home *** CD-ROM | disk | FTP | other *** search
/ InfoMagic Standards 1993 July / Disc.iso / ccitt / 1988 / troff / 8_5_06.tro < prev    next >
Encoding:
Text File  |  1991-12-22  |  87.2 KB  |  3,998 lines

  1. .rs
  2. .\" Troff code generated by TPS Convert from ITU Original Files
  3. .\"                 Not Copyright (~c) 1991 
  4. .\"
  5. .\" Assumes tbl, eqn, MS macros, and lots of luck.
  6. .TA 1c 2c 3c 4c 5c 6c 7c 8c
  7. .ds CH
  8. .ds CF
  9. .EQ
  10. delim @@
  11. .EN
  12. .nr LL 40.5P
  13. .nr ll 40.5P
  14. .nr HM 3P
  15. .nr FM 6P
  16. .nr PO 4P
  17. .nr PD 9p
  18. .po 4P
  19.  
  20. .rs
  21. \v'|.5i'
  22. .LP
  23. \fBMONTAGE:\ \fR DEBUT DU X.225 EN TETE DE CETTE PAGE
  24. .sp 2P
  25. .LP
  26. \v'40P'
  27. \fB8\fR     \fBStructure and encoding of SPDUs\fR 
  28. .sp 1P
  29. .RT
  30. .sp 1P
  31. .LP
  32. 8.1
  33.     \fITSDU structure\fR 
  34. .EF '%    Fascicle\ VIII.5\ \(em\ Rec.\ X.225''
  35. .OF '''Fascicle\ VIII.5\ \(em\ Rec.\ X.225    %'
  36. .sp 9p
  37. .RT
  38. .PP
  39. Each TSDU consists of one or more SPDUs complying with the
  40. requirements for concatenation (see \(sc\ 6.3.7).
  41. .PP
  42. Each SPDU within a TSDU consists of one or more octets that are
  43. numbered sequentially starting from 1.
  44. .PP
  45. Each octet within an SPDU consists of eight bits numbered\ 8 to\ 1
  46. where\ 1 is the low ordered bit.
  47. .PP
  48. The sequence of octets within an SPDU and the sequence of bits within an 
  49. octet are defined for each SPDU in \(sc\ 8.3, with the additional convention 
  50. that where the text refers to bits within a two\(hyoctet field and the bits are
  51. numbered\ 16 to\ 1, then\ 1 is the low order bit and the octet containing 
  52. bits\ 16 to\ 9 precedes the octet containing bits\ 8 to\ 1 in the SPDU. 
  53. .bp
  54. .PP
  55. Within each TSDU:
  56. .RT
  57. .LP
  58.     a)
  59.     the sequential ordering of SPDUs is maintained;
  60. .LP
  61.     b)
  62.     the ordering of the octets is maintained in the same order
  63. as in the SPDU;
  64. .LP
  65.     c)
  66.     the ordering of bits within each TSDU is maintained in the
  67. same order as in the SPDU (i.e.\ the low order bit is mapped onto
  68. the low order bit and the high order bit is mapped onto the high
  69. order bit).
  70. .PP
  71. \fINote\ 1\fR \ \(em\ The TSDU structure is illustrated in Figure\ 4/X.225.
  72. The integrity of this structure is maintained over a transport connection. 
  73. This Recommendation does not define the way in which the TSDU is transmitted. 
  74. .PP
  75. \fINote\ 2\fR \ \(em\ When the structure of an SPDU is illustrated in this
  76. Recommendation, the following convention is used:
  77. .RT
  78. .LP
  79.     a)
  80.     octets are shown with the lowest numbered octet to the left,
  81. higher numbered octets being shown further to the right;
  82. .LP
  83.     b)
  84.     within an octet, bits are shown with bit\ 8 to the left and
  85. bit\ 1 to the right.
  86. .LP
  87. .rs
  88. .sp 14P
  89. .ad r
  90. \fBFigure 4/X.225, p.\fR 
  91. .sp 1P
  92. .RT
  93. .ad b
  94. .RT
  95. .sp 1P
  96. .LP
  97. 8.2
  98.     \fISPDU structure\fR 
  99. .sp 9p
  100. .RT
  101. .PP
  102. This subsection specifies the general structure of SPDUs in terms of their 
  103. constituent fields. This structure is illustrated in Figure\ 5/X.225. 
  104. .PP
  105. Codings and structural requirements specific to particular SPDUs are specified 
  106. in \(sc\ 8.3. 
  107. .PP
  108. Examples of valid SPDU structure are illustrated in
  109. Figure\ 6/X.225.
  110. .RT
  111. .sp 1P
  112. .LP
  113. 8.2.1
  114.     \fISPDUs\fR 
  115. .sp 9p
  116. .RT
  117. .PP
  118. SPDUs shall contain, in the following order:
  119. .RT
  120. .LP
  121.     a)
  122.     \fIthe SI field\fR that identifies the type of SPDU (see Note);
  123. .LP
  124.     b)
  125.     \fIthe LI field\fR that indicates the length of the associated
  126. parameter field defined in \(sc\ 8.2.1\|c);
  127. .LP
  128.     c)
  129.     \fIthe parameter field\fR which, if present, consists of the
  130. PGI units (see \(sc\ 8.2.2) and/or PI units (see \(sc\ 8.2.3) defined
  131. for the SPDU;
  132. .LP
  133.     d)
  134.     \fIthe user information field\fR , if defined for the SPDU and if
  135. present.
  136. .PP
  137. \fINote\fR \ \(em\ The SI field encompasses both the CI field and the RI
  138. field defined in Recommendation\ T.62. The protocol specified in this
  139. Recommendation does not require a distinction to be made between these two
  140. fields.
  141. .sp 1P
  142. .LP
  143. 8.2.2
  144.     \fIPGI units\fR 
  145. .sp 9p
  146. .RT
  147. .PP
  148. PGI units shall contain, in the following order:
  149. .RT
  150. .LP
  151.     a)
  152.     \fIthe PGI field\fR that identifies the parameter group;
  153. .LP
  154.     b)
  155.     \fIthe LI field\fR that indicates the length of the associated
  156. parameter field defined in \(sc\ 8.2.2\ c);
  157. .bp
  158. .LP
  159.     c)
  160.     \fIthe parameter field\fR which, if present, consists of
  161. either:
  162. .LP
  163.     1)
  164.     a single parameter value (see Note); or
  165. .LP
  166.     2)
  167.     one or more PI units (see \(sc\ 8.2.3).
  168. .PP
  169. \fINote\fR \ \(em\ A PGI unit with one parameter is structurally equivalent 
  170. to a PI unit, but the distinction has been retained in order to maintain 
  171. compatibility with Recommendation\ T.62.
  172. .LP
  173. .rs
  174. .sp 12P
  175. .ad r
  176. \fBFigure 5/X.225, p.\fR 
  177. .sp 1P
  178. .RT
  179. .ad b
  180. .RT
  181. .LP
  182. .rs
  183. .sp 31P
  184. .ad r
  185. \fBFigure 6/X.225, p.\fR 
  186. .sp 1P
  187. .RT
  188. .ad b
  189. .RT
  190. .LP
  191. .bp
  192. .sp 1P
  193. .LP
  194. 8.2.3
  195.     \fIPI units\fR 
  196. .sp 9p
  197. .RT
  198. .PP
  199. PI units shall contain, in the following order:
  200. .RT
  201. .LP
  202.     a)
  203.     the \fIPI field\fR that identifies the parameter;
  204. .LP
  205.     b)
  206.     the \fILI field\fR that indicates the length of the associated
  207. parameter field defined in \(sc\ 8.2.3\ c);
  208. .LP
  209.     c)
  210.     the \fIparameter field\fR which, if present, consists of the
  211. parameter value.
  212. .sp 1P
  213. .LP
  214. 8.2.4
  215.     \fIIdentifier fields\fR 
  216. .sp 9p
  217. .RT
  218. .PP
  219. The SI field shall comprise one octet. The value of the SI field, specified 
  220. as a decimal number in \(sc\ 8.3, shall be encoded as a binary number. 
  221. .PP
  222. The PGI and PI fields shall each comprise one octet and shall contain a 
  223. PGI or PI code respectively. The PGI and PI codes are expressed as decimal 
  224. numbers in the tables in \(sc\ 8.3 and shall be encoded as a binary number.
  225. .RT
  226. .sp 1P
  227. .LP
  228. 8.2.5
  229.     \fILength indicator field\fR 
  230. .sp 9p
  231. .RT
  232. .PP
  233. The value of the LI field is expressed as a binary number
  234. representing the length, in octets, of the associated parameter field (see
  235. Note). A value of zero indicates that the associated parameter field is
  236. absent.
  237. .PP
  238. LI fields indicating lengths within the range 0\(hy254 shall comprise one 
  239. octet. 
  240. .PP
  241. LI fields indicating lengths within the range 255\(hy65\|535 shall
  242. comprise
  243. three octets. The first octet shall be coded\ 1111\ 1111 and the second 
  244. and third octets shall contain the length of the associated parameter field 
  245. with the high order bits in the first of these two octets. 
  246. .PP
  247. \fINote\fR \ \(em\ The value of the LI field does not include either itself 
  248. or any subsequent user information. 
  249. .RT
  250. .sp 1P
  251. .LP
  252. 8.2.6
  253.     \fIParameter fields\fR 
  254. .sp 9p
  255. .RT
  256. .PP
  257. PGI units and PI units defined as mandatory in the tables in \(sc\ 8.3 
  258. shall contain a parameter field of one or more octets. 
  259. .PP
  260. Any PGI unit or PI unit defined as non\(hymandatory in the tables in
  261. \(sc\ 8.3 may be omitted if it is not required for conveying information 
  262. (i.e. a 
  263. parameter value). If a PGI unit or a PI unit contains an LI field with the
  264. value zero, the associated parameter field is absent (see Note) and the 
  265. value of the parameter field shall be considered as its default value. 
  266. .PP
  267. \fINote\fR \ \(em\ It is recommended that if a non\(hymandatory parameter is
  268. absent, the associated PGI (or PI) and LI fields should not be included 
  269. in the SPDU. 
  270. .PP
  271. PGI units and PI units within the same nesting level shall be ordered in 
  272. increasing value of their PGI and PI codes. 
  273. .PP
  274. PGI or PI units containing:
  275. .RT
  276. .LP
  277.     a)
  278.     a PGI or PI code listed in Annex\ C,
  279. .LP
  280.     b)
  281.     a PGI or PI code not listed in \(sc 8.3 or in Annex C,
  282. .LP
  283. are defined as valid.
  284. .PP
  285. \fINote\fR \ \(em\ See \(sc A.4.3 for actions to be taken by the SPM
  286. on receipt of SPDUs containing these PGI or PI units.
  287. .sp 1P
  288. .LP
  289. 8.2.7
  290.     \fIParameter values\fR 
  291. .sp 9p
  292. .RT
  293. .PP
  294. Bits within a parameter field which are indicated as reserved shall have 
  295. those bits set to zero in the SPDU. 
  296. .PP
  297. \fINote\fR \ \(em\ See \(sc A.4.3 for actions to be taken by the SPM
  298. on receipt of SPDUs containing such bits.
  299. .RT
  300. .sp 1P
  301. .LP
  302. 8.2.8
  303.     \fIUser information fields\fR 
  304. .sp 9p
  305. .RT
  306. .PP
  307. Segments of a segmented SSDU shall be contained in the User
  308. Information Fields of SPDUs such that the order of the segments is maintained. 
  309. An SSDU which is not segmented shall be contained in the User Information 
  310. Field of a single SPDU. The order of the octets and the order of the bits in
  311. the SSDU shall be maintained in the SPDUs.
  312. .bp
  313. .RT
  314. .sp 1P
  315. .LP
  316. 8.3
  317.     \fISPDU identifiers and associated parameter fields\fR 
  318. .sp 9p
  319. .RT
  320. .PP
  321. The SPDUs specified in the remainder of this subsection do not,
  322. with certain exceptions, consider the case where an SSDU is segmented. When
  323. protocol version\ 2 is selected, most SSDUs may be segmented. (The circumstances 
  324. under which an SSDU may be segmented are specified in \(sc\ 6.3.5.) The 
  325. additional encoding requirements when an SSDU is segmented are specified 
  326. in \(sc\ 8.4. 
  327. .RT
  328. .sp 2P
  329. .LP
  330. 8.3.1
  331.     \fICONNECT (CN) SPDU\fR 
  332. .sp 1P
  333. .RT
  334. .PP
  335. 8.3.1.1
  336. The SI field shall contain the value 13.
  337. .sp 9p
  338. .RT
  339. .PP
  340. 8.3.1.2
  341. The parameter fields shall be as specified in Table\ 11/X.225.
  342. .PP
  343. 8.3.1.3
  344. The Calling SS\(hyuser Reference PV field shall be as defined by
  345. the calling SS\(hyuser.
  346. .PP
  347. 8.3.1.4
  348. The Common Reference PV field shall be as defined by the calling   SS\(hyuser.
  349. .PP
  350. 8.3.1.5
  351. The Additional Reference Information PV field shall be as defined by the 
  352. calling SS\(hyuser. 
  353. .PP
  354. 8.3.1.6
  355. If the Connect/Accept Item is absent, the default values defined for the 
  356. enclosed PI units shall apply. 
  357. .PP
  358. 8.3.1.7
  359. The Protocol Options PV field shall indicate whether or not the
  360. initiator is able to receive extended concatenated SPDUs (see \(sc\ 6.3.7). The
  361. encoding for this field shall be:
  362. .LP
  363.     a)
  364.     bit\ 1\ =\ 1\ :\ able to receive extended concatenated SPDUs;
  365. .LP
  366.     b)
  367.     bit\ 1\ =\ 0\ :\ not able to receive extended concatenated
  368. SPDUs.
  369. .LP
  370.     Bits 2\(hy8 are reserved.
  371. .PP
  372. If the Protocol Options PI unit or PV field is absent, SPDUs with extended 
  373. concatenation cannot be received. 
  374. .PP
  375. 8.3.1.8
  376. The TSDU Maximum Size PV shall be present if a TSDU
  377. Minimum Size PV is proposed:
  378. .LP
  379.     a)
  380.     the first two octets of the PV field shall contain the
  381. proposed maximum TSDU size, expressed in octets, in the
  382. direction from the initiator to the responder, encoded as a
  383. binary number, where the first of the two octets is the high
  384. order part of the number;
  385. .LP
  386.     b)
  387.     the second two octets of the PV field shall contain the
  388. proposed maximum TSDU size, expressed in octets, in the
  389. direction from the responder to the initiator, encoded as a
  390. binary number, where the first of the two octets is the high
  391. order part of the number.
  392. .PP
  393. If this parameter is not present, the TSDU Maximum Size is not
  394. limited over the session connection. If either pair of octets has the value
  395. zero, the TSDU size is not limited in the direction of transfer associated
  396. with that pair of octets.
  397. .PP
  398. 8.3.1.9
  399. The bits in the Version Number PV field shall indicate which
  400. protocol versions are proposed for use over the session connection:
  401. .LP
  402.     a)
  403.     bit 1 protocol version 1;
  404. .LP
  405.     b)
  406.     bit 1 protocol version 2.
  407. .LP
  408.     Bits 3\(hy8 are reserved.
  409. .PP
  410. The encoding for each bit shall be:
  411. .LP
  412.     c)
  413.     0\ :\ use of the protocol version not proposed;
  414. .LP
  415.     d)
  416.     1\ :\ use of the protocol version proposed.
  417. .PP
  418. If this PI unit or PV field is absent, the default shall be
  419. protocol version 1.
  420. .LP
  421. 8.3.1.10\ \ The Initial Serial Number PV field shall be present if the
  422. activity management functional unit is not proposed and any of the minor
  423. synchronize, major synchronize or resynchronize functional units are proposed. 
  424. As an SS\(hyuser option, an Initial Serial Number PV field may be present 
  425. if the activity management functional unit is proposed provided that any of
  426. the minor synchronize, major synchronize or resynchronize functional units 
  427. are also proposed. 
  428. .bp
  429. .ce
  430. \fBH.T. [T11.225]\fR 
  431. .ce
  432. TABLE\ 11/X.225
  433. .ce
  434. \fBParameters of the CONNECT SPDU\fR 
  435. .ps 9
  436. .vs 11
  437. .nr VS 11
  438. .nr PS 9
  439. .TS
  440. center box;
  441. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  442. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  443. _
  444. .T&
  445. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) , ^  | ^  | ^  | l | c | c | c | l 
  446. ^  | ^  | ^  | l | c | c | c | l.
  447. Connection identifier    nm    1    Calling SS\(hyuser reference    nm    10    64\ octets  maximum    T{
  448. \(sc\ 7.1.1\|a)\|1)
  449. \(sc\ 8.3.1.3
  450. T}
  451.             Common reference    nm    11    64\ octets  maximum    T{
  452. \(sc\ 7.1.1\|a)\|2)
  453. \(sc\ 8.3.1.4
  454. T}    T{
  455. Additional reference information
  456. T}    nm    12    4\ octets  maximum    T{
  457. \(sc\ 7.1.1\|a)\|3)
  458. \(sc\ 8.3.1.5
  459. T}
  460. _
  461. .T&
  462. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) , ^  | ^  | ^  | l | c | c | c | l 
  463. ^  | ^  | ^  | l | c | c | c | l 
  464. ^  | ^  | ^  | l | c | c | c | l 
  465. ^  | ^  | ^  | l | c | c | c | l.
