home *** CD-ROM | disk | FTP | other *** search
/ Installer 5.00 - Please Dont Remove it From My Bag / 060126_0945.iso / CORELSCS / CSCSI / OS2 / README.OB < prev    next >
Encoding:
Text File  |  1993-11-12  |  2.1 KB  |  68 lines

  1. KNOWN PROBLEMS IN THE OS/2 CORELSCSI VERSION 
  2. ============================================
  3.  
  4. MAXTOR/RICOH 800 WORM DEVICE DRIVER
  5. -----------------------------------
  6.  
  7.  By default, the installation puts CORELDRV.SYS in the CONFIG.SYS file.
  8.  For Maxtor/Ricoh 800 WORM drives, you must replace the CORELDRV.SYS 
  9.  device driver with 800.SYS. The device driver 800.SYS is located in the
  10.  CORELDRV/OS2 sub-directory on this diskette.
  11.  
  12.  To replace the CORELDRV.SYS device driver
  13.  
  14.  1. Edit CONFIG.SYS using a text editor.
  15.  
  16.  -- or --
  17.  
  18.     Use the custom configuration (available from the INSTALL main
  19.     menu) to change the UNIVERSAL driver option to 800.SYS driver
  20.     on the Device Driver Options screen.
  21.  
  22. HISTORY
  23. -------
  24.  
  25.  Performing a file name search through the history markers may
  26.  cause the PC to hang. If this occurs:
  27.  
  28.  1. Shut down the PC and all peripherals.
  29.  2. Reboot the system.
  30.  3. Retry the file name search.
  31.  
  32.  
  33. CDCHANGE
  34. --------
  35.  
  36.  If you use CDCHANGE to access multiple CDs with a Pioneer CD-ROM
  37.  drive, let the change complete before you try to access the 
  38.  selected CD. If the change isn't complete, you may need to reset
  39.  the drive.
  40.  
  41.  
  42. CRC ERROR WHEN USING MULTIPLE VOLUMES
  43. -------------------------------------
  44.  
  45.  When you use multiple volumes on a rewritable cartridge, 
  46.  CorelSCSI may display cyclic redundancy check (CRC) errors 
  47.  when you try to access any partition other than the first one. 
  48.  In DVRSTAT, this error is identified as CHECK CONDITION 305,
  49.  MEDIUM ERROR 03, SENSE CODE 11.
  50.  
  51.  To eliminate the CRC errors, try reformatting the cartridge 
  52.  using CFORMAT with the /LOWLEVEL and /ZERO options.
  53.  
  54.  
  55.  CFORMAT
  56.  -------
  57.  
  58.  If you're using an Adaptec host adapter, you may receive an error 
  59.  message while using CFORMAT to initialize a new WORM cartridge. 
  60.  This error is caused by versions of Adaptec's .ADD driver prior 
  61.  to December 1992.
  62.  
  63.  To obtain the current release of Adaptec's .ADD driver, call 
  64.  Adaptec's technical support at (408) 945-2550. If you have a 