  3.     T R I P P   L I T E   U P S   S Y S T E M S
  4.                FOR 220-240 VOLT, 60 HZ APPLICATIONS 
  5.  
  6. -------------------------------------------------------------------
  7.  
  8. SmartPro DataCenter UPS Systems
  9. Intelligent, line interactive UPSs for mission-critical network and 
  10. telecom systems
  11.  
  12. Protect your mission-critical network and telecom systems with intelligent,
  13. line interactive UPS systems!  DataCenter UPSs provide simultaneous 
  14. shutdown commands and reporting on up to four individual servers-even if 
  15. those servers are running different operating systems.  They are the ideal 
  16. power protection solutions for all of your mission-critical network and 
  17. telecom systems.  
  18.  
  19. *  Multiple serial ports control up to four servers running different 
  20.     operating systems-simultaneously
  21. *  Extended-run batteries provide up to 100% longer runtime than competitive 
  22.     models to support critical equipment
  23. *  Modular design and hot-swap battery replacement for 100% uptime
  24. *  PowerAlert Software and complete cabling manage and upgrade every 
  25.     network UPS system
  26. *  Multi-level automatic voltage regulation keeps servers working through 
  27.     low voltage (brownouts) and high voltage conditions without using 
  28.     battery power
  29. *  Protect against surges; RFI/EMI line noise filtering prevents interference 
  30.     (i.e. from motors, lights and radio transmissions) from    affecting
  31.     your computer
  32. *  2-year product warranty
  33.  
  34.             SmartPro INT DataCenter UPS Systems                
  35.  
  36.             3000 DC        5000 DC        3000 XR DC    5000 XR DC
  37.  
  38. Output VA        3000        5000        3000        5000        
  39. Output Watts        2100        3500        2100        3500    
  40. Half Load (minutes)        26+        42+        84+        108+    
  41. Full Load (minutes)        11+        18+        36+        42+    
  42. Outlets (IEC-320)         8        8        8        8
  43. Serial Port           4        4        4        4    
  44.  
  45. + Battery times can be extended by adding optional battery packs
  46.  
  47. Optional Battery Packs and Accessories
  48. BP-36V33 (Extends runtime of DataCenter INT 3000 DC)
  49. BP-36VXR (Extends runtimes of DataCenter INT 5000 DC, INT 3000 XR DC, 
  50.     INT 5000 XR DC)
  51. PAM 1 (Power Accessory Modules)
  52. DCOW (Base with casters to ease DataCenter relocation)
  53.  
  54.  
  55. -------------------------------------------------------------------
  56.  
  57. SmartPro NET UPS Systems
  58. Intelligent, line interactive UPSs for network workstations and servers
  59.  
  60. SmartPro NET UPSs provide intelligent, microprocessor controlled protection 
  61. for network servers.  Designed to support heavy network loads, these UPS 
  62. systems provide reliable power protection to ensure all of your equipment 
  63. stays up and running.      
  64.  
  65. *  Winner of Computer Reseller News 1997 Editor's Choice Award
  66. *  PowerAlert Software and complete cabling manage and upgrade every 
  67.     network UPS system
  68. *  Multi-level automatic voltage regulation keeps servers working through 
  69.     low voltage (brownouts) and high voltage without using battery power
  70. *  Reliable battery power keeps your equipment running safely through blackouts
  71. *  Protect against surges; RFI/EMI line noise filtering prevents interference 
  72.     (i.e. from motors, lights and radio transmissions) from affecting 
  73.     + your computer
  74. *  NEW!  New features include:  
  75.     *  Up to three serial ports for multiple server management
  76.     *  Hot-swap battery replacement for 100% uptime
  77.     *  Expandable battery capability for extended runtimes
  78. *  2-year product warranty
  79.  
  80.             SmartPro NET INT UPS Systems
  81.  
  82.             450    700    1000    1400    2200    2200 XL        3000
  83.  
