home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #19 / NN_1992_19.iso / spool / comp / sys / dec / micro / 494 < prev    next >
Encoding:
Text File  |  1992-08-30  |  1.2 KB  |  22 lines

  1. Newsgroups: comp.sys.dec.micro
  2. Path: sparky!uunet!utcsri!torn!watserv2.uwaterloo.ca!watdragon.uwaterloo.ca!kcwellsc
  3. From: kcwellsc@watdragon.uwaterloo.ca (Ken Wellsch)
  4. Subject: Re: Pro/Venix Installation
  5. Message-ID: <Bts2CG.MM0@watdragon.uwaterloo.ca>
  6. Organization: University of Waterloo
  7. References: <1992Aug27.152838.26907@lotus.com> <1992Aug29.052756.7383@menudo.uh.edu> <1992Aug29.194138.12101@news.columbia.edu>
  8. Date: Sun, 30 Aug 1992 03:43:27 GMT
  9. Lines: 11
  10.  
  11. > An ST-225 is RD31 and *is* standard.  Make sure that it selects on DS0. 
  12. > You'll know you're right because it will light up when selected.
  13.  
  14. The only point I would like to make about determining whether drive RDxx
  15. works okay is this:  my experience with Pro's and RD drives is that if
  16. the drive meets or exceeds the required # hds/cyls etc. it may appear
  17. to be working fine but you may well not be using more than say the drive
  18. it thinks it is.  Example, if an RD51 is not jumpered correctly, a Pro
  19. (with Venix) will happily think the drive is an RD50 (5Mb rather than
  20. 10Mb).  So please if you find something works, check how much space you
  21. *really* have available, it may not be the actual drive's capacity at all.
  22.