  1. Newsgroups: comp.sys.att
  2. Path: sparky!uunet!gatech!gsusgi1.gsu.edu!gsusgi1.gsu.edu!regmad
  3. From: regmad@gsusgi2.gsu.edu (Michael de Kraker)
  4. Subject: Re: HELP 3b2 dead
  5. Message-ID: <regmad.715925401@gsusgi1.gsu.edu>
  6. Organization: Georgia State University
  7. References: <regmad.715623743@gsusgi1.gsu.edu> <1992Sep6.230135.26640@alf.cooper.edu>
  8. Date: Tue, 8 Sep 1992 04:10:01 GMT
  9. Lines: 36
  10.  
  11. hak@alf.cooper.edu (Jeff Hakner) writes:
  12.  
  13. >in article <regmad.715623743@gsusgi1.gsu.edu>, regmad@gsusgi2.gsu.edu (Michael de Kraker) says:
  14.  
  15. >> Again I tried several terminals at all settings and have always been aware
  16. >> of the port requirements. The death of the 610 terminal may have been 
  17. >> a clue. Possibly the console circuitry is fried on the 3b2 end killing my
  18. >> terminal or vice versa.
  19. >> 
  20. >[...]
  21. >> 
  22. >> I suspected this but wholesale replacement of the mother board is not fixing,
  23. >> it is replacing. I have no source for a mother board either. Where can I get
  24. >> one. Maybe it is the power supply what are the voltages and test points????
  25. >> 
  26. >> Again thanks for the response to everyone but need suggestions for clues
  27. >> as to the system with solid power and diag led's. 
  28. >Let's be clear here.  Your apply power, move the power switch to ON,
  29. >then both the POWER and DIAG lights remain lit?  Make sure that
  30. >the power light is not flashing in a repeating pattern.  This is
  31. >what the 3B2 does when it concludes that the console is dead, or it
  32. >can't get to the point where it can display SELF CHECK.
  33.  
  34. >Assuming that you get solid POWER and DIAG, try waiting a minute
  35. >or so, then hit the reset switch (in rear on 3B2/300,310,400).
  36. >If the floppy drive spins briefly, this is a good sign.  Check
  37. >the console serial connection with a $10 RS232 LED breakout box.
  38. >You should see signal on Txmt and DTR.
  39.  
  40. Just to continue the saga 
  41.  
  42.     Power and diag lights on solid.. wait hit reset and nothing
  43.  
  44.     attach breakout box and no control signals.. period...
  45.  