- Network Working Group J. Hilgeman, Chair
- Request for Comments: 1747 Apertus Technologies, Inc.
- Category: Standards Track S. Nix
- Metaplex, Inc.
- A. Bartky
- Sync Research, Inc.
- W. Clark, Editor
- cisco Systems, Inc.
- January 1995
-
-
- Definitions of Managed Objects for SNA Data Link Control (SDLC)
- using SMIv2
-
- Status of this Memo
-
- This document specifies an Internet standards track protocol for the
- Internet community, and requests discussion and suggestions for
- improvements. Please refer to the current edition of the "Internet
- Official Protocol Standards" (STD 1) for the standardization state
- and status of this protocol. Distribution of this memo is unlimited.
-
- Abstract
-
- This specification defines an extension to the Management Information
- Base (MIB) for use with SNMP-based network management. In
- particular, it defines objects for managing the configuration,
- monitoring and control of data link controls in an SNA environment.
- This draft identifies managed objects for SNA Synchronous Data Link
- Control (SDLC) links only.
-
- Table of Contents
-
- 1. The SNMPv2 Network Management Framework ................. 2
- 1.1 Object Definitions .................................... 2
- 2. Overview ................................................ 2
- 2.1 Tables Defined in the SNADLC SDLC MIB ................. 3
- 2.2 Row Creation Mechanism ................................ 3
- 2.3 Relationship to the Interfaces Group .................. 4
- 3. Definitions ............................................. 7
- 3.1 Port Administrative Table ............................. 9
- 3.2 Port Operational Table ............................... 14
- 3.3 Port Statistics Table ................................ 20
- 3.4 Link Station Administrative Table .................... 26
- 3.5 Link Station Operational Table ....................... 35
- 3.6 Link Station Statistics Table ........................ 44
- 3.7 Trap Definitions ..................................... 56
- 3.8 Compliance Statements ................................ 57
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 1]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- 4. Acknowledgments ........................................ 65
- 5. References ............................................. 65
- 6. Glossary ............................................... 66
- 7. Security Considerations ................................ 67
- 8. Authors' Addresses ..................................... 67
-
- 1. The SNMPv2 Network Management Framework
-
- The SNMPv2 Network Management Framework consists of four major
- components. They are:
-
- o RFC 1441 which defines the SMI, the mechanisms used for
- describing and naming objects for the purpose of management.
-
- o STD 17, RFC 1213 defines MIB-II, the core set of managed
- objects for the Internet suite of protocols.
-
- o RFC 1445 which defines the administrative and other
- architectural aspects of the framework.
-
- o RFC 1448 which defines the protocol used for network access
- to managed objects.
-
- The Framework permits new objects to be defined for the purpose of
- experimentation and evaluation.
-
- 1.1. Object Definitions
-
- Managed objects are accessed via a virtual information store, termed
- the Management Information Base or MIB. Objects in the MIB are
- defined using the subset of Abstract Syntax Notation One (ASN.1)
- defined in the SMI. In particular, each object object type is named
- by an OBJECT IDENTIFIER, an administratively assigned name. The
- object type together with an object instance serves to uniquely
- identify a specific instantiation of the object. For human
- convenience, we often use a textual string, termed the descriptor, to
- refer to the object type.
-
- 2. Overview
-
- This memo identifies the proposed set of objects for configuring,
- monitoring, and controlling SDLC ports and link stations.
-
-
-
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 2]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- 2.1. Tables Defined in the SNADLC SDLC MIB
-
- The SNADLC MIB is composed of two managed entities with three tables
- each. The two managed entities for SDLC are:
-
- o Ports: the physical connection, and
-
- o Link Stations: the logical connections on the Port.
-
- The three management tables are:
-
- o Adminstration: objects used for configuring and controlling
- the operation of a Port or Link Station,
-
- o Operational: objects that reflect the run-time state of the
- Port or Link Station, and
-
- o Statistics: objects that reflect the operating metrics of the
- Port or Link Station.
-
- Considering the above combinations, the following are the actual
- tables found in this MIB:
-
- 1) Port Administration Table,
-
- 2) Port Operation Table,
-
- 3) Port Statistics Table,
-
- 4) Link Station Administration Table,
-
- 5) Link Station Operation Table,
-
- 6) Link Station Statistics Table.
-
- All variables in this MIB relate to SDLC ports and link stations
- only. Any variable relating to higher-layer entities in SNA such as
- Physical Units (PU) and Logical Units (LU) are found in the SNA NAU
- MIB [4].
-
- 2.2. Row Creation Mechanism
-
- Row creation mechanism for the sdlcLSAdminTable is based on the use
- of the RowStatus object. It follows the rules for the use in SNMPv1
- context proposed in the memo "Row creation with SNMPv1" [5]. Before
- accepting the destroy value for an entry, an agent has to verify the
- operational state of the corresponding entry in the sdlcLSOperTable
- entry.
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 3]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- 2.3. Relationship to the Interfaces Group
-
- This memo shall conform to the recommendations of [6].
-
- The SDLC layer of each SDLC Port shall be modeled by a row in the
- ifTable with an ifType using the IANA assigned number for SDLC (17).
- Each SDLC port interface must comply with the following conformance
- groups in [6]:
-
- - ifGeneralGroup
- - ifStackGroup
- - ifPacketGroup
-
- An implementation may optionally comply with the ifTestGroup defined
- in that memo to execute vendor specific tests. An example of this
- would be to perform LPDA test functions.
-
- The SDLC port's relation with its physical, or lower-layer interface
- (i.e., RS-232, V.35, etc.) shall be modeled by a row in the
- ifStackTable with the ifStackHigherLayer pointing to the SDLC port
- ifTable instance and the ifStackLowerLayer pointing to the physical
- media-specific ifTable instance. The media-specific objects of these
- lower-layer interfaces will, of course, be described in their
- respective MIBs (i.e., [1]).
-
- The following table provides specific implementation guidelines for
- all the interface group objects listed in the conformance tables
- above.
-
- Object Use for an SDLC Port
-
- ifIndex Each SDLC port is represented by an ifEntry. All
- SDLC port tables shall be indexed by ifIndex.
-
- ifDescr Description of the SDLC port.
-
- ifType The IANA value reserved for SDLC - 17.
-
- ifMtu Refer to [6].
-
- ifSpeed This object shall reflect the value of the
- corresponding object in the ifEntry of the
- associated lower-layer interface.
-
- ifPhysAddress A string denoting the physical location of the SDLC
- port within its node. This shall have unique
- significance within each implementing node.
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 4]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- ifAdminStatus This object shall reflect the value of the
- corresponding object in the ifEntry of the
- associated lower-layer interface.
-
- ifOperStatus This object shall reflect the value of the
- corresponding object in the ifEntry of the
- associated lower-layer interface.
-
- ifLastChange Refer to [6].
-
- ifInOctets Refer to [6].
-
- ifInUcastPkts This object shall count packets received from a
- specific SDLC poll address. Packets for the SDLC
- broadcast address of x'FF' are not counted.
-
- ifInDiscards Refer to [6].
-
- ifInErrors Refer to [6]. Specific counters for these errors
- are kept in the sdlcPortStatsTable.
-
- ifInUnknownProtos This counter shall return zero for SDLC ports.
-
- ifOutOctets Refer to [6].
-
- ifOutUcastPkts This object shall count packets transmitted to a
- specific SDLC poll address (not x'FF').
-
- ifOutDiscards Refer to [6].
-
- ifOutErrors Refer to [6]. Specific counters for these errors
- are kept in the sdlcPortStatsTable.
-
- ifName The textual name of the SDLC port or an octet string
- of zero length.
-
- ifInMulticastPkts The value is 0 (not applicable to the SDLC layer).
-
- ifInBroadcastPkts This object shall count packets received on this
- interface addressed to the SDLC broadcast address
- (x'FF'). Only point-to-point ports supporting a
- secondary switched station should return non-zero
- values.
-
- ifOutMulticastPkts The value is 0 (not applicable to the SDLC layer).
-
- ifOutBroadcastPkts This object shall count packets transmitted on this
- interface which were addressed to the SDLC broadcast
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 5]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- address (x'FF'). Only point-to-point ports
- supporting a primary switched station should
- return non-zero values.
-
- ifHC* Not part of the conformance group.
-
- ifLinkUpDownTrapEnable
- Refer to [6]. Default is disabled (2).
-
- ifHighSpeed Refer to [6].
-
- ifPromiscuousMode Should return false if this interface receives only
- packets addressed to its SDLC poll address(es).
- However, in certain implementations, the lower-layer
- interface shall present all frames to the SDLC port
- regardless of the poll address. Such frames may be
- the result of a misconfigured peer or the secondary
- end of a multipoint connection. Such
- implementations should return true for this
- object.
-
- ifConnectorPresent Set to 'false'.
-
- ifStackHigherLayer For each SDLC port there will be an ifStackEntry
- with this object's value referring to the ifIndex of
- the SDLC port's ifEntry for the SDLC layer.
-
- ifStackLowerLayer For each SDLC port there will be an ifStackEntry
- with this object's value referring to the ifIndex of
- the physical layer interface's ifEntry for that SDLC
- port.
-
- ifStackStatus Refer to [6].
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 6]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- 3. Definitions
-
- SNA-SDLC-MIB DEFINITIONS ::= BEGIN
-
- IMPORTS
- MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
- Counter32, Integer32, TimeTicks
- FROM SNMPv2-SMI
- DisplayString, RowStatus, TimeInterval
- FROM SNMPv2-TC
- MODULE-COMPLIANCE, OBJECT-GROUP
- FROM SNMPv2-CONF
- mib-2, ifIndex, ifAdminStatus, ifOperStatus
- FROM RFC1213-MIB;
-
-
- snaDLC MODULE-IDENTITY
- LAST-UPDATED "9411150000Z"
- ORGANIZATION "IETF SNA DLC MIB Working Group"
- CONTACT-INFO
- " Wayne Clark
-
- Postal: cisco Systems, Inc.
- 3100 Smoketree Ct.
