home *** CD-ROM | disk | FTP | other *** search
- !WHACKOLAND!WHACKOLAND!
- W HACKING RAMPART W
- H SYSTEMS H
- A A
- C PART II..... C
- K K
- O IN DEPTH O
- L DESCRIPTIONS OF L
- A COMMANDS A
- N & N
- D SUB-CMDS D
- !WHACKOLAND!WHACKOLAND!
-
-
- THIS IS THE SECOND PART OF IN-DEPTH
- COMMAND & SUB COMMAND'S. READ PART I
- OF HACKING RAMPART SYSTEMS BEFORE THIS.
-
- ->PUT
-
- THESE COMMANDS ALTER THE CONFIGURATION
- OF RAMPART EQUIPMENT
-
- FORMAT: PUT (OR PLACE) QUALIFIER IN
- (OR OUT OF SERVICE)
-
- ] PUT(OR PLACE) SUB CMDS [
-
- TESTLINE
- PORT
- ROTL
-
- ->PUT TESTLINE
-
- PUT TYPE TESTLINE (AT) CENTRAL^OFFICE
- IN (OR OUT OF SERVICE)
-
- MAKES A TESTLINE AVAILABLE OR UN-
- AVAILABLE FOR TESTING BY RAMPART (HAS
- NO PHYSICAL EFFECT ON THE EQUIPMENT
- ITSELF.)
-
- O POSSIBLE TESTLINE TYPES: 100, 102,
- 103, 104, 105
-
- O CENTRAL^OFFICE CAN BE A COMMON
- LANGUAGE CODE OR A LITERAL CENTRAL
- OFFICE NAME (CON).
-
- ->PUT PORT
-
- PUT PORT NUMBER (OR ALL) QUALIFIER
-
- ALTERS THE CONFIGURATION OF RAMPART
- TEST PORTS.
-
- ->PUT PORT SUB CMDS
-
- IN OUT
- PBX
- WATS
- DTMF DP
-
- ->PUT PORT NUMBER (OR ALL) <TO> PBX
- (OR NO PBX)
-
- ENABLES OR DISABLES DIALING '9' AND
- WAITING FOR DIAL TONE BEFORE DIALING
- ROTL ACCESS NUMBERS.
-
- ->PUT PORT WATS
-
- PUT PORT NUMBER (OR ALL) <TO> WATS (OR
- NO WATS)
-
- ENABLES OR DISABLES DIALING '8' AND
- WAITING FOR DIAL TONE BEFORE DIALING
- ROTL ACCESS NUMBERS
-
- ->PUT PORT DTMF
-
- PUT PORT NUMBER (OR ALL) <TO DTMF>
- (OR NO DP) CAUSES THE SPECIFIED PORT(S)
- TO USE DIAL PULSE OUTDIALING
-
- ->DISPLAY
-
- THESE COMMANDS RETURN A DISPLAY TO THE
- USER OF SYSTEM PARAMETERS AND STORED
- TEST RESULTS.
-
- FORMAT: DISPLAY (OR SHOW) QUALIFIER
-
- ABBREVIATIONS: DP,?
-
- ->DISPLAY SUB CMDS
-
- ROTL
- TESTLINE
- PORT
- RES-ULTS
- DEMAND
- TRUNK
- RUT
-
- ->TERMINAL
-
- TERMINL <(IS) TERMINAL@TYPE>
-
- DISPLAYS THE DEVICE NUMBER OF THE
- TERMINAL CURRENTLY IN USE & OPTIONALLY
- DEFINES THE TERMINAL USER'S TERMINAL
- TYPE.
-
- VALUES FOR 'TERMINAL@TYPE':CRT, NO CRT,
- VT100, VT101, VT131, VT125 (USE 'NO
- CRT' FOR HARD COPY TERMINALS. NO CRT IS
- THE DEFAULT WHEN LOGGING IN ON REMOTE
- TERMINALS)
-
- NOTE: THE CORRECT TERMINAL TYPE MUST BE
- DEFINED TO ENABLE CERTAIN PLOTS AND
- GRAPHS ON THE RAMPART SYSTEM.
-
- ->TEST
-
- THIS CLASS OF CMDS ENABLES THE RAMPART
- USER TO PERFORM DEMAND TESTS. IF ALL
- TEST PORTS ARE IN USE, DEMAND REQUESTS
- ARE PUT INTO THE DEMAND QUEUE & TESTED
- IN 'FIRST IN - FIRST OUT' ORDER.
