  2.        ╔═════════════════════════════════════════════════╗ 
  3.        ║                 READ ME FIRST !!                ║ 
  4.        ╚═════════════════════════════════════════════════╝ 
  5.  
  6.   Version 5.12 - 4/30/93 
  7.   
  8.   Thank you for using DiagSoft's QAPlus/FE! 
  9.  
  10.   We feel these diagnostics are among the finest, most complete 
  11.   and compatible in the PC marketplace.  If you ever have any 
  12.   questions, comments or suggestions about DiagSoft products, 
  13.   please call us at 408-438-8247, or FAX us at 408-438-7113.  You 
  14.   may also submit Software Problem Reports, by mail or FAX, 
  15.   following the outline of the SUPPORT.TXT file included on your 
  16.   program diskette. 
  17.  
  18.                      * VERSION INFORMATION * 
  19.  
  20.   This product release and these notes pertain to QAPlus/FE 
  21.   version 5.12.  It is helpful for you to know and have available 
  22.   the serial number, version number and the toolkit number (or 
  23.   QAPLUSFE.EXE file date) when calling for technical support. 
  24.  
  25.   This file contains the following: 
  26.  
  27.    1.  New Program Changes and Enhancements
  28.    2.  Performance Notes 
  29.    3.  Documentation Changes that have not been incorporated into 
  30.        the printed documentation. 
  31.     
  32.   _______________________________________________________________ 
  33.  
  34.    PROGRAM CHANGES AND ENHANCEMENTS 
  35.  
  36. Ver 5.10 - 10/27/92   
  37.       
  38.   QAPlus/FE, (v5.10), contains the following enhancements: 
  39.  
  40.    1.  The following hardware is now identified: 
  41.           
  42.        - Intel 80386SL, 80486SL and 80486SX CPUs 
  43.    
  44.        - Cyrix C486SLC and C486DLC CPUs 
  45.    
  46.        - CD ROM devices 
  47.    
  48.        - UltraStor 14F and 24F SCSI controllers 
  49.    
  50.        - 2.88Mb Floppy drives 
  51.    
  52.        - Up to 1Mb of Video RAM is recognized on video cards by 
  53.          Paradise and those using the Tseng video chips, and up 
  54.          to 4Mb of Video RAM is recognized on certain ATI video 
  55.          cards. 
  56.  
  57.    2.  The following changes have been made to QAPlus/FE testing: 
  58.    
  59.        - Logging of test results and configuration information to 
  60.          dBase format files 
  61.    
  62.        - Floppy Test now supports 2.88Mb floppy drives 
  63.    
  64.        - New CD ROM test 
  65.    
  66.        - Memory Tests are faster and include expanded memory 
  67.          testing under EMM386, and 486 internal cache memory 
  68.          testing 
  69.  
  70.        - Hard Drive Tests include enhanced support for Quantum 
  71.          hard drives 
  72.  
  73.    3.  An improved System Information section has been moved to 
  74.        the main menu for quicker access.  It includes the 
  75.        following enhancements: 
  76.  
  77.        - New First Megabyte Memory Map showing DOS (640K) and 
  78.          Upper Memory Blocks (640K-1024K), including the 
  79.          addresses for Video RAM, ROM chips, EMS page frames, 
  80.          Free and Used High Memory.  It includes the ability 
  81.          to obtain more detailed information about these memory 
  82.          areas including ROM data and which DOS programs are 
  83.          loaded in upper memory blocks. 
  84.  
  85.        - The ability to print System Information to a file or 
  86.          printer. 
  87.  
  88.    4.  Enhanced System Utilities now include: 
  89.    
  90.        - A new File Editor for editing system configuration 
  91.          files such as AUTOEXEC.BAT and CONFIG.SYS 
  92.  
  93.        - A new QAMatch utility for comparing different versions 
  94.          of system configuration files 
  95.    
  96.        - A new QAPlus/Report utility for viewing and printing 
  97.          configuration and test results from dBase files 
  98.  
