  1.  PW2 500/20A                                                           F-273 
  2.  by Unisys Corporation                                    (Previously S-330) 
  3.  18 JUN 1990                                                                 
  4.  
  5.  
  6. Tested and Approved NetWare compatible as a File server/Workstation with the
  7. following Novell products:
  8.  
  9.   UserNet ELS Level II (v2.15 rev. c)  NetWare for Macintosh (v1.1)
  10.   Advanced NetWare (v2.15 rev. c)      NetWare SNA Gateway Token-Ring (v1.1)
  11.   SFT NetWare (v2.15 rev. c)           NetWare SQL (v2.01b)
  12.   NetWare 386 (v3.0)                   
  13.  
  14. Product Configuration:
  15.  
  16. Product Name/Model/Rev:      PW2 500/20A
  17. CPU Family/Clock Speed:      80386/20 MHz
  18. Controller(s)/Fixed Disk(s): AHA-1542A Rev. D
  19.                              Type SCSI (40 MB)  Quantum 40S
  20. Bus Type:                    ISA (One 8-bit slot, four 16-bit slots)
  21. ROM BIOS Version:            80386 ROM BIOS Plus Ver 1.10 03 (Phoenix)
  22. Main/CPU Board Revision:     650-0139-06E
  23. CPU Memory:                  Base  640               Extended  3072
  24. Video Adapter                VGA
  25. Vendor Software:             MS DOS (4.01)
  26.  
  27. Configuration Notes:
  28.  
  29.    Two floppy disk controllers are available; one on the I/O card, another on
  30.    the SCSI disk controller. The floppy controller on the SCSI disk
  31.    controller was used throughout testing.
  32.  
  33.    The floppy disk controller on the I/O card is unable to consistently read
  34.    the floppy diskette while the machine is running nondedicated with a SCSI
  35.    hard disk controller.
  36.  
  37.    UserNet ELS Level II is available from Unisys Corp. with a prelinked SCSI
  38.    disk driver.
  39.  
  40. For more information regarding the specifics of the product's tested
  41. configuration, please contact Unisys Corporation or Novell Product Information.
  42. Novell Labs certification only applies to the exact configuration documented in
  43. this bulletin. 
  44.  
  45.                          Unisys Corporation
  46.                          500 US Highway 202 North
  47.                          Flemington, NJ  08822
  48.                          (908) 788-4000
  49.  