home *** CD-ROM | disk | FTP | other *** search
-
- Report = 1505 Program = FITR.EXE MKT1.0 11/30/90
-
- A DESIGN THAT FITS, SUBSEQUENTLY FAILS TO FIT WHEN SOME LOGIC IS REMOVED.
-
- ---------------------------------------------------------------------------
- Report = 1580 Program = FITR.EXE MKT1.0 12/29/90
-
- PIN AND NODE EQUATIONS THAT ARE BOTH DEFINED WITH FIXED PLACEMENT DATA TO BE
- INSERTED INTO THE SAME MACROCELL BUT ARE NOT PAIRED WILL NOT BE PLACED IN
- THE SAME MACROCELL.
-
- ---------------------------------------------------------------------------
- Report = 1651 Program = FITR.EXE MKT1.0 1/22/91
-
- FITR GIVES INTERNAL ERROR "STACK OVERFLOW PUSH" WHEN MINIMIZE_OFF IS INVOKED
- ON AN EQUATION WITH 256 PRODUCT TERMS.
-
- ---------------------------------------------------------------------------
- Report = 1653 Program = FITR.EXE Rev1.F 1/22/91
-
- AN OUTPUT EQUATION WITH THE .TRST = GND GIVES ERROR F650 - INTERNAL ERROR
-
- ---------------------------------------------------------------------------
- Report = 1681 Program = FITR.EXE Rev1.F 1/22/91
-
- A DESIGN FILE WITH .CLKF = GND CAUSES THE SYSTEM TO LOCK-UP WITH THE
- MESSAGE: "INVALID DISK CHANGE WRITING DRIVE C"
-
- ---------------------------------------------------------------------------
- Report = 1687 Program = FITR.EXE Rev1.F 1/25/91
-
- A DESIGN FILE WITH A REGISTERED OUTPUT PLUS .CLKF EQUATION, BUT NO .SETF AND
- .RSTF EQUATIONS DOES NOT ISSUE A WARNING INDICATING THE MISSING EQUATIONS.
-
- ---------------------------------------------------------------------------
- Report = 1616 Program = MAINMENU.EXE MKT1.0 12/13/90
-
- ON CGA SCREENS THE SCREEN SCROLL IS EXTREMELY SLOW.
-
- ---------------------------------------------------------------------------
- Report = 1625 Program = MAINMENU.EXE MKT1.0 01/18/91
-
- THE DRIVER FOR EPSON-FX80 DIDN'T WORK WITH EPSON-SX86 & EPSON-SX185
- PRINTERS. PRINTERS ARE RESET, BUT NOTHING WAS PRINTED.
- WORKAROUND: CHOOSE IBM PROPRINTER AND IT PRINTS.
-
- ---------------------------------------------------------------------------
- Report = 1449 Program = MERGEPDS.EXE MKT1.0 11/12/90
-
- COMPAQ 286 PORTABLE MONOCHROME SCREEN, THE MENU UNDER MERGE MENU BAR ARE
- HIGHLIGHTED IMPROPERLY, & CURSOR LINE IS NOT VISIBLE. MENUS ARE COMPLETELY
- REVERSE VIDEO, INSTEAD OF THE CURSOR LINE ONLY. FIRST SUBMENU IS SAME
- WAY,BUT 2ND IS OK.
-
- ---------------------------------------------------------------------------
- Report = 653 Program = MINIMIZE.EXE ALPHA2 07/27/90
-
- PC MACHINE CRASH DURING MINIMIZE WITH FILE CONTAINING 26 SIGNALS IN 1
- EQUATION.
-
- ---------------------------------------------------------------------------
- Report = 1346 Program = MINIMIZE.EXE MKT1.0 10/10/90
-
- FILE CONTAINING A SINGLE LARGE EQUATION (IE. 256 PRODUCT TERMS), MINIMIZE
- WILL GIVE ERROR SYSTEM ERROR 27 ALLOCATING A MEMORY BLOCK GREATER THAN 64K.
-
- ---------------------------------------------------------------------------
- Report = 1396 Program = MINIMIZE.EXE MKT1.0 10/30/90
-
- DESIGN FILE WITH AN EQUATION HAVING 99 PRODUCT TERMS PRODUCES A RUNTIME
- ERROR WITH GATE SPLITTING ENABLED.
-
- ---------------------------------------------------------------------------
- Report = 1319 Program = NET2PDS.EXE MKT1.0 10/05/90
-
- AN EXTRA NODE IS ALLOCATED WHEN A REGISTER OUTPUT IS SEPARATED FROM A
- TRISTATE INPUT BY A BUFFER.
-
- ---------------------------------------------------------------------------
- Report = 1266 Program = PC2.EXE MKT1.0 09/29/90
-
- COMMUNICATIONS SOFTWARE (PC2.EXE) DOES NOT WORK WITH THE UNISITE PROGRAMMER.
-
- ---------------------------------------------------------------------------
- Report = 1680 Program = PLDSIM.EXE Rev1.F 02/15/91
-
- IN A DESIGN FILE THAT USES A CLOCKED OUTPUT TO CONTROL THE TRI-STATE OF
- OTHER OUTPUT EQUATIONS RESULTS IN WRONG JEDEC TEST VECTOR OUTPUT. PLDSIM
- GENERATE H'S OR L'S INSTEAD OF 1'S OR 0'S WHEN THE TRI-STATE CHANGES FROM
- INPUT TO OUTPUT ON THE VECTOR THAT CONTAINS THE CLOCKED CONTROL SIGNAL.
-
- ---------------------------------------------------------------------------
- Report = 1682 Miscellaneous 02/18/91
-
- UNISITE DOESN'T SUPPORT TEST AND PRELOAD "B" VECTORS
-
- ---------------------------------------------------------------------------
- Report = 1673 Miscellaneous MKT1.0 01/28/91
-
- ALL COMPUTERS WITH CHARGE CARD, A MEMORY MANAGEMENT CARD, CAUSES PALASM 4 TO
- EITHER HANG OR GET A ZMALLOC ERROR. IF CHARGE CARD IS DISABLED, PALASM 4
- RUNS WITH NO PROBLEMS.