  466. T{
  467. Connect/Accept
  468. item (see \(sc\ 8.3.1.6)
  469. T}    nm    5    Protocol options    m    19    1\ octet    T{
  470. \(sc\ 7.1.1\|b)\|1)
  471. \(sc\ 8.3.1.7
  472. T}
  473.             TSDU maximum size    nm    21    4 octets    T{
  474. \(sc\ 7.1.1\|b)\|2)
  475. \(sc\ 8.3.1.8
  476. T}    Version number    m    22    1 octet    T{
  477. \(sc\ 7.1.1\|b)\|3)
  478. \(sc\ 8.3.1.9
  479. T}    Initial serial number    nm    23    6\ octets  maximum    T{
  480. \(sc\ 7.1.1\|b)\|4)
  481. \(sc\ 8.3.1.10
  482. T}    Token setting item    nm    26    1 octet    T{
  483. \(sc\ 7.1.1\|b)\|5)
  484. \(sc\ 8.3.1.11
  485. T}
  486. _
  487. .T&
  488. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  489.             Session user requirements    nm    20    2\ octets    T{
  490. \(sc\ 7.1.1\|c)
  491. \(sc\ 8.3.1.12
  492. T}
  493. _
  494. .T&
  495. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  496.             Calling session selector    nm    51    16\ octets  maximum    T{
  497. \(sc\ 7.1.1\|d)
  498. \(sc\ 8.3.1.13
  499. T}
  500. _
  501. .T&
  502. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  503.             Called session selector    nm    52    16\ octets  maximum    T{
  504. \(sc\ 7.1.1\|d)
  505. \(sc\ 8.3.1.14
  506. T}
  507. _
  508. .T&
  509. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  510. User data    nm    193                512\ octets  maximum    T{
  511. \(sc\ 7.1.1\|e)
  512. \(sc\ 8.3.1.15
  513. T}
  514. _
  515. .T&
  516. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  517.             Data overflow    nm    60    1\ octet    T{
  518. \(sc\ 7.1.1\|f
  519. )
  520. \(sc\ 8.3.1.17
  521. T}
  522. _
  523. .T&
  524. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  525. Extended user data    nm    194                10\|240\ octets  maximum    T{
  526. \(sc\ 7.1.1\|g)
  527. \(sc\ 8.3.1.16
  528. m:
  529. mandatory.
  530. nm:
  531. not mandatory (see \(sc\ 8.2.6).
  532. .parag
  533. T}
  534. _
  535. .TE
  536. .nr PS 9
  537. .RT
  538. .ad r
  539. \fBtableau 11/X.225 [T11.225], p. 4\fR 
  540. .sp 1P
  541. .RT
  542. .ad b
  543. .RT
  544. .LP
  545. .sp 6
  546. .bp
  547. .PP
  548. Each digit of the serial number is encoded as an octet, as
  549. follows:
  550. .LP
  551.     a)
  552.     0\ :\ 0011\ 0000;
  553. .LP
  554.     b)
  555.     1\ :\ 0011\ 0001;
  556. .LP
  557.     c)
  558.     2\ :\ 0011\ 0010;
  559. .LP
  560.     d)
  561.     3\ :\ 0011\ 0011;
  562. .LP
  563.     e)
  564.     4\ :\ 0011\ 0100;
  565. .LP
  566.     f
  567. )
  568.     5\ :\ 0011\ 0101;
  569. .LP
  570.     g)
  571.     6\ :\ 0011\ 0110;
  572. .LP
  573.     h)
  574.     7\ :\ 0011\ 0111;
  575. .LP
  576.     i)
  577.     8\ :\ 0011\ 1000;
  578. .LP
  579.     j)
  580.     9\ :\ 0011\ 1001.
  581. .PP
  582. Serial number can range from 0 to 999\|999. The most significant
  583. digit is encoded first in the PV field. Leading zeros may be omitted.
  584. .LP
  585. 8.3.1.11\ \ The Token Setting Item PV field, if present, shall indicate the
  586. initial position of the tokens. The bits of the Token Setting Item PV field 
  587. are defined as bit pairs: 
  588. .LP
  589.     a)
  590.     bits\ 8,\ 7\ release token;
  591. .LP
  592.     b)
  593.     bits\ 6,\ 5\ major/activity token;
  594. .LP
  595.     c)
  596.     bits\ 4,\ 3\ synchronize\(hyminor token;
  597. .LP
  598.     d)
  599.     bits\ 2,\ 1\ data token.
  600. .PP
  601. The encoding for each bit pair shall be:
  602. .LP
  603.     e)
  604.     00\ :\ initiator's side;
  605. .LP
  606.     f
  607. )
  608.     01\ :\ responder's side;
  609. .LP
  610.     g)
  611.     10\ :\ called SS user's choice;
  612. .LP
  613.     h)
  614.     11\ :\ reserved.
  615. .PP
  616. The values are relevant only if the appropriate functional units are requested 
  617. in the Session User Requirements parameter. If no functional unit requiring 
  618. a token has been requested, this parameter need not be present. 
  619. .PP
  620. If this PI unit or PV field is absent, the default shall be that all tokens 
  621. whose availability is proposed in the Session User Requirements 
  622. parameter are assigned to the calling\ SS\(hyuser.
  623. .RT
  624. .LP
  625. 8.3.1.12\ \ The bits in the Session User Requirements PV field shall
  626. indicate the functional units proposed by the calling SS\(hyuser, for use over
  627. this session connection:
  628. .LP
  629.     a)
  630.     bit\ \ 1\ half\(hyduplex functional unit;
  631. .LP
  632.     b)
  633.     bit\ \ 2\ duplex functional unit;
  634. .LP
  635.     c)
  636.     bit\ \ 3\ expedited data functional unit;
  637. .LP
  638.     d)
  639.     bit\ \ 4\ minor synchronize functional unit;
  640. .LP
  641.     e)
  642.     bit\ \ 5\ major synchronize functional unit;
  643. .LP
  644.     f
  645. )
  646.     bit\ \ 6\ resynchronize functional unit;
  647. .LP
  648.     g)
  649.     bit\ \ 7\ activity management functional unit;
  650. .LP
  651.     h)
  652.     bit\ \ 8\ negotiated release functional unit;
  653. .LP
  654.     i)
  655.     bit\ \ 9\ capability data functional unit;
  656. .LP
  657.     j
  658. )
  659.     bit\ 10\ exceptions functional unit;
  660. .LP
  661.     k)
  662.     bit\ 11\ typed data functional unit.
  663. .LP
  664.     Bits 12\(hy16 are reserved.
  665. .PP
  666. When this parameter is present, at least one of the half\(hyduplex
  667. and the duplex functional units shall be proposed.
  668. .PP
  669. The encoding for each bit shall be:
  670. .RT
  671. .LP
  672.     l)
  673.     0\ :\ use of functional unit not proposed;
  674. .LP
  675.     m)
  676.     1\ :\ use of functional unit proposed.
  677. .PP
  678. When this parameter is absent, the default shall be as though
  679. bits\ 1, 4, 7, 9 and\ 10 are set to one and the remaining bits are set to zero.
  680. .bp
  681. .LP
  682. 8.3.1.13\ \ The Calling Session Selector, if present, shall be derived from
  683. the Calling Session Address supplied by the calling SS\(hyuser. When this
  684. parameter is absent, the default shall be as though this parameter was
  685. set to a null value.
  686. .LP
  687. 8.3.1.14\ \ The Called Session Selector, if present, shall be derived from
  688. the Called Session Address supplied by the calling SS\(hyuser. When this
  689. parameter is absent, the default shall be as though this parameter was
  690. set to a null value.
  691. .LP
  692. 8.3.1.15\ \ The User Data PV field, if present, shall contain user data
  693. supplied by the calling SS\(hyuser.
  694. .LP
  695. 8.3.1.16\ \ The Extended User Data parameter, if present, shall contain 
  696. user data supplied by the calling SS\(hyuser. This parameter shall be present 
  697. if the Data 
  698. Overflow parameter is present. This parameter shall not be present if protocol 
  699. version\ 1 is proposed. 
  700. .PP
  701. Only one of the User Data and Extended User Data parameters may be present 
  702. (see \(sc\ 7.1.1). 
  703. .LP
  704. 8.3.1.17\ \ The Data Overflow parameter, if present, shall indicate that 
  705. there is more than 10\|240\ octets of user data to be transformed. This 
  706. parameter shall 
  707. not be present if protocol version\ 1 is proposed.
  708. .PP
  709. The encoding of this field shall be:
  710. .LP
  711.     bit 1\ =\ 1 more than 10\|240 octets of user data;
  712. .LP
  713.     bit 1 shall never be set equal to 0.
  714. .PP
  715. Bits 2\(hy8 are reserved.
  716. .PP
  717. If the Data Overflow PI unit or PV field is absent, there are not more 
  718. than 10\|240 octets of user data. 
  719. .RT
  720. .sp 2P
  721. .LP
  722. 8.3.2
  723.     \fIOVERFLOW ACCEPT (OA) SPDU\fR 
  724. .sp 1P
  725. .RT
  726. .PP
  727. 8.3.2.1
  728. The SI field shall contain the value 16.
  729. .sp 9p
  730. .RT
  731. .PP
  732. 8.3.2.2
  733. The parameter fields shall be as specified in Table\ 12/X.225.
  734. .ce
  735. \fBH.T. [T12.225]\fR 
  736. .ce
  737. TABLE\ 12/X.225
  738. .ce
  739. \fBParameters of the OVERFLOW ACCEPT SPDU\fR 
  740. .ps 9
  741. .vs 11
  742. .nr VS 11
  743. .nr PS 9
  744. .TS
  745. center box;
  746. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  747. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  748. _
  749. .T&
  750. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  751.             TSDU maximum size    nm    21    4 octets    \(sc\ 7.2.1\|a) \(sc\ 8.3.2.3
  752. _
  753. .T&
  754. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  755.             Version number    m    22    1 octet    T{
  756. \(sc\ 7.2.1\|b)
  757. \(sc\ 8.3.2.4
  758. m:
  759. mandatory.
  760. nm:
  761. not mandatory (see \(sc\ 8.2.6).
  762. .parag
  763. T}
  764. _
  765. .TE
  766. .nr PS 9
  767. .RT
  768. .ad r
  769. \fBTable 12/X.225 [T12.225], p.\fR 
  770. .sp 1P
  771. .RT
  772. .ad b
  773. .RT
  774. .PP
  775. 8.3.2.3
  776. The TSDU Maximum Size parameter shall be present if a TSDU maximum size 
  777. is proposed by the receiver. The encoding and default for this field is 
  778. defined in \(sc\ 8.3.1.8.
  779. .PP
  780. 8.3.2.4
  781. In the Version Number PV field bit 2 shall have the value 1
  782. indicating that protocol version\ 2 is proposed (and selected) for use 
  783. over this session connection. Bit\ 1 shall have the value\ 0 indicating 
  784. that protocol 
  785. version\ 1 is not proposed.
  786. .PP
  787. Bits 3\(hy8 are reserved.
  788. .bp
  789. .sp 2P
  790. .LP
  791. 8.3.3
  792.     \fICONNECT DATA OVERFLOW (CDO) SPDU\fR 
  793. .sp 1P
  794. .RT
  795. .PP
  796. 8.3.3.1
  797. The SI field shall contain the value 15.
  798. .sp 9p
  799. .RT
  800. .PP
  801. 8.3.3.2
  802. The parameter fields shall be as specified in Table\ 13/X.225.
  803. .ce
  804. \fBH.T. [T13.225]\fR 
  805. .ce
  806. TABLE\ 13/X.225
  807. .ce
  808. \fBParameters of the CONNECT DATA OVERFLOW\fR 
  809. .ps 9
  810. .vs 11
  811. .nr VS 11
  812. .nr PS 9
  813. .TS
  814. center box;
  815. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  816. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  817. _
  818. .T&
  819. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  820.             Enclosure item    m    25    1 octet    \(sc\ 7.3.1\|a) \(sc\ 8.3.3.3
  821. _
  822. .T&
  823. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  824. User data    nm    193                65\|528\ octets  maximum    T{
  825. \(sc\ 7.3.1\|b)
  826. \(sc\ 8.3.3.4
  827. m:
  828. mandatory.
  829. nm:
  830. not mandatory (see \(sc\ 8.2.6).
  831. .parag
  832. T}
  833. _
  834. .TE
  835. .nr PS 9
  836. .RT
  837. .ad r
  838. \fBTable 13/X.225 [T13.225], p.\fR 
  839. .sp 1P
  840. .RT
  841. .ad b
  842. .RT
  843. .PP
  844. 8.3.3.3
  845. The Enclosure Item PV field shall indicate whether or not this
  846. SPDU is the end of the SSDU.
  847. .PP
  848. The encoding for this field shall be:
  849. .LP
  850.     a)
  851.     bit\ 1\ =\ 0\ not beginning of SSDU;
  852. .LP
  853.     b)
  854.     bit\ 2\ =\ 1\ end of SSDU;
  855. .LP
  856.     bit\ 2\ =\ 0\ not end of SSDU.
  857. .LP
  858.     Bits 3\(hy8 are reserved.
  859. .PP
  860. 8.3.3.4
  861. The User Data field, if present, shall contain a segment of the
  862. associated SSDU. The User Data field shall be present if the Enclosure Item
  863. has bit\ 2\ =\ 0.
  864. .sp 2P
  865. .LP
  866. 8.3.4
  867.     \fIACCEPT (AC) SPDU\fR 
  868. .sp 1P
  869. .RT
  870. .PP
  871. 8.3.4.1
  872. The SI field shall contain the value 14.
  873. .sp 9p
  874. .RT
  875. .PP
  876. 8.3.4.2
  877. The parameter fields shall be as specified in Table\ 14/X.225.
  878. .PP
  879. 8.3.4.3
  880. The Called SS\(hyuser Reference PV field shall be as defined by
  881. the called SS\(hyuser.
  882. .PP
  883. 8.3.4.4
  884. The Common Reference PV field shall be as defined by the called
  885. SS\(hyuser.
  886. .PP
  887. 8.3.4.5
  888. The Additional Reference Information PV field shall be as defined by the 
  889. called SS\(hyuser. 
  890. .PP
  891. 8.3.4.6
  892. If the Connect/Accept Item is absent, the default values defined for the 
  893. enclosed PI units shall apply. 
  894. .PP
  895. 8.3.4.7
  896. The Protocol Options PV field shall indicate whether or not the
  897. responder is able to receive extended concatenated SPDUs (see \(sc\ 6.3.7). The
  898. encoding and default for this field is defined in \(sc\ 8.3.1.7.
  899. .PP
  900. 8.3.4.8
  901. The TSDU Maximum Size parameter shall be present if a TSDU maximum size 
  902. is proposed by the receiver. The encoding and default for this field 
  903. is defined in \(sc\ 8.3.1.8. If an OVERFLOW ACCEPT SPDU has been sent previously, 
  904. the TSDU maximum size parameter shall have the same value as was indicated 
  905. on the OVERFLOW ACCEPT SPDU. 
  906. .bp
  907. .ce
  908. \fBH.T. [T14.225]\fR 
  909. .ce
  910. TABLE\ 14/X.225
  911. .ce
  912. \fBParameters of the ACCEPT SPDU\fR 
  913. .ps 9
  914. .vs 11
  915. .nr VS 11
  916. .nr PS 9
  917. .TS
  918. center box;
  919. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  920. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  921. _
  922. .T&
  923. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) , ^  | ^  | ^  | l | c | c | c | l 
  924. ^  | ^  | ^  | l | c | c | c | l.
  925. Connection identifier    nm    1    Called SS\(hyuser reference    nm    \ 9    64\ octets  maximum    T{
  926. \(sc\ 7.4.1\|a)\|1)
  927. \(sc\ 8.3.4.3
  928. T}
  929.             Common reference    nm    11    64\ octets  maximum    T{
  930. \(sc\ 7.4.1\|a)\|2)
  931. \(sc\ 8.3.4.4
  932. T}    T{
  933. Additional reference information
  934. T}    nm    12    4\ octets  maximum    T{
  935. \(sc\ 7.4.1\|a)\|3)
  936. \(sc\ 8.3.4.5
  937. T}
  938. _
  939. .T&
  940. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) , ^  | ^  | ^  | l | c | c | c | l 
  941. ^  | ^  | ^  | l | c | c | c | l 
  942. ^  | ^  | ^  | l | c | c | c | l 
  943. ^  | ^  | ^  | l | c | c | c | l.
