home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #26 / NN_1992_26.iso / spool / comp / sys / amiga / datacomm / 7531 < prev    next >
Encoding:
Internet Message Format  |  1992-11-09  |  1.9 KB

  1. Path: sparky!uunet!spool.mu.edu!umn.edu!math.fu-berlin.de!unidui!Germany.EU.net!rz.uni-hildesheim.de!ix.de!agsc!amiux!sourcery!olsen
  2. From: olsen@sourcery.mxm.sub.org (Olaf Barthel)
  3. Message-ID: <olsen.5173@sourcery.mxm.sub.org>
  4. Newsgroups: comp.sys.amiga.datacomm
  5. Subject: Re: Weird problem with Term 2.4 and CPUblit
  6. Distribution: world
  7. X-NewsSoftware: GRn 1.16e (7/4/92) by Mike Schwartz & Michael B. Smith
  8. Date: 8 Nov 92 18:58:46 CET
  9. Organization: MXM Barthel & Paesler
  10. Lines: 28
  11.  
  12. In article <t7h1+w#@rpi.edu> pooler@aix02.ecs.rpi.edu (Robert Peter Poole) writes:
  13. > OK, this is something I just noticed.  I run CPUblit from my WBStartup
  14. > drawer, and I also leave my computer running for weeks at a time without
  15. > turning it off; often I don't reboot for days at a time.  I've noticed
  16. > that after a reboot, running Term 2.4 once is fine -- CPUblit does its
  17. > thing.  Now, I run Term in a 16 color screen, so without CPUblit, the scrolling
  18. > would be slow, and there'd be rainbow trailers everywhere.
  19.  
  20.    CPUBlit is not a miracle cure. It is capable of moving data around simultaneously
  21. in two bitplanes while the operating system would run the blitter on each single
  22. bitplane. With a 16 colour screen CPUBlit would require two runs, whereas the
  23. operating systemroutines would require four runs.
  24.  
  25.    If you don't like the rainbow trailers, turn on the `faster layout' switch.
  26. Scrolling will not be faster, though. If you really wish to use 16 colours with
  27. `term', try an A4000.
  28.  
  29. > Rob Poole
  30. > pooler@rpi.edu
  31. > pooler@cs.rpi.edu
  32.  
  33. -- 
  34. Olaf Barthel       | Internet: olsen@sourcery.mxm.sub.org
  35. Brabeckstrasse 35  |           o.barthel@a-link-h.comlink.de
  36. D-3000 Hannover 71 |           cbmvax.commodore.com!cbmehq!sourcery!olsen
  37. MXM, ECG127        |   Z-Netz: O.BARTHEL@A-LINK-H
  38. -------------------------------------------------------------------------
  39.                       Ceci n'est pas une signature.
  40.