home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.sys.cbm
- Path: sparky!uunet!zaphod.mps.ohio-state.edu!darwin.sura.net!spool.mu.edu!yale.edu!ira.uka.de!math.fu-berlin.de!mailgzrz.TU-Berlin.DE!cs.tu-berlin.de!nevs
- From: nevs@cs.tu-berlin.de (Sven Goldt)
- Subject: Re: Trouble with 1084 Monitor
- Message-ID: <1992Nov11.150329.29054@cs.tu-berlin.de>
- Sender: news@cs.tu-berlin.de
- Organization: Techn. University of Berlin, Germany
- References: <1992Nov10.223431.2605@news.ysu.edu>
- Date: Wed, 11 Nov 1992 15:03:29 GMT
- Lines: 16
-
-
- The first 1084 i owned,has had problems with the line transformator,so
- i bought a new transformator.Then it worked again.
- I bought a second 1084 used really cheap,'cause it had problems with
- the transformator,too ! I just soldered the contacts and now it works
- 100%.So this is a common failure with the 1084.The line
- transformator loses contact. I mean the LINE Transformator,
- High Voltage,it steers the video screen,not the power transformator.
-
- --
- *******************************************************************************
- * feel free to mail to nevs@cs.tu-berlin.de /"/ /"| / /"" *
- * nevs = Sven Goldt / / /" |/ "/ *
- * ' ' '" " """ *
- * # THE MOST IMPORTANT FINANCIAL QUESTION IS: Where is the money ? # *
- *******************************************************************************
-