home *** CD-ROM | disk | FTP | other *** search
/ Piper's Pit BBS/FTP: ibm 0330 - 0339 / ibm0330-0339 / ibm0333.tar / ibm0333 / ALFIEDOS.ZIP / README.TXT < prev   
Encoding:
Text File  |  1993-03-02  |  10.0 KB  |  195 lines

  1.                         Thank you for buying ALFIE-IT.
  2.                Version 4.02 offers several new helpful features
  3.  
  4.  
  5. CANNED MESSAGES: To save time typing redundant messages create canned messages.
  6.  
  7.           To use or create a CANNED MESSAGE simply enter ALFIE-IT, select
  8.           a MEMBER or GROUP like normal, and press <ENTER>, to get in the
  9.           MESSAGE Window.  Once you are in the MESSAGE Window press the
  10.           <F2> key to bring up the 30 canned messages. To change a canned
  11.           message, place the cursor over the message to be edited and begin
  12.           changing it. To select a canned message place the cursor over the
  13.           desired message and press <ENTER>. This will bring the CANNED
  14.           MESSAGE into the MESSAGE Window, and can be used like any normal
  15.           message you type in manually. The CANNED MESSAGE will OVERWRITE 
  16.           any text that you type in the MESSAGE WINDOW before using <F2> and
  17.           you can add text after bringing in the CANNED MESSAGE.
  18.  
  19.           Note: The canned message file is updated only when changes are made
  20.                 while exiting from <F2>(CANNED MESSAGES).
  21.  
  22.  
  23. DIRECT CONNECT: For cellular phones
  24.  
  25.           Now you can send messages from your cellular phone while on the road.
  26.           Set your phone line type in ALMODCON.EXE to CELLU. This selection
  27.           will put ALFIE-IT in the cellular dial mode.
  28.  
  29.            NOTE: While we have tested this mode in fringe coverage areas at
  30.                  2400 baud with good results we suggest setting your
  31.                  baud rate to 300 while in the direct connect mode.
  32.  
  33.    ******* PLEASE DO NOT DRIVE AND SEND MESSAGES AT THE SAME TIME **********
  34.  
  35.  HOW IT WORKS.
  36.                1. Plug your modem into your cellular phone RJ-11 JACK.
  37.                   (Not all cellular phones come standard with this option)
  38.                2. Run ALFIE-IT and enter your messages like normal
  39.                3. Look in the modem status box and follow the prompts.
  40.                    e.g.  DIAL 555-1212
  41.                4. Dial the number on your cellular phone like any other call.
  42.                5. As soon as you hear the PAGER CENTRAL COMPUTER answer the
  43.                   call press the <ENTER> key on your computer or you can
  44.                   "BAIL OUT" by pressing the <ESC> key.
  45.                6. The modem status box will display ESTABLISHING CONNECTION
  46.                7. Once the computers "CARRIER UP" the message is sent normally.
  47.                8. When the call is completed the modem status will tell you
  48.                   to hang up your cellular phone.
  49.  
  50.           Note: All of the ALFIE-IT features work with direct connect like
  51.                 group calls, multiple pager centrals, etc.
  52.  
  53. AUTO BAUD RATE: (Correction to  PAGE 16 for MODEM BAUD RATE)
  54.           Now you can set the baud rate in ALMODCON.EXE to the baud rate of
  55.           your modem instead of the paging central baud rate. ALFIE-IT will
  56.           automatically send the messages at the fastest speed your paging
  57.           company will allow. Setting the baud rate faster will also load
  58.           ALFIE-IT faster.
  59.                NOTE: If you get an E15 or E26  error for any reason try setting
  60.                      almodcon to 300 baud and retry. If you still get the
  61.                      error read the MODEMS section in this README file
  62.                      and locate your modem manual before calling for
  63.                      tech support.
  64.  
  65. FASTER MODEM INITIALIZATION
  66.           Our DEEP modem initialization has made the ALFIE-IT line of products
  67.           VERY DEPENDABLE,  However, We wanted to speed-it-up too! So we did.
  68.           If you need to send special commands to your modem you can use the
  69.           secondary init string from command line.  Many communication programs
  70.           send commands to the modem and expect that the modem is there. It is
  71.           possible that your communications/terminal program will run with your
  72.           modem and yet ALFIE returns an E15. This is usually due MNP hardware
  73.           compression of todays modems. SEE MODEMS in this README file.
  74.  
  75.  
  76. SECONDARY INIT STRING
  77.           To send a secondary modem init string USE the following
  78.               e.g.   ALFIE-IT /ATxxxxxx     Where xxxxx is your init string.
  79.                                          DO NOT LEAVE ANY SPACES AFTER THE AT.
  80.  
  81. COMMAND LINE PAGING
  82.          If you want to speed page you can enter data directly from the
  83.          COMMAND line using the following format:
  84.              e.g    ALFIE-IT [ACCOUNT_NUMBER] [MESSAGE]
  85.          This option uses the default pager central set in ALMODCON.
  86.  
  87.  
