  1. DOCUMENT:Q108236  09-DEC-1993  [W_NT]
  2. TITLE   :Problems Using IPX and NWLINK with the IBM 8029 LAN Bridge
  3. PRODUCT :Windows NT
  4. PROD/VER:3.10
  5. OPER/SYS:WINDOWS
  6. KEYWORDS:
  7.  
  8. --------------------------------------------------------------------------
  9. The information in this article applies to:
  10.  
  11.  - Microsoft Windows NT operating system version 3.1
  12.  - Microsoft Windows NT Advanced Server version 3.1
  13. --------------------------------------------------------------------------
  14.  
  15. SYMPTOMS
  16. ========
  17.  
  18. When you use the IBM 8209 LAN Bridge Attachment Module for Ethernet Version
  19. 2 and IEEE 802.3 LANs (Ethernet attachment module) which allows devices on
  20. an Ethernet or IEEE 802.3 LAN segment to communicate with devices on an IBM
  21. Token Ring Network segment through an IBM 8209 LAN Bridge, you may have
  22. problems passing IPX or NWLINK traffic. (An example would be the inability
  23. to make a connection when you are using Windows NT as a server for an SQL
  24. Server application.)
  25.  
  26. CAUSE
  27. =====
  28.  
  29. This problem can be caused by not having the correct filters set on the IBM
  30. 8209, or it can be caused by a hardware issue with the 8209. Earlier IBM
  31. 8209 Bridge Ethernet Attachment Modules had problems with IPX traffic. To
  32. determine if the IBM 8209 Ethernet Module is the earlier hardware, run the
  33. 8209 utility that came with the bridge; the utility can also be downloaded
  34. from DIR 32 of the IBM bulletin board at (919) 517-0007. If this utility
  35. does not show an option for IPX enabled, then the IBM 8209 with Ethernet
  36. Module is an earlier version (because the engineering change was made in
  37. recent years, it is still possible to run across a "new" bridge that is
  38. actually the earlier hardware).
  39.  
  40. RESOLUTION
  41. ==========
  42.  
  43. To resolve this problem, make sure you are not using filters to filter IPX
  44. traffic across the bridge, and/or call IBM at (800) 426-7378 to update your
  45. IBM 8209 Bridge Ethernet Attachment Module.
  46.  
  47. The IBM products included here are manufactured by a vendor independent of
  48. Microsoft; we make no warranty, implied or otherwise, regarding these
  49. products' performance or reliability.
  50.  
  51. Additional reference words: 3.10
  52. KBCategory:
  53. KBSubcategory: netsrv
  54.  
  55.  
  56. =============================================================================
  57.  
  58. THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS
  59. PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.  MICROSOFT DISCLAIMS
  60. ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES
  61. OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  IN NO
  62. EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR
  63. ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL,
  64. CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF
  65. MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE
  66. POSSIBILITY OF SUCH DAMAGES.  SOME STATES DO NOT ALLOW THE EXCLUSION
  67. OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES
  68. SO THE FOREGOING LIMITATION MAY NOT APPLY.
  69.  
  70. Copyright Microsoft Corporation 1993.