- Suite 1000
- Raleigh, NC 27604
- US
-
- Tel: +1 919 878 6958
-
- E-Mail: wclark@cisco.com"
-
- DESCRIPTION
- "This is the MIB module for objects used to
- manage SDLC devices."
-
- ::= { mib-2 41 }
-
- --
- -- The following data link controls are modelled in this MIB module:
- --
- -- 1. SDLC
- --
-
- sdlc OBJECT IDENTIFIER ::= { snaDLC 1 }
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 7]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- --
- -- THE SDLC GROUP
- -- ==============
- --
- -- The following resources are modelled in the SDLC group of this
- -- MIB module:
- --
- -- 1. PORTS
- -- 2. LINK STATIONS
-
- sdlcPortGroup OBJECT IDENTIFIER ::= { sdlc 1 } -- Physical Ports
- sdlcLSGroup OBJECT IDENTIFIER ::= { sdlc 2 } -- Logical Link Stations
-
- --
- -- THE SDLC PORT GROUP
- -- ===================
- --
- -- The following classes of information is modelled for each SDLC port:
- --
- -- 1. ADMINISTRATIVE ( read/write)
- -- 2. OPERATIONAL ( read-only)
- -- 3. STATISTICS ( read-only)
-
- -- Information not found in this group is found in tables described in
- -- the following RFCs:
- --
- -- 1. RFC1213 - MIB-II
- --
- -- TABLE INDEX
- -- ==================== ====================
- -- a. ifTable ifIndex
- --
- -- 2. RFC1659 - The RS232-like MIB
- --
- -- TABLE INDEX
- -- ==================== ====================
- -- a. rs232PortTable rs232PortIndex
- -- b. rs232SyncPortTable rs232SyncPortIndex
- -- c. rs232InSigTable rs232InSigPortIndex,
- -- rs232InSigName
- -- d. rs232OutSigTable rs232OutSigPortIndex,
- -- rs232OutSigName
- -- ** e. rs232AsyncPortTable rs232AsyncPortIndex
- --
- -- ** rs232AsyncPortTable for ISO 3309.3 ( Start-Stop SDLC).
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 8]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- -- *************************************************************
- -- * *
- -- * THE SDLC PORT ADMINISTRATIVE TABLE *
- -- * *
- -- *************************************************************
-
- sdlcPortAdminTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SdlcPortAdminEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "This table contains objects that can be
- changed to manage an SDLC port. Changing one
- of these parameters may take effect in the
- operating port immediately or may wait until
- the interface is restarted depending on the
- details of the implementation.
-
- Most of the objects in this read-write table
- have corresponding read-only objects in the
- sdlcPortOperTable that return the current
- operating value.
-
- The operating values may be different from
- these configured values if a configured
- parameter was changed after the interface was
- started."
- ::= { sdlcPortGroup 1 }
-
- sdlcPortAdminEntry OBJECT-TYPE
- SYNTAX SdlcPortAdminEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "A list of configured values for an SDLC port."
- INDEX { ifIndex }
- ::= { sdlcPortAdminTable 1 }
-
- SdlcPortAdminEntry ::= SEQUENCE
- {
- sdlcPortAdminName DisplayString,
- sdlcPortAdminRole INTEGER,
- sdlcPortAdminType INTEGER,
- sdlcPortAdminTopology INTEGER,
- sdlcPortAdminISTATUS INTEGER,
- sdlcPortAdminACTIVTO TimeInterval,
- sdlcPortAdminPAUSE TimeInterval,
- sdlcPortAdminSERVLIM Integer32,
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 9]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcPortAdminSlowPollTimer TimeInterval
- }
-
- sdlcPortAdminName OBJECT-TYPE
- SYNTAX DisplayString (SIZE (1..10))
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "An octet string that defines the physical port
- to which this interface is assigned. It has
- implementation-specific significance. Its value
- shall be unique within the administered
- system. It must contain only ASCII printable
- characters. Should an implementation choose to
- accept a write operation for this object, it
- causes the logical port definition associated
- with the table instance to be moved to a
- different physical port. A write operation
- shall not take effect until the port is cycled
- inactive."
- ::= { sdlcPortAdminEntry 1 }
-
- sdlcPortAdminRole OBJECT-TYPE
- SYNTAX INTEGER
- {
- primary(1),
- secondary(2),
- negotiable(3)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This object describes the role that the link
- station shall assume the next time a connection
- is established.
-
- Even though this is defined as a port object,
- it is a link station attribute in the sense
- that a role is per link station. However, it
- is not possible to vary link station roles on a
- particular port. For example, if an SDLC port
- is configured to primary, all link stations on
- that port must be primary."
- ::= { sdlcPortAdminEntry 2 }
-
- sdlcPortAdminType OBJECT-TYPE
- SYNTAX INTEGER
- {
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 10]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- leased(1),
- switched(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This parameter defines whether the SDLC port
- is to connect to a leased or switched line. A
- write operation to this administrative value
- shall not take effect until the SDLC port has
- been cycled inactive."
- DEFVAL { leased }
- ::= { sdlcPortAdminEntry 3 }
-
- sdlcPortAdminTopology OBJECT-TYPE
- SYNTAX INTEGER
- {
- pointToPoint(1),
- multipoint(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This parameter defines whether the SDLC port is
- capable of operating in either a point-to-point
- or multipoint topology.
-
- sdlcPortAdminTopology == multipoint implies the
- port can also operate in a point-to-point
- topology. sdlcPortAdminTopology ==
- pointToPoint does not imply the port can
- operate in a multipoint topology.
-
- A write operation to this administrative value
- shall not take effect until the SDLC port has
- been cycled inactive."
- DEFVAL { pointToPoint }
- ::= { sdlcPortAdminEntry 4 }
-
- sdlcPortAdminISTATUS OBJECT-TYPE
- SYNTAX INTEGER
- {
- inactive(1),
- active(2)
- }
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 11]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- "This parameter controls the initial value of
- the administrative status, ifAdminStatus, of
- this SDLC port at port start-up. Depending
- on the implementation, a write operation to
- this administrative object may not take effect
- until the SDLC port has been cycled inactive."
- DEFVAL { active }
- ::= { sdlcPortAdminEntry 5 }
-
- sdlcPortAdminACTIVTO OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This parameter defines the period of time (in
- 1/100ths of a second) that the port will allow a
- switched line to remain inactive before
- disconnecting. A switched line is considered
- to be inactive if there are no I-Frames being
- transferred. A value of zero indicates no
- timeout. Depending on the implementation, a
- write operation to this administered value may
- not take effect until the port is cycled
- inactive.
-
- This object only has meaning for SDLC ports
- where sdlcPortAdminType == switched
-
- The object descriptor contains the name of an
- NCP configuration parameter, ACTIVTO. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP ACTIVTO is
- represented in seconds."
- DEFVAL { 0 }
- ::= { sdlcPortAdminEntry 6 }
-
- sdlcPortAdminPAUSE OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This object defines the minimum elapsed time
- (in 1/100ths of a second) between any two
- traversals of the poll list for a primary SDLC
- port. Depending on the implementation, a write
- operation to this administered value may not
- take effect until the port is cycled inactive.
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 12]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- The object descriptor contains the name of an
- NCP configuration parameter, PAUSE. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP PAUSE is
- represented in 1/10ths of a second.
-
- This object only has meaning for SDLC ports
- where sdlcPortAdminRole == primary "
- DEFVAL { 200 }
- ::= { sdlcPortAdminEntry 7 }
-
- sdlcPortAdminSERVLIM OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This object defines the number of times the
- active poll list will be traversed before
- polling a station on the slow poll list for a
- primary, multipoint SDLC port. Depending on
- the implementation, a write operation to this
- administered value may not take effect until
- the port is cycled inactive.
-
- This object only has meaning for SDLC ports
- where
- sdlcPortAdminRole == primary
- and
- sdlcPortAdminTopology == multipoint "
- DEFVAL { 20 }
- ::= { sdlcPortAdminEntry 8 }
-
- sdlcPortAdminSlowPollTimer OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-write
- STATUS current
- DESCRIPTION
- "This object describes the elapsed time (in
- 1/100ths of a second) between polls for failed
- secondary link station addresses. Depending
- on the implementation, a write operation to
- this administered value may not take effect
- until the port is cycled inactive.
-
- This object only has meaning for SDLC ports
- where
- sdlcPortAdminRole == primary
- and
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 13]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcPortAdminTopology == multipoint "
- DEFVAL { 2000 }
- ::= { sdlcPortAdminEntry 9 }
-
- -- *************************************************************
- -- * *
- -- * THE SDLC PORT OPERATIONAL TABLE *
- -- * *
- -- *************************************************************
-
- sdlcPortOperTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SdlcPortOperEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "This table contains current SDLC port
- parameters. Many of these objects have
- corresponding objects inthe sdlcPortAdminTable."
- ::= { sdlcPortGroup 2 }
-
- sdlcPortOperEntry OBJECT-TYPE
- SYNTAX SdlcPortOperEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Currently set parameters for a specific SDLC
- port."
- INDEX { ifIndex }
- ::= { sdlcPortOperTable 1 }
-
- SdlcPortOperEntry ::= SEQUENCE
- {
- sdlcPortOperName DisplayString,
- sdlcPortOperRole INTEGER,
- sdlcPortOperType INTEGER,
- sdlcPortOperTopology INTEGER,
- sdlcPortOperISTATUS INTEGER,
- sdlcPortOperACTIVTO TimeInterval,
- sdlcPortOperPAUSE TimeInterval,
- sdlcPortOperSlowPollMethod INTEGER,
- sdlcPortOperSERVLIM Integer32,
- sdlcPortOperSlowPollTimer TimeInterval,
- sdlcPortOperLastModifyTime TimeTicks,
- sdlcPortOperLastFailTime TimeTicks,
- sdlcPortOperLastFailCause INTEGER
- }
-
- sdlcPortOperName OBJECT-TYPE
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 14]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- SYNTAX DisplayString (SIZE (1..8))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "An octet string that describes the physical
- port to which this interface is currently
- attached. It has implementation-specific
- significance."
