home *** CD-ROM | disk | FTP | other *** search
/ Black Box 4 / BlackBox.cdr / textinfo / wd_2awx1.arj / WD_A2X12.DOC < prev    next >
Encoding:
Text File  |  1989-06-24  |  7.3 KB  |  156 lines

  1.  
  2.      Western Digital is a registered trademark of Western Digital 
  3.      Corporation; IBM PC, AT and XT are registered trademarks of the 
  4.      International Business Machines Corporation; MS DOS, OS2 and PC DOS 
  5.      are registered trademarks of Microsoft Corporation.
  6.  
  7.                                    WD1002A-WX1
  8.                                    User Guide
  9.  
  10.      Getting Started:
  11.  
  12.      Installation of the WD1002A-WX1 requires four steps:  1) Confirming 
  13.      BIOS ROM type; 2) Checking or setting jumpers;  3) installing into 
  14.      host computer; 4) formatting the disk drives.  To complete 
  15.      installation, you will need the following:
  16.  
  17.      Two cables (3 if using two drives); MFM type drive; screwdriver; 
  18.      MSDOS Version 2.0 or later; *DEBUG utility; *FDISK utility; *FORMAT 
  19.      Utility.  (*normally included with MSDOS); 
  20.  
  21.                                      WARNING
  22.                  HANDLE THE CONTROLLER BY THE ENDS OF THE BOARD
  23.                 SOME OF THE CHIPS ARE STATIC SENSITIVE AND DAMAGE
  24.                   MAY OCCUR IF THE BOARD IS INCORRECTLY HANDLED
  25.  
  26.                                  Confirming BIOS
  27.  
  28.      At location U12, please confirm that your WD1002A-WX1 BIOS ROM is 
  29.      part number 62-000094-followed by any three numbers  (this BIOS ROM 
  30.      is referred to as Western Digital's SUPERBIOS).  If your controller 
  31.      has any other BIOS, contact Technical Support at 1-800-777-4787.
  32.  
  33.      Prepare Controller
  34.  
  35.                       ┌───Drive 0──────────────────────────┐
  36.                       │ Data Cable   34pin Control Cable   │
  37.                       │  ┌──J2──┐    ┌──────J1───────┐     │
  38.                 ┌─────┘  └──────┘    └───────────────┘     │
  39.                 │        ┌──J3──┐                          │
  40.                 │        └──────┘                  123     │
  41.                 │         Drive 1            ┌U2─┐ ∙∙∙W8   │
  42.                 │       Data Cable           └───┘ ∙∙∙W4   │
  43.                 │                             ∙1           │
  44.                 │                          W6 ∙2    ∙∙5    │
  45.                 │         BIOS                ∙3    ∙∙6    │
  46.                 │       ┌──────────┐                ∙∙7    │
  47.                 │       │          (                ∙∙8 S1 │
  48.                 │       └──────U12─┘                ∙∙4    │
  49.                 │                                   ∙∙3    │
  50.                 └─┐           ┌─┐                   ∙∙2    │
  51.                   │           └┘                   ∙∙1    │
  52.                   └──────┐A31  J4                 A1┌──────┘
  53.                          │        WD1002A-WX1       │      
  54.                          └┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┘      
  55.                                  Jumper Settings
  56.  
  57.      Verify that the host computer contains a 135 watt power supply.  
  58.      Verify that the jumper settings on the controller board are correct.  
  59.      Modification of factory jumper settings is rarely necessary.  For 
  60.      jumper settings on W4, W6 and W8, refer to Table 1; Jumper settings 
  61.      for S1 are located on Table 2.
  62.  
  63.      CLOSED:  Jumper (small shorting pens) is installed
  64.      OPEN:    Jumper is not installed.
  65.  
  66.                                      Table 1
  67.  
  68.                 Pin
  69.      Jumper     Connects   Status
  70.  
  71.      W3         Closed     BIOS ROM Enabled
  72.                 Open       BIOS ROM Disabled
  73.  
