- RADIO-FREQUENCY RADIATION CALCULATION PROGRAM*
-
- (*RFCALCS)
-
-
- THIS PROGRAM IS BASED UPON AIR FORCE OCCUPATIONAL SAFETY AND
- HEALTH (AFOSH) STANDARD 161-9, DATED 12 OCTOBER 1984.
-
- THIS PROGRAM IS USED TO HELP TO DETERMINE IF A PARTICULAR RF
- (RADIO-FREQUENCY) EMITTER IS HAZARDOUS, POTENTIALLY HAZARDOUS, OR
- NON-HAZARDOUS TO PERSONNEL EXPOSED TO ITS ENERGY.
-
-
- CODES FOR PROGRAM:
-
- 1) ANTENNA CODES:
-
- BL -- BLADE
- CR -- CIRCULAR REFLECTOR
- DC -- DISCONE
- DI -- DISCAGE
- DL -- DUMMY LOAD
- DP -- DIPOLE OR DIPOLE ARRAY
- ER -- ELLIPTICAL REFLECTOR
- HE -- HELIX
- HL -- HORIZONTAL LOG PERIODIC
- HO -- HORN
- LE -- LENS
- LO -- LOOP
- MO -- MONOPOLE OE COLINEAR ARRAY
- OD -- OTHER, DIRECTIONAL
- OO -- OTHER, OMNIDIRECTIONAL
- PA -- PHASED ARRAY
- RH -- RHOMBIC
- RR -- RECTANGULAR REFLECTOR
- SL -- SLOT / SLOT ARRAY
- ST -- STUB
- VL -- VERTICAL LOG PERIODIC
- WH -- WHIP
-
- 2. SCANNING CODES:
-
- E -- SECTOR SCAN (ELECTRONIC)
- F -- FIXED
- R -- ROTATING (360 DEGREES)
- S -- SECTOR SCAN (MECHANICAL)
- T -- TRACKER
-
- 3. HAZARD CODES:
-
- CH -- HAZARD LEVELS POSSIBLE, BUT OLNY IN AREAS THAT REQUIRE
- CLIMBING.
- DL -- TRANSMITTER DUMMY LOADED.
- GH -- GROUND-LEVEL HAZARDOUS EXPOSURES POSSIBLE.
- IH -- HAZARDOUS LEVELS POSSIBLE, BUT IN NORMALLY INACCESSABLE
- AREAS.
- MD -- MEDICAL DEVICE; NO LEVELS GENERATED IN EXCESS OF PEL.
- MH -- MEDICAL DEVICE; LEVELS GENERATED IN EXCESS OF PEL.
- HN -- NO LEVELS GENERATED IN EXCESS OF PEL
- SH -- TIME IS TOO SHORT OR INHERENT EQUIPMENT LIMITATIONS MAKE
- OVEREXPOSURE UNLIKELY OR IMPOSSIBLE.
-
- 4. SYSTEM CONTROL CODES:
-
- AS -- AUDIBLE SIGNAL
- BA -- ROPE OR CHAIN BARRIER
- CO -- CONSTANT OBSERVATION WHEN TRANSMITTING
- FE -- FENCE
- FL -- FLASHING LIGHTS
- NR -- NO CONTROLS REQUIRED
- OM -- OTHER
- SC -- SPECIAL COORDINATION WHEN TRANSMITTING
- SO -- STANDARD OPERATING PROCEDURE IN EFFECT
- WS -- WARNING SIGNS
-
- TABLE 1 -- MAXIMUM PERMISSIBLE EXPOSURE LIMITS (PEL'S) FOR HUMAN
- EXPOSURE TO RADIO-FREQUENCY RADIATION. AVERAGED OVER ANG 6 MINUTE
- PERIOD.**
-
- ________________________________________________________________
- FREQ PEL FOR AVG. PEL FOR SMALL
- FROM TO SIZE ADULT SIZE HUMAN
- MHZ MHZ (mw/sq.cm.) (mw/sq.cm.)
- ________________________________________________________________
- .01 3 100 100
- 3 30 900/f2 900/f2
- 30 100 1 1
- 100 300 f/100 1
- 300 1000 f/100 f/300
- 1000 1500 10 f/300
- 1500 300000 10 5
-
- ** -- OBTAINED FROM AFOSH STANDARD 161-9 "EXPOSURE TO
- RADIOFREQUENCY RADIATION", DATED 12 OCTOBER 1984.
-
- NOTE: PEL IS THE SAME AS TWA.