  944. T{
  945. Connect/Accept item (see \(sc\ 8.3.4.6)
  946. T}    nm    5    Protocol options    m    19    1 octet    T{
  947. \(sc\ 7.4.1\|b)\|1)
  948. \(sc\ 8.3.4.7
  949. T}
  950.             TSDU maximum size    nm    21    4 octets    T{
  951. \(sc\ 7.4.1\|b)\|2)
  952. \(sc\ 8.3.4.8
  953. T}    Version number    m    22    1 octet    T{
  954. \(sc\ 7.4.1\|b)\|3)
  955. \(sc\ 8.3.4.9
  956. T}    Initial serial number    nm    23    6\ octets  maximum    T{
  957. \(sc\ 7.4.1\|b)\|4)
  958. \(sc\ 8.3.4.10
  959. T}    Token setting item    nm    26    1 octet    T{
  960. \(sc\ 7.4.1\|b)\|5)
  961. \(sc\ 8.3.4.11
  962. T}
  963. _
  964. .T&
  965. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  966.             Token item    nm    16    1 octet    T{
  967. \(sc\ 7.4.1\|c)
  968. \(sc\ 8.3.4.12
  969. T}
  970. _
  971. .T&
  972. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  973.             Session user requirements    nm    20    2 octets    T{
  974. \(sc\ 7.4.1\|d)
  975. \(sc\ 8.3.4.13
  976. T}
  977. _
  978. .T&
  979. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  980.             Calling session selector    nm    51    16\ octets  maximum    T{
  981. \(sc\ 7.4.1\|e)
  982. \(sc\ 8.3.4.14
  983. T}
  984. _
  985. .T&
  986. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  987.             Responding session selector    nm    52    16\ octets  maximum    T{
  988. \(sc\ 7.4.1\|e)
  989. \(sc\ 8.3.4.15
  990. T}
  991. _
  992. .T&
  993. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  994.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.4.17
  995. _
  996. .T&
  997. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  998. User data    nm    193                See reference    T{
  999. \(sc\ 7.4.1\|f
  1000. )
  1001. \(sc\ 8.3.4.16
  1002. m:
  1003. mandatory.
  1004. nm:
  1005. not mandatory (see \(sc\ 8.2.6).
  1006. .parag
  1007. T}
  1008. _
  1009. .TE
  1010. .nr PS 9
  1011. .RT
  1012. .ad r
  1013. \fBtableau 14/X.225 [T14.225], p. 7\fR 
  1014. .sp 1P
  1015. .RT
  1016. .ad b
  1017. .RT
  1018. .LP
  1019. .sp 6
  1020. .bp
  1021. .PP
  1022. 8.3.4.9
  1023. The Version Number PV field shall have the value and encoding
  1024. specified in \(sc\ 8.3.1.9.
  1025. .PP
  1026. If an OVERFLOW ACCEPT SPDU has been sent previously on this
  1027. session connection then the Version Number parameter shall have the same 
  1028. value as was indicated in the OVERFLOW ACCEPT SPDU. 
  1029. .LP
  1030. 8.3.4.10\ \ The Initial Serial Number PV field shall only be present if the
  1031. activity management functional unit is not selected and if any of the following 
  1032. functional units are selected: 
  1033. .LP
  1034.     a)
  1035.     minor synchronize functional unit;
  1036. .LP
  1037.     b)
  1038.     major synchronize functional unit;
  1039. .LP
  1040.     c)
  1041.     resynchronize functional unit.
  1042. .PP
  1043. The encoding for the Initial Serial Number PV field is defined
  1044. in \(sc\ 8.3.1.10.
  1045. .LP
  1046. 8.3.4.11\ \ The Token Setting Item PV field indicates the initial token
  1047. settings for each token available on this session connection. The bits and
  1048. encoding are defined in \(sc\ 8.3.1.11. In the case where the initial assignment 
  1049. of the related token was indicated as the called SS\(hyuser's choice (in 
  1050. the Token Setting Item PV field of the associated CONNECT SPDU), the field 
  1051. shall contain the value chosen by the called SS\(hyuser. Otherwise, the 
  1052. values set in the 
  1053. CONNECT SPDU must be returned. The value \*Qcalled SS\(hyuser's choice\*U 
  1054. is not a 
  1055. permitted value in the ACCEPT SPDU. The values are relevant only if the
  1056. appropriate functional units are requested in the Session User Requirements
  1057. parameter. If no functional unit requiring a token has been requested, this
  1058. parameter need not be present.
  1059. .LP
  1060. 8.3.4.12\ \ The Token Item PV field, if present, shall indicate which tokens
  1061. are requested by the called SS\(hyuser:
  1062. .LP
  1063.     a)
  1064.     bit\ 7\ =\ 1\ release token;
  1065. .LP
  1066.     b)
  1067.     bit\ 5\ =\ 1\ major/activity token;
  1068. .LP
  1069.     c)
  1070.     bit\ 3\ =\ 1\ synchronize\(hyminor token;
  1071. .LP
  1072.     d)
  1073.     bit\ 1\ =\ 1\ data token.
  1074. .LP
  1075.     Bits 2, 4, 6 and 8 are reserved.
  1076. .PP
  1077. Bits corresponding to tokens which are not available are
  1078. ignored.
  1079. .LP
  1080. 8.3.4.13\ \ The bits in the Session User Requirements PV field shall
  1081. indicate the functional units proposed by the called SS\(hyuser, for use 
  1082. over this session connection. This PV field shall not have both bit\ 1 
  1083. set (half\(hyduplex 
  1084. functional unit) and bit\ 2 set (duplex functional unit), but the chosen bit
  1085. must have been set in the CONNECT SPDU. The encoding and default value is
  1086. defined in \(sc\ 8.3.1.12.
  1087. .LP
  1088. 8.3.4.14\ \ The Calling Session Selector, if present, shall be the same value
  1089. as in the CONNECT SPDU.
  1090. .LP
  1091. 8.3.4.15\ \ The Responding Session Selector, if present, shall be derived from
  1092. the Responding Session Address supplied by the responding SS\(hyuser. When this
  1093. parameter is absent, the default shall be as though this parameter is set 
  1094. to a null value. 
  1095. .LP
  1096. 8.3.4.16\ \ The length of the User Data parameter is limited such that 
  1097. the total length (including SI and LI) of the SPDU does not exceed 65\|539\ 
  1098. octets. If the Enclosure Item parameter is present, the User Data parameter 
  1099. is mandatory. 
  1100. .LP
  1101. 8.3.4.17\ \ The Enclosure Item parameter, if present, shall indicate that the
  1102. SPDU is the beginning, but not end of the SSDU. This parameter shall not be
  1103. present if protocol version\ 1 is selected. The encoding for this field shall
  1104. be:
  1105. .LP
  1106.     a)
  1107.     bit\ 1\ =\ 1\ beginning of SSDU;
  1108. .LP
  1109.     b)
  1110.     bit\ 2\ =\ 0\ not end of SSDU.
  1111. .LP
  1112.     Bits 3\(hy8 are reserved.
  1113. .PP
  1114. See \(sc 8.4.2 for encoding subsequent SPDUs in the sequence.
  1115. .bp
  1116. .sp 2P
  1117. .LP
  1118. 8.3.5
  1119.     \fIREFUSE (RF) SPDU\fR 
  1120. .sp 1P
  1121. .RT
  1122. .PP
  1123. 8.3.5.1
  1124. The SI field shall contain the value 12.
  1125. .sp 9p
  1126. .RT
  1127. .PP
  1128. 8.3.5.2
  1129. The parameter fields shall be as specified in Table\ 15/X.225.
  1130. .ce
  1131. \fBH.T. [T15.225]\fR 
  1132. .ce
  1133. TABLE\ 15/X.225
  1134. .ce
  1135. \fBParameters of the REFUSE SPDU\fR 
  1136. .ps 9
  1137. .vs 11
  1138. .nr VS 11
  1139. .nr PS 9
  1140. .TS
  1141. center box;
  1142. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1143. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1144. _
  1145. .T&
  1146. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) , ^  | ^  | ^  | l | c | c | c | l 
  1147. ^  | ^  | ^  | l | c | c | c | l.
  1148. Connection identifier    nm    1    Called SS\(hyuser reference    nm    \ 9    64\ octets  maximum    T{
  1149. \(sc\ 7.5.1\|a)\|1)
  1150. \(sc\ 8.3.5.3
  1151. T}
  1152.             Common reference    nm    11    64\ octets  maximum    T{
  1153. \(sc\ 7.5.1\|a)\|2)
  1154. \(sc\ 8.3.5.4
  1155. T}    T{
  1156. Additional reference information
  1157. T}    nm    12    4\ octets  maximum    T{
  1158. \(sc\ 7.5.1\|a)\|3)
  1159. \(sc\ 8.3.5.5
  1160. T}
  1161. _
  1162. .T&
  1163. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1164.             Transport disconnect    nm    17    1\ octet    \(sc\ 7.5.1\|b) \(sc\ 8.3.5.6
  1165. _
  1166. .T&
  1167. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1168.             Session user requirements    nm    20    2\ octets    \(sc\ 7.5.1\|c) \(sc\ 8.3.5.7
  1169. _
  1170. .T&
  1171. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1172.             Version number    nm    22    1\ octet    \(sc\ 7.5.1\|d) \(sc\ 8.3.5.8
  1173. _
  1174. .T&
  1175. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1176.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.5.10
  1177. _
  1178. .T&
  1179. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1180.             Reason code    nm    50    See reference    T{
  1181. \(sc\ 7.5.1\|e)
  1182. \(sc\ 8.3.5.9
  1183. m:
  1184. mandatory.
  1185. nm:
  1186. not mandatory (see \(sc\ 8.2.6).
  1187. .parag
  1188. T}
  1189. _
  1190. .TE
  1191. .nr PS 9
  1192. .RT
  1193. .ad r
  1194. \fBTable 15/X.255 [T15.225], p.\fR 
  1195. .sp 1P
  1196. .RT
  1197. .ad b
  1198. .RT
  1199. .PP
  1200. 8.3.5.3
  1201. The Called SS\(hyuser Reference PV field shall be as defined by the called 
  1202. SS\(hyuser. 
  1203. .PP
  1204. 8.3.5.4
  1205. The Common Reference PV field shall be as defined by the called
  1206. SS\(hyuser.
  1207. .PP
  1208. 8.3.5.5
  1209. The Additional Reference Information PV field shall be as defined by the 
  1210. called SS\(hyuser. 
  1211. .PP
  1212. 8.3.5.6
  1213. The Transport Disconnect PV field shall indicate whether or not
  1214. the transport connection is to be kept. The encoding for this field shall
  1215. be:
  1216. .LP
  1217.     a)
  1218.     bit\ 1\ =\ 0\ transport connection is kept;
  1219. .LP
  1220.     b)
  1221.     bit\ 1\ =\ 1\ transport connection is released.
  1222. .LP
  1223.     Bits 2\(hy8 are reserved.
  1224. .PP
  1225. If this parameter is absent, the transport connection is
  1226. released.
  1227. .bp
  1228. .PP
  1229. 8.3.5.7
  1230. The Session User Requirements PV field shall only be present if
  1231. the Reason Code is 2 and shall indicate the functional units required by the
  1232. called SS\(hyuser and supported by the responder. The encoding shall be 
  1233. the same as in the CONNECT SPDU (see \(sc\ 8.3.1.12). 
  1234. .PP
  1235. 8.3.5.8
  1236. The Version Number PV field shall have the value and encoding
  1237. specified in \(sc\ 8.3.1.9. If an OVERFLOW ACCEPT SPDU has been sent previously 
  1238. on this session connection, then the Version Number parameter shall have 
  1239. the same value as was indicated in the OVERFLOW ACCEPT SPDU. 
  1240. .PP
  1241. 8.3.5.9
  1242. The Reason Code PV field shall contain a reason code in the first octet. 
  1243. Depending on the value of this first octet, additional octets may be 
  1244. used. The following values are defined for the first octet:
  1245. .LP
  1246.     a)
  1247.     0\ :
  1248.     rejection by the called SS user; reason not
  1249. specified;
  1250. .LP
  1251.     b)
  1252.     1\ :
  1253.     rejection by called SS\(hyuser due to temporary
  1254. congestion;
  1255. .LP
  1256.     c)
  1257.     2\ :
  1258.     rejection by called SS\(hyuser. The following
  1259. octets may be used for user data up to a length such
  1260. that the total length (including SI and LI)
  1261. of the SPDU does not exceed 65\|539\ octets;
  1262. .LP
  1263.     d)\ *
  1264.     128\ +
  1265.     1\ :
  1266.     session selector unknown;
  1267. .LP
  1268.     e)\ *
  1269.     128\ +
  1270.     2\ :
  1271.     SS\(hyuser not attached to SSAP;
  1272. .LP
  1273.     f
  1274. )
  1275.     128\ +
  1276.     3\ :
  1277.     SPM congestion at connect time;
  1278. .LP
  1279.     g)\ *
  1280.     128\ +
  1281.     4\ :
  1282.     proposed protocol versions not
  1283. supported;
  1284. .LP
  1285.     h)
  1286.     128\ +
  1287.     5\ :
  1288.     rejection by the SPM; reason not specified;
  1289. .LP
  1290.     i)
  1291.     128\ +
  1292.     6\ :
  1293.     rejection by the SPM; implementation
  1294. restriction stated in the PICS.
  1295. .PP
  1296. \fINote\fR \ \(em\ Reasons marked with an asterisk (*) may be reported to
  1297. the SS\(hyuser as persistent, others reported as transient.
  1298. .PP
  1299. All other values are reserved.
  1300. .PP
  1301. The Session User Requirements parameter may only be present if the
  1302. value of the reason code is\ 2. If the reason code has the value\ 2 and the
  1303. Session User Requirements parameter is not present, the default value shall 
  1304. be assumed (see \(sc\ 8.3.1.12). 
  1305. .PP
  1306. If the Enclosure Item parameter is present, the Reason Code parameter is 
  1307. mandatory and shall be followed by octets of user data. 
  1308. .RT
  1309. .LP
  1310. 8.3.5.10\ \ The Enclosure Item parameter, if present, shall be encoded as
  1311. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  1312. version\ 1 is selected.
  1313. .sp 2P
  1314. .LP
  1315. 8.3.6
  1316.     \fIFINISH (FN) SPDU\fR 
  1317. .sp 1P
  1318. .RT
  1319. .PP
  1320. 8.3.6.1
  1321. The SI field shall contain the value\ 9.
  1322. .sp 9p
  1323. .RT
  1324. .PP
  1325. 8.3.6.2
  1326. The parameter fields shall be as specified in Table 16/X.225.
  1327. .ce
  1328. \fBH.T. [T16.225]\fR 
  1329. .ce
  1330. TABLE\ 16/X.225
  1331. .ce
  1332. \fBParameters of the FINISH SPDU\fR 
  1333. .ps 9
  1334. .vs 11
  1335. .nr VS 11
  1336. .nr PS 9
  1337. .TS
  1338. center box;
  1339. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1340. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1341. _
  1342. .T&
  1343. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1344.             Transport disconnect    nm    17    1 octet    \(sc\ 7.6.1\|a) \(sc\ 8.3.6.3
  1345. _
  1346. .T&
  1347. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1348.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.6.5
  1349. _
  1350. .T&
  1351. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1352. User data    nm    193                See reference    T{
  1353. \(sc\ 7.6.1\|b)
  1354. \(sc\ 8.3.6.4
  1355. m:
  1356. mandatory.
  1357. nm:
  1358. not mandatory (see \(sc\ 8.2.6).
  1359. .parag
  1360. T}
  1361. _
  1362. .TE
  1363. .nr PS 9
  1364. .RT
  1365. .ad r
  1366. \fBTable 16/X.225 [T16.225], p.\fR 
  1367. .sp 1P
  1368. .RT
  1369. .ad b
  1370. .RT
  1371. .LP
  1372. .bp
  1373. .PP
  1374. 8.3.6.3
  1375. The Transport Disconnect PV field shall indicate whether or not
  1376. the transport connection is to be kept. The encoding for this field shall
  1377. be:
  1378. .LP
  1379.     a)
  1380.     bit\ 1\ =\ 0\ transport connection is kept;
  1381. .LP
  1382.     b)
  1383.     bit\ 1\ =\ 1\ transport connection is released.
  1384. .LP
  1385.     Bits 2\(hy8 are reserved.
  1386. .PP
  1387. If this parameter is absent, the transport connection shall be
  1388. released.
  1389. .PP
  1390. 8.3.6.4
  1391. The User Data PV field, if present, shall contain user data
  1392. supplied by the SS\(hyuser.
  1393. .PP
  1394. The length of the User Data parameter is limited such that the
  1395. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  1396. .PP
  1397. 8.3.6.5
  1398. The Enclosure Item parameter, if present, shall be encoded as
  1399. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  1400. version\ 1 is selected.
  1401. .sp 2P
  1402. .LP
  1403. 8.3.7
  1404.     \fIDISCONNECT (DN) SPDU\fR 
  1405. .sp 1P
  1406. .RT
  1407. .PP
  1408. 8.3.7.1
  1409. The SI field shall contain the value 10.
  1410. .sp 9p
  1411. .RT
  1412. .PP
  1413. 8.3.7.2
  1414. The parameter field shall be as specified in Table\ 17/X.225.
  1415. .LP
  1416. .sp 2
  1417. .ce
  1418. \fBH.T. [T17.225]\fR 
  1419. .ce
  1420. TABLE\ 17/X.225
  1421. .ce
  1422. \fBParameters of the DISCONNECT SPDU\fR 
  1423. .ps 9
  1424. .vs 11
  1425. .nr VS 11
  1426. .nr PS 9
  1427. .TS
  1428. center box;
  1429. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1430. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1431. _
  1432. .T&
  1433. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1434.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.7.4
  1435. _
  1436. .T&
  1437. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1438. User data    nm    193                See reference    T{
  1439. \(sc\ 7.7.1
  1440. \(sc\ 8.3.7.3
  1441. m:
  1442. mandatory.
  1443. nm:
  1444. not mandatory (see \(sc\ 8.2.6).