  74.      W4         2-3        Device Address 320H
  75.                 2-1        Device Address 324H
  76.      W6         2-3        Reduced Write Curent (8 Heads)
  77.                 2-1        Head Sel 3 (16 heads)
  78.      W8         2-3        Standard factory setting.  First or only
  79.                            disk controller in system.
  80.                 1-2        Second disk controller in system.  Requires
  81.                            modification of W4.
  82.  
  83.      The following S1 jumper settings are for standard 10/20 megabyte hard 
  84.      disk drives using default settings in the SUPERBIOS.  If you are 
  85.      using a standard 10/20 megabyte drive, you may refer to the 
  86.      Simplified Formatting Instructions after completing the hardware 
  87.      installation procedures.  If your drive is a non-standard drive (i.e. 
  88.      20 megabyte drives with other than 4 heads/615 cylinders, or hard 
  89.      disk drives with a formatted capacity greater than 20 megabytes) you 
  90.      will need to refer to the Dynamic Formatting instructions after 
  91.      completing the hardware installation procedure.  
  92.  
  93.      If you do not know your drive parameters, return to the STORAGE 
  94.      CONTROLLERS menu to access a listing of the most common drives and 
  95.      their parameters which we have provided for your convenience.  If 
  96.      your drive is not listed, refer to your drive manual or contact the 
  97.      manufacturer.
  98.  
  99.                                      Table 2
  100.                                S1 Jumper Settings
  101.  
  102.                            10Meg Drive     10 Meg Drive       Standard
  103.                            4Hds/306 Cyl    2Hds/615 Cyl       20Meg Drive
  104.  
  105.      S1-1                  Open            Closed             Open
  106.      S1-2                  Closed          Open               Open
  107.      S1-3                  Open            Closed             Open
  108.      S1-4                  Closed          Open               Open
  109.      S1-5                  Open            Open               Open
  110.      S1-6                  Open            Open               Open
  111.      S1-7                  Open            Open               Open
  112.      S1-8*                 Open            Open               Open
  113.      S1-8**                Closed          Closed             Closed
  114.  
  115.      *XT Mode
  116.      **AT Mode
  117.  
  118.      Now that you have verified the jumper settings, you are ready to 
  119.      install the controller and drive into your host computer.
  120.  
  121.                                      WARNING
  122.                         MAKE SURE COMPUTER IS TURNED OFF
  123.                            AND POWER IS DISCONNECTED 
  124.  
  125.                   Installation of Controller into Host Computer
  126.  
  127.      Remove blank expansion slot bracket and save for future use.  The 
  128.      screw will be used to hold the controller board into place.  
  129.  
  130.      INSTALL CONTROLLER INTO ANY AVAILABLE SLOT EXCEPT SLOT 8  
  131.  
  132.      Connect the 34-pin (wide control cable) connector to J1 on the 
  133.      controller board.  Make sure that Pin 1 of the cable connector goes 
  134.      to Pin 1 on the controller board.  Pin 1 of the cable connector is 
  135.      typically located on the color coded side of the cable.
  136.  
  137.      Connect the 20-pin (data cable) to J2 (Drive 0 Data Connector) on the 
  138.      controller board.  Make sure that Pin 1 on the cable is connected to 
  139.      Pin 1 on the controller board.
  140.  
  141.      If a second drive is being installed, connect the Drive 1 data cable 
  142.      to J3.
  143.  
  144.      Verify that the disk drive(s) is(are) installed properly.  This 
  145.      includes correct placement of drive select jumpers and drive 
  146.      terminator installation.  Refer to the disk drive installation manual 
  147.      for further information.  DO NOT USE THE RADIAL SELECT OPTION.
  148.  
  149.      Install the drive(s) per manufacturer's instructions.
  150.  
  151.                                      CAUTION
  152.                 WHEN ROUTING CABLES, BE CAREFUL NOT TO PINCH
  153.                 THEM.  CABLES MUST NOT GET CAUGHT BETWEEN THE
  154.                 COVER AND THE BOARDS, NOR SHOULD THEY OBSTRUCT
  155.                 ANY AIR FLOW PATH FROM FANS OR VENTS.
  156.