  99.        - An enhanced RAM Chip Locator that supports SIMMs and 
  100.          SIPs 
  101.  
  102.        - QASCSI now supports UltraStor 14F & 24F controllers 
  103.     
  104.    5.  Bundled Reachout(TM) Host remote control software 
  105.  
  106.    __________________________________________________________ 
  107.  
  108.    QAPlus/FE, (v5.12), contains the following enhancements: 
  109.  
  110.    1.  The SCSI Test Group is now run directly from the Module 
  111.        Test Menu, rather than loading a separate executable file.  
  112.        This speeds up testing operations, and permits test data 
  113.        from the SCSI tests to go to the Test Log.  The SCSI Test 
  114.        Group now also supports multiple LUNs, and you may also 
  115.        choose starting and ending blocks as well as the random 
  116.        seek quantity. 
  117.   
  118.    2.  By pressing the [F2] function key from within the Module 
  119.        Tests Menu or any of the Test Group test screens you can 
  120.        examine the Log Message Queue.  This shows you the test 
  121.        results to date, whether or not you have set up a 
  122.        permanent Test Log. 
  123.  
  124.    3.  You can now load your own test programs from the Module 
  125.        Tests Menu via a new User Diags option.  These tests may 
  126.        be scripted and the results can be recorded in the test 
  127.        log along with the other QAPlus/FE tests if the tests 
  128.        output standard DOS error codes. 
  129.  
  130.    4.  Identification of Microsoft's DoubleSpace<TM> Drives - 
  131.        Drives that have been compressed with the DoubleSpace 
  132.        utility in MS-DOS 6.0 are identified in the Hardware 
  133.        configuration screen.  You may actually have a greater 
  134.        capacity on the DoubleSpace drive, depending on the types 
  135.        of files that are stored. 
  136.   
  137.    5.  An enhanced Hardware Configuration screen now indicates if 
  138.        EMM is active, and it IDs the latest components including 
  139.        the new Intel Pentium CPU, several new sound cards, and 
  140.        the Roland MPU-401 MIDI interface. 
  141.  
  142.    6.  Additional computer systems are now identified during the 
  143.        Hardware Configuration check. 
  144.  
  145.    7.  An enhanced memory test that supports the Headland 
  146.        external cache controller.
  147.  
  148.    8.  An enhanced video test that supports the S3 video 
  149.        accelerator. 
  150.  
  151.    9.  An enhanced Memory Map report that IDs QEMM High RAM. 
  152.        
  153.   10.  An enhanced IRQ/DMA report that IDs interrupts generated 
  154.        by several SCSI host adapters from Adaptec, Future Domain 
  155.        and Seagate; the Sound Blaster, AdLib Sound Board and Aria 
  156.        Sound Board; and the Roland MPU-401 MIDI interface. 
  157.  
  158.   11.  When "Hardware Config." is chosen from the System 
  159.        Information menu, a new menu is now presented to permit 
  160.        you to toggle devices on or off for the Hardware 
  161.        Configuration check.  Also, the Machine Type item (if 
  162.        determined by QAPlus/FE) will appear on the same line, to 
  163.        the right of the Processor Type. 
  164.   
  165.   12.  When "IRQ/DMA" is chosen from the System Information menu, 
  166.        there are now two option menus presented.  The first menu 
  167.        allows to toggle devices on or off for IRQ checking.  The 
  168.        second menu allows you to toggle devices on or off for DMA 
  169.        checking in the same manner.              
  170.        
  171.   _____________________________________________________________ 
  172.  
  173.   PERFORMANCE NOTES 
  174.   
  175.    1.  If you run the full QAPlus/FE program with all its tests 
  176.        and utilities available, there is a program Base RAM 
  177.        requirement of approximately 500K of free memory -- 
  178.        depending on the configuration of your computer system.  
  179.        If your system does not have this much available free RAM, 
  180.        there are a number of options which will facilitate 
  181.        reducing the memory requirements of the program.   
  182.  
