home *** CD-ROM | disk | FTP | other *** search
- Path: sparky!uunet!mcsun!uknet!harrier.ukc.ac.uk!eagle.ukc.ac.uk!jhma
- From: jhma@ukc.ac.uk (J.H.M.Aldridge)
- Newsgroups: comp.sys.acorn.tech
- Subject: Re: Taxan 875 Plus Monitor as a HRM
- Message-ID: <1588@eagle.ukc.ac.uk>
- Date: 8 Sep 92 15:41:30 GMT
- References: <5532@shum.huji.ac.il>
- Reply-To: jhma@ukc.ac.uk (J.H.M.Aldridge)
- Organization: Computing Lab, University of Kent at Canterbury, UK.
- Lines: 28
-
- In article <5532@shum.huji.ac.il> mybg@shum.huji.ac.il (Michael Ben-Gershon) writes:
- >The Taxan 875+ Monitor should be able to work as a High Res Monitor with 400
- >and 540 series Acorn RISC computers (Archimedes), as it has an H scan
- >frequency up to 75 kHz.
- >
- >Does anyone know how to connect it? On its rear, it has R G/S B H/C V
- >sockets, but these are not well documented in the manual. I presume that R,G,B
- >are obvious, but what is G/S and what is H/C? Could it be that the composite
- >video output from the Archimedes needs to be split into 3, each going to
- >one of the 3 R,G,B sockets on the monitor (a sort of opposite version of
- >cable type MF on page 87 of the 540 series Installation Guide) ?
- I guess that the connections are:
- R = Red
- G = Green (possible with syncs on this line too!)
- B = Blue
- H = Horizontal (or composite) syncs
- V = Vertical syncs
- Thus the R,G, and B outputs from the Archimedes should go to the
- R,G, and B inputs of the monitor. If the archimedes outputs composite H and V
- syncs then this should go to the monitor's H/C input otherwise seperate H and V
- syncs should go to the appropriate individual input on the monitor (I can't
- remember what the Archimedes puts out in the way of syncs!).
-
- --James
-
- >
- >Michael Ben-Gershon
- >mybg@shum.huji.ac.il OR mybg@doc.ic.ac.uk
-