home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.sys.apollo
- Path: sparky!uunet!tron!dbrown
- From: dbrown@tron.bwi.wec.com (Darryl Brown)
- Subject: Re: Colour maps on DN4500 (again??)
- Message-ID: <1992Sep9.201954.23279@tron.bwi.wec.com>
- Organization: Westinghouse Electric Corporation, Baltimore MD.
- References: <S9209041457.AA28091@uk.ac.aberdeen.sysc>
- Date: Wed, 9 Sep 1992 20:19:54 GMT
- Lines: 24
-
-
- > <S9209041457.AA28091@uk.ac.aberdeen.sysc> writes
- > We have a DN4500 running SR10.3 (no patches) which has an 8 plane
- > 19 inch colour monitor.
-
- > The command "lcm" was typed in at one of the pads and this changed
- > the colour map. The question is, how do I get it back to "normal".
-
-
- I experienced what seems to be the same problem with mixed-up
- colors on a DN4500 when I swapped the mono display out of it for an
- 8-plane color monitor.
- At the time the machine was running SR 10.1. I noticed that
- all of the reds and blues were swapped on the display, and that lcm
- did not change anything. My solution was to swap the red and blue
- BNC cables on the back of the monitor so the Red wire goes to the
- Blue input and vice-versa. It is still running with the same
- mis-configuration under SR 10.3.
-
- -Darryl Brown
- --
- # Darryl K. Brown | brown@sky00.tron.bwi.wec.com #
- # Westinghouse ESG | #
- # Baltimore, MD | #
-