  1.  
  2.                                   Page 1 of 1
  3.  
  4.                          BTU Heating/Cooling Analysis
  5.  
  6.  
  7.    01-29-1990
  8.  
  9.    A to Z Unlimited
  10.    901 Ferndale Blvd.
  11.    High Point, NC 27262
  12.  
  13.  
  14. ****************************************************************************
  15. ****************************************************************************
  16.  
  17.    This analysis prepared especially for: John Doe
  18.  
  19.    John Doe
  20.    1234 Anywhere Ct.
  21.    High Point, NC 27260
  22.  
  23.  
  24.                           *********** HEATING ***********
  25.  
  26.        The heating outside design temperature is  10 degrees fahrenheit.
  27.        The heating  inside design temperature is  72 degrees fahrenheit.
  28.        The heating  temperature  differential is  62 degrees fahrenheit.
  29.  
  30.    The heat loss for this building is      79,616 BTU's.
  31.  
  32.    The heating unit must handle     904 CFM's for proper heating.
  33.  
  34.    Any heating unit must be rated as close as possible to the heat loss
  35.    calculated in this study, but not less than that amount.
  36.  
  37.    The above CFM allows an 80 degrees rise in inlet to outlet air temperature.
  38.  
  39.  
  40.                           *********** COOLING ***********
  41.  
  42.        The cooling outside design temperature is  95 degrees fahrenheit.
  43.        The cooling  inside design temperature is  72 degrees fahrenheit.
  44.        The cooling  temperature  differential is  23 degrees fahrenheit.
  45.  
  46.    The heat gain for this building is      43,101 BTU's.
  47.  
  48.           This translates into       3.6 tons of cooling.
  49.  
  50.    The preferred cooling CFM is   1,293 CFM's for proper cooling.
  51.  
  52.                  For high humidity areas use     1,077 CFM's
  53.                  For normal humidity areas use   1,293 CFM's
  54.                  For low humidity areas use      1,508 CFM's
  55.  
  56.    Any cooling unit must be rated as close as possible to the heat gain
  57.    calculated in this study, but not less than that amount.
  58.  
  59. ****************************************************************************