  1445. .parag
  1446. T}
  1447. _
  1448. .TE
  1449. .nr PS 9
  1450. .RT
  1451. .ad r
  1452. \fBTable 17/X.225 [T17.225], p.\fR 
  1453. .sp 1P
  1454. .RT
  1455. .ad b
  1456. .RT
  1457. .LP
  1458. .sp 2
  1459. .PP
  1460. 8.3.7.3
  1461. The User Data PV field, if present, shall contain user data
  1462. supplied by the SS\(hyuser.
  1463. .PP
  1464. The length of the User Data parameter is limited such that the
  1465. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  1466. .PP
  1467. 8.3.7.4
  1468. The Enclosure Item parameter, if present, shall be encoded as
  1469. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  1470. version\ 1 is selected.
  1471. .sp 2P
  1472. .LP
  1473. 8.3.8
  1474.     \fINOT FINISHED (NF) SPDU\fR 
  1475. .sp 1P
  1476. .RT
  1477. .PP
  1478. 8.3.8.1
  1479. The SI field shall contain the value 8.
  1480. .sp 9p
  1481. .RT
  1482. .PP
  1483. 8.3.8.2
  1484. The parameter field shall be as specified in Table\ 18/X.225.
  1485. .bp
  1486. .ce
  1487. \fBH.T. [T18.225]\fR 
  1488. .ce
  1489. TABLE\ 18/X.225
  1490. .ce
  1491. \fBParameters of the NOT FINISHED SPDU\fR 
  1492. .ps 9
  1493. .vs 11
  1494. .nr VS 11
  1495. .nr PS 9
  1496. .TS
  1497. center box;
  1498. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1499. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1500. _
  1501. .T&
  1502. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1503.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.8.4
  1504. _
  1505. .T&
  1506. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1507. User data    nm    193                See reference    T{
  1508. \(sc\ 7.8.1
  1509. \(sc\ 8.3.8.3
  1510. m:
  1511. mandatory.
  1512. nm:
  1513. not mandatory (see \(sc\ 8.2.6).
  1514. .parag
  1515. T}
  1516. _
  1517. .TE
  1518. .nr PS 9
  1519. .RT
  1520. .ad r
  1521. \fBTable 18/X.225 [T18.225], p.\fR 
  1522. .sp 1P
  1523. .RT
  1524. .ad b
  1525. .RT
  1526. .PP
  1527. 8.3.8.3
  1528. The User Data PV field, if present, shall contain user data
  1529. supplied by the SS\(hyuser. The length of the User Data parameter is limited 
  1530. such that the total length (including SI and LI) of the SPDU does not exceed 
  1531. 65\|539\ octets.
  1532. .PP
  1533. 8.3.8.4
  1534. The Enclosure Item parameter, if present, shall be encoded as
  1535. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  1536. version\ 1 is selected.
  1537. .sp 2P
  1538. .LP
  1539. 8.3.9
  1540.     \fIABORT (AB) SPDU\fR 
  1541. .sp 1P
  1542. .RT
  1543. .PP
  1544. 8.3.9.1
  1545. The SI field shall contain the value 25.
  1546. .sp 9p
  1547. .RT
  1548. .PP
  1549. 8.3.9.2
  1550. The parameter fields shall be as specified in Table\ 19/X.225.
  1551. .LP
  1552. .sp 1
  1553. .ce
  1554. \fBH.T. [T19.225]\fR 
  1555. .ce
  1556. TABLE\ 19/X.225
  1557. .ce
  1558. \fBParameters of the ABORT SPDU\fR 
  1559. .ps 9
  1560. .vs 11
  1561. .nr VS 11
  1562. .nr PS 9
  1563. .TS
  1564. center box;
  1565. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1566. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1567. _
  1568. .T&
  1569. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1570.             Transport disconnect    m    17    1\ octet    \(sc\ 7.9.1\|a) \(sc\ 8.3.9.3
  1571. _
  1572. .T&
  1573. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1574.             Reflect parameter values    nm    49    9\ octets  maximum    \(sc\ 7.9.1\|b) \(sc\ 8.3.9.4
  1575. _
  1576. .T&
  1577. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1578.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.9.6
  1579. _
  1580. .T&
  1581. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1582. User data    nm    193                See reference    T{
  1583. \(sc\ 7.9.1\|c)
  1584. \(sc\ 8.3.9.5
  1585. m:
  1586. mandatory.
  1587. nm:
  1588. not mandatory (see \(sc\ 8.2.6).
  1589. .parag
  1590. T}
  1591. _
  1592. .TE
  1593. .nr PS 9
  1594. .RT
  1595. .ad r
  1596. \fBTable 19/X.225 [T19.225], p.\fR 
  1597. .sp 1P
  1598. .RT
  1599. .ad b
  1600. .RT
  1601. .LP
  1602. .sp 1
  1603. .bp
  1604. .PP
  1605. 8.3.9.3
  1606. The Transport Disconnect PV field shall indicate whether or
  1607. not the transport connection is to be kept, together with an optional reason
  1608. code. The encoding for this field shall be:
  1609. .LP
  1610.     a)
  1611.     bit\ 1\ =\ 0\ transport connection is kept;
  1612. .LP
  1613.     b)
  1614.     bit\ 1\ =\ 1\ transport connection is released;
  1615. .LP
  1616.     c)
  1617.     bit\ 2\ =\ 1\ user abort (see \(sc\ 8.3.9.5);
  1618. .LP
  1619.     d)
  1620.     bit\ 3\ =\ 1\ protocol error (see \(sc\ 8.3.9.4);
  1621. .LP
  1622.     e)
  1623.     bit\ 4\ =\ 1\ no reason;
  1624. .LP
  1625.     f
  1626. )
  1627.     bit\ 5\ =\ 1\ implementation restriction stated in the
  1628. PICS.
  1629. .LP
  1630.     Bits 6\(hy8 are reserved.
  1631. .PP
  1632. 8.3.9.4
  1633. The Reflect Parameter Values PV field shall only be present if
  1634. the Transport Disconnect PV field indicates protocol error and shall contain 
  1635. an implementation defined value and semantics. 
  1636. .PP
  1637. 8.3.9.5
  1638. The User Data PV field shall only be present if the Transport
  1639. Disconnect PV field indicates user abort and shall contain user data supplied 
  1640. by the SS\(hyuser. 
  1641. .PP
  1642. If this SPDU is to be sent on the transport expedited flow, the
  1643. length of the User Data parameter is limited to 9\ octets and the Enclosure 
  1644. Item shall not be present. If the SPDU is to be sent on the transport normal 
  1645. flow, the length of the User Data parameter is limited such that the total 
  1646. length 
  1647. (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  1648. .PP
  1649. 8.3.9.6
  1650. The Enclosure Item parameter, if present, shall be encoded as
  1651. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  1652. version\ 1 is selected.
  1653. .sp 2P
  1654. .LP
  1655. 8.3.10
  1656.     \fIABORT ACCEPT (AA) SPDU\fR 
  1657. .sp 1P
  1658. .RT
  1659. .sp 1P
  1660. .LP
  1661. 8.3.10.1\ \ The SI field shall contain the value 26.
  1662. .sp 9p
  1663. .RT
  1664. .LP
  1665. 8.3.10.2\ \ There is no parameter field associated with this SPDU.
  1666. .sp 2P
  1667. .LP
  1668. 8.3.11
  1669.     \fIDATA TRANSFER (DT) SPDU\fR 
  1670. .sp 1P
  1671. .RT
  1672. .sp 1P
  1673. .LP
  1674. 8.3.11.1\ \ The SI field shall contain the value 1.
  1675. .sp 9p
  1676. .RT
  1677. .LP
  1678. 8.3.11.2\ \ The parameter field shall be as specified in Table\ 20/X.225.
  1679. .ce
  1680. \fBH.T. [T20.225]\fR 
  1681. .ce
  1682. TABLE\ 20/X.225
  1683. .ce
  1684. \fBParameters of the DATA TRANSFER SPDU\fR 
  1685. .ps 9
  1686. .vs 11
  1687. .nr VS 11
  1688. .nr PS 9
  1689. .TS
  1690. center box;
  1691. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1692. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1693. _
  1694. .T&
  1695. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1696.             Enclosure item    nm    25    1\ octet    T{
  1697. \(sc\ 7.11.1\|a)
  1698. \(sc\ 8.3.10.3
  1699. T}
  1700. _
  1701. .T&
  1702. lw(132p) | lw(18p) | lw(18p) | cw(30p) | lw(30p) .
  1703. User information field            unlimited    T{
  1704. \(sc\ 7.11.1\|b)
  1705. \(sc\ 8.3.10.4
  1706. m:
  1707. mandatory.
  1708. nm:
  1709. not mandatory (see \(sc\ 8.2.6).
  1710. .parag
  1711. T}
  1712. _
  1713. .TE
  1714. .nr PS 9
  1715. .RT
  1716. .ad r
  1717. \fBTable 20/X.225 [T20.225], p.\fR 
  1718. .sp 1P
  1719. .RT
  1720. .ad b
  1721. .RT
  1722. .LP
  1723. 8.3.11.3\ \ The Enclosure Item PV field, if present, shall indicate whether or
  1724. not this SPDU is the beginning or end of the SSDU. This field shall be 
  1725. present if segmenting has been selected. This field shall not be present 
  1726. if segmenting has not been selected. The encoding for this field shall 
  1727. be: 
  1728. .LP
  1729.     a)
  1730.     bit\ 1\ =\ 1\ beginning of SSDU;
  1731. .LP
  1732.     bit\ 1\ =\ 0\ not beginning of SSDU;
  1733. .bp
  1734. .LP
  1735.     b)
  1736.     bit\ 2\ =\ 1\ end of SSDU;
  1737. .LP
  1738.     bit\ 2\ =\ 0\ not end of SSDU.
  1739. .LP
  1740.     Bits 3\(hy8 are reserved.
  1741. .PP
  1742. If this field is not present, the default shall be as though
  1743. bit\ 1\ =\ 1 and bit\ 2\ =\ 1 (i.e.\ beginning and end of SSDU).
  1744. .LP
  1745. 8.3.11.4\ \ The User Information Field, if present, shall contain user data
  1746. supplied by the SS\(hyuser. The User Information Field shall be present if the
  1747. Enclosure Item is not present, or has bit\ 2\ =\ 0.
  1748. .sp 2P
  1749. .LP
  1750. 8.3.12
  1751.     \fIEXPEDITED (EX) SPDU\fR 
  1752. .sp 1P
  1753. .RT
  1754. .sp 1P
  1755. .LP
  1756. 8.3.12.1\ \ The SI field shall contain the value 5.
  1757. .sp 9p
  1758. .RT
  1759. .LP
  1760. 8.3.12.2\ \ This SPDU contains only a User Information Field as specified in
  1761. Table\ 21/X.225.
  1762. .ce
  1763. \fBH.T. [T21.225]\fR 
  1764. .ce
  1765. TABLE\ 21/X.225
  1766. .ce
  1767. \fBParameters of the EXPEDITED SPDU\fR 
  1768. .ps 9
  1769. .vs 11
  1770. .nr VS 11
  1771. .nr PS 9
  1772. .TS
  1773. center box;
  1774. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1775. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1776. _
  1777. .T&
  1778. lw(132p) | lw(18p) | lw(18p) | cw(30p) | lw(30p) .
  1779. User information field            14\ octets  maximum    T{
  1780. \(sc\ 7.12.1
  1781. \(sc\ 8.3.12.3
  1782. m:
  1783. mandatory.
  1784. nm:
  1785. not mandatory (see \(sc\ 8.2.6).
  1786. .parag
  1787. T}
  1788. _
  1789. .TE
  1790. .nr PS 9
  1791. .RT
  1792. .ad r
  1793. \fBTable 21/X.225 [T21.225], p.\fR 
  1794. .sp 1P
  1795. .RT
  1796. .ad b
  1797. .RT
  1798. .LP
  1799. 8.3.12.3\ \ The User Information Field shall contain user data supplied by the
  1800. SS\(hyuser.
  1801. .sp 2P
  1802. .LP
  1803. 8.3.13
  1804.     \fITYPED DATA (TD) SPDU\fR 
  1805. .sp 1P
  1806. .RT
  1807. .sp 1P
  1808. .LP
  1809. 8.3.13.1\ \ The SI field shall contain the value 33.
  1810. .sp 9p
  1811. .RT
  1812. .LP
  1813. 8.3.13.2\ \ The parameter field shall be as specified in Table\ 22/X.225.
  1814. .ce
  1815. \fBH.T. [T22.225]\fR 
  1816. .ce
  1817. TABLE\ 22/X.225
  1818. .ce
  1819. \fBParameters of the TYPED DATA SPDU\fR 
  1820. .ps 9
  1821. .vs 11
  1822. .nr VS 11
  1823. .nr PS 9
  1824. .TS
  1825. center box;
  1826. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1827. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1828. _
  1829. .T&
  1830. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1831.             Enclosure item    nm    25    1\ octet    T{
  1832. \(sc\ 7.13.1\|a)
  1833. \(sc\ 8.3.13.3
  1834. T}
  1835. _
  1836. .T&
  1837. lw(132p) | lw(18p) | lw(18p) | cw(30p) | lw(30p) .
  1838. User information field            unlimited    T{
  1839. \(sc\ 7.13.1\|b)
  1840. \(sc\ 8.3.13.4
  1841. m:
  1842. mandatory.
  1843. nm:
  1844. not mandatory (see \(sc\ 8.2.6).
  1845. .parag
  1846. T}
  1847. _
  1848. .TE
  1849. .nr PS 9
  1850. .RT
  1851. .ad r
  1852. \fBTable 22/X.225 [T22.225], p.\fR 
  1853. .sp 1P
  1854. .RT
  1855. .ad b
  1856. .RT
  1857. .LP
  1858. .bp
  1859. .LP
  1860. 8.3.13.3\ \ The Enclosure Item PV field, if present, shall indicate whether or
  1861. not this SPDU is the beginning or end of the SSDU. This field shall be 
  1862. present if segmenting has been selected. This field shall not be present 
  1863. if segmenting has not been selected. The encoding for this field shall 
  1864. be: 
  1865. .LP
  1866.     a)
  1867.     bit\ 1\ =\ 1\ beginning of SSDU;
  1868. .LP
  1869.     bit\ 1\ =\ 0\ not beginning of SSDU;
  1870. .LP
  1871.     b)
  1872.     bit\ 2\ =\ 1\ end of SSDU;
  1873. .LP
  1874.     bit\ 2\ =\ 0\ not end of SSDU.
  1875. .LP
  1876.     Bits 3\(hy8 are reserved.
  1877. .PP
  1878. If this field is not present, the default shall be as though
  1879. bit\ 1\ =\ 1 and bit\ 2\ =\ 1 (i.e.\ beginning and end of SSDU).
  1880. .LP
  1881. 8.3.13.4\ \ The User Information Field, if present, shall contain user data
  1882. supplied by the SS\(hyuser. The User Information Field shall be present if the
  1883. Enclosure Item is not present, or has bit\ 2\ =\ 0.
  1884. .sp 2P
  1885. .LP
  1886. 8.3.14
  1887.     \fICAPABILITY DATA (CD) SPDU\fR 
  1888. .sp 1P
  1889. .RT
  1890. .sp 1P
  1891. .LP
  1892. 8.3.14.1\ \ The SI field shall contain the value 61.
  1893. .sp 9p
  1894. .RT
  1895. .LP
  1896. 8.3.14.2\ \ The parameter field shall be as specified in Table\ 23/X.225.
  1897. .LP
  1898. .sp 2
  1899. .ce
  1900. \fBH.T. [T23.225]\fR 
  1901. .ce
  1902. TABLE\ 23/X.225
  1903. .ce
  1904. \fBParameters of the CAPABILITY DATA SPDU\fR 
  1905. .ps 9
  1906. .vs 11
  1907. .nr VS 11
  1908. .nr PS 9
  1909. .TS
  1910. center box;
  1911. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1912. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1913. _
  1914. .T&
  1915. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1916.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.14.4
  1917. _
  1918. .T&
  1919. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1920. User data    nm    193                See reference    T{
  1921. \(sc\ 7.14.1
  1922. \(sc\ 8.3.14.3
  1923. m:
  1924. mandatory.
  1925. nm:
  1926. not mandatory (see \(sc\ 8.2.6).
  1927. .parag
  1928. T}
  1929. _
  1930. .TE
  1931. .nr PS 9
  1932. .RT
  1933. .ad r
  1934. \fBTable 23/X.225 [T23.225], p.\fR 
  1935. .sp 1P
  1936. .RT
  1937. .ad b
  1938. .RT
  1939. .LP
  1940. .sp 2
  1941. .LP
  1942. 8.3.14.3\ \ The User Data PV field, if present, shall contain user data
  1943. supplied by the SS\(hyuser.
  1944. .PP
  1945. The length of the User Data parameter is limited such that the
  1946. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  1947. .LP
  1948. 8.3.14.4\ \ The Enclosure Item parameter, if present, shall be encoded as
  1949. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  1950. version\ 1 is selected.
  1951. .sp 2P
  1952. .LP
  1953. 8.3.15
  1954.     \fICAPABILITY DATA ACK (CDA) SPDU\fR 
  1955. .sp 1P
  1956. .RT
  1957. .sp 1P
  1958. .LP
  1959. 8.3.15.1\ \ The SI field shall contain the value 62.
  1960. .sp 9p
  1961. .RT
  1962. .LP
  1963. 8.3.15.2\ \ The parameter field shall be as specified in Table\ 24/X.225.
