- Path: sparky!uunet!stanford.edu!rutgers!cmcl2!adm!news
- From: beyer@bflsgu.fl.bs.dlr.de (R. Beyer)
- Newsgroups: comp.sys.sgi
- Subject: Exabyte
- Message-ID: <31815@adm.brl.mil>
- Date: 14 Aug 92 10:55:10 GMT
- Sender: news@adm.brl.mil
- Lines: 40
-
-
-
- Dave Olson answers:
-
- | I don't know how to verify what the firmware rev is of the Exabyte unless it's
- | that 4 digit number at the end of the Device line of an mt stat command. 4 of
- | our Exabytes have the string "425A", the other one (used above) has the string
- | "251X".
-
- 425A and 252T are the only firmware revs SGI has shipped.
-
-
- I just installed a replacement Exabyte sent by SGI which gives the following
- status information:
-
- Controller: SCSI
- Device: EXABYTE: EXB-8200 2647
- Status: 0x262
- Media : READY, writable, at BOT
-
- I only replaced the Exabyte system from an otherwise functioning backup
- environment and now the Exabyte produces a new error
-
- failed I/O error: guest@bflsgu:/dev/nrexa feom 1
-
- although this command presented no problems before.
-
- Regards
-
-
-
-
-
-
- ---------------------------------------------------------------------
- Ralf Beyer - German Aerospace Research Establishment, Institute for
- Flight Guidance, Flughafen, D-3300 Braunschweig, Fed. Rep. of Germany
- Phone: 0049-531-395-2530 Fax: 0049-531-395-2550