- ::= { sdlcPortOperEntry 1 }
-
- sdlcPortOperRole OBJECT-TYPE
- SYNTAX INTEGER
- {
- primary(1),
- secondary(2),
- undefined(3)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the role that the link
- station has assumed on this connection.
-
- Even though this is defined as a port object,
- it is a link station attribute in the sense
- that a role is per link station. However, it
- is not possible to vary link station roles on a
- particular port. For example, if an SDLC port
- is configured to primary, all link stations on
- that port must be primary.
-
- The value of sdlcPortOperRole is undefined(3)
- whenever the link station role has not yet been
- established by the mode setting command."
- ::= { sdlcPortOperEntry 2 }
-
- sdlcPortOperType OBJECT-TYPE
- SYNTAX INTEGER
- {
- leased(1),
- switched(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This parameter defines whether the SDLC port
- is currently operating as though connected to a
- leased or switched line."
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 15]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- ::= { sdlcPortOperEntry 3 }
-
- sdlcPortOperTopology OBJECT-TYPE
- SYNTAX INTEGER
- {
- pointToPoint(1),
- multipoint(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This parameter defines whether the SDLC port is
- currently operating in a point-to-point or
- multipoint topology."
- ::= { sdlcPortOperEntry 4 }
-
- sdlcPortOperISTATUS OBJECT-TYPE
- SYNTAX INTEGER
- {
- inactive(1),
- active(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This parameter describes the initial value of
- the administrative status, ifAdminStatus, of
- this SDLC port at last port start-up."
- ::= { sdlcPortOperEntry 5 }
-
-
- sdlcPortOperACTIVTO OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This parameter defines the period of time (in
- 100ths of a second) that the port will allow a
- switched line to remain inactive before
- disconnecting. A switched line is considered
- to be inactive if there are no I-Frames being
- transferred.
-
- The object descriptor contains the name of an
- NCP configuration parameter, ACTIVTO. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP ACTIVTO is
- represented in seconds.
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 16]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- A value of zero indicates no timeout."
- ::= { sdlcPortOperEntry 6 }
-
- sdlcPortOperPAUSE OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the current minimum
- elapsed time (in 1/100ths of a second) between
- any two traversals of the poll list for a
- primary SDLC port.
-
- The object descriptor contains the name of an
- NCP configuration parameter, PAUSE. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP PAUSE is
- represented in 1/10ths of a second.
-
- This object only has meaning for SDLC ports
- where
- sdlcPortAdminRole == primary "
- ::= { sdlcPortOperEntry 7 }
-
- sdlcPortOperSlowPollMethod OBJECT-TYPE
- SYNTAX INTEGER
- {
- servlim(1),
- pollpause(2),
- other(3)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object defines the exact method that is in
- effect for periodically polling failed secondary
- link station addresses.
-
- If sdlcPortOperSlowPollMethod == servlim, then
- sdlcPortOperSERVLIM defines the actual polling
- characteristics.
-
- If sdlcPortOperSlowPollMethod == pollpause,
- then sdlcPortOperSlowPollTimer defines the
- actual polling characteristics.
-
- If sdlcPortOperSlowPollMethod == other, then
- the polling characteristics are modeled in
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 17]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- vendor-specific objects.
-
- This object only has meaning for SDLC ports
- where
- sdlcPortOperRole == primary
- and
- sdlcPortOperTopology == multipoint "
- ::= { sdlcPortOperEntry 8 }
-
- sdlcPortOperSERVLIM OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the number of times the
- active poll list is currently being traversed
- before polling a station on the slow poll list
- for a primary, multipoint SDLC port.
-
- This object only has meaning for SDLC ports
- where
- sdlcPortOperRole == primary
- and
- sdlcPortOperTopology == multipoint "
- ::= { sdlcPortOperEntry 9 }
-
- sdlcPortOperSlowPollTimer OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the elapsed time (in
- 1/100ths of a second) between polls for failed
- secondary link station addresses.
-
- This object only has meaning for SDLC ports
- where
- sdlcPortOperRole == primary
- and
- sdlcPortOperTopology == multipoint "
- ::= { sdlcPortOperEntry 10 }
-
- sdlcPortOperLastModifyTime OBJECT-TYPE
- SYNTAX TimeTicks
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the value of sysUpTime
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 18]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- when this port definition was last modified.
- If the port has not been modified, then this
- value shall be zero."
- ::= { sdlcPortOperEntry 11 }
-
- sdlcPortOperLastFailTime OBJECT-TYPE
- SYNTAX TimeTicks
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the value of sysUpTime
- when this SDLC port last failed. If the port
- has not failed, then this value shall be zero."
- ::= { sdlcPortOperEntry 12 }
-
- sdlcPortOperLastFailCause OBJECT-TYPE
- SYNTAX INTEGER
- {
- undefined(1),
- physical(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This enumerated object describes the cause of
- the last failure of this SDLC port. If the
- port has not failed, then this object has a
- value of undefined(1)."
- DEFVAL { undefined }
- ::= { sdlcPortOperEntry 13 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 19]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- -- *************************************************************
- -- * *
- -- * THE SDLC PORT STATISTICS TABLE *
- -- * *
- -- *************************************************************
-
- sdlcPortStatsTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SdlcPortStatsEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Each entry in this table contains statistics
- for a specific SDLC port."
- ::= { sdlcPortGroup 3 }
-
- sdlcPortStatsEntry OBJECT-TYPE
- SYNTAX SdlcPortStatsEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "A list of statistics for an SDLC port."
- INDEX { ifIndex }
- ::= { sdlcPortStatsTable 1 }
-
- SdlcPortStatsEntry ::= SEQUENCE
- {
- sdlcPortStatsPhysicalFailures Counter32,
- sdlcPortStatsInvalidAddresses Counter32,
- sdlcPortStatsDwarfFrames Counter32,
- sdlcPortStatsPollsIn Counter32,
- sdlcPortStatsPollsOut Counter32,
- sdlcPortStatsPollRspsIn Counter32,
- sdlcPortStatsPollRspsOut Counter32,
- sdlcPortStatsLocalBusies Counter32,
- sdlcPortStatsRemoteBusies Counter32,
- sdlcPortStatsIFramesIn Counter32,
- sdlcPortStatsIFramesOut Counter32,
- sdlcPortStatsOctetsIn Counter32,
- sdlcPortStatsOctetsOut Counter32,
- sdlcPortStatsProtocolErrs Counter32,
- sdlcPortStatsActivityTOs Counter32,
- sdlcPortStatsRNRLIMITs Counter32,
- sdlcPortStatsRetriesExps Counter32,
- sdlcPortStatsRetransmitsIn Counter32,
- sdlcPortStatsRetransmitsOut Counter32
- }
-
- sdlcPortStatsPhysicalFailures OBJECT-TYPE
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 20]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of times
- this port has failed due to its physical media
- since port startup. At port startup time,
- this object must be initialized to zero."
- ::= { sdlcPortStatsEntry 1 }
-
- sdlcPortStatsInvalidAddresses OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- frames received by this port with invalid link
- station addresses."
- ::= { sdlcPortStatsEntry 2 }
-
- sdlcPortStatsDwarfFrames OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- frames received by this port which were
- delivered intact by the physical layer but were
- too short to be legal.
-
- Ignoring the frame check sequence (FCS), a
- frame is considered to be too short if it
- is less than 2 bytes for sdlcLSOperMODULO of
- eight, or if it is less than 3 bytes for
- sdlcLSOperMODULO of onetwentyeight."
-
- ::= { sdlcPortStatsEntry 3 }
-
- sdlcPortStatsPollsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of polls
- received by this port since the port was
- created."
-
- ::= { sdlcPortStatsEntry 4 }
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 21]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcPortStatsPollsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of polls
- sent by this port since the port was created."
-
- ::= { sdlcPortStatsEntry 5 }
-
- sdlcPortStatsPollRspsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of poll
- responses received by this port since the port
- was created."
-
- ::= { sdlcPortStatsEntry 6 }
-
- sdlcPortStatsPollRspsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of poll
- responses sent by this port since the port was
- created."
-
- ::= { sdlcPortStatsEntry 7 }
-
- sdlcPortStatsLocalBusies OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- times that the local SDLC link stations on
- this port have entered a busy state (RNR).
- This object is initialized to zero when the
- port is created."
- ::= { sdlcPortStatsEntry 8 }
-
- sdlcPortStatsRemoteBusies OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 22]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- DESCRIPTION
- "This object reflects the total number of
- times that the adjacent (i.e., remote) SDLC
- link stations on this port have entered a busy
- state (RNR). This object is initialized to
- zero when the port is created."
- ::= { sdlcPortStatsEntry 9 }
-
- sdlcPortStatsIFramesIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- I-Frames that have been received by SDLC link
- stations on this port. This object is
- initialized to zero when the port is created."
- ::= { sdlcPortStatsEntry 10 }
-
- sdlcPortStatsIFramesOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- I-Frames that have been transmitted by SDLC
- link stations on this port. This object is
- initialized to zero when the port is created."
- ::= { sdlcPortStatsEntry 11 }
-
- sdlcPortStatsOctetsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total octets
- received from adjacent SDLC link stations on
- this port. This object covers the address,
- control, and information field of I-Frames
- only. This object is initialized to zero when
- the port is created."
- ::= { sdlcPortStatsEntry 12 }
-
- sdlcPortStatsOctetsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 23]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- "This object reflects the total octets
- transmitted to adjacent SDLC link stations on
- this port. This object covers the address,
- control, and information field of I-Frames
- only. This object is initialized to zero when
- the port is created."
- ::= { sdlcPortStatsEntry 13 }
-
- sdlcPortStatsProtocolErrs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- times that the SDLC link stations on this port
- have deactivated the link as a result of
- having received a protocol violation from the
- adjacent link station. This object is
- initialized to zero when the port is created."
- ::= { sdlcPortStatsEntry 14 }
-
- sdlcPortStatsActivityTOs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- times that the SDLC link stations on this port
- have deactivated the link as a result of no
- activity on the link. This object is
- initialized to zero when the port is created."
