home *** CD-ROM | disk | FTP | other *** search
/ PsL Monthly 1994 February / psl_9403.zip / psl_9403 / DOS / COMMUNIC / ODY20_TR.ZIP / ODY200SH.LZH / ODYSSEY.MDM < prev    next >
Text File  |  1993-11-29  |  19KB  |  641 lines

  1.  
  2. ; In the modem list below, MNP5 should be read as a synonym for "Error
  3. ; Correction with compression", and MNP4 as a synonym for "Error correction
  4. ; with compression disabled", i.e. these names are used even if the modem
  5. ; really uses V42/V42bis. This shorthand is used because anything else turns
  6. ; out to be incredibly long winded.
  7.  
  8. ; The modem list only gives strings where they differ from INSTALL defaults.
  9. ; The default modem is 2400, no error correction, no init required, generic
  10. ; Hayes compatible. MNP in software.
  11.  
  12. ------------------------
  13. <Direct Connect / Null Modem>
  14. ------------------------
  15. Acex 2400 V22bis+MNP5
  16. Init         = ATQ0V1E1X1S0=0&D2&C1\J0\Q3\V1|
  17. Speed        = 4800
  18. Disable EC   = AT\N0|
  19. Set MNP4     = AT%C0\N3|
  20. Set MNP5     = AT%C1\N3|
  21. Hardware MNP
  22. ------------------------
  23. Amstrad SM4000/MC2400
  24. Init         = ATQ0V1E1X2S0=0F0&D2&C1|
  25. ------------------------
  26. ATI Technologies, Inc. 2400etc
  27. Init         = ATB1E1L1M1N1TQ0V1W1X6&Q5&B1&C1&D2&K3&O1|
  28. Speed        = 9600
  29. Disable EC   = AT&Q0W0&B0&K0&O0|
  30. Set MNP5     = AT&Q5W1&B1&K3&O1|
  31. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER|VOICE
  32. Hardware MNP
  33. ------------------------
  34. Best Data Products, Inc. 2400B/2400X
  35. Init         = ATB1E1Q0V1X4&C1&D2|
  36. Speed        = 2400
  37. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  38. Software MNP
  39. ------------------------
  40. Best Data Products, Inc. 9624F/FX FAX Modem
  41. Init         = ATB1E1Q0V1X4&C1&D2&M0|
  42. Speed        = 2400
  43. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  44. Software MNP
  45. ------------------------
  46. Best Data Products, Inc. Smart One 1442F/1442FX FAX Modem
  47. Init         = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
  48. Speed        = 38400
  49. Disable EC   = AT&Q6W0&K0|
  50. Set MNP4     = AT&Q5S46=136\N3W1&K3|
  51. Set MNP5     = AT&Q5S46=138\N3W1&K3|
  52. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  53. Hardware MNP
  54. ------------------------
  55. Best Data Products, Inc. Smart One 9624FQ FAX Modem
  56. Init         = ATB1E1Q0V1X4&C1&D2|
  57. Speed        = 2400  
  58. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  59. Software MNP
  60. ------------------------
  61. Boca Research, Inc. BOCAFAX
  62. Init         = ATB1E1Q0V1X4&C1&D2|
  63. Speed        = 2400
  64. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  65. Software MNP
  66. ------------------------
  67. Boca Research, Inc. BOCAMODEM M1440EW/M1440IW
  68. Init         = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
  69. Speed        = 38400
  70. Disable EC   = AT&Q6W0&K0|
  71. Set MNP4     = AT&Q5S46=136\N3W1&K3|
  72. Set MNP5     = AT&Q5S46=138\N3W1&K3|
  73. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  74. Hardware MNP
  75. ------------------------
  76. Boca Research, Inc. BOCAMODEM M2400E/M2400I
