  1. Newsgroups: comp.dcom.lans.ethernet
  2. Path: sparky!uunet!sun-barr!ames!sgi!rigden.wpd.sgi.com!rpw3
  3. From: rpw3@rigden.wpd.sgi.com (Rob Warnock)
  4. Subject: Re: what is SQE  (DUMB QUESTION!)
  5. Message-ID: <pe5ef64@sgi.sgi.com>
  6. Sender: rpw3@rigden.wpd.sgi.com
  7. Organization: Silicon Graphics, Inc.  Mountain View, CA
  8. Date: Fri, 4 Sep 1992 13:31:09 GMT
  9. Lines: 22
  10.  
  11. nason@pa881a.inland.com writes:
  12. +---------------
  13. | ccewch@nuscc.nus.sg (Wong Chee Heng) writes:
  14. | > Why SQE must be turned off when connecting to Ethernet V2 device?
  15. |
  16. | Ethernet V2 devices(no 802.3 conformance) cannot accept the 802.3 SQE-test.
  17. +---------------
  18.  
  19. WRONG-O! The Ethernet v.2 spec contains the "Collision Presence Test"
  20. (see Section 7.4.7), which is exactly the same as 802.3 SQE-test.
  21.  
  22. It's Ethernet v.1 that can't hack the SQE test...
  23.  
  24.  
  25. -Rob