  2.                   INSTALLING HS/LINK EXTERNAL PROTOCOL
  3.                            IN Virtual BBS 5.4
  4.  
  5.      Please refer to the RemoteAccess manual for detailed information on
  6.      installation of external protocols.  This information was tested
  7.      with HS/Link version 1.00 and Virtual BBS version 5.40.
  8.  
  9.      Virtual BBS version 5.4 comes pre-installed for HS/Link.  Follow
  10.      these instructions if you wish to verify HS/Link installation, or
  11.      to make changes.  It also adds a single direction "upload" mode for
  12.      HS/Link.
  13.  
  14.      Place a copy of HSLINK.EXE into your main C:\VBBS directory, or
  15.      some other directory in your PATH list.
  16.  
  17.      Run VCONFIG.EXE and press 6 for DOWNLOAD PROTOCOLS.
  18.  
  19.      The download definition of the HS/Link should look like this:
  20.  
  21.   [DOWNLOAD PROTOCOLS]
  22.  
  23.   Key Name                     Command Line (download protocols) (*=batch)
  24.   --- ------------------------ ------------------------------------------------
  25.   *H  HSLINK (Bidirectional)   HSLINK -p%1 -e%2 -UC:\VBBS\SYSOP %3
  26.  
  27.      In place of C:\VBBS\SYSOP substitute your own upload directory, if
  28.      you use a different name for it.
  29.  
  30.      The bi-directional transfers only work when the Download command is
  31.      used because you cannot request files to be received.  You may want
  32.      to explain to your users that they will need to describe any files
  33.      they upload while downloading AFTER the transfer is completed.
  34.  
  35.      Return to the main menu of VCONFIG and select 7 for UPLOAD
  36.      PROTOCOLS.
  37.  
  38.   [UPLOAD PROTOCOLS]
  39.  
  40.   Key Name                     Command Line (upload protocols) (*=batch)
  41.   --- ------------------------ ------------------------------------------------
  42.   *H  HSLINK                   HSLINK -p%1 -e%2 -u%3
  43.  
  44.      Note for systems running locked COM ports:
  45.      We have found that if you use a locked DTE of 9600 or above, you
  46.      will need to have a NS16550AN UART installed.  Also, for rock solid
  47.      performance you should add the -HS (Handshake Slow) switch to your
  48.      upload and download command lines.
  49.  
  50.      This should get you set up in under 10 minutes.
  51.  
  52.      You can edit the download and upload command lines to include
  53.      options on the HSLINK command line, but most folks won't need to
  54.      change anything.  If your system can't keep up with the COM port
  55.      while accessing the disk drive, you may want to add -HS to both
  56.      lines.  If you want to experiment, there are a number of optional
  57.      parameters you can read about in HSLINK.DOC and HSLINK.NEW.
  58.  
  59.      I hope these instructions help, but remember, I can't take
  60.      responsibility for any damages resulting from these instructions.
  61.      If you get stuck, it always helps to read the DOC files that come
  62.      with RemoteAccess and with HS/Link.  If all else fails, call up the
  63.      Tool Shop and ask for help on the Support Conference.  Either I
  64.      will help you, or somebody else will know the answer and give you a
  65.      hand.
  66.  
  67.      Good luck!
  68.  
  69.      Samuel H. Smith
  70.      Sysop of The Tool Shop
  71.  
  72.         Phone number         Modem type                Access
  73.        --------------    ---------------------   -------------------
  74.        (818) 891-3772    US Robotics HST 9600    Contributors only
  75.        (818) 891-1344    Hayes-V series 9600     Contributors only
  76.        (818) 891-6780    US Robotics 2400        Free to all
  77.