- ::= { sdlcPortStatsEntry 15 }
-
- sdlcPortStatsRNRLIMITs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- times that the SDLC link stations on this port
- have deactivated the link as a result of its
- RNRLIMIT timer expiring. This object is
- initialized to zero when the port is created."
- ::= { sdlcPortStatsEntry 16 }
-
- sdlcPortStatsRetriesExps OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 24]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- times that the SDLC link stations on this port
- have deactivated the link as a result of a
- retry sequence being exhausted. This object
- is initialized to zero when the port is
- created."
- ::= { sdlcPortStatsEntry 17 }
-
- sdlcPortStatsRetransmitsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- I-Frames retransmitted by remote link stations
- for all SDLC link stations on this port. This
- object is initialized to zero when the port is
- created."
- ::= { sdlcPortStatsEntry 18 }
-
- sdlcPortStatsRetransmitsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- I-Frames retransmitted by all local SDLC link
- stations on this port. This object is
- initialized to zero when the port is created."
- ::= { sdlcPortStatsEntry 19 }
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 25]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- --
- -- THE SDLC LINK STATION GROUP
- -- ===========================
- --
-
- -- The following classes of information is modelled for each SDLC link
- -- station:
- --
- -- 1. ADMINISTRATIVE ( read-write)
- -- 2. OPERATIONAL ( read-only)
- -- 3. STATISTICS ( read-only)
-
- -- *************************************************************
- -- * *
- -- * THE SDLC LINK STATION ADMINISTRATIVE TABLE *
- -- * *
- -- *************************************************************
-
- sdlcLSAdminTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SdlcLSAdminEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "This table contains objects that can be
- changed to manage an SDLC link station.
- Changing one of these parameters may take
- effect in the operating link immediately or may
- wait until the link is restarted depending on
- the details of the implementation.
-
- The entries in sdlcLSAdminTable can be created
- either by an agent or a management station. The
- management station can create an entry in
- sdlcLSAdminTable by setting the appropriate
- value in sdlcLSAdminRowStatus.
-
- Most of the objects in this read-create table
- have corresponding read-only objects in the
- sdlcLSOperTable that reflect the current
- operating value.
-
- The operating values may be different from
- these configured values if changed by XID
- negotiation or if a configured parameter was
- changed after the link was started."
- ::= { sdlcLSGroup 1 }
-
- sdlcLSAdminEntry OBJECT-TYPE
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 26]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- SYNTAX SdlcLSAdminEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "A list of configured values for an SDLC link
- station."
- INDEX { ifIndex, sdlcLSAddress }
- ::= { sdlcLSAdminTable 1 }
-
- SdlcLSAdminEntry ::= SEQUENCE
- {
- sdlcLSAddress INTEGER,
- sdlcLSAdminName DisplayString,
- sdlcLSAdminState INTEGER,
- sdlcLSAdminISTATUS INTEGER,
- sdlcLSAdminMAXDATASend Integer32,
- sdlcLSAdminMAXDATARcv Integer32,
- sdlcLSAdminREPLYTO TimeInterval,
- sdlcLSAdminMAXIN INTEGER,
- sdlcLSAdminMAXOUT INTEGER,
- sdlcLSAdminMODULO INTEGER,
- sdlcLSAdminRETRIESm INTEGER,
- sdlcLSAdminRETRIESt TimeInterval,
- sdlcLSAdminRETRIESn Integer32,
- sdlcLSAdminRNRLIMIT TimeInterval,
- sdlcLSAdminDATMODE INTEGER,
- sdlcLSAdminGPoll INTEGER,
- sdlcLSAdminSimRim INTEGER,
- sdlcLSAdminXmitRcvCap INTEGER,
- sdlcLSAdminRowStatus RowStatus
- }
-
- sdlcLSAddress OBJECT-TYPE
- SYNTAX INTEGER (1..255)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This value is the poll address of the
- secondary link station for this SDLC link. It
- uniquely identifies the SDLC link station
- within a single SDLC port."
- ::= { sdlcLSAdminEntry 1 }
-
- sdlcLSAdminName OBJECT-TYPE
- SYNTAX DisplayString (SIZE (1..10))
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 27]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- "An octet string that defines the local name of
- the SDLC link station. This field may be sent
- in the XID3 control vector 0x0E, type 0xF7."
- ::= { sdlcLSAdminEntry 2 }
-
- sdlcLSAdminState OBJECT-TYPE
- SYNTAX INTEGER
- {
- inactive(1),
- active(2)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the desired state of the
- SDLC station. The managed system shall attempt
- to keep the operational state, sdlcLSOperState,
- consistent with this value."
- DEFVAL { active }
- ::= { sdlcLSAdminEntry 3 }
-
- sdlcLSAdminISTATUS OBJECT-TYPE
- SYNTAX INTEGER
- {
- inactive(1),
- active(2)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This parameter controls the desired state,
- sdlcLSAdminState, of the SDLC link station at
- link station start-up."
- DEFVAL { active }
- ::= { sdlcLSAdminEntry 4 }
-
- sdlcLSAdminMAXDATASend OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object contains the maximum PDU size that
- the local link station thinks it can send to
- the adjacent link station before having
- received any XID from the ALS. After the
- maximum PDU size that the ALS can receive is
- known (via XID exchange) that value is
- reflected in sdlcLSOperMAXDATASend and takes
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 28]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- precedence over this object.
-
- This value includes the Transmission Header
- (TH) and the Request Header (RH)."
- ::= { sdlcLSAdminEntry 5 }
-
- sdlcLSAdminMAXDATARcv OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object contains the maximum PDU size that
- the local link station can receive from the
- adjacent link station. This value is sent in
- the XID to the ALS.
-
- This value includes the Transmission Header
- (TH) and the Request Header (RH)."
- ::= { sdlcLSAdminEntry 6 }
-
- sdlcLSAdminREPLYTO OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the reply timeout (in
- 1/100ths of a second) for an SDLC link
- station. If the link station does not receive
- a response to a poll or message before the
- specified time expires then the appropriate
- error recovery shall be initiated.
-
- The object descriptor contains the name of an
- NCP configuration parameter, REPLYTO. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP REPLYTO is
- represented in 1/10ths of a second.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value, sdlcLSOperREPLYTO,
- until the link station is cycled inactive.
-
- This object only has meaning for SDLC ports
- where sdlcPortAdminRole == primary "
- DEFVAL { 100 }
- ::= { sdlcLSAdminEntry 7 }
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 29]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSAdminMAXIN OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the maximum number of
- unacknowledged I-frames which an SDLC link
- station may receive. This should range from 1
- to (sdlcLSAdminMODULO - 1). This value is sent
- in the XID to the ALS.
-
- A write operation to this administered value
- will not change the operational value,
- sdlcLSOperMAXIN, until the link station is
- cycled inactive."
- DEFVAL { 7 }
- ::= { sdlcLSAdminEntry 8 }
-
- sdlcLSAdminMAXOUT OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the maximum number of
- consecutive unacknowledged I-frames which an
- SDLC link station shall send without an
- acknowledgement. This shall range from 1 to
- (sdlcLSAdminMODULO - 1).
-
- For link stations on switched SDLC lines,
- certain implementions may choose to override
- this administered value with the value
- received in the XID exchange.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value,
- sdlcLSOperMAXOUT, until the link station is
- cycled inactive.
-
- An implementation can support only modulo 8,
- only modulo 128, or both."
- DEFVAL { 1 }
- ::= { sdlcLSAdminEntry 9 }
-
- sdlcLSAdminMODULO OBJECT-TYPE
- SYNTAX INTEGER
- {
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 30]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- eight(8),
- onetwentyeight(128)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the modulus for an SDLC
- link station. This modulus determines the size
- of the rotating acknowledgement window used the
- SDLC link station pair.
-
- A write operation to this administered value
- will not change the operational value,
- sdlcLSOperMODULO, until the link station is
- cycled inactive.
-
- An implementation can support only modulo 8,
- only modulo 128, or both."
- DEFVAL { eight }
- ::= { sdlcLSAdminEntry 10 }
-
- sdlcLSAdminRETRIESm OBJECT-TYPE
- SYNTAX INTEGER (0..128)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls number of retries in a
- retry sequence for the local SDLC link
- station. A retry sequence is a series of
- retransmitted frames ( data or control) for
- which no positive acknowledgement is received.
-
- The number of times that the retry sequence is
- to be repeated is controlled by the object:
- sdlcLSAdminRETRIESn. The interval between retry
- sequences is controlled by the object:
- sdlcLSAdminRETRIESt.
-
- A value of zero indicates no retries. If the
- value of sdlcLSAdminRETRIESm is zero, then the
- values of sdlcLSAdminRETRIESt and
- sdlcLSAdminRETRIESn should also be zero.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value,
- sdlcLSOperRETRIESm, until the link station is
- cycled inactive."
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 31]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- DEFVAL { 15 }
- ::= { sdlcLSAdminEntry 11 }
-
- sdlcLSAdminRETRIESt OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the interval (in 1/100ths
- of a second) between retry sequences for the
- local SDLC link station if multiple retry
- sequences are specified . A retry sequence is
- a series of retransmitted frames ( data or
- control) for which no positive acknowledgement
- is received.
-
- The number of repeated retries sequences is
- controlled by the object: sdlcLSAdminRETRIESn.
- The retries per sequence is controlled by the
- object: sdlcLSAdminRETRIESm.
-
- The object descriptor contains the name of an
- NCP configuration parameter, RETRIESt. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP RETRIESt is
- represented in seconds.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value,
- sdlcLSOperRETRIESt, until the link station is
- cycled inactive."
- DEFVAL { 0 }
- ::= { sdlcLSAdminEntry 12 }
-
- sdlcLSAdminRETRIESn OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the number of times that
- a retry sequence is repeated for the local SDLC
- link station. A retry sequence is a series of
- retransmitted frames ( data or control) for
- which no positive acknowledgement is received.
-
- The interval between retry sequences is
- controlled by the object: sdlcLSAdminRETRIESn.
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 32]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- The retries per sequence is controlled by the
- object: sdlcLSAdminRETRIESm.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value,
- sdlcLSOperRETRIESn, until the link station is
- cycled inactive."
