  9.  
  10.  
  11.  
  12.                          BTU Heating/Cooling Analysis
  13.  
  14.  
  15.  
  16.  
  17.  
  18.  
  19.  
  20.  
  21.                                  Prepared by:
  22.  
  23.                                A to Z Unlimited
  24.                               901 Ferndale Blvd.
  25.                              High Point, NC 27262
  26.  
  27.  
  28.  
  29.  
  30.  
  31.  
  32.  
  33.                           Date Prepared: 01-29-1990
  34.  
  35.  
  36.  
  37.  
  38.  
  39.  
  40.  
  41.                                 Prepared for:
  42.  
  43.                                    John Doe
  44.                               1234 Anywhere Ct.
  45.                              High Point, NC 27260
  46.  
  47.                                   Page 1 of 3
  48.  
  49.                          BTU Heating/Cooling Analysis
  50.  
  51.  
  52.    01-29-1990
  53.  
  54.    A to Z Unlimited
  55.    901 Ferndale Blvd.
  56.    High Point, NC 27262
  57.  
  58.  
  59. ****************************************************************************
  60. ****************************************************************************
  61.  
  62.    This analysis prepared especially for: John Doe
  63.  
  64.    John Doe
  65.    1234 Anywhere Ct.
  66.    High Point, NC 27260
  67.  
  68.  
  69.                           *********** HEATING ***********
  70.  
  71.        The heating outside design temperature is  10 degrees fahrenheit.
  72.        The heating  inside design temperature is  72 degrees fahrenheit.
  73.        The heating  temperature  differential is  62 degrees fahrenheit.
  74.  
  75.    The heat loss for this building is      91,496 BTU's.
  76.  
  77.    The heating unit must handle   1,039 CFM's for proper heating.
  78.  
  79.    Any heating unit must be rated as close as possible to the heat loss
  80.    calculated in this study, but not less than that amount.
  81.  
  82.    The above CFM allows an 80 degrees rise in inlet to outlet air temperature.
  83.  
  84.  
  85.                           *********** COOLING ***********
  86.  
  87.        The cooling outside design temperature is  95 degrees fahrenheit.
  88.        The cooling  inside design temperature is  72 degrees fahrenheit.
  89.        The cooling  temperature  differential is  23 degrees fahrenheit.
  90.  
  91.    The heat gain for this building is      35,665 BTU's.
  92.  
  93.           This translates into       3.0 tons of cooling.
  94.  
  95.    The preferred cooling CFM is   1,069 CFM's for proper cooling.
  96.  
  97.                  For high humidity areas use       891 CFM's
  98.                  For normal humidity areas use   1,069 CFM's
  99.                  For low humidity areas use      1,248 CFM's
  100.  
  101.    Any cooling unit must be rated as close as possible to the heat gain
  102.    calculated in this study, but not less than that amount.
  103.  
  104. ****************************************************************************
  105.    The writers of the software that was used in generating the above in-
  106.    formation assumes no responsibilities for any losses that may be 
  107.    incurred by the use of the above information.
  108.  
  109.                                   Page 2 of 3
  110.  
  111.                          BTU Heating/Cooling Analysis
  112.  
  113.  
  114.    01-29-1990
  115.  
  116.    John Doe
  117.    1234 Anywhere Ct.
  118.    High Point, NC 27260
  119.  
  120.  
  121. ****************************************************************************
  122. ****************************************************************************
  123.  
  124.  
  125.      *********** Structural analysis is based on the following data ***********
  126.  
  127.    Based on 1055 square feet, total exposed outside wall area.
  128.  
  129.        Wall construction is : Frame wall w/R-11. 
  130.        The wall has a heat transfer factor of .07 heating or cooling.
  131.  
  132.    Based on 2 doors, assuming 20 square feet per door.
  133.  
  134.        Door construction is : Solid wood, no storm.
  135.        The door has a heat transfer factor of .713 heating and .46 cooling.
  136.  
  137.    Based on 23 windows, assuming 15 square feet per window.
  138.  
  139.        All window construction is : Single glazed, plain, no storm. 
  140.        All windows have a heating factor of  1.505 
  141.  
  142.    There are 5 windows facing north, with a cooling factor of 30 
  143.    There are 0 windows facing northeast/west, with a cooling factor of 65 
  144.    There are 13 windows facing east/west, with a cooling factor of 90 
  145.    There are 0 windows facing southeast/west, with a cooling factor of 80 
  146.    There are 5 windows facing south, with a cooling factor of 50 
  147.  
  148.    Based on 1800 square feet total floor area.
  149.  
  150.    The foundation is : Over uncond. basement/enclosed crawl. 
  151.    The floor has a heat transfer factor of .312 heating and 0 cooling.
  152.  
  153.    The ceiling is : Ceiling under/vent. attic/uncond. room. 
  154.    Ceiling insulation is : R-11. 
  155.    The ceiling has a heat transfer factor of .088 heating and .083 cooling.
  156.  
  157.  
  158.  
  159.  
  160.  
  161.  
  162.  
  163.  
  164.  
  165.  
  166.  
  167. ****************************************************************************
  168.    All heat gain factors above are for a 20 degree differential; all cal-
  169.    culated values are corrected for the applicable temperatures.
  170.  
  171.                                   Page 3 of 3
  172.  
  173.                          BTU Heating/Cooling Analysis
  174.  
  175.  
  176.    01-29-1990
  177.  
  178.    John Doe
  179.    1234 Anywhere Ct.
  180.    High Point, NC 27260
  181.  
  182.  
  183. ****************************************************************************
  184. ****************************************************************************
  185.  
  186.                           *********** HEATING ***********
  187.  
  188.                  Total wall heat loss of         4,578 BTU's.
  189.  
  190.                  Total window heat loss of      32,191 BTU's.
  191.  
  192.                  Total Door heat loss of         1,768 BTU's.
  193.  
  194.                  Total floor heat loss of       34,819 BTU's.
  195.  
  196.                  Total ceiling heat loss of      9,820 BTU's.
  197.  
  198.                           *********** COOLING ***********
  199.  
  200.      Total wall heat gain of         1,477 BTU's.
  201.  
  202.      Total window heat gain of       2,250 BTU's, NORTHERN exposure.
  203.      Total window heat gain of           0 BTU's, NORTHWEST/EAST exposure.
  204.      Total window heat gain of      17,550 BTU's, EAST/WEST exposure.
  205.      Total window heat gain of           0 BTU's, SOUTHEAST/WEST exposure.
  206.      Total window heat gain of       3,750 BTU's, SOUTHERN exposure.
  207.  
  208.      Total Door heat gain of           368 BTU's.
  209.  
  210.      Total floor heat gain of            0 BTU's.
  211.  
  212.      Total ceiling heat gain of      2,987 BTU's.
  213.  
  214.      Appliance heat gain of          1,600 BTU's.
  215.  
  216.      Bedroom misc. heat gain of      1,840 BTU's
  217.  
  218.  
  219.  
  220.  
  221.  
  222.  
  223.  
  224.  
  225.  
  226. ****************************************************************************
  227.    All heat gain amounts above, are for a 20 degree differential; all cal-
  228.    culated values are corrected for the applicable temperatures.