  1. 001 Positive tolerance must be >=0.0... press RETURN
  2. 002 Negative tolerance must be <=0.0... press RETURN
  3. 003 Lines are parallel... press RETURN
  4. 004 Arc is not in viewing plane... press RETURN
  5. 005 Aspect must be > .01 and < 100... press RETURN
  6. 006 Scale must be greater than zero... press RETURN
  7. 007 Text height must be > .00005 and < 10000 ... press RETURN
  8. 008 Dimension value must be > 0... press RETURN
  9. 009 Cannot create dimension with specified data... press RETURN
  10. 010 Cannot create more than 50 ordinate dimensions... press RETURN
  11. 011 Cannot move base ordinate dimension... press RETURN
  12. 012 Cannot create duplicate ordinate dimensions... press RETURN
  13. 013 Selected dimension has no arrowheads... press RETURN
  14. 014 Selected dimension has no witness lines... press RETURN
  15. 015 Cannot put a tolerance on selected dimension... press RETURN
  16. 016 Cannot open text file... press RETURN
  17. 017 Out of space, text file not created... press RETURN
  18. 018 Please select a NOTE entity... press RETURN
  19. 019 Not enough memory for arrow %s, using default...press RETURN
  20. 020 Not enough memory for arrow %s, using default...press RETURN
  21. 021 Cannot find file (%s) ... press RETURN
  22. 022 Math error while calculating cross hatch ... press RETURN
  23. 023 Out of memory, could not build hatch ... press RETURN
  24. 024 Database error, could not add hatch entity ... press RETURN
  25. 025 No entities selected ... press RETURN
  26. 026 Bad data in hatch ... press RETURN
  27. 027 Incomplete island in hatch ... press RETURN
  28. 028 User interrupt stopped hatching ... press RETURN
  29. 029 Elbow point must be inside circle ... press RETURN
  30. 030 The line must not be normal to the construction view ... press RETURN
  31. 031 Current view is not saved in the database ... press RETURN
  32. 032 Database problems while checking id list ... press RETURN
  33. 033 Database problems while adding newly selected entities ... press RETURN
  34. 034 No drawing instances to modify ... press RETURN
  35. 035 Scale must be > 0 ... press RETURN
  36. 036 Function disabled in layout mode ... press RETURN
  37. 037 Function not available ... press RETURN
  38. 038 Error initializing layout mode, load a new one ... press RETURN
  39. 039 Labels can have a maximum of 5 arrowheads... press RETURN
  40. 040 No entities available to create layout... press RETURN
  41. 041 Model geometry is needed to use this function... press RETURN
  42. 042 Not enough memory for copying layout ... press RETURN
  43. 043 Unable to allocate memory for copying layout ... press RETURN
  44. 044 Cannot find layout to copy, select another ... press RETURN
  45. 045 Cannot copy layout entity ... press RETURN
  46. 046 Error copying layout and entities... press RETURN
  47. 047 A drawing view must be active... press RETURN
  48. 048 Unable to allocate memory for deleting layout ... press RETURN
  49. 049 Cannot mix layout and instance geometry ... press RETURN
  50. 050 Labels can have a maximum of 5 arrowheads... press RETURN
  51. 051 Error in layout function (%s)
  52. 052 No entities found in current layout ... press RETURN
  53. 053 Instance geom. not available for this function ... press RETURN
  54. 054 Maximum number of (%d) instances reached ... press RETURN
  55. 055 Maximum number of (%d) layouts reached ... press RETURN
  56. 056 Cannot trim/extend instance-specific splines ... press RETURN
  57. 057 Cannot trim/extend instance-specific polylines ... press RETURN
  58. 058 Cannot perform undo since sequence number modified ... press RETURN
  59. 059 Error! no bend in leaders (try REGULAR radial)... press RETURN
  60. 060 Scales of the two instances must be the same... press RETURN
  61. 061 Rotation angle must be >= -360 and <= 360... press RETURN
  62. 062 Invalid Data! Bent dimension would be incorrect... press RETURN
  63. 063 Not enough memory to modelize entities! ... press RETURN
  64. 064 Cannot edit file based notes...  press RETURN
  65. 065 Elbow point coincides with another elbow point ... press RETURN
  66. 066 A drawing view cannot be active ... press RETURN
  67. 067 Cannot chamfer line normal to current view ... press RETURN
  68.