- Newsgroups: comp.sys.xerox
- Path: sparky!uunet!charon.amdahl.com!pacbell.com!ames!sun-barr!cs.utexas.edu!zaphod.mps.ohio-state.edu!pacific.mps.ohio-state.edu!cis.ohio-state.edu!envos.xerox.COM!John_D._Sybalsky.MV
- From: John_D._Sybalsky.MV@envos.xerox.COM
- Subject: Re: XNS protocol specs : where can I get them
- Message-ID: <92Nov11.141226pst.12746@alpha.xerox.com>
- Sender: info-1100-request@cis.ohio-state.edu
- Organization: Info-1100 Mailing List
- References: John_D._Sybalsky.MV@envos.xerox.COM
- Date: Wed, 11 Nov 1992 21:59:00 GMT
- Lines: 9
-
- You'll have to write to Xerox to get the specs; I don't have the address right
- at hand, but I'll hunt.
-
- It's possible that you're running older XNS on the VAX; a change was made to
- the SPP that is effective with the newer 8090 server code: Right after
- initiating the connection, the server sends an EOM, which the client has to
- discard. If you aren't discarding that, it can appear as dropped connections
- and inability to connect.
-
-