  1964. .bp
  1965. .ce
  1966. \fBH.T. [T24.225]\fR 
  1967. .ce
  1968. TABLE\ 24/X.225
  1969. .ce
  1970. \fBParameters of the CAPABILITY DATA ACK SPDU\fR 
  1971. .ps 9
  1972. .vs 11
  1973. .nr VS 11
  1974. .nr PS 9
  1975. .TS
  1976. center box;
  1977. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  1978. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  1979. _
  1980. .T&
  1981. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1982.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.15.4
  1983. _
  1984. .T&
  1985. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  1986. User data    nm    193                See reference    T{
  1987. \(sc\ 7.15.1
  1988. \(sc\ 8.3.15.3
  1989. m:
  1990. mandatory.
  1991. nm:
  1992. not mandatory (see \(sc\ 8.2.6).
  1993. .parag
  1994. T}
  1995. _
  1996. .TE
  1997. .nr PS 9
  1998. .RT
  1999. .ad r
  2000. \fBTable 24/X.225 [T24.225], p.\fR 
  2001. .sp 1P
  2002. .RT
  2003. .ad b
  2004. .RT
  2005. .LP
  2006. 8.3.15.3\ \ The User Data PV field, if present, shall contain user data
  2007. supplied by the SS\(hyuser.
  2008. .PP
  2009. The length of the User Data parameter is limited such that the
  2010. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  2011. .LP
  2012. 8.3.15.4\ \ The Enclosure Item parameter, if present, shall be encoded as
  2013. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2014. version\ 1 is selected.
  2015. .sp 2P
  2016. .LP
  2017. 8.3.16
  2018.     \fIGIVE TOKENS (GT) SPDU\fR 
  2019. .sp 1P
  2020. .RT
  2021. .sp 1P
  2022. .LP
  2023. 8.3.16.1\ \ The SI field shall contain the value 1.
  2024. .sp 9p
  2025. .RT
  2026. .LP
  2027. 8.3.16.2\ \ The parameter field shall be as specified in Table\ 25/X.225.
  2028. .ce
  2029. \fBH.T. [T25.225]\fR 
  2030. .ce
  2031. TABLE\ 25/X.225
  2032. .ce
  2033. \fBParameters of the GIVE TOKENS SPDU\fR 
  2034. .ce
  2035. \fR 
  2036. .ps 9
  2037. .vs 11
  2038. .nr VS 11
  2039. .nr PS 9
  2040. .TS
  2041. center box;
  2042. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2043. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2044. _
  2045. .T&
  2046. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2047.             Token item    nm    16    1 octet    \(sc\ 7.16.1 \(sc\ 8.3.16.3
  2048. _
  2049. .T&
  2050. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2051.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.16.5
  2052. _
  2053. .T&
  2054. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2055. User data    nm    193                See reference    T{
  2056. \(sc\ 7.16.1\|b)
  2057. m:
  2058. mandatory.
  2059. nm:
  2060. not mandatory (see \(sc\ 8.2.6).
  2061. .parag
  2062. T}
  2063. _
  2064. .TE
  2065. .nr PS 9
  2066. .RT
  2067. .ad r
  2068. \fBTable 25/X.225 [T25.225], p.\fR 
  2069. .sp 1P
  2070. .RT
  2071. .ad b
  2072. .RT
  2073. .LP
  2074. 8.3.16.3\ \ The Token Item PV field, if present, shall indicate which tokens
  2075. are being given by the sending SS\(hyuser:
  2076. .LP
  2077.     a)
  2078.     bit\ 7\ =\ 1\ release token;
  2079. .LP
  2080.     b)
  2081.     bit\ 5\ =\ 1\ major/activity token;
  2082. .bp
  2083. .LP
  2084.     c)
  2085.     bit\ 3\ =\ 1\ synchronize\(hyminor token;
  2086. .LP
  2087.     d)
  2088.     bit\ 1\ =\ 1\ data token.
  2089. .LP
  2090.     Bits 2, 4, 6 and 8 are reserved.
  2091. .PP
  2092. Bits corresponding to tokens which are not available are ignored.
  2093. .PP
  2094. If this PV field is present, at least one bit corresponding to an
  2095. available token shall be set to one.
  2096. .RT
  2097. .LP
  2098. 8.3.16.4\ \ This SPDU may be used without the Token Item PI unit when
  2099. concatenated with Category\ 2 SPDUs according to Tables\ 7/X.225 and\ 8/X.225.
  2100. With some concatenations (see Tables\ 7/X.225 and\ 8/X.225) the Token Item PI
  2101. unit must be absent.
  2102. .LP
  2103. 8.3.16.5\ \ The Enclosure Item parameter, if present, shall be encoded as
  2104. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2105. version\ 1 is selected.
  2106. .LP
  2107. 8.3.16.6\ \ The User Data PV field, if present, shall contain user data 
  2108. supplied by the SS\(hyuser. This PGI unit shall only be present if the 
  2109. Token Item PI unit is present and shall not be present if protocol version\ 
  2110. 1 is selected. The 
  2111. length of the User Data parameter is limited such that the total length
  2112. (including SI and LI) does not exceed 65\|539\ octets.
  2113. .sp 2P
  2114. .LP
  2115. 8.3.17
  2116.     \fIPLEASE TOKENS (PT) SPDU\fR 
  2117. .sp 1P
  2118. .RT
  2119. .sp 1P
  2120. .LP
  2121. 8.3.17.1\ \ The SI field shall contain the value 2.
  2122. .sp 9p
  2123. .RT
  2124. .LP
  2125. 8.3.17.2\ \ The parameter fields shall be as specified in Table\ 26/X.225.
  2126. .ce
  2127. \fBH.T. [T26.225]\fR 
  2128. .ce
  2129. TABLE\ 26/X.225
  2130. .ce
  2131. \fBParameters of the PLEASE TOKENS SPDU\fR 
  2132. .ps 9
  2133. .vs 11
  2134. .nr VS 11
  2135. .nr PS 9
  2136. .TS
  2137. center box;
  2138. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2139. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2140. _
  2141. .T&
  2142. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2143.             Token item    nm    16    1\ octet    T{
  2144. \(sc\ 7.17.1.\|a)
  2145. \(sc\ 8.3.17.3
  2146. T}
  2147. _
  2148. .T&
  2149. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2150.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.17.6
  2151. _
  2152. .T&
  2153. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2154. User data    nm    193                See reference    T{
  2155. \(sc\ 7.17.1\|b)
  2156. \(sc\ 8.3.17.4
  2157. m:
  2158. mandatory.
  2159. nm:
  2160. not mandatory (see \(sc\ 8.2.6).
  2161. .parag
  2162. T}
  2163. _
  2164. .TE
  2165. .nr PS 9
  2166. .RT
  2167. .ad r
  2168. \fBTable 26/X.225 [T26.225], p.\fR 
  2169. .sp 1P
  2170. .RT
  2171. .ad b
  2172. .RT
  2173. .LP
  2174. 8.3.17.3\ \ The Token Item PV field, if present, shall indicate which tokens
  2175. are being requested by the sending SS\(hyuser:
  2176. .LP
  2177.     a)
  2178.     bit\ 7\ =\ 1\ release token;
  2179. .LP
  2180.     b)
  2181.     bit\ 5\ =\ 1\ major/activity token;
  2182. .LP
  2183.     c)
  2184.     bit\ 3\ =\ 1\ synchronize\(hyminor token;
  2185. .LP
  2186.     d)
  2187.     bit\ 1\ =\ 1\ data token.
  2188. .LP
  2189.     Bits 2, 4, 6 and 8 are reserved.
  2190. .PP
  2191. Bits corresponding to tokens which are not available are ignored.
  2192. .PP
  2193. If this PV field is present, at least one bit corresponding to an
  2194. available token shall be set to one.
  2195. .bp
  2196. .RT
  2197. .LP
  2198. 8.3.17.4\ \ The User Data PV field, if present, shall contain user data
  2199. supplied by the SS\(hyuser. This PGI unit shall only be present if the 
  2200. Token Item PI unit is present. 
  2201. .PP
  2202. The length of the User Data parameter is limited such that the
  2203. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  2204. .LP
  2205. 8.3.17.5\ \ This SPDU may be used without the Token Item PI unit and the User
  2206. Data PGI unit when concatenated with Category\ 2 SPDUs according to
  2207. Tables\ 7/X.225 and\ 8/X.225. In this case, the SPDU does not achieve any 
  2208. Please Token function. 
  2209. .LP
  2210. 8.3.17.6\ \ The Enclosure Item parameter, if present, shall be encoded as
  2211. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2212. version\ 1 is selected.
  2213. .sp 2P
  2214. .LP
  2215. 8.3.18
  2216.     \fIGIVE TOKENS CONFIRM (GTC) SPDU\fR 
  2217. .sp 1P
  2218. .RT
  2219. .sp 1P
  2220. .LP
  2221. 8.3.18.1\ \ The SI field shall contain the value 21.
  2222. .sp 9p
  2223. .RT
  2224. .LP
  2225. 8.3.18.2\ \ The parameter fields shall be as specified in Table 27/X.225.
  2226. .ce
  2227. \fBH.T. [T27.225]\fR 
  2228. .ce
  2229. TABLE\ 27/X.225
  2230. .ce
  2231. \fBParameters of the GIVE TOKENS CONFIRM SPDU 
  2232. .ps 9
  2233. .vs 11
  2234. .nr VS 11
  2235. .nr PS 9
  2236. .TS
  2237. center box;
  2238. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2239. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2240. _
  2241. .T&
  2242. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2243.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.18.3
  2244. _
  2245. .T&
  2246. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2247. User data    nm    193                See reference    T{
  2248. \(sc\ 7.18.1
  2249. \(sc\ 8.3.18.4
  2250. m:
  2251. mandatory.
  2252. nm:
  2253. not mandatory (see \(sc\ 8.2.6).
  2254. .parag
  2255. T}
  2256. _
  2257. .TE
  2258. .nr PS 9
  2259. .RT
  2260. .ad r
  2261. \fBTable 27/X.225 [T27.225], p.\fR 
  2262. .sp 1P
  2263. .RT
  2264. .ad b
  2265. .RT
  2266. .LP
  2267. 8.3.18.3\ \ The Enclosure Item parameter, if present, shall be encoded as
  2268. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2269. version\ 1 is selected.
  2270. .LP
  2271. 8.3.18.4\ \ The User Data PV field, if present, shall contain user data
  2272. supplied by the SS\(hyuser. This PGI unit shall not be present if protocol
  2273. version\ 1
  2274. is selected. The length of the User Data parameter is limited such that the
  2275. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  2276. .sp 2P
  2277. .LP
  2278. 8.3.19
  2279.     \fIGIVE TOKENS ACK (GTA) SPDU\fR 
  2280. .sp 1P
  2281. .RT
  2282. .sp 1P
  2283. .LP
  2284. 8.3.19.1\ \ The SI field shall contain the value 22.
  2285. .sp 9p
  2286. .RT
  2287. .LP
  2288. 8.3.19.2\ \ There is no parameter field associated with this SPDU.
  2289. .sp 2P
  2290. .LP
  2291. 8.3.20
  2292.     \fIMINOR SYNC POINT (MIP) SPDU\fR 
  2293. .sp 1P
  2294. .RT
  2295. .sp 1P
  2296. .LP
  2297. 8.3.20.1\ \ The SI field shall contain the value 49.
  2298. .sp 9p
  2299. .RT
  2300. .LP
  2301. 8.3.20.2\ \ The parameter fields shall be as specified in Table\ 28/X.225.
  2302. .bp
  2303. .ce
  2304. \fBH.T. [T28.225]\fR 
  2305. .ce
  2306. TABLE\ 28/X.225
  2307. .ce
  2308. \fBParameters of the MINOR SYNC POINT SPDU\fR 
  2309. .ce
  2310. \fR 
  2311. .ps 9
  2312. .vs 11
  2313. .nr VS 11
  2314. .nr PS 9
  2315. .TS
  2316. center box;
  2317. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2318. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2319. _
  2320. .T&
  2321. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2322.             Sync type item    nm    15    1\ octet    T{
  2323. \(sc\ 7.20.1\|a)
  2324. \(sc\ 8.3.20.3
  2325. T}
  2326. _
  2327. .T&
  2328. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2329.             Serial number    m    42    6\ octets  maximum    T{
  2330. \(sc\ 7.20.1\|b)
  2331. \(sc\ 8.3.20.4
  2332. T}
  2333. _
  2334. .T&
  2335. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2336.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.20.6
  2337. _
  2338. .T&
  2339. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2340. User data    nm    193                See reference    T{
  2341. \(sc\ 7.20.1\|c)
  2342. \(sc\ 8.3.20.5
  2343. m:
  2344. mandatory.
  2345. nm:
  2346. not mandatory (see \(sc\ 8.2.6).
  2347. .parag
  2348. T}
  2349. _
  2350. .TE
  2351. .nr PS 9
  2352. .RT
  2353. .ad r
  2354. \fBTable 28/X.225 [T28.225], p.\fR 
  2355. .sp 1P
  2356. .RT
  2357. .ad b
  2358. .RT
  2359. .LP
  2360. 8.3.20.3\ \ The Sync Type Item PV field, if present, shall indicate that an
  2361. explicit confirmation is not required:
  2362. .LP
  2363.     bit\ 1\ =\ 1\ explicit confirmation not required.
  2364. .LP
  2365.     Bits 2\(hy8 are reserved.
  2366. .PP
  2367. This parameter field shall be absent if an explicit confirmation   is required.
  2368. .LP
  2369. 8.3.20.4\ \ The Serial Number PV field shall be coded as specified in
  2370. \(sc\ 8.3.1.10.
  2371. .LP
  2372. 8.3.20.5\ \ The User Data PV field, if present, shall contain user data
  2373. supplied by the SS\(hyuser.
  2374. .PP
  2375. The length of the User Data parameter is limited such that the
  2376. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  2377. .LP
  2378. 8.3.20.6\ \ The Enclosure Item parameter, if present, shall be encoded as
  2379. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2380. version\ 1 is selected.
  2381. .sp 2P
  2382. .LP
  2383. 8.3.21
  2384.     \fIMINOR SYNC (MIA) SPDU\fR 
  2385. .sp 1P
  2386. .RT
  2387. .sp 1P
  2388. .LP
  2389. 8.3.21.1\ \ The SI field shall contain the value 50.
  2390. .sp 9p
  2391. .RT
  2392. .LP
  2393. 8.3.21.2\ \ The parameter fields shall be as specified in Table\ 29/X.225.
  2394. .ce
  2395. \fBH.T. [T29.225]\fR 
  2396. .ce
  2397. TABLE\ 29/X.225
  2398. .ce
  2399. \fBParameters of the MINOR SYNC ACK SPDU\fR 
  2400. .ce
  2401. \fR 
  2402. .ps 9
  2403. .vs 11
  2404. .nr VS 11
  2405. .nr PS 9
  2406. .TS
  2407. center box;
  2408. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2409. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2410. _
  2411. .T&
  2412. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2413.             Serial number    m    42    6\ octets  maximum    T{
  2414. \(sc\ 7.21.1\|a)
  2415. \(sc\ 8.3.21.3
  2416. T}
  2417. _
  2418. .T&
  2419. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2420.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.21.5
  2421. _
  2422. .T&
  2423. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2424.             User data    nm    46    See reference    T{
  2425. \(sc\ 7.21.1\|b)
  2426. \(sc\ 8.3.21.4
  2427. m:
  2428. mandatory.
  2429. nm:
  2430. not mandatory (see \(sc\ 8.2.6).
  2431. .parag
  2432. T}
  2433. _
  2434. .TE
  2435. .nr PS 9
  2436. .RT
  2437. .ad r
  2438. \fBTable 29/X.225 [T29.225], p.\fR 
  2439. .sp 1P
  2440. .RT
  2441. .ad b
  2442. .RT
  2443. .LP
  2444. .bp
  2445. .LP
  2446. 8.3.21.3\ \ The Serial Number PV field shall be coded as specified in
  2447. \(sc\ 8.3.1.10.
  2448. .LP
  2449. 8.3.21.4\ \ The User Data PV field, if present, shall contain user data
  2450. supplied by the SS\(hyuser.
  2451. .PP
  2452. The length of the User Data parameter is limited such that the
  2453. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  2454. .LP
  2455. 8.3.21.5\ \ The Enclosure Item parameter, if present, shall be encoded as
  2456. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2457. version\ 1 is selected.
  2458. .sp 2P
  2459. .LP
  2460. 8.3.22
  2461.     \fIMAJOR SYNC POINT (MAP) SPDU\fR 
  2462. .sp 1P
  2463. .RT
  2464. .sp 1P
  2465. .LP
  2466. 8.3.22.1\ \ The SI field shall contain the value 41. This is the same value
  2467. as the SI field for the ACTIVITY END SPDU (see \(sc\ 8.3.35).
  2468. .sp 9p
  2469. .RT
  2470. .LP
  2471. 8.3.22.2\ \ The parameter fields shall be as specified in Table\ 30/X.225.