-
- FORMAT: TEST TESTLINE (FROM) NEAREND
- (TO) FAREND (ON GROUP) GROUP ID
- <(ON TRUNKS)TRUNK NUMBERS> >PERFORMING
- TESTS>SWITCHES>
-
- TEST TESTLINE REFERRRAL NUMBER <(ON
- TRUNKS) TRUNK NUMBERS><(PERFORMING)
- TESTS> <SWITCHES>
-
- O 'TESTLINE' DEFAULTS TO 105 IF NOT
- SPECIFIED.
-
- O 'TRUNK NUMBERS' DEFAULT TO ENTIRE
- TRUNK GROUP IF NOT SPECIFIED
-
- O 'TESTS' DEFAULT TO 2-WAY LOSS AND
- NOISE.
-
- ->TEST SUB CMD'S
-
- NEAREND FAREND
- TESTLINE
- TESTS
- SWITCHES
- TRUNK@NUMBERS
- REP-EAT
-
- THE TESTS THE THE RAMPART SYSTEM IS
- CAPABLE TO PERFORM ARE:
-
- 'L'=TWO WAY LOSS AT 1004 HZ
- 'L4'=TWO WAY LOSS AT 404 HZ,-16 DB
- 'L10'=TWO WAY LOSS AT 1004 HZ, -16 DB
- 'L28'=TWO WAY LOSS AT 2804 HZ, -16 DB
- 'N'=NEAR TO FAR NOISE
- 'RN'=FAR TO NEAR NOISE
- 'NT'=TWO WAY NOISE WITH TONE
- 'ERL'=ECHO RETURN LOSS
- 'SRL'=SINGING RETURN LOSS
- 'SRLHI'=HIGH SINGING RETURN LOSS
-
- 'ALL' PERFORMS ALL TESTS AVAILABLE ON
- FAREND RESPONDER SPECIFIED.
-
- AVAILABLE SELFCHECKS:
- 'LSC', 'LSC4', 'LSC10', 'LSC28', 'NSC'
- 'RNSC','NTSC', 'ERLSC', 'SRLSC','SHISC'
-
- ->REPORT RUT
-
- ALLOWS THE USER TO SPECIFY REPORTING ON
- ALL THE SPECIFIED RUT PW IN THE DB.
- IF THE RUT PW IS NOT SPECIFIED IN THE
- CMD LINE, THE USER IS PROMPTED FOR THE
- RUT PW TO USE IN REPORT SELECTION
- (RUT IS A ACRONYM FOR REMOTE USER
- TERMINAL)
-
- EXAMPLE: 'REPORT RUT AAA'
- 'REPORT RUT' (PROMPTS FOR RUT
- PW)
-
- -> REPORT RUT TESTS
-
- ORIGINATING TERMINAL TT4:
-
- DEMAND TEST-TRUNK GROUP DALTER2004,CINDSROTL TO DALCTSSROTL
- EML @NE @FE 0.0
- Q1 LOSS LIMIT 2.0 Q2 LOSS LIMIT 04.0
- Q1 ERL LIMIT 00. Q2 ERL LIMIT 00.
- Q1 NOISE LIMIT 44. Q2 NOISE LIMIT 47.
- Q1 NTONE LIMIT 44. Q2 NTONE LIMIT 47.
-
- PORT 2, 20-NOV-85 00:21:00 REF PFX:100
- TRANSMISSION 105 TEST (RESULTS STORED)
- ROTL ACCESS: 3217006
-
- TRUNK1/ 6001 > 00:22:06 KP 05200460010003214007 ST
- L F-N -06.1 N-F -00.1
- RN F-N * *
-
- THESE TESTS ARE BEING ROUTED THROUGH
- EITHER THE WATS OR PBX, OR NO PBX. YOU
- CAN TOGGLE THESE.
-
- !WHACKOLAND!WHACKOLAND!
- ! !
- T LOOK FOR PART III.. T
- >T< W HACKING RAMPART W
- C CL 1, CL2, CL3 C
- B MAIN SYSTEM B
- ! (314) 256 8220 !
- !WHACKOLAND!WHACKOLAND!
-