- DEFVAL { 0 }
- ::= { sdlcLSAdminEntry 13 }
-
- sdlcLSAdminRNRLIMIT OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the length of time (in
- 1/100ths of a second) that an SDLC link station
- will allow its adjacent link station to remain
- in a busy (RNR) state before declaring it
- inoperative.
-
- A value of sdlcLSAdminRNRLIMIT == 0 means there
- is no limit.
-
- The object descriptor contains the name of an
- NCP configuration parameter, RNRLIMIT. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP RNRLIMIT is
- represented in minutes.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value,
- sdlcLSOperRNRLIMIT, until the link station is
- cycled inactive."
- DEFVAL { 18000 }
- ::= { sdlcLSAdminEntry 14 }
-
- sdlcLSAdminDATMODE OBJECT-TYPE
- SYNTAX INTEGER
- {
- half(1),
- full(2)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 33]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- "This object controls whether communications
- mode with the adjacent link station is
- two-way-alternate (half) or two-way-simultaneous
- (full).
-
- A write operation to this administered value
- will not change the operational value,
- sdlcLSOperDATMODE, until the link station is
- cycled inactive."
- DEFVAL { half }
- ::= { sdlcLSAdminEntry 15 }
-
- sdlcLSAdminGPoll OBJECT-TYPE
- SYNTAX INTEGER (0..254)
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object describes the group poll address
- for this link station instance. If group poll
- is not in effect for this link station
- instance, the value for sdlcLSAdminGPoll should
- be zero.
-
- Depending on the implementation, a write
- operation to this administered value may not
- change the operational value, sdlcLSOperGPoll,
- until the link station is cycled inactive."
- ::= { sdlcLSAdminEntry 16 }
-
- sdlcLSAdminSimRim OBJECT-TYPE
- SYNTAX INTEGER
- {
- no(1),
- yes(2)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the support for
- transmission and receipt of SIM and RIM control
- frames for this link station. The value of
- this object controls the setting of the
- transmit-receive capability sent in the XID
- field."
- DEFVAL { no }
- ::= { sdlcLSAdminEntry 17 }
-
- sdlcLSAdminXmitRcvCap OBJECT-TYPE
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 34]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- SYNTAX INTEGER
- {
- twa(1),
- tws(2)
- }
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object controls the transmit-receive
- capabilities for this SDLC link station. The
- value of this object establishes the value of
- the transmit-receive capability indicator sent
- in the XID image to the adjacent link station."
- DEFVAL { twa }
- ::= { sdlcLSAdminEntry 18 }
-
- sdlcLSAdminRowStatus OBJECT-TYPE
- SYNTAX RowStatus
- MAX-ACCESS read-create
- STATUS current
- DESCRIPTION
- "This object is used by a management station to
- create or delete the row entry in
- sdlcLSAdminTable following the RowStatus
- textual convention.
-
- Upon successful creation of the row, an agent
- automatically creates a corresponding entry in
- the sdlcLSOperTable with sdlcLSOperState equal
- to 'discontacted (1)'."
- ::= { sdlcLSAdminEntry 19 }
-
- -- *************************************************************
- -- * *
- -- * THE SDLC LINK STATION OPERATIONAL TABLE *
- -- * *
- -- *************************************************************
-
- sdlcLSOperTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SdlcLSOperEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "This table contains current SDLC link
- parameters. Many of these objects have
- corresponding objects in the
- sdlcLSAdminTable."
- ::= { sdlcLSGroup 2 }
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 35]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSOperEntry OBJECT-TYPE
- SYNTAX SdlcLSOperEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "A list of status and control values for an
- SDLC link station."
- INDEX { ifIndex, sdlcLSAddress }
- ::= { sdlcLSOperTable 1 }
-
- SdlcLSOperEntry ::= SEQUENCE
- {
- sdlcLSOperName DisplayString,
- sdlcLSOperRole INTEGER,
- sdlcLSOperState INTEGER,
- sdlcLSOperMAXDATASend Integer32,
- sdlcLSOperREPLYTO TimeInterval,
- sdlcLSOperMAXIN INTEGER,
- sdlcLSOperMAXOUT INTEGER,
- sdlcLSOperMODULO INTEGER,
- sdlcLSOperRETRIESm INTEGER,
- sdlcLSOperRETRIESt TimeInterval,
- sdlcLSOperRETRIESn INTEGER,
- sdlcLSOperRNRLIMIT TimeInterval,
- sdlcLSOperDATMODE INTEGER,
- sdlcLSOperLastModifyTime TimeTicks,
- sdlcLSOperLastFailTime TimeTicks,
- sdlcLSOperLastFailCause INTEGER,
- sdlcLSOperLastFailCtrlIn OCTET STRING,
- sdlcLSOperLastFailCtrlOut OCTET STRING,
- sdlcLSOperLastFailFRMRInfo OCTET STRING,
- sdlcLSOperLastFailREPLYTOs Counter32,
- sdlcLSOperEcho INTEGER,
- sdlcLSOperGPoll INTEGER,
- sdlcLSOperSimRim INTEGER,
- sdlcLSOperXmitRcvCap INTEGER
- }
-
- sdlcLSOperName OBJECT-TYPE
- SYNTAX DisplayString (SIZE (1..10))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "An octet string that defines the name of the
- remote SDLC link station. This field is
- received in the XID3 control vector 0x0E, type
- 0xF7."
- ::= { sdlcLSOperEntry 1 }
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 36]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSOperRole OBJECT-TYPE
- SYNTAX INTEGER
- {
- primary(1),
- secondary(2),
- undefined(3)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current role that the
- link station is assuming.
-
- The value of sdlcLSOperRole is undefined(3)
- whenever the link station role has not yet been
- established by the mode setting command."
- ::= { sdlcLSOperEntry 2 }
-
- sdlcLSOperState OBJECT-TYPE
- SYNTAX INTEGER
- {
- discontacted(1),
- contactPending(2),
- contacted(3),
- discontactPending(4)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the operational state of
- the SDLC link station. The managed system
- shall attempt to keep this value consistent
- with the administered state, sdlcLSAdminState"
- ::= { sdlcLSOperEntry 3 }
-
- sdlcLSOperMAXDATASend OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object contains the actual maximum PDU
- size that the local link station can send to
- the adjacent link station. This object is
- established from the value received in the XID
- from the adjacent link station. If no XID
- is received, then this value is implementation
- dependent (for instance, it could be the value
- of sdlcLSAdminMAXDATASend).
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 37]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- This value includes the Transmission Header
- (TH) and the Request Header (RH)."
- ::= { sdlcLSOperEntry 4 }
-
- sdlcLSOperREPLYTO OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current reply timeout
- (in 1/100ths of a second) for an SDLC link
- station. If the link station does not receive
- a response to a poll or message before the
- specified time expires then the appropriate
- error recovery shall be initiated.
-
- The object descriptor contains the name of an
- NCP configuration parameter, REPLYTO. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP REPLYTO is
- represented in 1/10ths of a second.
-
- This object only has meaning for SDLC ports
- where sdlcPortOperRole == primary "
- ::= { sdlcLSOperEntry 5 }
-
- sdlcLSOperMAXIN OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current maximum
- number of unacknowledged I-frames which an SDLC
- link station may receive. This shall range
- from 1 to (sdlcLSOperMODULO - 1)."
- ::= { sdlcLSOperEntry 6 }
-
- sdlcLSOperMAXOUT OBJECT-TYPE
- SYNTAX INTEGER (1..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object controls the maximum number of
- consecutive unacknowledged I-frames which an
- SDLC link station shall send without an
- acknowledgement. This shall range from 1 to
- (sdlcLSAdminMODULO - 1).
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 38]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- This value may controlled by the administered
- MAXOUT, sdlcLSAdminMAXOUT, or by the MAXIN value
- received during the XID exchange."
- ::= { sdlcLSOperEntry 7 }
-
- sdlcLSOperMODULO OBJECT-TYPE
- SYNTAX INTEGER
- {
- eight(8),
- onetwentyeight(128)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current modulus for
- an SDLC link station. This modulus determines
- the size of rotating acknowledgement window
- used by the SDLC link station pair."
- DEFVAL { eight }
- ::= { sdlcLSOperEntry 8 }
-
- sdlcLSOperRETRIESm OBJECT-TYPE
- SYNTAX INTEGER (0..128)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object controls number of retries in a
- retry sequence for an SDLC link station. A
- retry sequence is a series of retransmitted
- frames ( data or control) for which no positive
- acknowledgement is received.
-
- The current number of times that the retry
- sequence is to be repeated is reflected by the
- object: sdlcLSOperRETRIESn. The current
- interval between retry sequences is reflected
- by the object: sdlcLSOperRETRIESt."
- ::= { sdlcLSOperEntry 9 }
-
- sdlcLSOperRETRIESt OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current interval (in
- 1/100ths of a second) between retry sequences
- for an SDLC link station if multiple retry
- sequences are specified. A retry sequence is a
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 39]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- series of retransmitted frames ( data or
- control) for which no positive acknowledgement
- is received.
-
- The object descriptor contains the name of an
- NCP configuration parameter, RETRIESt. Please
- note that the value of this object represents
- 1/100ths of a second while the NCP RETRIESt is
- represented in seconds.
-
- The current number of repeated retries
- sequences is reflected by the object:
- sdlcLSOperRETRIESn. The current retries per
- sequence is reflected by the object:
- sdlcLSOperRETRIESm."
- ::= { sdlcLSOperEntry 10 }
-
- sdlcLSOperRETRIESn OBJECT-TYPE
- SYNTAX INTEGER (0..127)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current number of
- times that a retry sequence is repeated for an
- SDLC link station. A retry sequence is a
- series of retransmitted frames ( data or
- control) for which no positive acknowledgement
- is received.
-
- The current interval between retry sequences is
- reflected by the object: sdlcLSOperRETRIESn.
- The current retries per sequence is reflected
- by the object: sdlcLSOperRETRIESm."