  77. Init         = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
  78. Speed        = 9600
  79. Disable EC   = AT&Q6W0&K0|
  80. Set MNP4     = AT&Q5S46=136W1&K3|
  81. Set MNP5     = AT&Q5S46=138W1&K3|
  82. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  83. Hardware MNP
  84. ------------------------
  85. Boca Research, Inc. BOCAMODEM PM1440
  86. Init         = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
  87. Speed        = 38400
  88. Disable EC   = AT&Q6W0&K0|
  89. Set MNP4     = AT&Q5S46=136\N3W1&K3|
  90. Set MNP5     = AT&Q5S46=138\N3W1&K3|
  91. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  92. Hardware MNP
  93. ------------------------
  94. Boca Research, Inc. Pocket Modem 96/24
  95. Init         = ATB1E1Q0V1X4&C1&D2&Q0|
  96. Speed        = 2400
  97. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  98. Software MNP
  99. ------------------------
  100. British Telecom PC424X
  101. Init         = AT&FS0=0&D3&W|
  102. Failure      = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
  103. Hangup       =
  104. Dial Delay   = 2
  105. ------------------------
  106. Dacom Datamate
  107. Init         = ATQ0V1E1X4S0=0&D2&C1|
  108. Speed        = 4800
  109. Disable EC   = AT\N0|
  110. Set MNP4     = AT\N3%C0|
  111. Set MNP5     = AT\N3%C1|
  112. Hardware MNP
  113. ------------------------
  114. Dacom DSL2123 (DTI)
  115. Init         = |NP|~RESET|
  116. Speed        = 1200
  117. Tone Dial    = V23T|~TON|
  118. Pulse Dial   = V23T|~PLS|
  119. Dial Suffix  = |
  120. Connect      = &WAT
  121. AutoAnswerOn = |NP|~AA|
  122. AutoAnswerOff= |NP|~RESET|
  123. ------------------------
  124. Dacom Quadplus
  125. Init         = ATQ0V1E1X4S0=0&D2&C1F1\J1&B0\Q2\T0B0\X2|
  126. Speed        = 4800
  127. Disable EC   = AT\N0|
  128. Set MNP4     = ATS34=4\N3|
  129. Set MNP5     = ATS34=5\N3|
  130. Hardware MNP
  131. ------------------------
  132. Dataflex Pocket Stradcom
  133. Init         = ATQ0V1E1X1S0=0|
  134. ------------------------
  135. Dataflex Quadcom V22bis
  136. Init         = ATQ0V1E1X4S0=0&D2&C1\J0\Q3\V0S7=55|
  137. Speed        = 4800
  138. Disable EC   = AT\N0|
  139. Set MNP4     = AT%C0\N3|
  140. Set MNP5     = AT%C1\N3|
  141. Hardware MNP
  142. ------------------------
  143. Dataflex Quadcom 2400 + FAX
  144. Init         = ATQ0V1E1X4S0=0&D2&C1|
  145. Speed        = 4800
  146. Disable EC   = AT&Q0|
  147. Set MNP4     = AT%C0&Q3|
  148. Set MNP5     = AT%C1&Q3|
  149. Hardware MNP
  150. ------------------------
  151. Dataflex PC Rapier +
  152. Init         = AT&FS7=180S0=0|
  153. Speed        = 19200
  154. Disable EC   = AT\N0%C0|
  155. Set MNP4     = AT\N3%C0|
  156. Set MNP5     = AT\N3%C3|
  157. Hardware MNP
  158. ------------------------
  159. Datatronics Discovery 2400c
  160. Init         = ATX4E1Q0V1S0=0|
  161. Speed        = 2400
  162. ------------------------
  163. Datatronics Discovery 2400 (MNP)
  164. Init         = ATX4E1Q0V1&C1&D2S0=0B0\J0\G0\Q3\V1|
  165. Speed        = 4800
  166. Disable EC   = AT\N0|
  167. Set MNP4     = AT\N3%C0|
  168. Set MNP5     = AT\N3%C1|
  169. Hardware MNP
  170. ------------------------
  171. Datronics Discovery 9600
  172. Init         = ATQ0E1V1X1S7=255|
  173. Speed        = 19200
  174. Disable EC   = AT\Z|
