home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #19 / NN_1992_19.iso / spool / comp / sys / handheld / 1934 < prev    next >
Encoding:
Internet Message Format  |  1992-08-29  |  1.3 KB

  1. Xref: sparky comp.sys.handhelds:1934 comp.sys.hp48:4413
  2. Newsgroups: comp.sys.handhelds,comp.sys.hp48
  3. Path: sparky!uunet!haven.umd.edu!news.umbc.edu!gmuvax2!peraino
  4. From: peraino@gmuvax2.gmu.edu
  5. Subject: Problem interfacing hp48. Please help!
  6. Message-ID: <1992Aug28.141602.24945@gmuvax2.gmu.edu>
  7. Followup-To: poster
  8. Keywords: hp48 serial connection
  9. Organization: George Mason University, Fairfax Va.
  10. Date: Fri, 28 Aug 1992 14:16:02 GMT
  11. Lines: 29
  12.  
  13.  
  14.  
  15. I recently purchased a receiver that allows computer control, and I would
  16. like to control it from my hp48. The problem is, the receiver expects
  17. RTS/CTS handshaking. The pinout for the receiver DB-9 is as follows:
  18.  
  19. 1- Scan feedback - +5 volts is receiver unsquelched
  20. 2- Rx data
  21. 3- Rx data
  22. 4- DTE ready
  23. 5- Ground
  24. 6- DCE ready
  25. 7- RTS
  26. 8- CTS
  27. 9- Ground
  28.  
  29.  
  30. I have tried the following: tie pins 4 & 6 together, and tie pins 7 & 8
  31. together, so it thinks everything is always ready. This does not work.
  32. The receiver is fixed at 9600 baud, 1 start bit, 7 data bits, 1 stop bit,
  33. even parity. When I try the above configuration, the receiver thinks it's
  34. connected to a computer, but when I try to send a few characters, I
  35. expect to get specific responses, and I get parity errors on the '48.
  36. I have tried ALL of the parity settings on the '48. Can anyone help?
  37. Please respond directly. Thank you!
  38.  
  39. Bob Peraino
  40.  
  41. peraino@gmuvax.gmu.edu
  42.