home *** CD-ROM | disk | FTP | other *** search
- Xref: sparky comp.dcom.modems:12249 biz.comp.telebit:834
- Path: sparky!uunet!uvaarpa!darwin.sura.net!mips!sdd.hp.com!usc!sol.ctr.columbia.edu!samsung!news.cs.indiana.edu!syscon!gator!larry
- From: larry@gator.rn.com (Larry Snyder)
- Newsgroups: comp.dcom.modems,biz.comp.telebit
- Subject: Re: WB Strangeness
- Message-ID: <Bt87u6.LCL@gator.rn.com>
- Date: 19 Aug 92 10:30:06 GMT
- References: <1992Aug12.222706.23021@mccc.edu> <1992Aug18.013925.12634@jpradley.jpr.com>
- Organization: The Gator Public Access Unix Site - 219-289-3745
- Lines: 40
-
- jpr@jpradley.jpr.com (Jean-Pierre Radley) writes:
-
- >In article <1992Aug12.222706.23021@mccc.edu> pjh@mccc.edu (P. J. Holsberg) writes:
- >>Callers who use non-Telebit modems report having to hit <Enter> upwards
- >>of a dozen times before getting a "login:" prompt when they call my WB.
- >>Its registers look like this:
- >>
- >>S000:1 S001=0 S002=43 S003=13 S004=10 S005=8 S006=2 S007=40
- >>S008=2 S009=6 S010=14 S011=70 S012=50 S018=0 S025=5 S026=1
- >>S038=0 S041:1 S045:255 S046=0 S047:20 S048=0 S050=0 S051:254
- >>S056=17 S057=19 S058:0 S059=0 S060=0 S061:0 S062=15 S063=0
- >>S064:1 S068=255 S069=0 S090=0 S092:1 S093=8 S094=1 S100=0
- >>S104=0 S105=1 S111:30 S112=1 S151=4 S155=0 S180:3 S181=1
- >>S183=25 S190=1 S191=7 S253=10 S254=255 S255=255
- >>
- >>What have I got set wrong? (AT&T SV/386 R3.2.2)
-
- Here are my registers:
-
- WorldBlazer - SA - Version LA5.01A- Active Configuration
- B1 E1 L1 M1 P Q2 V1 X0 Y0
- &C1 &D3 &G0 &J0 &L0 &Q0 &R3 &S1 &T5 &X0
- S000:1 S001=0 S002=43 S003=13 S004=10 S005=8 S006=2 S007:80
- S008=2 S009:12 S010=14 S011=70 S012=50 S018=0 S025=5 S026=1
- S038=0 S041:1 S045=0 S046=0 S047=4 S048=0 S050=0 S051:6
- S056=17 S057=19 S058:2 S059=0 S060=0 S061:0 S062=15 S063=0
- S064=0 S068=255 S069=0 S090=0 S092:1 S093=8 S094=1 S100=0
- S104=0 S105=1 S111:30 S112=1 S151=4 S155=0 S180=2 S181=1
- S183=25 S190=1 S191:6 S253=10 S254=255 S255=0
-
- I lock the DTE at 38400 and let the modem "downshift" to the
- caller -- so all communications between the computer and
- modem are at 38400 baud
-
- when callers connect - the don't need to do a thing as they
- are greeted with a "login:" prompt immediately
-
- --
- Larry Snyder