- ::= { sdlcLSOperEntry 11 }
-
- sdlcLSOperRNRLIMIT OBJECT-TYPE
- SYNTAX TimeInterval
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the current length of
- time (in 1/100ths of a second) that an SDLC
- link station will allow its adjacent link
- station to remain in a busy (RNR) state before
- declaring it inoperative.
-
- The object descriptor contains the name of an
- NCP configuration parameter, RNRLIMIT. Please
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 40]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- note that the value of this object represents
- 1/100ths of a second while the NCP RNRLIMIT is
- represented in minutes.
-
- A value of sdlcLSOperRNRLIMIT == 0 means there
- is no limit."
- ::= { sdlcLSOperEntry 12 }
-
- sdlcLSOperDATMODE OBJECT-TYPE
- SYNTAX INTEGER
- {
- half(1),
- full(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects whether the current
- communications mode with the adjacent link
- station is two-way-alternate (half) or
- two-way-simultaneous (full)."
- ::= { sdlcLSOperEntry 13 }
-
- sdlcLSOperLastModifyTime OBJECT-TYPE
- SYNTAX TimeTicks
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the value of sysUpTime
- when this link station definition was last
- modified. If the link station has not been
- modified, then this value shall be zero."
- ::= { sdlcLSOperEntry 14 }
-
- sdlcLSOperLastFailTime OBJECT-TYPE
- SYNTAX TimeTicks
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the value of sysUpTime
- when this SDLC link station last failed. If
- the link station has not failed, then this
- value shall be zero."
- ::= { sdlcLSOperEntry 15 }
-
- sdlcLSOperLastFailCause OBJECT-TYPE
- SYNTAX INTEGER
- {
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 41]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- undefined(1),
- rxFRMR(2),
- txFRMR(3),
- noResponse(4),
- protocolErr(5),
- noActivity(6),
- rnrLimit(7),
- retriesExpired(8)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This enumerated object reflects the cause of
- the last failure of this SDLC link station. If
- the link station has not failed, then this
- object will have a value of undefined(1)."
- DEFVAL { undefined }
- ::= { sdlcLSOperEntry 16 }
-
- sdlcLSOperLastFailCtrlIn OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(1..2))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the last control octet or
- octets (depending on modulus) received by this
- SDLC link station at the time of the last
- failure. If the link station has not failed,
- then this value has no meaning."
- ::= { sdlcLSOperEntry 17 }
-
- sdlcLSOperLastFailCtrlOut OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(1..2))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the last control octet or
- octets (depending on modulus) sent by this SDLC
- link station at the time of the last failure.
- If the link station has not failed, then this
- value has no meaning."
- ::= { sdlcLSOperEntry 18 }
-
- sdlcLSOperLastFailFRMRInfo OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(3))
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 42]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- "This object reflects the information field of
- the FRMR frame if the last failure for this
- SDLC link station was as a result of an invalid
- frame. Otherwise, this field has no meaning."
- ::= { sdlcLSOperEntry 19 }
-
- sdlcLSOperLastFailREPLYTOs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the number of times that
- the REPLYTO timer had expired for an SDLC link
- station at the time of the last failure. If the
- link station has not failed, then this value
- has no meaning."
- ::= { sdlcLSOperEntry 20 }
-
- sdlcLSOperEcho OBJECT-TYPE
- SYNTAX INTEGER
- {
- no(1),
- yes(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object identifies whether the echo bit is
- in effect for this particular link station."
- DEFVAL { no }
- ::= { sdlcLSOperEntry 21 }
-
- sdlcLSOperGPoll OBJECT-TYPE
- SYNTAX INTEGER (0..254)
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object describes the group poll address
- in effect for this link station instance."
- DEFVAL { 0 }
- ::= { sdlcLSOperEntry 22 }
-
- sdlcLSOperSimRim OBJECT-TYPE
- SYNTAX INTEGER
- {
- no(1),
- yes(2)
- }
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 43]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the support for
- transmission and receipt of SIM and RIM control
- frames for the adjacent link station. The
- value of this object is set from the XID field
- received from the adjacent link station."
- DEFVAL { no }
- ::= { sdlcLSOperEntry 23 }
-
- sdlcLSOperXmitRcvCap OBJECT-TYPE
- SYNTAX INTEGER
- {
- twa(1),
- tws(2)
- }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the transmit-receive
- capabilities for the adjacent SDLC link
- station. The value of this object is the value
- of the transmit-receive capability indicator
- received in the XID image from the adjacent
- link station."
- DEFVAL { twa }
- ::= { sdlcLSOperEntry 24 }
-
-
- -- *************************************************************
- -- * *
- -- * THE SDLC LINK STATION STATISTICS TABLE *
- -- * *
- -- *************************************************************
-
- sdlcLSStatsTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SdlcLSStatsEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION
- "Each entry in this table contains statistics
- for a specific SDLC link station."
- ::= { sdlcLSGroup 3 }
-
- sdlcLSStatsEntry OBJECT-TYPE
- SYNTAX SdlcLSStatsEntry
- MAX-ACCESS not-accessible
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 44]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- STATUS current
- DESCRIPTION
- "A list of statistics for an SDLC link station."
- INDEX { ifIndex, sdlcLSAddress }
- ::= { sdlcLSStatsTable 1 }
-
- SdlcLSStatsEntry ::= SEQUENCE
- {
- sdlcLSStatsBLUsIn Counter32,
- sdlcLSStatsBLUsOut Counter32,
- sdlcLSStatsOctetsIn Counter32,
- sdlcLSStatsOctetsOut Counter32,
- sdlcLSStatsPollsIn Counter32,
- sdlcLSStatsPollsOut Counter32,
- sdlcLSStatsPollRspsIn Counter32,
- sdlcLSStatsPollRspsOut Counter32,
- sdlcLSStatsLocalBusies Counter32,
- sdlcLSStatsRemoteBusies Counter32,
- sdlcLSStatsIFramesIn Counter32,
- sdlcLSStatsIFramesOut Counter32,
- sdlcLSStatsUIFramesIn Counter32,
- sdlcLSStatsUIFramesOut Counter32,
- sdlcLSStatsXIDsIn Counter32,
- sdlcLSStatsXIDsOut Counter32,
- sdlcLSStatsTESTsIn Counter32,
- sdlcLSStatsTESTsOut Counter32,
- sdlcLSStatsREJsIn Counter32,
- sdlcLSStatsREJsOut Counter32,
- sdlcLSStatsFRMRsIn Counter32,
- sdlcLSStatsFRMRsOut Counter32,
- sdlcLSStatsSIMsIn Counter32,
- sdlcLSStatsSIMsOut Counter32,
- sdlcLSStatsRIMsIn Counter32,
- sdlcLSStatsRIMsOut Counter32,
- sdlcLSStatsDISCIn Counter32,
- sdlcLSStatsDISCOut Counter32,
- sdlcLSStatsUAIn Counter32,
- sdlcLSStatsUAOut Counter32,
- sdlcLSStatsDMIn Counter32,
- sdlcLSStatsDMOut Counter32,
- sdlcLSStatsSNRMIn Counter32,
- sdlcLSStatsSNRMOut Counter32,
- sdlcLSStatsProtocolErrs Counter32,
- sdlcLSStatsActivityTOs Counter32,
- sdlcLSStatsRNRLIMITs Counter32,
- sdlcLSStatsRetriesExps Counter32,
- sdlcLSStatsRetransmitsIn Counter32,
- sdlcLSStatsRetransmitsOut Counter32
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 45]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- }
-
- sdlcLSStatsBLUsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total basic link
- units (BLUs; frames) received from an adjacent
- SDLC link station since link station startup.
- At link station startup time, this object must
- be initialized to zero."
- ::= { sdlcLSStatsEntry 1 }
-
- sdlcLSStatsBLUsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total basic link
- units (BLUs; frames), transmitted to an
- adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 2 }
-
- sdlcLSStatsOctetsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total octets received
- from an adjacent SDLC link station since link
- station startup. This object covers the
- address, control, and information field of
- I-Frames only. At link station startup time,
- this object must be initialized to zero."
- ::= { sdlcLSStatsEntry 3 }
-
- sdlcLSStatsOctetsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total octets
- transmitted to an adjacent SDLC link station
- since link station startup. This object covers
- the address, control, and information field of
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 46]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- I-Frames only. At link station startup time,
- this object must be initialized to zero."
- ::= { sdlcLSStatsEntry 4 }
-
- sdlcLSStatsPollsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total polls received
- from an adjacent SDLC link station since link
- station startup. At link station startup time,
- this object must be initialized to zero."
- ::= { sdlcLSStatsEntry 5 }
-
- sdlcLSStatsPollsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total polls sent to
- an adjacent SDLC link station since link
- station startup. At link station startup time,
- this object must be initialized to zero."
- ::= { sdlcLSStatsEntry 6 }
-
- sdlcLSStatsPollRspsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of poll
- responses sent to the adjacent SDLC link
- station since link station startup. This value
- includes I-frames that are sent in response to
- a poll.
-
- At link station startup time, this object must
- be initialized to zero."
- ::= { sdlcLSStatsEntry 7 }
-
- sdlcLSStatsPollRspsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of poll
- responses received from the adjacent SDLC link
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 47]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- station since station startup. This value
- includes I-frames that are received in response
- to a poll.
-
- At link station startup time, this object must
- be initialized to zero."
- ::= { sdlcLSStatsEntry 8 }
-
- sdlcLSStatsLocalBusies OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of times
- that the local SDLC link station has entered a
- busy state (RNR) since link station startup.
- At link station startup time, this object must
- be initialized to zero."
- ::= { sdlcLSStatsEntry 9 }
-
- sdlcLSStatsRemoteBusies OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of times
- that an adjacent ( remote) SDLC link station
- has entered a busy state (RNR) since link
- station startup. At link station startup time,
- this object must be initialized to zero."
- ::= { sdlcLSStatsEntry 10 }
-
- sdlcLSStatsIFramesIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total I-frames
- received from an adjacent SDLC link station
- since link station startup. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 11 }
-
- sdlcLSStatsIFramesOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 48]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- DESCRIPTION
- "This object reflects the total I-frames
- transmitted to an adjacent SDLC link station
- since link station startup. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 12 }
-
- sdlcLSStatsUIFramesIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total UI-frames
- received from an adjacent SDLC link station
- since link station startup."
