home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #18 / NN_1992_18.iso / spool / comp / sys / transput / 946 < prev    next >
Encoding:
Internet Message Format  |  1992-08-18  |  2.5 KB

  1. Path: sparky!uunet!cis.ohio-state.edu!ucbvax!THEORY.TC.CORNELL.EDU!sjb
  2. From: sjb@THEORY.TC.CORNELL.EDU (Stephen J. Bradshaw)
  3. Newsgroups: comp.sys.transputer
  4. Subject: C40 Info
  5. Message-ID: <9208182321.AA27890@theory.TC.CORNELL.EDU>
  6. Date: 18 Aug 92 23:21:31 GMT
  7. Sender: daemon@ucbvax.BERKELEY.EDU
  8. Distribution: world
  9. Organization: The Internet
  10. Lines: 54
  11.  
  12. > Is there a list of current vendors who are offering support (hardware
  13. > and software) for the C40? I've been trying to follow what's available
  14. > for it since it was first announced, but haven't seen that much
  15. > advertising done.
  16.  
  17. Yes there is. Actually it is a TI publication which you can get by
  18. calling (800) 336 5236 or their DSP hotline (713) 274 2320. I'm sorry I
  19. dont have access to the appropriate telephone numbers outside the US.
  20. At worst, just call your local TI office and ask them to arrange for a
  21. copy to be sent to you.
  22.  
  23.  
  24.     TMS320 Third Party Support Reference Guide
  25.     Digital Signal Processing Products
  26.     Texas Instruments
  27.     1992
  28.  
  29. Good luck.
  30.  
  31. > I have a new (Transtech) transputer-based system here, and would like
  32. > to think about mixing in C40's in the future.  However, I don't know
  33. > how various vendors are making this feasible.  Does TI have any info on
  34. > its third-party supporters that would be mailable, or should one
  35. > contact individual vendors first?
  36.  
  37. >From what I have heard there was one transputer company in the UK that
  38. had a C40 on a TRAM, but they recently went bust.
  39.  
  40. Existing tranpsuter systems CAN be connected to C40 systems by
  41. developing a C40 Communiction Port <---> Transputer Link interface. For
  42. the hardware inclined, this is a relatively striaghtforward deisgn
  43. exercise, although you would be advised to map a single transputer link
  44. onto two C40 Communication Ports. The transputer link should be used in
  45. a bi-directional mode and the C40 Communication Ports used in
  46. uni-directional modes (one for each direction).
  47.  
  48. This interface is being developed for customers of our C40 systems
  49. as a TIM-40 module with three transputer link interface connections and
  50. will have the ability to propogate control signals (i.e. reset) between
  51. the two systems. The interface is intended to be transparent although
  52. the user would have to be concerned about packing and unpacking of
  53. data, due to the C40 being limited to addressing data on 32-bit word
  54. boundaries.
  55.  
  56. Regards,
  57.  
  58.  
  59. Steve Bradshaw                 
  60. Traquair Data Systems
  61. Judd Falls Plaza, Suite 80      
  62. Ithaca, NY 14850                
  63.  
  64. Phone: (607) 272 4417           
  65. Fax:   (607) 272 4417
  66.