  9. Date: Thu, 13 Aug 1992 17:40:01 GMT
  10. Lines: 68
  11.  
  12. -
  13. One kind of NULL modem cable is as follows:
  14.  
  15.     pin                     pin
  16.     1------------------------1
  17.     2------------------------3* see note
  18.     3------------------------2
  19.     4---+           +--------4
  20.         |           |
  21.     5---+           +--------5
  22.  
  23.     7------------------------7
  24.  
  25.     6---+           +--------6
  26.         |           |
  27.     8---+           +--------8
  28.         |           |
  29.     20--+           +-------20
  30.  
  31.  
  32. An official null modem cable is only good if using official null modems  :-)
  33. If the above doesn't work, then it is likely that you don't really need a null
  34. modem.  Change the above so that pin 2 connects to 2 and 3 to 3 and try again.
  35. The above is a simple version that does not support device signaling.
  36.  
  37.  
  38. If you need hardware handshaking or what is sometimes called a 7 wire connection
  39. then use the following:
  40.  
  41.     pin                     pin
  42.     1------------------------1
  43.     2------------------------3* see note
  44.     3------------------------2
  45.     4------------------------5
  46.     5------------------------4
  47.     6-----------------+------8
  48.               |
  49.               +-----20
  50.  
  51.     7------------------------7
  52.     8---+
  53.         |
  54.     20--+--------------------6
  55.  
  56.  
  57. The above should work for most all devices.  The trouble is that the
  58. RS232C standard does not clearly define how manufactures are going to
  59. configure their machines.  The RS323C standard only defines things like
  60. the voltages and the physical connector.
  61.  
  62. gud luck, If it don't work then
  63. the number to call is
  64. BR 549
  65.  
  66.  
  67.  
  68. --
  69. -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
  70.                  |     Vincent Herried  (614) 447-3600 x 2877
  71.                  |     Chemical Abstracts Service
  72.  _____________________           |     P.O. Box 3012
  73. (_)________________   \          |     Columbus, OH 43210-0012
  74.   ________________|\   \         |
  75.  (_)______________\_\   \        |     Current thought: People who cannot be
  76.    ______________________\       |     understood are geniuses, so management
  77.   (_)____________________|       |     assigns them the toughest projects.
  78.                  |
  79. -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
  80.