; In the modem list below, MNP5 should be read as a synonym for "Error
; Correction with compression", and MNP4 as a synonym for "Error correction
; with compression disabled", i.e. these names are used even if the modem
; really uses V42/V42bis. This shorthand is used because anything else turns
; out to be incredibly long winded.
; The modem list only gives strings where they differ from INSTALL defaults.
; The default modem is 2400, no error correction, no init required, generic
; Hayes compatible. MNP in software.
------------------------
<Direct Connect / Null Modem>
------------------------
Acex 2400 V22bis+MNP5
Init = ATQ0V1E1X1S0=0&D2&C1\J0\Q3\V1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Amstrad SM4000/MC2400
Init = ATQ0V1E1X2S0=0F0&D2&C1|
------------------------
ATI Technologies, Inc. 2400etc
Init = ATB1E1L1M1N1TQ0V1W1X6&Q5&B1&C1&D2&K3&O1|
Speed = 9600
Disable EC = AT&Q0W0&B0&K0&O0|
Set MNP5 = AT&Q5W1&B1&K3&O1|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER|VOICE
Hardware MNP
------------------------
Best Data Products, Inc. 2400B/2400X
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Best Data Products, Inc. 9624F/FX FAX Modem
Init = ATB1E1Q0V1X4&C1&D2&M0|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Best Data Products, Inc. Smart One 1442F/1442FX FAX Modem
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 38400
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136\N3W1&K3|
Set MNP5 = AT&Q5S46=138\N3W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Best Data Products, Inc. Smart One 9624FQ FAX Modem
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Boca Research, Inc. BOCAFAX
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Boca Research, Inc. BOCAMODEM M1440EW/M1440IW
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 38400
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136\N3W1&K3|
Set MNP5 = AT&Q5S46=138\N3W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Boca Research, Inc. BOCAMODEM M2400E/M2400I
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 9600
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136W1&K3|
Set MNP5 = AT&Q5S46=138W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Boca Research, Inc. BOCAMODEM PM1440
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 38400
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136\N3W1&K3|
Set MNP5 = AT&Q5S46=138\N3W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Boca Research, Inc. Pocket Modem 96/24
Init = ATB1E1Q0V1X4&C1&D2&Q0|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
British Telecom PC424X
Init = AT&FS0=0&D3&W|
Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
Hangup =
Dial Delay = 2
------------------------
Dacom Datamate
Init = ATQ0V1E1X4S0=0&D2&C1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT\N3%C0|
Set MNP5 = AT\N3%C1|
Hardware MNP
------------------------
Dacom DSL2123 (DTI)
Init = |NP|~RESET|
Speed = 1200
Tone Dial = V23T|~TON|
Pulse Dial = V23T|~PLS|
Dial Suffix = |
Connect = &WAT
AutoAnswerOn = |NP|~AA|
AutoAnswerOff= |NP|~RESET|
------------------------
Dacom Quadplus
Init = ATQ0V1E1X4S0=0&D2&C1F1\J1&B0\Q2\T0B0\X2|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = ATS34=4\N3|
Set MNP5 = ATS34=5\N3|
Hardware MNP
------------------------
Dataflex Pocket Stradcom
Init = ATQ0V1E1X1S0=0|
------------------------
Dataflex Quadcom V22bis
Init = ATQ0V1E1X4S0=0&D2&C1\J0\Q3\V0S7=55|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Dataflex Quadcom 2400 + FAX
Init = ATQ0V1E1X4S0=0&D2&C1|
Speed = 4800
Disable EC = AT&Q0|
Set MNP4 = AT%C0&Q3|
Set MNP5 = AT%C1&Q3|
Hardware MNP
------------------------
Dataflex PC Rapier +
Init = AT&FS7=180S0=0|
Speed = 19200
Disable EC = AT\N0%C0|
Set MNP4 = AT\N3%C0|
Set MNP5 = AT\N3%C3|
Hardware MNP
------------------------
Datatronics Discovery 2400c
Init = ATX4E1Q0V1S0=0|
Speed = 2400
------------------------
Datatronics Discovery 2400 (MNP)
Init = ATX4E1Q0V1&C1&D2S0=0B0\J0\G0\Q3\V1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT\N3%C0|
Set MNP5 = AT\N3%C1|
Hardware MNP
------------------------
Datronics Discovery 9600
Init = ATQ0E1V1X1S7=255|
Speed = 19200
Disable EC = AT\Z|
Set MNP4 = AT%C0\Y|
Set MNP5 = AT%C1\Y|
Hardware MNP
------------------------
Dowty Quattro
Init = ATQ0V1E1X3S0=0F0&D2&C1&A0&I0|
Disable EC = AT&E0|
Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
Hangup =
------------------------
Dowty/Telebit Trailblazer
Init = ATQ0E1V1X3S7=60S110=1|
Disable EC = ATS95=0|
Set MNP4 = ATS95=2|
Set MNP5 = ATS95=2|
Hardware MNP
------------------------
Dynalink FAX Modem 2400
Init = ATQ0V1E1X4S0=0|
------------------------
E-Tech Research, Inc. BulletModem PC1414MX/DX
Init = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
Speed = 38400
Disable EC = AT$E0$F5$X0|
Set MNP4 = AT$E3$F4$C0$X2|
Set MNP5 = AT$E3$F4$C1$X2|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
E-Tech Research, Inc. UFOMATE P1414MX/DX
Init = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
Speed = 38400
Disable EC = AT$E0$F5$X0|
Set MNP4 = AT$E3$F4$C0$X2|
Set MNP5 = AT$E3$F4$C1$X2|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Gandalf ACCESS Series 3242
Init = AT&FX4E1Q0V1&C1&D2\J0\Q3\V0S0=0|
Speed = 19200
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
GVC Technologies, Inc. FAX Modem 9648
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
GVC Technologies, Inc. Super Modem 2400
Init = ATB1E1Q0V1X4&C1&D2&M0|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Hayes Generic
Init = ATQ0V1E1X1S0=0|
------------------------
Hayes V-Series 2400 Quadplus
Init = ATX4E1Q0V1&C1&D2S0=0&K1W2|
Disable EC = AT&Q0|
------------------------
Hayes V-Series ULTRA Smartmodem 9600
Init = ATX4E1Q0V1&C1&D2S0=0&K3W2|
Speed = 38400
Disable EC = AT&Q0|
Set MNP4 = ATS46=0&Q5|
Set MNP5 = ATS46=2&Q5|
Hardware MNP
------------------------
Hitec EC2400
Init = ATE1Q1V1S0=0X4F0&D2&C1&I1B0&S0\Q2|
Speed = 4800
Disable EC = AT\N1|
Set MNP4 = AT%C0\N2|
Set MNP5 = AT%C1\N2|
Hardware MNP
------------------------
Hyundai HMD-2404M
Init = ATE1Q1V1S0=0X4\J0\Q3&D2&C1B0|
Speed = 9600
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Intel 2400/2400e V.42bis Modem
Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
Speed = 9600
Disable EC = AT\N