  2472. .ce
  2473. \fBH.T. [T30.225]\fR 
  2474. .ce
  2475. TABLE\ 30/X.225
  2476. .ce
  2477. \fBParameters of the MAJOR SYNC POINT SPDU\fR 
  2478. .ce
  2479. \fR 
  2480. .ps 9
  2481. .vs 11
  2482. .nr VS 11
  2483. .nr PS 9
  2484. .TS
  2485. center box;
  2486. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2487. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2488. _
  2489. .T&
  2490. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2491.             Sync type item    m    15    1\ octet    T{
  2492. \(sc\ 7.22.1\|a)
  2493. \(sc\ 8.3.22.3
  2494. T}
  2495. _
  2496. .T&
  2497. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2498.             Serial number    m    42    6\ octets  maximum    T{
  2499. \(sc\ 7.22.1\|b)
  2500. \(sc\ 8.3.22.4
  2501. T}
  2502. _
  2503. .T&
  2504. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2505.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.22.6
  2506. _
  2507. .T&
  2508. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2509. User data    nm    193                See reference    T{
  2510. \(sc\ 7.22.1\|c)
  2511. \(sc\ 8.3.22.5
  2512. m:
  2513. mandatory.
  2514. nm:
  2515. not mandatory (see \(sc\ 8.2.6).
  2516. .parag
  2517. T}
  2518. _
  2519. .TE
  2520. .nr PS 9
  2521. .RT
  2522. .ad r
  2523. \fBTable 30/X.225 [T30.225], p.\fR 
  2524. .sp 1P
  2525. .RT
  2526. .ad b
  2527. .RT
  2528. .LP
  2529. 8.3.22.3\ \ The Sync Type Item PV field shall indicate that this is not the
  2530. end of an activity:
  2531. .LP
  2532.     bit\ 1\ =\ 1\ major synchronization point without end of activity.
  2533. .LP
  2534.     Bits 2\(hy8 are reserved.
  2535. .LP
  2536. 8.3.22.4\ \ The Serial Number PV field shall be coded as specified in
  2537. \(sc\ 8.3.1.10.
  2538. .LP
  2539. 8.3.22.5\ \ The User Data PV field, if present, shall contain user data
  2540. supplied by the SS\(hyuser.
  2541. .PP
  2542. The length of the User Data parameter is limited such that the
  2543. total length (including SI and LI) of the SPDU does not exceed 65\|539\ octets.
  2544. .LP
  2545. 8.3.22.6\ \ The Enclosure Item parameter, if present, shall be encoded as
  2546. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2547. version\ 1 is selected.
  2548. .sp 2P
  2549. .LP
  2550. 8.3.23
  2551.     \fIMAJOR SYNC ACK (MAA) SPDU\fR 
  2552. .sp 1P
  2553. .RT
  2554. .sp 1P
  2555. .LP
  2556. 8.3.23.1\ \ The SI field shall contain the value 42.
  2557. .sp 9p
  2558. .RT
  2559. .LP
  2560. 8.3.23.2\ \ The parameter fields shall be as specified in Table\ 31/X.225.
  2561. .bp
  2562. .ce
  2563. \fBH.T. [T31.225]\fR 
  2564. .ce
  2565. TABLE\ 31/X.225
  2566. .ce
  2567. \fBParameters of the MAJOR SYNC ACK SPDU\fR 
  2568. .ce
  2569. \fR 
  2570. .ce
  2571. \fR 
  2572. .ps 9
  2573. .vs 11
  2574. .nr VS 11
  2575. .nr PS 9
  2576. .TS
  2577. center box;
  2578. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2579. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2580. _
  2581. .T&
  2582. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2583.             Serial number    m    42    6\ octets  maximum    T{
  2584. \(sc\ 7.23.1\|a)
  2585. \(sc\ 8.3.23.3
  2586. T}
  2587. _
  2588. .T&
  2589. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2590.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.23.5
  2591. _
  2592. .T&
  2593. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2594. User data    nm    193                See reference    T{
  2595. \(sc\ 7.23.1\|b)
  2596. \(sc\ 8.3.23.4
  2597. m:
  2598. mandatory.
  2599. nm:
  2600. not mandatory (see \(sc\ 8.2.6).
  2601. .parag
  2602. T}
  2603. _
  2604. .TE
  2605. .nr PS 9
  2606. .RT
  2607. .ad r
  2608. \fBTable 31/X.225 [T31.225], p.\fR 
  2609. .sp 1P
  2610. .RT
  2611. .ad b
  2612. .RT
  2613. .LP
  2614. 8.3.23.3\ \ The Serial Number PV field shall be coded as specified in
  2615. \(sc\ 8.3.1.10.
  2616. .LP
  2617. 8.3.23.4\ \ The User Data PV field, if present, shall contain user data
  2618. supplied by the SS\(hyuser.
  2619. .PP
  2620. \fINote\fR \ \(em\ This SPDU is identical to the ACTIVITY END ACK SPDU
  2621. (see \(sc\ 8.3.36).
  2622. .PP
  2623. The length of the User Data parameter is limited such that the
  2624. total length (including SI and LI) of the SPDU does not exceed
  2625. 65\|539\ octets.
  2626. .RT
  2627. .LP
  2628. 8.3.23.5\ \ The Enclosure Item parameter, if present, shall be encoded as
  2629. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2630. version\ 1 is selected.
  2631. .sp 2P
  2632. .LP
  2633. 8.3.24
  2634.     \fIRESYNCHRONIZE (RS) SPDU\fR 
  2635. .sp 1P
  2636. .RT
  2637. .sp 1P
  2638. .LP
  2639. 8.3.24.1\ \ The SI field shall contain the value 53.
  2640. .sp 9p
  2641. .RT
  2642. .LP
  2643. 8.3.24.2\ \ The parameter fields shall be as specified in Table\ 32/X.245.
  2644. .LP
  2645. 8.3.24.3\ \ The Token Setting Item PV field indicates the requesting SS\(hyuser's 
  2646. proposed settings for each available token. The bits of the Token Setting 
  2647. Item PV field are defined as bit pairs: 
  2648. .LP
  2649.     a)
  2650.     bits\ 8,\ 7\ release token;
  2651. .LP
  2652.     b)
  2653.     bits\ 6,\ 5\ major/activity token;
  2654. .LP
  2655.     c)
  2656.     bits\ 4,\ 3\ synchronize\(hyminor token;
  2657. .LP
  2658.     d)
  2659.     bits\ 2,\ 1\ data token.
  2660. .PP
  2661. The encoding for each bit pair shall be:
  2662. .LP
  2663.     e)
  2664.     00\ :\ requestor's side;
  2665. .LP
  2666.     f
  2667. )
  2668.     01\ :\ acceptor's side;
  2669. .LP
  2670.     g)
  2671.     10\ :\ accepting SS\(hyuser's choice;
  2672. .LP
  2673.     h)
  2674.     11\ :\ reserved.
  2675. .PP
  2676. The values are relevant only if the appropriate token is
  2677. available. If no token is available, this parameter need not be present.
  2678. .bp
  2679. .ce
  2680. \fBH.T. [T32.225]\fR 
  2681. .ce
  2682. TABLE\ 32/X.225
  2683. .ce
  2684. \fBParameters of the RESYNCHRONIZE SPDU\fR 
  2685. .ps 9
  2686. .vs 11
  2687. .nr VS 11
  2688. .nr PS 9
  2689. .TS
  2690. center box;
  2691. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2692. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2693. _
  2694. .T&
  2695. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2696.             Token setting item    nm    26    1\ octet    T{
  2697. \(sc\ 7.24.1\|a)
  2698. \(sc\ 8.3.24.3
  2699. T}
  2700. _
  2701. .T&
  2702. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2703.             Resync type    m    27    1\ octet    T{
  2704. \(sc\ 7.24.1\|b)
  2705. \(sc\ 8.3.24.4
  2706. T}
  2707. _
  2708. .T&
  2709. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2710.             Serial number    m    42    6\ octets  maximum    T{
  2711. \(sc\ 7.24.1\|c)
  2712. \(sc\ 8.3.24.5
  2713. T}
  2714. _
  2715. .T&
  2716. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2717.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.24.7
  2718. _
  2719. .T&
  2720. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2721. User data    nm    193                See reference    T{
  2722. \(sc\ 7.24.1\|d)
  2723. \(sc\ 8.3.24.6
  2724. m:
  2725. mandatory.
  2726. nm:
  2727. not mandatory (see \(sc\ 8.2.6).
  2728. .parag
  2729. T}
  2730. _
  2731. .TE
  2732. .nr PS 9
  2733. .RT
  2734. .ad r
  2735. \fBtableau 32/X.225 [T32.225], p. 25\fR 
  2736. .sp 1P
  2737. .RT
  2738. .ad b
  2739. .RT
  2740. .LP
  2741. .sp 2
  2742. .LP
  2743. 8.3.24.4\ \ The Resync Type PV field indicates the resynchronize type which
  2744. is required:
  2745. .LP
  2746.     a)
  2747.     0\ :\ resynchronize restart;
  2748. .LP
  2749.     b)
  2750.     1\ :\ resynchronize abandon;
  2751. .LP
  2752.     c)
  2753.     2\ :\ resynchronize set.
  2754. .PP
  2755. All other values are reserved.
  2756. .LP
  2757. 8.3.24.5\ \ The Serial Number PV field shall be encoded as specified in
  2758. \(sc\ 8.3.1.10.
  2759. .LP
  2760. 8.3.24.6\ \ The User Data PV field, if present, shall contain user data
  2761. supplied by the SS\(hyuser.
  2762. .PP
  2763. The length of the User Data parameter is limited such that the
  2764. total length (including SI and LI) of the SPDU does not exceed
  2765. 65\|539\ octets.
  2766. .LP
  2767. 8.3.24.7\ \ The Enclosure Item parameter, if present, shall be encoded as
  2768. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2769. version\ 1 is selected.
  2770. .sp 2P
  2771. .LP
  2772. 8.3.25
  2773.     \fIRESYNCHRONIZE ACK (RA) SPDU\fR 
  2774. .sp 1P
  2775. .RT
  2776. .sp 1P
  2777. .LP
  2778. 8.3.25.1\ \ The SI field shall contain the value 34.
  2779. .sp 9p
  2780. .RT
  2781. .LP
  2782. 8.3.25.2\ \ The parameter fields shall be as specified in Table\ 33/X.245.
  2783. .bp
  2784. .ce
  2785. \fBH.T. [T33.225]\fR 
  2786. .ce
  2787. TABLE\ 33/X.225
  2788. .ce
  2789. \fBParameters of the RESYNCHRONIZE ACK SPDU\fR 
  2790. .ps 9
  2791. .vs 11
  2792. .nr VS 11
  2793. .nr PS 9
  2794. .TS
  2795. center box;
  2796. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2797. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2798. _
  2799. .T&
  2800. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2801.             Token setting item    nm    26    1\ octet    T{
  2802. \(sc\ 7.25.1\|a)
  2803. \(sc\ 8.3.25.3
  2804. T}
  2805. _
  2806. .T&
  2807. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2808.             Serial number    m    42    6\ octets  maximum    T{
  2809. \(sc\ 7.25.1\|b)
  2810. \(sc\ 8.3.25.4
  2811. T}
  2812. _
  2813. .T&
  2814. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2815.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.25.6
  2816. _
  2817. .T&
  2818. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2819. User data    nm    193                See reference    T{
  2820. \(sc\ 7.25.1\|c)
  2821. \(sc\ 8.3.25.5
  2822. m:
  2823. mandatory.
  2824. nm:
  2825. not mandatory (see \(sc\ 8.2.6).
  2826. .parag
  2827. T}
  2828. _
  2829. .TE
  2830. .nr PS 9
  2831. .RT
  2832. .ad r
  2833. \fBTable 33/X.225 [T33.225], p.\fR 
  2834. .sp 1P
  2835. .RT
  2836. .ad b
  2837. .RT
  2838. .LP
  2839. 8.3.25.3\ \ The Token Setting Item PV field indicates token settings for each
  2840. token available on the session connection. The bits and encoding are defined 
  2841. in \(sc\ 8.3.24.3. For the case where the requesting SS\(hyuser has indicated 
  2842. that the 
  2843. assignment is the accepting SS\(hyuser's choice, the field shall contain the
  2844. values chosen by the accepting SS\(hyuser. Otherwise, the values in the
  2845. RESYNCHRONIZE SPDU must be returned.
  2846. .PP
  2847. This parameter need not be present if no tokens are available.
  2848. .LP
  2849. 8.3.25.4\ \ The Serial Number PV field shall be coded as specified in
  2850. \(sc\ 8.3.1.10.
  2851. .LP
  2852. 8.3.25.5\ \ The User Data PV field, if present, shall contain user data
  2853. supplied by the SS\(hyuser.
  2854. .PP
  2855. The length of the User Data parameter is limited such that the
  2856. total length (including SI and LI) of the SPDU does not exceed
  2857. 65\|539\ octets.
  2858. .LP
  2859. 8.3.25.6\ \ The Enclosure Item parameter, if present, shall be encoded as
  2860. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  2861. version\ 1 is selected.
  2862. .sp 2P
  2863. .LP
  2864. 8.3.26
  2865.     \fIPREPARE (PR) SPDU\fR 
  2866. .sp 1P
  2867. .RT
  2868. .sp 1P
  2869. .LP
  2870. 8.3.26.1\ \ The SI field shall contain the value 7.
  2871. .sp 9p
  2872. .RT
  2873. .LP
  2874. 8.3.26.2\ \ The parameter field shall be as specified in Table\ 34/X.225.
  2875. .ce
  2876. \fBH.T. [T34.225]\fR 
  2877. .ce
  2878. TABLE\ 34/X.225
  2879. .ce
  2880. \fBParameters of the PREPARE SPDU\fR 
  2881. .ps 9
  2882. .vs 11
  2883. .nr VS 11
  2884. .nr PS 9
  2885. .TS
  2886. center box;
  2887. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2888. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2889. _
  2890. .T&
  2891. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2892.             Prepare type    m    24    1\ octet    T{
  2893. \(sc\ 7.26.1
  2894. \(sc\ 8.3.26.3
  2895. m:
  2896. mandatory.
  2897. nm:
  2898. not mandatory (see \(sc 8.2.6).
  2899. .parag
  2900. T}
  2901. _
  2902. .TE
  2903. .nr PS 9
  2904. .RT
  2905. .ad r
  2906. \fBTable 34/X.225 [T34.225], p.\fR 
  2907. .sp 1P
  2908. .RT
  2909. .ad b
  2910. .RT
  2911. .LP
  2912. .bp
  2913. .LP
  2914. 8.3.26.3\ \ The Prepare Type PV field indicates which SPDU should be expected
  2915. on the transport normal flow. The value for this field shall be:
  2916. .LP
  2917.     a)
  2918.     1\ Prepare for MAJOR SYNC ACK SPDU;
  2919. .LP
  2920.     b)
  2921.     2\ Prepare for RESYNCHRONIZE SPDU;
  2922. .LP
  2923.     c)
  2924.     3\ Prepare for RESYNCHRONIZE ACK SPDU;
  2925. .LP
  2926.     d)
  2927.     4\ Prepare for ABORT SPDU.
  2928. .PP
  2929. All other values are reserved and shall not be used.
  2930. .sp 2P
  2931. .LP
  2932. 8.3.27
  2933.     \fIEXCEPTION REPORT (ER) SPDU\fR 
  2934. .sp 1P
  2935. .RT
  2936. .sp 1P
  2937. .LP
  2938. 8.3.27.1\ \ The SI field shall contain the value 0.
  2939. .sp 9p
  2940. .RT
  2941. .LP
  2942. 8.3.27.2\ \ The parameter field shall be as specified in Table\ 35/X.225.
  2943. .ce
  2944. \fBH.T. [T35.225]\fR 
  2945. .ce
  2946. TABLE\ 35/X.225
  2947. .ce
  2948. \fBParameters of the EXCEPTION REPORT SPDU\fR 
  2949. .ps 9
  2950. .vs 11
  2951. .nr VS 11
  2952. .nr PS 9
  2953. .TS
  2954. center box;
  2955. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  2956. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  2957. _
  2958. .T&
  2959. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  2960.             Reflect parameter values    m    49    65\|531\ octets  maximum    T{
  2961. \(sc\ 7.27.1
  2962. \(sc\ 8.3.27.3
  2963. m:
  2964. mandatory.
  2965. nm:
  2966. not mandatory (see \(sc\ 8.2.6).
  2967. .parag
  2968. T}
  2969. _
  2970. .TE
  2971. .nr PS 9
  2972. .RT
  2973. .ad r
  2974. \fBTable 35/X.225 [T35.225], p.\fR 
  2975. .sp 1P
  2976. .RT
  2977. .ad b
  2978. .RT
  2979. .LP
  2980. 8.3.27.3\ \ The Reflect Parameter Values PV field shall contain the bit
  2981. pattern of the SPDU in error, up to and including the detected error, to a
  2982. maximum of \fIn\fR octets,
  2983. \v'6p'
  2984. .sp 1P
  2985. .ce 1000
  2986. where 1024 \(= \fIn\fR \(= 65\|531
  2987. .ce 0
  2988. .sp 1P
  2989. .PP
  2990. .sp 1
  2991. \fINote\fR \ \(em\ Not all implementations may be able to deal with field
  2992. lengths greater than\ 1024. It is recommended that, whenever possible, the
  2993. Reflect Parameters PV field should contain the bit pattern of the SPDU in
  2994. error up to and including the detected error.
  2995. .sp 2P
  2996. .LP
  2997. 8.3.28
  2998.     \fIEXCEPTION DATA (ED) SPDU\fR 
  2999. .sp 1P
  3000. .RT
  3001. .sp 1P
  3002. .LP
  3003. 8.3.28.1\ \ The SI field shall contain the value 48.
