home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.dcom.sys.cisco
- Path: sparky!uunet!boulder!recnews
- From: vsg%tron!plaza.dnet@uunet.UU.NET (Marty Adkins, (W) ESG Distributed Systems, MS 1615, WIN 285-1479)
- Subject: RE: Token-Ring not reset after beaconing
- Message-ID: <9208211455.AA06164@relay2.UU.NET>
- Sender: news@colorado.edu
- Date: 21 Aug 92 09:27:14 -0400
- Lines: 24
-
- >Hello,
- > I believe I have seen this problem mentioned before and I am
- >wondering if there is a fix yet.
- > I am running GS3-BFX 9.0(1) in an AGS+. On several occasions
- >a beaconing condition on the token-ring has caused the token-ring
- >interface on the cisco to go down. The interface does not reset
- >automatically, but must be manually reset via software
- >(shutdown, no shutdown).
- >Thanks,
- > Bill
- >
- >Bill Rippon Phone: 914-784-7479
- >IBM Watson Research Center Email: bjripp@watson.ibm.com
- ............................................................................
- We reported the same problem over a month ago and were told new code was
- available which corrects this problem. We subsequently obtained 9.0(1.10)
- patch level which so far appears to be holding up, although rings don't
- beacon all that often. In general, this release has made the token ring
- considerably more robust in reacting to events on the ring.
-
- Marty Adkins
- Distributed Systems
- Westinghouse Electronic Systems Group
- Internet: Adkins@plaza.wec.com
-