  1. Path: sparky!uunet!stanford.edu!agate!usenet.ins.cwru.edu!magnus.acs.ohio-state.edu!cis.ohio-state.edu!pacific.mps.ohio-state.edu!linac!uwm.edu!caen!sdd.hp.com!elroy.jpl.nasa.gov!ames!sun-barr!west.West.Sun.COM!cronkite.Central.Sun.COM!texsun!exucom.exu.ericsson.se!ericom!sunic!mcsun!sun4nl!troy!geveld
  2. From: geveld@thijssen.nl (Ge v.d. Veldt)
  3. Newsgroups: vmsnet.pdp-11
  4. Subject: 11/94 Upgrade problems....
  5. Message-ID: <1992Nov12.151415.21751@thijssen.nl>
  6. Date: 12 Nov 92 15:14:15 GMT
  7. Organization: Thijssen BV, Veenendaal, The Netherlands
  8. Lines: 40
  9.  
  10.  
  11. Hello,
  12.  
  13. We experienced 2 problems while upgrading a PDP11/84 to a PDP11/94.
  14. The PDP 11/84 contains very old hardware such as:
  15.  
  16.         Emulex SC21 diskcontroller with M2322 Fujitsu disk
  17.         RL11 diskcontroller
  18.         Delua ethernet controller
  19.         Emulex TC12 tapecontroller with M890 Cipher drive
  20.         DL11-W asynchronous controller
  21.         DZ11 asynchronous Multiplexer
  22.         DT07 unibusswitch
  23.         ICR11 I/O subsystem
  24.         Fisher and Porter CCM communication controller
  25.  
  26. Problem 1:
  27. The RSX11M-plus operating system crashes at random time intervals with the 
  28. following console message:
  29.  
  30.         XXXXXXXXX Exec. parity error stop XXXXXXXXX
  31.  
  32. After that the CPU halts, no time to generate an errorlog entrie. The same
  33. system has no problems when the CPU is a PDP11/84.
  34.  
  35. Problem 2
  36. The PDP11/94 processor seem to have another power-up sequence compared with 
  37. the PDP11/84. When the DT07 has selected  the PDP11/94 CPU for unibus exten-
  38. sion the frontpanel halt/reset tockle switch will bring the CPU in a not 
  39. accessable  state when manipulated. The only way to get out of that state 
  40. (without powering down the system) is to deselect the unibusextension via the
  41. DT07 frontpanel switches and restart the 11/94 again. This time the normal
  42. powerup sequence will take place.
  43.  
  44.         WHO HAS  ANY  SUGGESTIONS FOR THESE PROBLEMS????
  45.  
  46.  
  47. -- 
  48. Ge van der Veldt, Thijssen BV, Veenendaal. The Netherlands.
  49. Email: geveld@thijssen.nl