- ::= { sdlcLSStatsEntry 13 }
-
- sdlcLSStatsUIFramesOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total UI-frames
- transmitted to an adjacent SDLC link station
- since link station startup."
- ::= { sdlcLSStatsEntry 14 }
-
- sdlcLSStatsXIDsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total XID frames
- received from an adjacent SDLC link station
- since link station startup."
- ::= { sdlcLSStatsEntry 15 }
-
- sdlcLSStatsXIDsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total XID frames
- transmitted to an adjacent SDLC link station
- since link station startup."
- ::= { sdlcLSStatsEntry 16 }
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 49]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSStatsTESTsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total TEST frames,
- commands or responses, received from an
- adjacent SDLC link station since link station
- startup."
- ::= { sdlcLSStatsEntry 17 }
-
- sdlcLSStatsTESTsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total TEST frames,
- commands or responses, transmitted to an
- adjacent SDLC link station since link station
- startup."
- ::= { sdlcLSStatsEntry 18 }
-
- sdlcLSStatsREJsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total REJ frames
- received from an adjacent SDLC link station
- since link station startup."
- ::= { sdlcLSStatsEntry 19 }
-
- sdlcLSStatsREJsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total REJ frames
- transmitted to an adjacent SDLC link station
- since link station startup."
- ::= { sdlcLSStatsEntry 20 }
-
- sdlcLSStatsFRMRsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total frame reject
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 50]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- (FRMR) frames received from an adjacent SDLC
- link station since link station startup."
- ::= { sdlcLSStatsEntry 21 }
-
- sdlcLSStatsFRMRsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total frame reject
- (FRMR) frames transmitted to an adjacent SDLC
- link station since link station startup."
- ::= { sdlcLSStatsEntry 22 }
-
- sdlcLSStatsSIMsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total set
- initialization mode (SIM) frames received from
- an adjacent SDLC link station since link station
- startup."
- ::= { sdlcLSStatsEntry 23 }
-
- sdlcLSStatsSIMsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total set
- initialization mode (SIM) frames transmitted to
- an adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 24 }
-
- sdlcLSStatsRIMsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total request
- initialization mode (RIM) frames received from
- an adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 25 }
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 51]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSStatsRIMsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total request
- initialization mode (RIM) frames transmitted to
- an adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 26 }
-
- sdlcLSStatsDISCIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- disconnect (DISC) requests received from an
- adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 27 }
-
- sdlcLSStatsDISCOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- disconnect (DISC) requests transmited to an
- adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 28 }
-
- sdlcLSStatsUAIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- unnumbered acknowledgements (UA) requests
- received from an adjacent SDLC link station
- since link station startup. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 29 }
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 52]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSStatsUAOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- unnumbered acknowledgements (UA) requests
- transmited to an adjacent SDLC link station
- since link station startup. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 30 }
-
- sdlcLSStatsDMIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- disconnect mode (DM) requests received from an
- adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 31 }
-
- sdlcLSStatsDMOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- disconnect mode (DM) requests transmited to an
- adjacent SDLC link station since link station
- startup. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 32 }
-
- sdlcLSStatsSNRMIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- set normal response mode (SNRM/SNRME) requests
- received from an adjacent SDLC link station
- since link station startup. At link station
- startup time, this object must be initialized
- to zero."
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 53]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- ::= { sdlcLSStatsEntry 33 }
-
- sdlcLSStatsSNRMOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- set normal response mode (SNRM/SNRME) requests
- transmited to an adjacent SDLC link station
- since link station startup. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 34 }
-
- sdlcLSStatsProtocolErrs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total occurrences,
- since link station startup, where this SDLC
- link station has inactivated the link as a
- result of receiving a frame from its adjacent
- link station which was in violation of the
- protocol. At link station startup time, this
- object must be initialized to zero."
- ::= { sdlcLSStatsEntry 35 }
-
- sdlcLSStatsActivityTOs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total occurrences,
- since startup, where this SDLC link station has
- inactivated the link as a result of no activity
- on the link. At link station startup time,
- this object must be initialized to zero."
- ::= { sdlcLSStatsEntry 36 }
-
- sdlcLSStatsRNRLIMITs OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total occurrences,
- since startup, where this SDLC link station has
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 54]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- inactivated the link as a result of its
- RNRLIMIT timer expiring. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 37 }
-
- sdlcLSStatsRetriesExps OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total occurrences,
- since startup, where this SDLC link station has
- inactivated the link as a result of a retry
- sequence being exhausted. At link station
- startup time, this object must be initialized
- to zero."
- ::= { sdlcLSStatsEntry 38 }
-
- sdlcLSStatsRetransmitsIn OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION
- "This object reflects the total number of
- information frames retransmitted by the remote
- link station because the N(s) received from
- that link station indicated that one or more
- information frames sent by that station were
- lost. This event causes the first missing
- information frame of a window and all
- subsequent information frames to be
- retransmitted. At link station startup time,
- this object must be initialized to zero.
-
- Management: If the value of
- sdlcLSStatsRetransmitsIn grows over time, then
- the quality of the serial line is in
- question. You might want to look at
- decreasing the value for
- sdlcLSAdminMAXDATASend to compensate for the
- lower quality line."
- ::= { sdlcLSStatsEntry 39 }
-
- sdlcLSStatsRetransmitsOut OBJECT-TYPE
- SYNTAX Counter32
- MAX-ACCESS read-only
- STATUS current
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 55]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- DESCRIPTION
- "This object reflects the total number of
- information frames retransmitted to a remote
- link station because the N(r) received from
- that link station indicated that one or more
- information frames sent to that station were
- lost. This event causes the first missing
- information frame of a window and all
- subsequent information frames to be
- retransmitted. At link station startup time,
- this object must be initialized to zero.
-
- Management: If the value of
- sdlcLSStatsRetransmitsOut grows over time,
- then the quality of the serial line is in
- question. You might want to look at
- decreasing the value for sdlcLSAdminMAXDATASend
- to compensate for the lower quality line."
- ::= { sdlcLSStatsEntry 40 }
-
- --
- -- TRAP DEFINITIONS
- --
-
- --
- -- Notifications
- --
-
- sdlcTraps OBJECT IDENTIFIER ::= { sdlc 3 }
-
- sdlcPortStatusChange NOTIFICATION-TYPE
- OBJECTS { ifIndex,
- ifAdminStatus,
- ifOperStatus,
- sdlcPortOperLastFailTime,
- sdlcPortOperLastFailCause
- }
- STATUS current
- DESCRIPTION
- "This trap indicates that the state of an SDLC
- port has transitioned to active or inactive."
- ::= { sdlcTraps 1 }
-
- sdlcLSStatusChange NOTIFICATION-TYPE
- OBJECTS { ifIndex,
- sdlcLSAddress,
- sdlcLSOperState,
- sdlcLSAdminState,
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 56]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSOperLastFailTime,
- sdlcLSOperLastFailCause,
- sdlcLSOperLastFailFRMRInfo,
- sdlcLSOperLastFailCtrlIn,
- sdlcLSOperLastFailCtrlOut,
- sdlcLSOperLastFailREPLYTOs
- }
- STATUS current
- DESCRIPTION
- "This trap indicates that the state of an SDLC
- link station has transitioned to contacted or
- discontacted."
- ::= { sdlcTraps 2 }
-
-
- --
- -- Conformance Information
- --
-
- sdlcConformance OBJECT IDENTIFIER ::= { sdlc 4 }
-
- sdlcCompliances OBJECT IDENTIFIER ::= { sdlcConformance 1 }
- sdlcGroups OBJECT IDENTIFIER ::= { sdlcConformance 2 }
-
- --
- -- Compliance Statements
- --
-
- sdlcCoreCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "The core compliance statement for all SDLC
- nodes."
- MODULE
- MANDATORY-GROUPS
- {
- sdlcCorePortAdminGroup,
- sdlcCorePortOperGroup,
- sdlcCorePortStatsGroup,
- sdlcCoreLSAdminGroup,
- sdlcCoreLSOperGroup,
- sdlcCoreLSStatsGroup
- }
-
- OBJECT sdlcPortAdminName
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 57]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- OBJECT sdlcPortAdminRole
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcPortAdminType
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcPortAdminTopology
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcPortAdminISTATUS
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAddress
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminName
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminState
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminISTATUS
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminMAXDATASend
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminMAXDATARcv
- MIN-ACCESS read-only
- DESCRIPTION
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 58]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- "Write access is not required."
-
- OBJECT sdlcLSAdminMAXIN
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminMAXOUT
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminMODULO
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminRETRIESm
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminRETRIESt
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminRETRIESn
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminRNRLIMIT
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminDATMODE
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminGPoll
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminSimRim
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 59]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminRowStatus
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- ::= { sdlcCompliances 1 }
-
- sdlcPrimaryCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "The compliance statement for all nodes that
- are performing the role of a Primary link
- station."
- MODULE
- MANDATORY-GROUPS { sdlcPrimaryGroup }
-
- OBJECT sdlcPortAdminPAUSE
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcLSAdminREPLYTO
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- ::= { sdlcCompliances 2 }
-
- sdlcPrimaryMultipointCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "The compliance statement for all nodes that
- are performing the role of a primary link
- station on a multipoint line."
- MODULE
- MANDATORY-GROUPS { sdlcPrimaryMultipointGroup }
-
- OBJECT sdlcPortAdminSERVLIM
- MIN-ACCESS read-only
- DESCRIPTION
- "Write access is not required."
-
- OBJECT sdlcPortAdminSlowPollTimer
- MIN-ACCESS read-only
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 60]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- DESCRIPTION
- "Write access is not required."
