home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #19 / NN_1992_19.iso / spool / comp / sys / hp / 9654 < prev    next >
Encoding:
Internet Message Format  |  1992-08-25  |  1.8 KB

  1. Path: sparky!uunet!ogicse!hp-cv!hp-pcd!hpcvusn!hpcvxph!tomg
  2. From: tomg@hpcvxph (Thomas J. Gilg)
  3. Newsgroups: comp.sys.hp
  4. Subject: Re: shutdown/update frustration on 700s
  5. Message-ID: <1992Aug25.165411.24343@hpcvusn.cv.hp.com>
  6. Date: 25 Aug 92 16:54:11 GMT
  7. Article-I.D.: hpcvusn.1992Aug25.165411.24343
  8. References: <lee.714599840@ceg.uiuc.edu>
  9. Sender: nobody@hpcvusn.cv.hp.com (Nobody - UID must be 99999)
  10. Organization: Hewlett-Packard Company, Corvallis, Oregon USA
  11. Lines: 38
  12. Nntp-Posting-Host: hpcvxph.cv.hp.com
  13. X-Newsreader: Tin 1.1 PL5
  14.  
  15. Chris Lee (lee@ceg.uiuc.edu) wrote:
  16.  
  17. > The screen blinks, and we seen the VUE login window, there is a blip,
  18. > and we see some of the left-over text on the console screen, and then
  19. > it goes BLANK!
  20.  
  21. From an active defect report against the Xserver:
  22.  
  23. -----
  24.  
  25. Description:
  26.    no-windows login results in black screen with large "X", login obscured
  27.  
  28. Submitter:
  29.    After starting up vue with "init 3; exit" I chose to login
  30.    with no windows.  The screen then blanked showing only a
  31.    frozen X graphics cursor.  I had to press "SHIFT-RESET"
  32.    in order for the graphics to exit and display the alpha
  33.    screen.  This same behavior was experienced on both the
  34.    cluster server, a S750, and a client, a S735.  This seems
  35.    to be new behavior after an IC2 update last week.
  36.  
  37. Labnotes:
  38.    ..... I have discovered that the X server is not performing the
  39.    required ioctl(GCTERM) system call.
  40.  
  41. Labnotes2:
  42.    I have verfied that GCTERM ioctl is resetting the correct set of planes.
  43.    It appears that the X server is not making the GCTERM ioctl call.
  44.  
  45. -----
  46.  
  47. I just asked our quality dept. to keep this defect rated as "critical"
  48. rather than downgrading it just because it has the SHIFT-RESET workaround.
  49. In a few more day, the defect will be advertised to field support also.
  50.  
  51. Thomas Gilg
  52. tomg@cv.hp.com
  53.