- Recommendation K.11
-
-
-
- 1. Add a new paragraph to point 1.6.3:
-
-
-
- "To avoid disturbances in telecommunication circuits caused by striking protective devices, the striking
- voltage values and the numbers of arrestors should be considered."
-
-
-
- 2. Add new point 2.6:
-
-
-
- "2.6 Recommended policy
-
-
-
- Where lines in a telecommunications network are exposed to frequent or severe disturbances from
- power line faults or lightning, the voltage of these lines relative to local earth potential should be limited
- either by connecting protective devices between the line conductors and earth or by using appropriate
- construction methods for the line."
-
-
-
- 3. Point 4.3, second line, replace "may be limited" by "should be limited".
-