-
- ::= { sdlcCompliances 3 }
-
-
- --
- -- Core Conformance Groups for All Link Stations
- --
-
- sdlcCoreGroups OBJECT IDENTIFIER ::= { sdlcGroups 1 }
-
- sdlcCorePortAdminGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcPortAdminName, sdlcPortAdminRole,
- sdlcPortAdminType, sdlcPortAdminTopology,
- sdlcPortAdminISTATUS
- }
- STATUS current
- DESCRIPTION
- "The sdlcCorePortAdminGroup defines objects
- which are common to the PortAdmin group of all
- compliant link stations."
- ::= { sdlcCoreGroups 1 }
-
- sdlcCorePortOperGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcPortOperName,
- sdlcPortOperRole,
- sdlcPortOperType,
- sdlcPortOperTopology,
- sdlcPortOperISTATUS,
- sdlcPortOperACTIVTO,
- sdlcPortOperLastFailTime,
- sdlcPortOperLastFailCause
- }
- STATUS current
- DESCRIPTION
- "The sdlcCorePortOperGroup defines objects
- which are common to the PortOper group of all
- compliant link stations."
- ::= { sdlcCoreGroups 2 }
-
-
- sdlcCorePortStatsGroup OBJECT-GROUP
- OBJECTS
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 61]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- {
- sdlcPortStatsPhysicalFailures,
- sdlcPortStatsInvalidAddresses,
- sdlcPortStatsDwarfFrames
- }
- STATUS current
- DESCRIPTION
- "The sdlcCorePortStatsGroup defines objects
- which are common to the PortStats group of all
- compliant link stations."
- ::= { sdlcCoreGroups 3 }
-
-
- sdlcCoreLSAdminGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcLSAddress,
- sdlcLSAdminName,
- sdlcLSAdminState,
- sdlcLSAdminISTATUS,
- sdlcLSAdminMAXDATASend,
- sdlcLSAdminMAXDATARcv,
- sdlcLSAdminMAXIN,
- sdlcLSAdminMAXOUT,
- sdlcLSAdminMODULO,
- sdlcLSAdminRETRIESm,
- sdlcLSAdminRETRIESt,
- sdlcLSAdminRETRIESn,
- sdlcLSAdminRNRLIMIT,
- sdlcLSAdminDATMODE,
- sdlcLSAdminGPoll,
- sdlcLSAdminSimRim,
- sdlcLSAdminRowStatus
- }
- STATUS current
- DESCRIPTION
- "The sdlcCorePortAdminGroup defines objects
- which are common to the PortAdmin group of all
- compliant link stations."
- ::= { sdlcCoreGroups 4 }
-
- sdlcCoreLSOperGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcLSOperRole,
- sdlcLSOperState,
- sdlcLSOperMAXDATASend,
- sdlcLSOperMAXIN,
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 62]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSOperMAXOUT,
- sdlcLSOperMODULO,
- sdlcLSOperRETRIESm,
- sdlcLSOperRETRIESt,
- sdlcLSOperRETRIESn,
- sdlcLSOperRNRLIMIT,
- sdlcLSOperDATMODE,
- sdlcLSOperLastFailTime,
- sdlcLSOperLastFailCause,
- sdlcLSOperLastFailCtrlIn,
- sdlcLSOperLastFailCtrlOut,
- sdlcLSOperLastFailFRMRInfo,
- sdlcLSOperLastFailREPLYTOs,
- sdlcLSOperEcho,
- sdlcLSOperGPoll
- }
- STATUS current
- DESCRIPTION
- "The sdlcCorePortOperGroup defines objects
- which are common to the PortOper group of all
- compliant link stations."
- ::= { sdlcCoreGroups 5 }
-
-
- sdlcCoreLSStatsGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcLSStatsBLUsIn,
- sdlcLSStatsBLUsOut,
- sdlcLSStatsOctetsIn,
- sdlcLSStatsOctetsOut,
- sdlcLSStatsPollsIn,
- sdlcLSStatsPollsOut,
- sdlcLSStatsPollRspsIn,
- sdlcLSStatsPollRspsOut,
- sdlcLSStatsLocalBusies,
- sdlcLSStatsRemoteBusies,
- sdlcLSStatsIFramesIn,
- sdlcLSStatsIFramesOut,
- sdlcLSStatsRetransmitsIn,
- sdlcLSStatsRetransmitsOut,
- sdlcLSStatsUIFramesIn,
- sdlcLSStatsUIFramesOut,
- sdlcLSStatsXIDsIn,
- sdlcLSStatsXIDsOut,
- sdlcLSStatsTESTsIn,
- sdlcLSStatsTESTsOut,
- sdlcLSStatsREJsIn,
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 63]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- sdlcLSStatsREJsOut,
- sdlcLSStatsFRMRsIn,
- sdlcLSStatsFRMRsOut,
- sdlcLSStatsSIMsIn,
- sdlcLSStatsSIMsOut,
- sdlcLSStatsRIMsIn,
- sdlcLSStatsRIMsOut,
- sdlcLSStatsProtocolErrs,
- sdlcLSStatsRNRLIMITs,
- sdlcLSStatsRetriesExps
- }
- STATUS current
- DESCRIPTION
- "The sdlcCorePortStatsGroup defines objects
- which are common to the PortStats group of all
- compliant link stations."
- ::= { sdlcCoreGroups 6 }
-
-
- --
- -- Conformance Groups for Primary Link Stations
- --
-
- sdlcPrimaryGroups OBJECT IDENTIFIER ::= { sdlcGroups 2 }
-
- sdlcPrimaryGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcPortAdminPAUSE,
- sdlcPortOperPAUSE,
- sdlcLSAdminREPLYTO,
- sdlcLSOperREPLYTO
- }
- STATUS current
- DESCRIPTION
- "The sdlcPrimaryGroup defines objects which
- are common to all compliant primary link
- stations."
- ::= { sdlcPrimaryGroups 1 }
-
- sdlcPrimaryMultipointGroup OBJECT-GROUP
- OBJECTS
- {
- sdlcPortAdminSERVLIM,
- sdlcPortAdminSlowPollTimer,
- sdlcPortOperSlowPollMethod,
- sdlcPortOperSERVLIM,
- sdlcPortOperSlowPollTimer
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 64]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- }
- STATUS current
- DESCRIPTION
- "The sdlcPrimaryMultipointGroup defines objects
- which are common to all compliant primary link
- stations that are in a multipoint topology."
- ::= { sdlcPrimaryGroups 2 }
-
-
- END
-
- 4. Acknowledgments
-
- Thanks goes to the SNADLC MIB working group for reviewing this MIB
- and for their infinite patience through the editing process.
-
- 5. References
-
- [1] Stewart, B., "Definitions of Managed Objects for RS-232-like
- Hardware Devices using SMIv2", RFC 1659, Xyplex, July 1994.
-
- [2] "Synchronous Data Link Control: Concepts", IBM Publication No.
- GA27-3093-04, 5th edition, May 1992.
-
- [3] "Vocabulary for Data Processing Telecommunications, and Office
- Systems", IBM Publication No. GC20-1699-6.
-
- [4] Kostick, D., Kielczewski, Z., and K. Shih, Editors, "Definitions
- of Managed Objects for SNA NAUs using SMIv2", RFC 1666, Eicon
- Technology Corporation, Bell Communications Research, Novell,
- August 1994.
-
- [5] Waldbusser, S., "Row Creation with SNMPv1", Work in Progress.
-
- [6] McCloghrie K., and F. Kastenholz, "Evolution of the Interfaces
- Group of MIB-II", RFC 1573, Hughes LAN Syst, FTP Software,
- January 1994.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 65]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- 6. Glossary
-
- link station
- A link station comprises procedures and control information
- that coordinate the transfer of data between two nodes joined
- by a link connection. All traffic over the link connection is
- from the primary link station to one or more secondary link
- stations, or from a secondary link station to the primary link
- station.
-
- primary link station
- The link station instance on a link connection that is
- responsible for the control of the data link. There must be
- only one primary link station on a link connection. The
- primary link station issues commands to one or more secondary
- link stations.
-
- secondary link station
- The link station instance on a link connection that receives
- commands from the primary link station and issues responses to
- it.
-
- switched line
- A telecommunications line in which the connection is
- established by dialing. For switched lines, the SDLC startup
- sequence typically begins with a null exchange identifier (null
- XID).
-
- leased line
- A telecommunications line on which connections do not have to
- be established by dialing. For leased lines, the SDLC startup
- sequence may or may not begin with an exchange identifer (XID).
- While there are interface (e.g., RS.232) differences between
- leased and switched lines, those interface differences do not
- map one-to-one with differences in the SDLC startup protocol
- (i.e., the interface and the SDLC protocol are independent from
- one another).
-
- point-to-point link
- A link that connects the single primary link station to single
- secondary link station. A point-to-point link may be either
- switched or leased.
-
- multipoint link
- A link that connects the single primary link station to several
- secondary link stations. A multipoint link may be either
- switched or leased. Note: The physical interface signals for a
- multipoint link are different than for a point-to-point link.
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 66]
-
- RFC 1747 SNADLC SDLC MIB using SMIv2 January 1995
-
-
- Synonymous with multidrop line.
-
- 7. Security Considerations
-
- Security issues are not discussed in this memo.
-
- 8. Authors' Addresses
-
- Jeff Hilgeman (chair)
- Apertus Technologies, Inc.
- 7275 Flying Cloud Dr.
- Eden Prarie, MN 55344
-
- Phone: 1 612 828 0668
- EMail: jeffh@apertus.com
-
-
- Shannon D. Nix
- Metaplex, Inc.
- 7412 Wingfoot Dr.
- Raleigh, NC 27615
-
- Phone: 1 919 878 0811
- EMail: snix@metaplex.com
-
-
- Alan Bartky
- Sync Research, Inc.
- 7 Studebaker
- Irvine, CA 92718
-
- Phone: 1 714 588 2070
- EMail: alan@sync.com
-
-
- Wayne Clark (editor)
- cisco Systems, Inc.
- 3100 Smoketree Ct.
- Suite 1000
- Raleigh, NC 27604
-
- Phone: 1 919 878 6958
- EMail: wclark@cisco.com
-
-
-
-
-
-
-
-
- Hilgeman, Nix, Bartky & Clark [Page 67]
-
-