  84. Output VA        450    700    1000    1400    2200    2200        3000    
  85. Output Watts        280    425    620    940    1700    1700        2400
  86. Half Load (minutes)       18    20    24    24    27+    27+        23+
  87. Full Load (minutes)      5    7    9    9    11+    11+        7+
  88. Outlets (IEC-320)          3    3    3    6    6    6        8
  89. Serial Port        1    1    1    2    3    3        3
  90.  
  91. + Battery times can be extended by adding optional battery packs
  92.  
  93. Optional Battery Packs 
  94. BP-24V33 (Extends runtimes of SmartPro INT 2200 NET, INT 2200 XL NET 
  95.     and INT 3000 NET)
  96.  
  97. -------------------------------------------------------------------
  98.  
  99. SmartPro Rackmount UPS Systems
  100. Intelligent, line interactive UPSs for hubs, routers and network servers
  101.  
  102. SmartPro Rackmount provides intelligent, microprocessor controlled protection
  103. for network servers in standard 19" rackmount configuration.  These UPS systems
  104. are designed to provide maximum performance under heavy loads, ensuring your 
  105. systems will remain up and running through power outages.      
  106.  
  107. *  Compact rackmount design (as slim as 3U high) occupies less rack space 
  108.     than competitive UPS systems in the same VA range
  109. *  PowerAlert software and complete cabling manage and upgrade every network
  110.     UPS system
  111. *  Multi-level automatic voltage regulation keeps servers working through low 
  112.     voltage (brownouts) and high voltage conditions without using battery 
  113.     power
  114. *  Reliable battery power keeps networks running through blackouts
  115. *  Protect against surges; RFI/EMI line noise filtering prevents interference 
  116.     (i.e. from motors, lights and radio transmissions) from affecting your 
  117.     computer
  118. *  NEW!  New features include:
  119.     *  Hot-swap battery replacement for 100% uptime
  120.     *  Up to three serial ports for multiple server control
  121.     *  Expandable battery capability for extended runtimes
  122. *  2-year product warranty
  123.             
  124.                 SmartPro INT Rackmount UPS Systems                
  125.  
  126.             700RM    1050RM    1400RM    2200RM    2200RMXL 3000RM
  127.  
  128. Output VA        700    1050    1400    2200    2200     3000
  129. Output Watts        425    705    940    1700    1700     2400
  130. Half Load (minutes)       28    23    26    29+    29+     23+
  131. Full Load (minutes)       12    8    10    13+    13+     7+
  132. Outlets (IEC-320)          6    6    6    8    8     8
  133. Serial Port        2    2    2    3    3     3
  134.  
  135. + Battery times can be extended by adding optional battery packs
  136.  
  137. Optional Battery Packs 
  138. BP-24V33 (Extends runtimes of SmartPro INT 2200 RM, INT 2200 RM XL 
  139.     and INT 3000 RM)
  140. BPRM (Adapter to support BP-24V33)
  141.  
  142. -------------------------------------------------------------------
  143.  
  144. OmniSmart UPS Systems
  145. Line interactive protection for PCs, workstations and servers
  146.  
  147. OmniSmart combines automatic voltage correction with long-lasting 
  148. battery backup power.  These microprocessor controlled systems keep 
  149. you working through voltage problems without using battery power, 
  150. and reliable battery backup keeps you working through  power outages.
  151.  
  152. *  Multi-level Automatic Voltage Regulation adjusts incoming voltage 
  153.     from as low as 164V and as high as 277V back to computer-grade     
  154.     220/240V AC
  155. *  Serial port works with FREE PowerAlert software to manage and upgrade 
  156.     every network UPS system
  157. *  Reliable battery power keeps your equipment running safely through blackouts
  158. *  Protect against surges; RFI/EMI line noise filtering prevents interference 
  159.     (i.e. from motors, lights and radio transmissions) from affecting your 
  160.     computer
  161. *  NEW!  New features include:
  162.     o  Built-in RJ11 jacks provide single or 2-line modem/fax surge 
  163.         protection
  164.     o  Convenient battery replacement door
  165.     o  OmniSmart 300 features a unique split outlet design (2 UPS and 
  166.         surge protected, 1 surge-only) to safeguard your computer and a 
  167.         peripheral
  168. *  2-year product warranty
  169.  
