- kens@netcom.com (Ken Schneider) writes:
-
- >I'm trying to set up a network with two Sparc 2's using
- >twisted pair. We've got w 10baseT transceivers from Marvell Technology
- >that hook right on to the AUI connectors on the Sparcs. I've configured the
- >systems' software correctly (I think), but when I ping - the transmit light
- >flashes, but the other node doesn't receive any packets. I think the problem
- >may be the twisted pair cable that we put together. Does anyone know the
- >correct wiring for a twisted pair cable (xmit, receive wires ??).
- >Thanks
- >Ken Schneider
-
- Normally with 10BaseT Cables they are 8 wires (actually only 4 are used)
- wired straight through. This is the normal situation where you have a
- 10BaseT hub DRIVING Outputs to the 10BaseT tranceivers on the
- workstations. If you are doing what I think you are doing which is
- connecting the two tranceivers on the workstations back to back with the
- 10BaseT cable and not using a hub then you will have to use a cross-over
- 10BaseT cable which crosses over the Transmit and Receive pairs:
-
- Pin
- 1 Rx+
- 2 Rx-
- 3 Tx+
- 6 Tx-
-