  175. Set MNP4     = AT%C0\Y|
  176. Set MNP5     = AT%C1\Y|
  177. Hardware MNP
  178. ------------------------
  179. Dowty Quattro
  180. Init         = ATQ0V1E1X3S0=0F0&D2&C1&A0&I0|
  181. Disable EC   = AT&E0|
  182. Failure      = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
  183. Hangup       =
  184. ------------------------
  185. Dowty/Telebit Trailblazer
  186. Init         = ATQ0E1V1X3S7=60S110=1|
  187. Disable EC   = ATS95=0|
  188. Set MNP4     = ATS95=2|
  189. Set MNP5     = ATS95=2|
  190. Hardware MNP
  191. ------------------------
  192. Dynalink FAX Modem 2400
  193. Init         = ATQ0V1E1X4S0=0|
  194. ------------------------
  195. E-Tech Research, Inc. BulletModem PC1414MX/DX
  196. Init         = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
  197. Speed        = 38400
  198. Disable EC   = AT$E0$F5$X0|
  199. Set MNP4     = AT$E3$F4$C0$X2|
  200. Set MNP5     = AT$E3$F4$C1$X2|
  201. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  202. Hardware MNP
  203. ------------------------
  204. E-Tech Research, Inc. UFOMATE P1414MX/DX
  205. Init         = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
  206. Speed        = 38400
  207. Disable EC   = AT$E0$F5$X0|
  208. Set MNP4     = AT$E3$F4$C0$X2|
  209. Set MNP5     = AT$E3$F4$C1$X2|
  210. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  211. Hardware MNP
  212. ------------------------
  213. Gandalf ACCESS Series 3242
  214. Init         = AT&FX4E1Q0V1&C1&D2\J0\Q3\V0S0=0|
  215. Speed        = 19200
  216. Disable EC   = AT\N0|
  217. Set MNP4     = AT%C0\N3|
  218. Set MNP5     = AT%C1\N3|
  219. Hardware MNP
  220. ------------------------
  221. GVC Technologies, Inc. FAX Modem 9648
  222. Init         = ATB1E1Q0V1X4&C1&D2|
  223. Speed        = 2400
  224. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  225. Software MNP
  226. ------------------------
  227. GVC Technologies, Inc. Super Modem 2400
  228. Init         = ATB1E1Q0V1X4&C1&D2&M0|
  229. Speed        = 2400
  230. Failure      = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
  231. Software MNP
  232. ------------------------
  233. Hayes Generic
  234. Init         = ATQ0V1E1X1S0=0|
  235. ------------------------
  236. Hayes V-Series 2400 Quadplus
  237. Init         = ATX4E1Q0V1&C1&D2S0=0&K1W2|
  238. Disable EC   = AT&Q0|
  239. ------------------------
  240. Hayes V-Series ULTRA Smartmodem 9600
  241. Init         = ATX4E1Q0V1&C1&D2S0=0&K3W2|
  242. Speed        = 38400
  243. Disable EC   = AT&Q0|
  244. Set MNP4     = ATS46=0&Q5|
  245. Set MNP5     = ATS46=2&Q5|
  246. Hardware MNP
  247. ------------------------
  248. Hitec EC2400
  249. Init         = ATE1Q1V1S0=0X4F0&D2&C1&I1B0&S0\Q2|
  250. Speed        = 4800
  251. Disable EC   = AT\N1|
  252. Set MNP4     = AT%C0\N2|
  253. Set MNP5     = AT%C1\N2|
  254. Hardware MNP
  255. ------------------------
  256. Hyundai HMD-2404M
  257. Init         = ATE1Q1V1S0=0X4\J0\Q3&D2&C1B0|
  258. Speed        = 9600
  259. Disable EC   = AT\N0|
  260. Set MNP4     = AT%C0\N3|
  261. Set MNP5     = AT%C1\N3|
  262. Hardware MNP
  263. ------------------------
  264. Intel 2400/2400e V.42bis Modem
  265. Init         = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
  266. Speed        = 9600
  267. Disable EC   = AT\N