  3004. .sp 9p
  3005. .RT
  3006. .LP
  3007. 8.3.28.2\ \ The parameter fields shall be as specified in Table\ 36/X.225.
  3008. .LP
  3009. 8.3.28.3\ \ The Reason Code PV field shall contain one of the following
  3010. values:
  3011. .LP
  3012.     a)
  3013.     \ \ 0\ No specific reason stated;
  3014. .LP
  3015.     b)
  3016.     \ \ 1\ Temporarily unable to continue;
  3017. .LP
  3018.     c)
  3019.     \ \ 2\ Reserved;
  3020. .LP
  3021.     d)
  3022.     \ \ 3\ User sequence error;
  3023. .LP
  3024.     e)
  3025.     \ \ 4\ Reserved;
  3026. .LP
  3027.     f
  3028. )
  3029.     \ \ 5\ Local SS\(hyuser error;
  3030. .LP
  3031.     g)
  3032.     \ \ 6\ Unrecoverable procedural error;
  3033. .LP
  3034.     h)
  3035.     128\ Demand data token.
  3036. .PP
  3037. All other values are reserved and shall not be used.
  3038. .bp
  3039. .ce
  3040. \fBH.T. [T36.225]\fR 
  3041. .ce
  3042. TABLE\ 36/X.225
  3043. .ce
  3044. \fBParameters of the EXCEPTION DATA SPDU\fR 
  3045. .ps 9
  3046. .vs 11
  3047. .nr VS 11
  3048. .nr PS 9
  3049. .TS
  3050. center box;
  3051. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3052. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3053. _
  3054. .T&
  3055. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3056.             Reason code    m    50    1\ octet    T{
  3057. \(sc\ 7.28.1\|a)
  3058. \(sc\ 8.3.25.3
  3059. T}
  3060. _
  3061. .T&
  3062. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3063.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.28.5
  3064. _
  3065. .T&
  3066. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3067. User data    nm    193                See reference    T{
  3068. \(sc\ 7.28.1\|b)
  3069. \(sc\ 8.3.28.4
  3070. m:
  3071. mandatory.
  3072. nm:
  3073. not mandatory (see \(sc\ 8.2.6).
  3074. .parag
  3075. T}
  3076. _
  3077. .TE
  3078. .nr PS 9
  3079. .RT
  3080. .ad r
  3081. \fBtableau 36/X.225 [T36.225], p. 29\fR 
  3082. .sp 1P
  3083. .RT
  3084. .ad b
  3085. .RT
  3086. .LP
  3087. 8.3.28.4\ \ The User Data PV field, if present, shall contain user data
  3088. supplied by the SS\(hyuser.
  3089. .PP
  3090. The length of the User Data parameter is limited such that the
  3091. total length (including SI and LI) of the SPDU does not exceed
  3092. 65\|539\ octets.
  3093. .LP
  3094. 8.3.28.5\ \ The Enclosure Item parameter, if present, shall be encoded as
  3095. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3096. version\ 1 is selected.
  3097. .sp 2P
  3098. .LP
  3099. 8.3.29
  3100.     \fIACTIVITY START (AS) SPDU\fR 
  3101. .sp 1P
  3102. .RT
  3103. .sp 1P
  3104. .LP
  3105. 8.3.29.1\ \ The SI field shall contain the value 45.
  3106. .sp 9p
  3107. .RT
  3108. .LP
  3109. 8.3.29.2\ \ The parameter fields shall be as specified in Table\ 37/X.225.
  3110. .ce
  3111. \fBH.T. [T37.225]\fR 
  3112. .ce
  3113. TABLE\ 37/X.225
  3114. .ce
  3115. \fBParameters of the ACTIVITY START SPDU\fR 
  3116. .ps 9
  3117. .vs 11
  3118. .nr VS 11
  3119. .nr PS 9
  3120. .TS
  3121. center box;
  3122. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3123. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3124. _
  3125. .T&
  3126. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3127.             Activity identifier    m    41    6\ octets  maximum    T{
  3128. \(sc\ 7.29.1\|a)
  3129. \(sc\ 8.3.29.3
  3130. T}
  3131. _
  3132. .T&
  3133. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3134.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.29.5
  3135. _
  3136. .T&
  3137. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3138. User data    nm    193                See reference    T{
  3139. \(sc\ 7.29.1\|b)
  3140. \(sc\ 8.3.29.4
  3141. m:
  3142. mandatory.
  3143. nm:
  3144. not mandatory (see \(sc\ 8.2.6).
  3145. .parag
  3146. T}
  3147. _
  3148. .TE
  3149. .nr PS 9
  3150. .RT
  3151. .ad r
  3152. \fBTable 37/X.225 [T37.225], p.\fR 
  3153. .sp 1P
  3154. .RT
  3155. .ad b
  3156. .RT
  3157. .LP
  3158. 8.3.29.3\ \ The Activity Identifier PV field shall be as defined by the
  3159. sending SS\(hyuser.
  3160. .LP
  3161. 8.3.29.4\ \ The User Data PV field, if present, shall contain user data
  3162. supplied by the SS\(hyuser.
  3163. .PP
  3164. The length of the User Data parameter is limited such that the
  3165. total length (including SI and LI) of the SPDU does not exceed
  3166. 65\|539\ octets.
  3167. .bp
  3168. .LP
  3169. 8.3.29.5\ \ The Enclosure Item parameter, if present, shall be encoded as
  3170. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3171. version\ 1 is selected.
  3172. .sp 2P
  3173. .LP
  3174. 8.3.30
  3175.     \fIACTIVITY RESUME (AR) SPDU\fR 
  3176. .sp 1P
  3177. .RT
  3178. .sp 1P
  3179. .LP
  3180. 8.3.30.1\ \ The SI field shall contain the value 29.
  3181. .sp 9p
  3182. .RT
  3183. .LP
  3184. 8.3.30.2\ \ The parameter fields shall be as specified in Table\ 38/X.225.
  3185. .LP
  3186. 8.3.30.3\ \ The Called SS\(hyuser Reference PV field shall be as defined by the
  3187. sending SS\(hyuser.
  3188. .LP
  3189. 8.3.30.4\ \ The Calling SS\(hyuser Reference PV field shall be as defined 
  3190. by the 
  3191. sending SS\(hyuser.
  3192. .LP
  3193. 8.3.30.5\ \ The Common Reference PV field shall be as defined by the sending
  3194. SS\(hyuser.
  3195. .LP
  3196. 8.3.30.6\ \ The Additional Reference Information PV field shall be as defined
  3197. by the sending SS\(hyuser.
  3198. .LP
  3199. 8.3.30.7\ \ The Old Activity Identifier PV field shall be as defined by the
  3200. sending SS\(hyuser.
  3201. .ce
  3202. \fBH.T. [T38.225]\fR 
  3203. .ce
  3204. TABLE\ 38/X.225
  3205. .ce
  3206. \fBParameters of the ACTIVITY RESUME SPDU\fR 
  3207. .ps 9
  3208. .vs 11
  3209. .nr VS 11
  3210. .nr PS 9
  3211. .TS
  3212. center box;
  3213. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3214. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3215. _
  3216. .T&
  3217. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) , ^  | ^  | ^  | l | c | c | c | l 
  3218. ^  | ^  | ^  | l | c | c | c | l 
  3219. ^  | ^  | ^  | l | c | c | c | l 
  3220. ^  | ^  | ^  | l | c | c | c | l 
  3221. ^  | ^  | ^  | l | c | c | c | l.
  3222. Linking information    m    33    Called SS\(hyuser reference    nm    \ 9    64\ octets  maximum    T{
  3223. \(sc\ 7.30.1\|a)\|1)
  3224. \(sc\ 8.3.30.3
  3225. T}
  3226.             Calling SS\(hyuser reference    nm    10    64\ octets  maximum    T{
  3227. \(sc\ 7.30.1\|a)\|2)
  3228. \(sc\ 8.3.30.4
  3229. T}    Common reference    nm    11    64\ octets  maximum    T{
  3230. \(sc\ 7.30.1\|a)\|3)
  3231. \(sc\ 8.3.30.5
  3232. T}    T{
  3233. Additional reference information
  3234. T}    nm    12    4\ octets  maximum    T{
  3235. \(sc\ 7.30.1\|a)\|4)
  3236. \(sc\ 8.3.30.6
  3237. T}    Old activity identifier    m    41    6\ octets  maximum    T{
  3238. \(sc\ 7.30.1\|a)\|5)
  3239. \(sc\ 8.3.30.7
  3240. T}    Serial number    m    42    6\ octets  maximum    T{
  3241. \(sc\ 7.30.1\|a)\|6)
  3242. \(sc\ 8.3.30.8
  3243. T}
  3244. _
  3245. .T&
  3246. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3247.             New activity identifier    m    41    6\ octets  maximum    T{
  3248. \(sc\ 7.30.1\|b)
  3249. \(sc\ 8.3.30.9
  3250. T}
  3251. _
  3252. .T&
  3253. lw(42p) | lw(18p) | lw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3254.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.30.11
  3255. _
  3256. .T&
  3257. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3258. User data    nm    193                See reference    T{
  3259. \(sc\ 7.30.1\|c)
  3260. \(sc\ 8.3.30.10
  3261. m:
  3262. mandatory.
  3263. nm:
  3264. not mandatory (see \(sc\ 8.2.6).
  3265. .parag
  3266. T}
  3267. _
  3268. .TE
  3269. .nr PS 9
  3270. .RT
  3271. .ad r
  3272. \fBTable 38/X.225 [T38.225], p.\fR 
  3273. .sp 1P
  3274. .RT
  3275. .ad b
  3276. .RT
  3277. .LP
  3278. .bp
  3279. .LP
  3280. 8.3.30.8\ \ The Serial Number PV field shall be coded as specified in
  3281. \(sc\ 8.3.1.10.
  3282. .LP
  3283. 8.3.30.9\ \ The New Activity Identifier PV field shall be as defined by the
  3284. sending SS\(hyuser.
  3285. .LP
  3286. 8.3.30.10\ \ The User Data PV field, if present, shall contain user data
  3287. supplied by the SS\(hyuser.
  3288. .PP
  3289. The length of the User Data parameter is limited such that the
  3290. total length (including SI and LI) of the SPDU does not exceed
  3291. 65\|539\ octets.
  3292. .LP
  3293. 8.3.30.11\ \ The Enclosure Item parameter, if present, shall be encoded as
  3294. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3295. version\ 1 is selected.
  3296. .sp 2P
  3297. .LP
  3298. 8.3.31
  3299.     \fIACTIVITY INTERRUPT (AI) SDPU\fR 
  3300. .sp 1P
  3301. .RT
  3302. .sp 1P
  3303. .LP
  3304. 8.3.31.1\ \ The SI field shall contain the value 25.
  3305. .sp 9p
  3306. .RT
  3307. .LP
  3308. 8.3.31.2\ \ The parameter fields shall be as specified in Table\ 39/X.225.
  3309. .ce
  3310. \fBH.T. [T39.225]\fR 
  3311. .ce
  3312. TABLE\ 39/X.225
  3313. .ce
  3314. \fBParameters of the ACTIVITY INTERRUPT SPDU\fR 
  3315. .ps 9
  3316. .vs 11
  3317. .nr VS 11
  3318. .nr PS 9
  3319. .TS
  3320. center box;
  3321. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3322. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3323. _
  3324. .T&
  3325. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3326.             Reason code    nm    50    1\ octet    \(sc\ 7.31.1 \(sc\ 8.3.31.3
  3327. _
  3328. .T&
  3329. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3330.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.31.4
  3331. _
  3332. .T&
  3333. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3334. User data    nm    193                See reference    T{
  3335. \(sc\ 7.31.1\|b)
  3336. \(sc\ 8.3.31.5
  3337. m:
  3338. mandatory.
  3339. nm:
  3340. not mandatory (see \(sc\ 8.2.6).
  3341. .parag
  3342. T}
  3343. _
  3344. .TE
  3345. .nr PS 9
  3346. .RT
  3347. .ad r
  3348. \fBTable 39/X.225 [T39.225], p.\fR 
  3349. .sp 1P
  3350. .RT
  3351. .ad b
  3352. .RT
  3353. .LP
  3354. 8.3.31.3\ \ The Reason Code PV field shall contain one of the following
  3355. values:
  3356. .LP
  3357.     a)
  3358.     \ \ 0\ No specific reason stated;
  3359. .LP
  3360.     b)
  3361.     \ \ 1\ Temporarily unable to continue;
  3362. .LP
  3363.     c)
  3364.     \ \ 2\ Reserved;
  3365. .LP
  3366.     d)
  3367.     \ \ 3\ User sequence error;
  3368. .LP
  3369.     e)
  3370.     \ \ 4\ Reserved;
  3371. .LP
  3372.     f
  3373. )
  3374.     \ \ 5\ Local SS\(hyuser error;
  3375. .LP
  3376.     g)
  3377.     \ \ 6\ Unrecoverable procedural error;
  3378. .LP
  3379.     h)
  3380.     128\ Demand data token.
  3381. .PP
  3382. All other values are reserved and shall not be used.
  3383. .LP
  3384. 8.3.31.4\ \ The Enclosure Item parameter, if present, shall be encoded as
  3385. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3386. version\ 1 is selected.
  3387. .LP
  3388. 8.3.31.5\ \ The User Data PV field, if present, shall contain user data
  3389. supplied by the SS\(hyuser. This PGI unit shall not be present if protocol
  3390. version\ 1 is selected.
  3391. .PP
  3392. The length of the User Data parameter is limited such that the
  3393. total length (including SI and LI) of the SPDU does not exceed
  3394. 65\|539\ octets.
  3395. .bp
  3396. .sp 2P
  3397. .LP
  3398. 8.3.32
  3399.     \fIACTIVITY INTERRUPT ACK (AIA) SPDU\fR 
  3400. .sp 1P
  3401. .RT
  3402. .sp 1P
  3403. .LP
  3404. 8.3.32.1\ \ The SI field shall contain the value 26.
  3405. .sp 9p
  3406. .RT
  3407. .LP
  3408. 8.3.32.2\ \ The parameter fields shall be as specified in Table\ 40/X.225.
  3409. .ce
  3410. \fBH.T. [T40.225]\fR 
  3411. .ce
  3412. TABLE\ 40/X.225
  3413. .ce
  3414. \fBParameters of the ACTIVITY INTERRUPT ACK SPDU\fR 
  3415. .ps 9
  3416. .vs 11
  3417. .nr VS 11
  3418. .nr PS 9
  3419. .TS
  3420. center box;
  3421. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3422. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3423. _
  3424. .T&
  3425. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3426.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.32.3
  3427. _
  3428. .T&
  3429. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3430. User data    nm    193                See reference    T{
  3431. \(sc\ 7.32.1
  3432. \(sc\ 8.3.32.4
  3433. m:
  3434. mandatory.
  3435. nm:
  3436. not mandatory (see \(sc\ 8.2.6).
  3437. .parag
  3438. T}
  3439. _
  3440. .TE
  3441. .nr PS 9
  3442. .RT
  3443. .ad r
  3444. \fBTable 40/X.225 [T40.225], p.\fR 
  3445. .sp 1P
  3446. .RT
  3447. .ad b
  3448. .RT
  3449. .LP
  3450. 8.3.32.3\ \ The Enclosure Item parameter, if present, shall be encoded as
  3451. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3452. version\ 1 is selected.
  3453. .LP
  3454. 8.3.32.4\ \ The User Data PV field, if present, shall contain user data
  3455. supplied by the SS\(hyuser. This PGI unit shall not be present if protocol
  3456. version\ 1 is selected.
  3457. .PP
  3458. The length of the User Data parameter is limited such that the
  3459. total length (including SI and LI) of the SPDU does not exceed
  3460. 65\|539\ octets.
  3461. .sp 2P
  3462. .LP
  3463. 8.3.33
  3464.     \fIACTIVITY DISCARD (AD) SPDU\fR 
  3465. .sp 1P
  3466. .RT
  3467. .sp 1P
  3468. .LP
  3469. 8.3.33.1\ \ The SI field shall contain the value 57.
  3470. .sp 9p
  3471. .RT
  3472. .LP
  3473. 8.3.33.2\ \ The parameter fields shall be as specified in Table\ 41/X.225.
  3474. .ce
  3475. \fBH.T. [T41.225]\fR 
  3476. .ce
  3477. TABLE\ 41/X.225
  3478. .ce
  3479. \fBParameters of the ACTIVITY DISCARD SPDU\fR 
  3480. .ps 9
  3481. .vs 11
  3482. .nr VS 11
  3483. .nr PS 9
  3484. .TS
  3485. center box;
  3486. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3487. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3488. _
  3489. .T&
  3490. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3491.             Reason code    nm    50    1\ octet    \(sc\ 7.33.1 \(sc\ 8.3.33.3
  3492. _
  3493. .T&
  3494. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3495.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.33.4
  3496. _
  3497. .T&
  3498. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3499. User data    nm    193                See reference    T{
  3500. \(sc\ 7.33.1\|b)
  3501. \(sc\ 8.3.33.5
  3502. m:
  3503. mandatory.
  3504. nm:
  3505. not mandatory (see \(sc\ 8.2.6).