  183.        For example, if you plan to do diagnostic testing only, 
  184.        and will not need direct access to the utility programs 
  185.        from within QAPlus/FE, you would load the program using 
  186.        the QAPLUSFE.EXE executable instead of the normal QAFE.EXE 
  187.        program loader.  In this instance you would still be able 
  188.        to access each of these utilities individually from the 
  189.        DOS prompt, after you have unloaded QAPlus/FE. 
  190.  
  191.        To make additional memory available within your system, 
  192.        you may wish to temporarily unload net drivers or TSRs 
  193.        (by typing "rem " in front of the appropriate device 
  194.        drivers in your CONFIG.SYS or AUTOEXEC.BAT file).  You 
  195.        might also wish to use the DOS=HIGH,UMB option in your 
  196.        CONFIG.SYS file, and use the LOADHIGH and DEVICEHIGH 
  197.        options to load device drivers into high memory.  With DOS 
  198.        6.0 you can use the MEMMAKER option to free up enough Base 
  199.        RAM to run the full QAPlus/FE with all of its utility 
  200.        programs accessible from within the program. 
  201.  
  202.        If there are specific tests which you do not plan to run, 
  203.        you can lessen the program Base RAM requirement by using 
  204.        the "-O" option discussed as item number "2." in the 
  205.        DOCUMENTATION CHANGES section which follows later in this 
  206.        file.  Using this option will omit specified test groups 
  207.        from testing.  You may omit several test groups with this 
  208.        procedure to lessen the Base RAM requirement, or to speed 
  209.        the program loading time. 
  210.   
  211.    2.  If you are booting QAPlus/FE from a floppy diskette, the 
  212.        DMA Transfer Test may appear to hang at the page register 
  213.        test.  Actually, it simply takes a long time under these 
  214.        circumstances.  You should either allow the extra time 
  215.        for this test (the time will vary according to your 
  216.        system), or disable this test 
  217.  
  218.    3.  If you have a printer connected to the parallel port, the 
  219.        loopback test will fail.  Conversely, if you have a 
  220.        loopback plug connected to the parallel port, the printer 
  221.        test will fail. 
  222.  
  223.    4.  To test the ATI video memory beyond 512KB you will have 
  224.        to reconfigure your board using the manufacturer supplied 
  225.        configuration utility.  Note that some of that memory is 
  226.        generally used by the video coprocessor and you will have 
  227.        to temporarily reconfigure this to video memory to test 
  228.        it. 
  229.   
  230.    5.  If you wish to run the external or internal cache test 
  231.        LUN's in the Memory Test Group you will have to 
  232.        temporarily disable any resident expanded memory manager 
  233.        software you may have loaded, then reboot your computer, 
  234.        and reload QAPlus/FE.  For example, if EMM386.SYS is 
  235.        loaded you will not be able to run the cache tests. 
  236.  
  237.    6.  For the floppy disk test to function properly, you must 
  238.        insert a diskette of the maximum capacity supported by the 
  239.        drive you wish to test.  For example, if you wish to test 
  240.        a 1.44 Mb floppy drive you must insert a formatted 1.44 Mb 
  241.        floppy diskette -- NOT a 720 Kb floppy diskette. 
  242.  
  243.    7.  Whether you have booted your computer from a floppy 
  244.        diskette, or from your hard disk: if you run QAPlus/FE 
  245.        from a floppy diskette you will not be able to run the 
  246.        Utilities from the QAPlus/FE Utility menu.  If you use the 
  247.        DOS Shell option on the Utility menu you should be able to 
  248.        call up the executable utilities individually, as long as 
  249.        you have enough available free memory.  
  250.  
  251.    8.  The CD-ROM test will show errors if the CD-ROM disk 
  252.        doesn't have data in all sectors.  To prevent this, you 
  253.        may wish to limit the test to those sectors with data.  
  254.        This is immediately obvious when running the Butterfly 
  255.        test, which immediately jumps to the extreme sectors on 
  256.        the CD-ROM disk. 
