  1. .MCD 25000 0
  2. .CMD SURFACEFORMAT rot=10 tilt=35 vScale=20 size=15,30 hide=n
  3. .CMD SKETCHFORMAT mag=1.000000,1.000000 center=0.500000,0.500000 size=15,30 box=y
  4. .CMD PLOTFORMAT logs=0,0 subdivs=1,1 size=5,15 type=l
  5. .CMD FORMAT  rd=d ct=10 im=i et=3 zt=15 pr=3 mass length time charge
  6. .CMD SET ORIGIN 0
  7. .CMD SET TOL 0.001000000000000
  8. .CMD MARGIN 0
  9. .CMD LINELENGTH 78
  10. .CMD SET PRNCOLWIDTH 8
  11. .CMD SET PRNPRECISION 4
  12. .TXT 1 0 34 81 
  13. a34,80,78,1501
  14. This file contains up-to-date information on the latest release of MathCAD's 
  15. Mechanical Engineering II Applications Pack, including additions and 
  16. corrections to the documentation.
  17. 
  18. 
  19. SYSTEM REQUIREMENTS
  20. To use the documents in this Applications Pack you must have MathCAD Version 
  21. 2.0 or later.  You should have 640K of RAM, and a coprocessor is recommended.
  22. 
  23. USING THE APPLICATIONS
  24. To load an application file from the Applications Diskette, first load MathCAD 
  25. from your MathCAD System Diskette or hard disk.  Then insert the Applications 
  26. Diskette in drive A and press [F5].  At the File to load prompt, type A: 
  27. followed by the name of the file you are loading.  
  28. 
  29. HELP
  30. If you encounter difficulty in loading or running the applications on this 
  31. diskette, call Technical Support at MathSoft.
  32. 
  33. DOCUMENTATION
  34. 
  35. 1. On page 30 in the documentation for Pressure Drop through Pipes, the 
  36. equations in the third screen shot should be entered BEFORE the equations in 
  37. the second screen shot.
  38. 
  39. 2. In the application Liquid Flow through Orifices, note that if you enter a 
  40. temperature outside the range for which the correlations for the chosen pipe 
  41. material are valid, the correction factor Fa will receive a zero value and 
  42. beta and d will not be calculated.
  43. 
  44. 3. In the application Centrifugal Pump Design, the value for the estimated 
  45. shaft power Pow shown on page 70 should be 443.7 hp.  The first factor in the 
  46. equation for Pow shown on page 74 should be 100/Ep rather than 1/Ep.