  3506. .parag
  3507. T}
  3508. _
  3509. .TE
  3510. .nr PS 9
  3511. .RT
  3512. .ad r
  3513. \fBTable 41/X.225 [T41.225], p.\fR 
  3514. .sp 1P
  3515. .RT
  3516. .ad b
  3517. .RT
  3518. .LP
  3519. .bp
  3520. .LP
  3521. 8.3.33.3\ \ The Reason Code PV field shall contain one of the following
  3522. values:
  3523. .LP
  3524.     a)
  3525.     \ \ 0\ No specific reason stated;
  3526. .LP
  3527.     b)
  3528.     \ \ 1\ Temporarily unable to continue;
  3529. .LP
  3530.     c)
  3531.     \ \ 2\ Reserved;
  3532. .LP
  3533.     d)
  3534.     \ \ 3\ User sequence error;
  3535. .LP
  3536.     e)
  3537.     \ \ 4\ Reserved;
  3538. .LP
  3539.     f
  3540. )
  3541.     \ \ 5\ Local SS\(hyuser error;
  3542. .LP
  3543.     g)
  3544.     \ \ 6\ Unrecoverable procedural error;
  3545. .LP
  3546.     h)
  3547.     128\ Demand data token.
  3548. .PP
  3549. All other values are reserved and shall not be used.
  3550. .LP
  3551. 8.3.33.4\ \ The Enclosure Item parameter, if present, shall be encoded as
  3552. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3553. version\ 1 is selected.
  3554. .LP
  3555. 8.3.33.5\ \ The User Data PV field, if present, shall contain user data
  3556. supplied by the SS\(hyuser. This PGI unit shall not be present if protocol
  3557. version\ 1 is selected.
  3558. .PP
  3559. The length of the User Data parameter is limited such that the
  3560. total length (including SI and LI) of the SPDU does not exceed
  3561. 65\|539\ octets.
  3562. .sp 2P
  3563. .LP
  3564. 8.3.34
  3565.     \fIACTIVITY DISCARD ACK (ADA) SPDU\fR 
  3566. .sp 1P
  3567. .RT
  3568. .sp 1P
  3569. .LP
  3570. 8.3.34.1\ \ The SI field shall contain the value 58.
  3571. .sp 9p
  3572. .RT
  3573. .LP
  3574. 8.3.34.2\ \ The parameter fields shall be as specified in Table\ 42/X.225.
  3575. .ce
  3576. \fBH.T. [T42.225]\fR 
  3577. .ce
  3578. TABLE\ 42/X.225
  3579. .ce
  3580. \fBParameters of the ACTIVITY DISCARD ACK SPDU
  3581. .ps 9
  3582. .vs 11
  3583. .nr VS 11
  3584. .nr PS 9
  3585. .TS
  3586. center box;
  3587. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3588. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3589. _
  3590. .T&
  3591. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3592.             Enclosure item    nm    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.3.34.3
  3593. _
  3594. .T&
  3595. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3596. User data    nm    193                See reference    T{
  3597. \(sc\ 7.34.1
  3598. \(sc\ 8.3.34.4
  3599. m:
  3600. mandatory.
  3601. nm:
  3602. not mandatory (see \(sc\ 8.2.6).
  3603. .parag
  3604. T}
  3605. _
  3606. .TE
  3607. .nr PS 9
  3608. .RT
  3609. .ad r
  3610. \fBTable 42/X.225 [T42.225], p.\fR 
  3611. .sp 1P
  3612. .RT
  3613. .ad b
  3614. .RT
  3615. .LP
  3616. 8.3.34.3\ \ The Enclosure Item parameter, if present, shall be encoded as
  3617. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3618. version\ 1 is selected.
  3619. .LP
  3620. 8.3.34.4\ \ The User Data PV field, if present, shall contain user data
  3621. supplied by the SS\(hyuser. This PGI unit shall not be present if protocol
  3622. version\ 1 is selected.
  3623. .PP
  3624. The length of the User Data parameter is limited such that the
  3625. total length (including SI and LI) of the SPDU does not exceed
  3626. 65\|539\ octets.
  3627. .sp 2P
  3628. .LP
  3629. 8.3.35
  3630.     \fIACTIVITY END (AE) SPDU\fR 
  3631. .sp 1P
  3632. .RT
  3633. .sp 1P
  3634. .LP
  3635. 8.3.35.1\ \ The SI field shall contain the value 41. This is the same value
  3636. as the SI field for the MAJOR SYNC POINT SPDU (see \(sc\ 8.3.22).
  3637. .sp 9p
  3638. .RT
  3639. .LP
  3640. 8.3.35.2\ \ The parameter fields shall be as specified in Table\ 43/X.225.
  3641. .bp
  3642. .ce
  3643. \fBH.T. [T43.225]\fR 
  3644. .ce
  3645. TABLE\ 43/X.225
  3646. .ce
  3647. \fBParameters of the ACTIVITY END SPDU\fR 
  3648. .ps 9
  3649. .vs 11
  3650. .nr VS 11
  3651. .nr PS 9
  3652. .TS
  3653. center box;
  3654. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3655. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3656. _
  3657. .T&
  3658. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3659.             Serial number    m    42    6\ octets  maximum    T{
  3660. \(sc\ 7.36.1\|a)
  3661. \(sc\ 8.3.35.3
  3662. T}
  3663. _
  3664. .T&
  3665. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3666.             Enclosure item    nm    25    1 octet    \(sc\ 7.37.1 \(sc\ 8.3.35.5
  3667. _
  3668. .T&
  3669. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3670. User data    nm    193                See reference    T{
  3671. \(sc\ 7.36.1\|b)
  3672. \(sc\ 8.3.35.4
  3673. m:
  3674. mandatory.
  3675. nm:
  3676. not mandatory (see \(sc\ 8.2.6).
  3677. .parag
  3678. T}
  3679. _
  3680. .TE
  3681. .nr PS 9
  3682. .RT
  3683. .ad r
  3684. \fBtable 43/X.225 [T43.225], p.\fR 
  3685. .sp 1P
  3686. .RT
  3687. .ad b
  3688. .RT
  3689. .LP
  3690. 8.3.35.3\ \ The Serial Number PV field shall be coded as specified in
  3691. \(sc\ 8.3.1.10.
  3692. .LP
  3693. 8.3.35.4\ \ The User Data PV field, if present, shall contain user data
  3694. supplied by the SS\(hyuser.
  3695. .PP
  3696. The length of the User Data parameter is limited such that the
  3697. total length (including SI and LI) of the SPDU does not exceed
  3698. 65\|539\ octets.
  3699. .LP
  3700. 8.3.35.5\ \ The Enclosure Item parameter, if present, shall be encoded as
  3701. specified in \(sc\ 8.3.4.17. This parameter shall not be present if protocol
  3702. version\ 1 is selected.
  3703. .sp 1P
  3704. .LP
  3705. 8.3.36
  3706.     \fIACTIVITY END ACK (AEA) SPDU\fR 
  3707. .sp 9p
  3708. .RT
  3709. .PP
  3710. The ACTIVITY END ACK SPDU is identical to the MAJOR SYNC ACK SPDU (see 
  3711. \(sc\ 8.3.23). 
  3712. .RT
  3713. .sp 2P
  3714. .LP
  3715. 8.4
  3716.     \fIAdditional encoding rules for segmented SSDUs\fR 
  3717. .sp 1P
  3718. .RT
  3719. .sp 1P
  3720. .LP
  3721.     ACCEPT SPDU
  3722. .sp 9p
  3723. .RT
  3724. .LP
  3725.     REFUSE SPDU
  3726. .LP
  3727.     FINISH SPDU
  3728. .LP
  3729.     DISCONNECT SPDU
  3730. .LP
  3731.     NOT FINISHED SPDU
  3732. .LP
  3733.     ABORT SPDU
  3734. .LP
  3735.     CAPABILITY DATA SPDU
  3736. .LP
  3737.     CAPABILITY DATA ACK SPDU
  3738. .LP
  3739.     GIVE TOKENS SPDU
  3740. .LP
  3741.     PLEASE TOKENS SPDU
  3742. .LP
  3743.     GIVE TOKENS CONFIRM SPDU
  3744. .LP
  3745.     MINOR SYNC POINT SPDU
  3746. .LP
  3747.     MINOR SYNC POINT ACK SPDU
  3748. .LP
  3749.     MAJOR SYNC POINT SPDU
  3750. .LP
  3751.     MAJOR SYNC POINT ACK SPDU
  3752. .LP
  3753.     RESYNCHRONIZE SPDU
  3754. .bp
  3755. .LP
  3756.     RESYNCHRONIZE ACK SPDU
  3757. .LP
  3758.     EXCEPTION DATA SPDU
  3759. .LP
  3760.     ACTIVITY START SPDU
  3761. .LP
  3762.     ACTIVITY RESUME SPDU
  3763. .LP
  3764.     ACTIVITY INTERRUPT SPDU
  3765. .LP
  3766.     ACTIVITY INTERRUPT ACK SPDU
  3767. .LP
  3768.     ACTIVITY DISCARD SPDU
  3769. .LP
  3770.     ACTIVITY DISCARD ACK SPDU
  3771. .LP
  3772.     ACTIVITY END SPDU
  3773. .LP
  3774.     ACTIVITY END ACK SPDU
  3775. .sp 1P
  3776. .LP
  3777. 8.4.1
  3778.     \fIFirst SPDU in sequence\fR 
  3779. .sp 9p
  3780. .RT
  3781. .PP
  3782. The first SPDU in the sequence shall be as specified in \(sc\ 8.3.
  3783. .RT
  3784. .sp 2P
  3785. .LP
  3786. 8.4.2
  3787.     \fISubsequent SPDUs in sequence\fR 
  3788. .sp 1P
  3789. .RT
  3790. .PP
  3791. 8.4.2.1
  3792. For all SPDUs except the REFUSE SPDU and the MINOR SYNC ACK
  3793. SPDU, the encoding shall be as follows:
  3794. .sp 9p
  3795. .RT
  3796. .LP
  3797. 8.4.2.1.1\ \ The SI field shall have the same value as the SI field value of
  3798. the initial SPDU of the sequence.
  3799. .LP
  3800. 8.4.2.1.2\ \ The parameter fields shall be as specified in Table 44/X.225.
  3801. .LP
  3802. 8.4.2.1.3\ \ The Enclosure Item PV field shall indicate whether or not this
  3803. SPDU is the end of the SSDU. The encoding shall be:
  3804. .LP
  3805.     a)
  3806.     bit\ 1\ =\ 0\ not beginning of SSDU;
  3807. .LP
  3808.     b)
  3809.     bit\ 2\ =\ 1\ end of SSDU;
  3810. .LP
  3811.     bit\ 2\ =\ 0\ not end of SSDU.
  3812. .LP
  3813.     Bits 3\(hy8 are reserved.
  3814. .LP
  3815. 8.4.2.1.4\ \ The User Data field, if present, shall contain a segment of the
  3816. associated SSDU. The User Data field shall be present if the Enclosure 
  3817. Item has bit\ 2\ =\ 0. 
  3818. .LP
  3819. .sp 2
  3820. .ce
  3821. \fBH.T. [T44.225]\fR 
  3822. .ce
  3823. TABLE\ 44/X.225
  3824. .ce
  3825. \fBParameters of subsequent SPDUs when segmenting is required\fR 
  3826. .ps 9
  3827. .vs 11
  3828. .nr VS 11
  3829. .nr PS 9
  3830. .TS
  3831. center box;
  3832. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3833. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3834. _
  3835. .T&
  3836. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3837.             Enclosure item    m    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.4.2.1.3
  3838. _
  3839. .T&
  3840. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3841. User data    nm    193                65528\ octets  maximum    T{
  3842. \(sc\ 7.37.1
  3843. \(sc\ 8.4.2.1.4
  3844. m:
  3845. mandatory.
  3846. nm:
  3847. not mandatory (see \(sc\ 8.2.6).
  3848. .parag
  3849. T}
  3850. _
  3851. .TE
  3852. .nr PS 9
  3853. .RT
  3854. .ad r
  3855. \fBtable 44/X.225 [T44.225], p.\fR 
  3856. .sp 1P
  3857. .RT
  3858. .ad b
  3859. .RT
  3860. .PP
  3861. .sp 1
  3862. 8.4.2.2
  3863. For the REFUSE SPDU the encoding shall be as follows:
  3864. .LP
  3865. 8.4.2.2.1\ \ The SI field shall have the same value as the SI field value 
  3866. of the initial SPDU of the sequence. 
  3867. .LP
  3868. 8.4.2.2.2\ \ The parameter fields shall be as specified in Table\ 45/X.225.
  3869. .bp
  3870. .LP
  3871. 8.4.2.2.3\ \ The Enclosure Item PV field shall indicate whether or not 
  3872. this SPDU is the end of the SSDU. The encoding shall be: 
  3873. .LP
  3874.     a)
  3875.     bit\ 1\ =\ 0\ not beginning of SSDU;
  3876. .LP
  3877.     b)
  3878.     bit\ 2\ =\ 1\ end of SSDU;
  3879. .LP
  3880.     bit\ 2\ =\ 0\ not end of SSDU.
  3881. .LP
  3882.     Bits 3\(hy8 are reserved.
  3883. .LP
  3884. 8.4.2.2.4\ \ The Reason Code field, if present, shall contain a segment of the
  3885. associated SSDU. The Reason Code field shall be present if the Enclosure 
  3886. Item has bit\ 2\ =\ 0. 
  3887. .ce
  3888. \fBH.T. [T45.225]\fR 
  3889. .ce
  3890. TABLE\ 45/X.225
  3891. .ce
  3892. \fBParameters of subsequent REFUSE SPDUs when segmenting is
  3893. .ce
  3894. required\fR 
  3895. .ps 9
  3896. .vs 11
  3897. .nr VS 11
  3898. .nr PS 9
  3899. .TS
  3900. center box;
  3901. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3902. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3903. _
  3904. .T&
  3905. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3906.             Enclosure item    m    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.4.2.2.3
  3907. _
  3908. .T&
  3909. lw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3910. Reason code    nm                50    65\|528\ octets  maximum    T{
  3911. \(sc\ 7.37.1
  3912. \(sc\ 8.4.2.2.4
  3913. m:
  3914. mandatory.
  3915. nm:
  3916. not mandatory (see \(sc\ 8.2.6).
  3917. .parag
  3918. T}
  3919. _
  3920. .TE
  3921. .nr PS 9
  3922. .RT
  3923. .ad r
  3924. \fBtable 45/X.225 [T45.225], p.\fR 
  3925. .sp 1P
  3926. .RT
  3927. .ad b
  3928. .RT
  3929. .PP
  3930. 8.4.2.3
  3931. For the MINOR SYNC ACK SPDU the encoding shall be as follows:
  3932. .LP
  3933. 8.4.2.3.1\ \ The SI field shall have the same value as the SI field value 
  3934. of the initial SPDU of the sequence. 
  3935. .LP
  3936. 8.4.2.3.2\ \ The parameter fields shall be as specified in Table\ 46/X.225.
  3937. .LP
  3938. 8.4.2.3.3\ \ The Enclosure Item PV field shall indicate whether or not 
  3939. this SPDU is the end of the SSDU. The encoding shall be: 
  3940. .LP
  3941.     a)
  3942.     bit\ 1\ =\ 0\ not beginning of SSDU;
  3943. .LP
  3944.     b)
  3945.     bit\ 2\ =\ 1\ end of SSDU;
  3946. .LP
  3947.     bit\ 2\ =\ 0\ not end of SSDU.
  3948. .LP
  3949.     Bits 3\(hy8 are reserved.
  3950. .LP
  3951. 8.4.2.3.4\ \ The User Data field, if present, shall contain a segment of the
  3952. associated SSDU. The User Data field shall be present if the Enclosure 
  3953. Item has bit\ 2\ =\ 0. 
  3954. .ce
  3955. \fBH.T. [T46.225]\fR 
  3956. .ce
  3957. TABLE\ 46/X.225
  3958. .ce
  3959. \fBParameters of subsequent MINOR SYNC ACK SPDUs\fR 
  3960. .ce
  3961. \fBwhen segmenting is required\fR 
  3962. .ps 9
  3963. .vs 11
  3964. .nr VS 11
  3965. .nr PS 9
  3966. .TS
  3967. center box;
  3968. cw(42p) | cw(18p) | cw(18p) | cw(54p) | cw(18p) | cw(18p) | cw(30p) | cw(30p) .
  3969. PGI    m/nm    Code    PI    m/nm    Code    Length    Reference
  3970. _
  3971. .T&
  3972. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3973.             Enclosure item    m    25    1\ octet    \(sc\ 7.37.1 \(sc\ 8.4.2.3.3
  3974. _
  3975. .T&
  3976. cw(42p) | cw(18p) | cw(18p) | lw(54p) | cw(18p) | cw(18p) | cw(30p) | lw(30p) .
  3977.             User data    nm    46    65\|528\ octets  maximum    T{
  3978. \(sc\ 7.37.1
  3979. \(sc\ 8.4.2.3.4
  3980. m:
  3981. mandatory.
  3982. nm:
  3983. not mandatory (see \(sc\ 8.2.6).
  3984. .parag
  3985. T}
  3986. _
  3987. .TE
  3988. .nr PS 9
  3989. .RT
  3990. .ad r
  3991. \fBtable 46/X.225 [T46.225], p.\fR 
  3992. .sp 1P
  3993. .RT
  3994. .ad b
  3995. .RT
  3996. .LP
  3997. .bp
  3998.