  257.  
  258.    9.  When creating a USERDIAG.CFG file as discussed on page 32
  259.        of the User Guide, you need to press [Enter] at the end of 
  260.        each line of text as you type in the text it to force a 
  261.        CR LF at the end of each line.  This is necessary for 
  262.        QAPlus/FE to correctly find and run User Diagnostics.  An 
  263.        example USERDIAG.CFG file has been included with QAPlus/FE 
  264.        to assist you in creating your own USERDIAG.CFG file. 
  265.  
  266.   10.  If QAPlus/FE detects constant DMA activity during testing, 
  267.        the IC Data Paths Test will skip the test for the DMA 
  268.        channel with the constant activity. 
  269.  
  270.   11.  If you plan to run Hard Disk tests and to do test logging, 
  271.        do the test logging on a drive other than the drive(s) to 
  272.        be tested.  If you log to a drive that is to be tested, 
  273.        the logging will be disabled for the remainder of the test 
  274.        cycle. 
  275.  
  276.   _______________________________________________________________ 
  277.  
  278.   DOCUMENTATION CHANGES 
  279.    
  280.   The following information was not available when the QAPlus/FE 
  281.   documentation was published: 
  282.  
  283.    1.  Before the last numbered item in the Installing QAPlus/FE
  284.        a new item 5. to be inserted is: 
  285.  
  286.        5.  After all of the files have been installed you will 
  287.            be prompted to fill out registration information. 
  288.            Fill in the fields with the appropriate information
  289.            for "Name", "Company", and "Serial Number", then
  290.            press [F10] when you have completed filling out the
  291.            form.  (Renumber old number 5 to number 6).
  292.  
  293.    2.  New command line option:   -Ogroup 
  294.        This option omits a test group from testing. 
  295.             group = MBD/MEM/VID/HDU/FDU/KBD/COM/LPT/PDV/SCU 
  296.  
  297.        Example:  QAFE -OMEM    would omit memory testing. 
  298.  
  299.    3.  The Virus Scan section documented at the end of the 
  300.        Utilities chapter no longer applies. 
  301.   
  302.    4.  Near the end of the QAPlus/FE User Guide, "In Depth 
  303.        Testing" chapter it is noted that SCSI devices can not be 
  304.        selected as individual LUN's.  That statement no longer 
  305.        applies, and SCSI testing is now done in the same manner 
  306.        as the other QAPlus/FE test groups. 
  307.  
  308.    5.  In the Reference Manual, the following should be 
  309.        included: 
  310.     
  311.        SCSI Hard Disk Test Group:  SCU -- 1700 
  312.  
  313.        This test module will support the following SCSI Host 
  314.        Adapters: 
  315.      
  316.          DPT EISA SCSI Host Adapter 
  317.          Adaptec SCSI Host Adapter 
  318.          WD-7000 SCSI Host Adapter 
  319.          Adaptec EISA SCSI Host Adapter (STANDARD MODE) 
  320.          Adaptec EISA SCSI Host Adapter (ENHANCED MODE) 
  321.          Adaptec SCSI Host Adapter (ASPI) 
  322.          UltraStor 24F EISA SCSI Host Adapter 
  323.          UltraStor 14F ISA SCSI Host Adapter 
  324.          Mylex DCE376 EISA SCSI Host Adapter 
  325.   
  326.        This test module contains the following tests: 
  327.         
  328.          203-Device Diagnostic Test 
  329.          204-Device Buffer Test 
  330.          205-Random Seek Verify 
  331.          206-Funnel Seek Verify 
  332.          207-Seq Seek Verify 
  333.          208-Surface Write/Read 
  334.          209-Seq Write/Read 
  335.          210-Seq Write/Random Read 
  336.          211-Streaming Write/Read 
  337.          212-Erase Tape Test 
  338.  
  339.        Note: Not all tests are available, as not all apply to all 
  340.              devices.  For example, tests 211 & 212 are 
  341.              unavailable when testing a SCSI hard disk. 