  170.  
  171.             Standard OmniSmart INT PNP UPS Systems                        
  172.  
  173.                                                         Super
  174.             300 PNP            450 PNP        675 PNP        1000 PNP    1400 PNP    Omni
  175.  
  176. Output VA          300              450        675        1000        1400        675
  177. Output Watts          175              280        425        675        940        425
  178. Half Load (minutes)      17              17        17        23        24        17
  179. Full Load (minutes)      5              5        5        7        8        5
  180. Outlets (IEC-320)          3 (2 UPS, 1 surge-only)    3        3        3        4        3
  181. Modem/Fax          X                   X           X                          
  182. Serial Port          X                                X           X            X  
  183. Software          X                              X            X            X  
  184. Battery Access Door      X        
  185.  
  186. -------------------------------------------------------------------
  187.  
  188. Internet UPS Systems
  189. Internet-ready protection for personal computers
  190.  
  191. Internet UPS Systems provide optimum power protection for Internet users.  
  192. Built-in RJ11 jacks safeguard your modem/fax from harmful phone line surges.  
  193. Battery backup maintains your Internet connection and gives you time to safely 
  194. power down your system in the event of a blackout. 
  195.  
  196. *  Battery backup prevents your Internet connection from crashing during short 
  197.     power losses and gives you ample time to safely log off during longer ones
  198. *  Built-in RJ11 jacks prevent surges from interrupting transmissions and 
  199.     corrupting data
  200. *  Protect against brownouts by switching to battery power when incoming voltage 
  201.     dips below acceptable levels
  202. *  Protect against surges; RFI/EMI line noise filtering prevents interference 
  203.     (i.e. from motors, lights and radio transmissions) from affecting your computer
  204. *  2-year product warranty
  205.  
  206.                 Internet I UPS Systems                
  207.  
  208.             300 I        500 I        700 I
  209.  
  210. Output VA        300        500        700    
  211. Output Watts        187        280        425    
  212. Half Load (minutes)       17        17        17    
  213. Full Load (minutes)       5        5        5    
  214. Outlets (IEC-320)       2         3        3    
  215. Modem/Fax              X        X        X                
  216. Battery Access Door                       X    
  217.  
  218. -------------------------------------------------------------------
  219.  
  220. PowerVerter APS Series
  221. Inverters with integrated battery chargers
  222.  
  223. Rugged APS PowerVerters automatically sense and switch to battery power when no 
  224. AC power is available, making them ideal for use as mobile power systems or 
  225. stationary UPS/emergency power supplies.  APS PowerVerters provide reliable 
  226. power to run computers, lighting, fans and more when utility power fails-without 
  227. the hazards, fumes and noise of gas powered generators.
  228.  
  229. *  Efficiently converts 12 volt DC power (from user supplied batteries) 
  230.     to 220/240V AC power
  231. *  Functions as an extended backup-time UPS or emergency power supply when 
  232.     used with BP-260 battery case and 98-121 batteries   
  233.        (sold separately) or user supplied batteries
  234. *  "Peak Power" boosts output 200% for motor starting and heavy peak demands
  235. *  Modified sine-wave output handles heavy inductive loads
  236. *  Built-in heavy-duty battery charger maintains batteries when not in use
  237. *  Electronic overload shutdown and input polarity protection
  238.  
  239. Optional Battery Packs 
  240. 98-121 (For use with all APS models)
  241. BP 260 (Battery case with cables; holds two 98-121 batteries-not included) 
  242.  
  243.             APS INT Standby UPS Systems                
  244.  
  245.             400        750        1250
  246.  
  247. Output VA        400        750        1250    
  248. Output Watts        400        750        1250    
  249. Half Load (minutes)                  Battery Dependent    
  250. Full Load (minutes)                  Battery Dependent    
  251. Outlets (NEMA 5-15)    2         2        2    
  252.  
  253. -------------------------------------------------------------------
  254.