+---~~---+---+---~~---+---+---~~---+---+---~~---+---+
-
- opc
- The opcode field contains either a 1, for Read Requests, or 2,
- for Write Requests, as defined in [1].
-
- filename
- The name of the file to be read or written, as defined in [1].
- This is a NULL-terminated field.
-
-
-
-
- Malkin & Harkin [Page 1]
-
- RFC 1783 TFTP Blocksize Option March 1995
-
-
- mode
- The mode of the file transfer: "netascii", "octet", or "mail",
- as defined in [1]. This is a NULL-terminated field.
-
- blksize
- The Blocksize option, "blksize" (case insensitive). This is a
- NULL-terminated field.
-
- #octets
- The number of octets in a block, specified in ASCII. Valid
- values range between "8" and "65464" octets, inclusive. This
- is a NULL-terminated field.
-
- For example:
-
- +-------+--------+---+--------+---+--------+---+--------+---+
- | 1 | foobar | 0 | binary | 0 | blksize| 0 | 1432 | 0 |
- +-------+--------+---+--------+---+--------+---+--------+---+
-
- is a Read Request, for the file named "foobar", in binary transfer
- mode, with a block size of 1432 bytes (Ethernet MTU, less the UDP and
- IP header lengths).
-
- If the server is willing to accept the blocksize option, it sends an
- Option Acknowledgment (OACK) to the client. The specified value must
- be less than or equal to the value specified by the client. The
- client must then either use the size specified in the OACK, or send
- an ERROR packet, with error code 8, to terminate the transfer.
-
- The rules for determining the final packet are unchanged from [1].
- The reception of a data packet with a data length less than the
- negotiated blocksize is the final packet. If the blocksize is
- greater than the size of the packet, the first packet is the final
- packet. If amount of data to be transfered is an integral multiple
- of the blocksize, an extra data packet containing no data is sent to
- end the transfer.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Malkin & Harkin [Page 2]
-
- RFC 1783 TFTP Blocksize Option March 1995
-
-
- Proof of Concept
-
- Performance tests were run on the prototype implementation using a
- variety of block sizes. The tests were run on a lightly loaded
- Ethernet, between two HP-UX 9000, in "octet" mode, on 2.25MB files.
- The average (5x) transfer times for paths with (g-time) and without
- (n-time) a intermediate gateway are graphed as follows:
-
- |
- 37 + g
- |
- 35 +
- |
- 33 +
- |
- 31 +
- |
- 29 +
- |
- 27 +
- | g blocksize n-time g-time
- 25 + --------- ------ ------
- s | n 512 23.85 37.05
- e 23 + g 1024 16.15 25.65
- c | 1432 13.70 23.10
- o 21 + 2048 10.90 16.90
- n | 4096 6.85 9.65
- d 19 + 8192 4.90 6.15
- s |
- 17 + g
- | n
- 15 +
- | n
- 13 +
- |
- 11 + n
- | g
- 9 +
- |
- 7 + n
- | g
- 5 + n
- "
- 0 +------+------+--+---+------+------+---
- 512 1K | 2K 4K 8K
- 1432
- blocksize (bytes)
-
-
-
-
- Malkin & Harkin [Page 3]
-
- RFC 1783 TFTP Blocksize Option March 1995
-
-
- The comparisons between transfer times (without a gateway) between
- the standard 512-byte blocksize and the negotiated blocksizes are:
-
- 1024 2x -32%
- 1432 2.8x -42%
- 2048 4x -54%
- 4096 8x -71%
- 8192 16x -80%
-
- As was anticipated, the transfer time decreases with an increase in
- blocksize. The reason for the reduction in time is the reduction in
- the number of packets sent. For example, by increasing the blocksize
- from 512 bytes to 1024 bytes, not only are the number of data packets
- halved, but the number of acknowledgement packets is also halved
- (along with the number of times the data transmitter must wait for an
- ACK). A secondary effect is the efficiency gained by reducing the
- per-packet framing and processing overhead.
-
- Of course, if the blocksize exceeds the path MTU, IP fragmentation
- and reassembly will begin to add more overhead. This will be more
- noticable the greater the number of gateways in the path.
-
- Security Considerations
-
- Security issues are not discussed in this memo.
-
- References
-
- [1] Sollins, K., "The TFTP Protocol (Revision 2)", STD 33, RFC 1350,
- MIT, July 1992.
-
- [2] Malkin, G., and A. Harkin, "TFTP Option Extension", RFC 1782,
- Xylogics, Inc., Hewlett Packard Co., March 1995.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Malkin & Harkin [Page 4]
-
- RFC 1783 TFTP Blocksize Option March 1995
-
-
- Authors' Addresses
-
- Gary Scott Malkin
- Xylogics, Inc.
- 53 Third Avenue
- Burlington, MA 01803
-
- Phone: (617) 272-8140
- EMail: gmalkin@xylogics.com
-
-
- Art Harkin
- Internet Services Project
- Information Networks Division
- 19420 Homestead Road MS 43LN
- Cupertino, CA 95014
-
- Phone: (408) 447-3755
- EMail: ash@cup.hp.com
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-