  342.  
  343.        Supported test command / parameters: 
  344.  
  345.          DO TEST < test number >  - performs the diagnostic test 
  346.          DOGROUP                  - performs all applical tests 
  347.                                     for selected device (LUN) 
  348.          LUN <unit number>        - selects the specified unit 
  349.                                     number for testing 
  350.          CONFIG                   - displays /logs configuration 
  351.                                     information 
  352.          STARTBLK <start block>   - specifies the starting block  
  353.                                     number testing 
  354.          ENDBLK <end block>       - specifies the ending block 
  355.                                     for testing 
  356.          RNDBLKCNT <random count> - specifies the number of block 
  357.                                     for random type tests 
  358.  
  359.    6.  At the end of the QAPlus/FE User Guide, In Depth Testing 
  360.        chapter, the following new section should be added:  
  361.  
  362.        Test Group Specifications 
  363.   
  364.          In the upper right hand portion of the testing screen 
  365.          (or just the upper portion if you have switched to an 
  366.          individual test group screen), are the specifications 
  367.          for the related test group. 
  368.     
  369.          Note:  In the Hard Disk Test Group specification area, 
  370.                 if you are using a DoubleSpaced<TM> or 
  371.                 Stacked<TM> drive, the indicated size will be the 
  372.                 DoubleSpaced size of the logical drive.   
  373.                 
  374.    7.  At the bottom of the first page of the System Information 
  375.        chapter in the QAPlus/FE User Guide, the following note 
  376.        should appear: 
  377.  
  378.          Note:  In the Hardware Configuration Report, if you are 
  379.                 using a DoubleSpaced<TM> or Stacked<TM> drive, 
  380.                 the indicated size will be the DoubleSpaced 
  381.                 size of the drive determined from CMOS BIOS.  
  382.                 You may actually have a greater available 
  383.                 capacity on the DoubleSpace drive, depending upon 
  384.                 the types of files that are stored.  
  385.     
  386.    8.  One of the tests in the System Board Test Group is 
  387.        indicated in the test group list as the "Refresh 
  388.        Interrupt" test.  This is listed in the QAPlus/FE 
  389.        Reference Manual and is actually the "Refresh Interval" 
  390.        test.  This test determines if there is a change or 
  391.        instability in the RAM Refresh function of the system 
  392.        under test. 
  393.   
  394.        The test is done by comparing the Refresh Interval as 
  395.        determined during the "analysis" phase of program start-
  396.        up, against a retest of the Refresh Interval within the 
  397.        System Board test suite. 
  398.   
  399.        The "Ref Int" parameter indicated within the System Board 
  400.        Test Group is a number representing twice the Refresh 
  401.        Interval.  In most cases this value is 30 and represents 
  402.        15 microseconds.  If this test fails, contact the BIOS or 
  403.        system board manufacturer to determine of the Refresh 
  404.        Interval is changed for any reason.  If so, the failure is 
  405.        "normal" for your system. 
  406.  
  407.    9.  The following note is to be placed at the bottom of the 
  408.        first page of Chapter 2 of the Power Meter User Guide: 
  409.  
  410.   Note:If you are using Power Meter as a utility included with 
  411.        QAPlus/FE, Power Meter was installed automatically during 
  412.        the QAPlus/FE installation procedure, and you may skip the 
  413.        next five pages of the User Guide to page 11 and the 
  414.        Testing Standards section. 
  415.  
  416.    10. In chapter 1 of the User Guide, in the "IRQ checking and
  417.        Port Assignments" section, the following note should
  418.        be placed after the lists of the accepted or default
  419.        assignments for typical devices in PC systems:
  420.  
  421.   Note:With some computers you may have to install a parallel 
  422.        loopback plug on your active parallel port connector to 
  423.        obtain an accurate IRQ for the parallel port during the 
  424.        IRQ report.
  425.  
  426.        The same note should also be placed as Note (4.) in the
  427.        IRQ/DMA secton of the System Information chapter in the