  9. Content-Type: text/plain; charset=iso-8859-1
  10. Content-Transfer-Encoding: 8bit
  11. Mime-Version: 1.0
  12.  
  13. >Can you use the MUX driver if you have a serial mouse?
  14.  
  15. Yes. The problem is that Config.app needs the old serial
  16. driver as well!! That means that you have to change
  17. the Default.table of SerialPorts.config, because SerialPorts
  18. always wants TWO serial ports.
  19.  
  20. Do the following thing:
  21. 1) MAKE A SAVETY COPY of the old SerialPorts.config
  22. 2) Change Default.table to the version supplied with
  23.    the Mux packet.
  24. 3) Remove instance0.table
  25. 4) Start Config.app and add the SerialPort again!
  26.    (Now it should be only ONE serial port)
  27.  
  28. Greetings, Constantin
  29.  
  30. -- 
  31. <-------------------------------------------------------------->
  32. | Constantin Szallies               |||     tini@gurke.ping.de |
  33. | Emil Figge 7  44227 Dortmund     (o o)     Tel: 0231/7519681 |