  88. <NOTES>**********************************************************************
  89.  
  90. ACCOUNT NUMBER: Just what is it?
  91.  
  92.           There is no industry wide used standard for this term yet.
  93.           ACCOUNT NUMBER = PIN NUMBER = GHOST NUMBER = ID NUMBER
  94.           = ALHPA NUMBER = PAGER NUMBER
  95.           This number can be a 1 to 7 digit number
  96.           If you have any further questions on this please call us.
  97.  
  98.  
  99. ALFIE-IT:
  100.           When in the Member/Group window you can find your member or group by
  101.           using our "DUCK HUNT" by pressing the first letter of the name A-Z.
  102.           Want to send the same message to several members??  Use <ALT><L>.
  103.  
  104. ALMODCON: (System SETUP)
  105.           Now you can automatically personalize all your pages with MESSAGE ID.
  106.           Great for multiple locations, where did my page come from ?? EVTEK?
  107. MONO MODE If the programs do not present well on your mono, LCD, or plasma
  108.           display then run ALMODCON /M to turn on MONO mode and then <SAVE>.
  109.  
  110. ALMEMBER: (Adding Members/Building Groups)
  111.           Group building made even easier in Member Assembler.  The <TAB> key
  112.           works from both the GROUP WINDOW or MEMBER WINDOW so assemble away.
  113.           Want to sort your groups and/or members??  No problem, use <ALT><S>.
  114.  
  115.  
  116. <HOT KEY FOR DOS>*******************************************************************
  117.  
  118.         DUCKIEUP.EXE is a very powerful utility that allows you to "POP" up
  119.      ALFIE-IT. from within another DOS program.  When your finished DUCKIE-UP
  120.      will restore everything, placing you right back where you left off!
  121.      To run the "HOT KEY" from the C:> type CD\ALFIE  and press ENTER
  122.                                        type DUCKIEUP  and press ENTER
  123.  
  124.   To "POP" up  ALFIE-IT. simply press <Left Tab>and<Left Alt> at the same time.
  125.  
  126.       NOTE:    If you want to load the "HOT KEY" when your system boots up
  127.                       then add the above lines into your autoexec.bat.
  128.                If you need to remove the "HOT KEY" Feature from memory.
  129.                       from the C:> type DUCKIEUP /U and press ENTER.
  130.                For Additional Help type DUCKIEUP /H and read the displayed
  131.                       information on custom setups.
  132.  
  133.       System                 DOS 3.0 or higher, Network Compatible
  134.       Requirements           uses less than 7K of memory
  135.       for DUCKIEUP.EXE       uses less with EMS
  136.                              without EMS requires 700k of disk space to swap.
  137.  
  138. <MODEMS>**********************************************************************
  139.  
  140. A NOTE ON MODEMS:
  141.   Not every Duck is the same.  This is also true in modems.
  142.   Many 9600/14.4 baud modems power up in a MNP hardware compression mode as
  143.   a power up default and you may have to set the modem to run in asynchronous
  144.   mode. We have added a secondary Modem INIT string to allow you to adjust
  145.   alfie for your modem. If you are not sure where your modem is SEE <TEST>
  146.  
  147.  
  148. I GET THIS ERROR Exx: WHAT SHOULD I DO..............  WRITE IT DOWN  (Exx:)!!
  149.  
  150.    E15: E15a,b,c,d...
  151.              Your paging company or one you are trying to connect with may not
  152.               support The MNP mode. ALFIE does and eventually all modems will.
  153.  
  154.       1) Your modem may be in a MNP mode.
  155.           A. Set your modem baud rate to 300 and try paging again.
  156.              If your page goes through and your paging company supports
  157.              a faster baud rate then your modem is probably using MNP
  158.                 Exit out and restart program by typing alfie /MNP, this will
  159.                 send down a &Q0 to your modem  to turn off MNP for most modems.
  160.  
  161.           B. Look in your modem manual for the code to turn off
  162.              MNP, and any other COMPRESSION, and to set the modem in a
  163.              asynchronous mode, and try using them one at a time
  164.                 Exit out and restart program by typing alfie /ATxxxxxxxxx
  165.                 use the codes from your modem manual in place of the xxx's
  166.                 This code is sent as a second modem init string to your modem.
  167.  
  168.           NOTE: Not every modem uses the same codes even though they are
  169.                 Hayes compatible modems. IF THE ABOVE SUGGESTIONS DO NOT SOLVE
  170.                 YOUR PROBLEM THEN locate your modem manual and Give us a call.
  171.                 We will be happy to help you with MNP.
  172.    E26: E26a,b,c,xx
  173.          A time out condition exists. ALFIE was waiting for data to come in
  174.          and no data came in from the modem, or pager central.
  175.  
  176.    E28: The central failed to accept your message for the following reasons:
  177.            A) Check for incorrect ACCOUNT# (PIN) number.
  178.            B) Check the ACCOUNT# (PIN) number correspond with  CENTRAL NUMBER.
  179.            C) Check your message length, is it to long?
  180.            D) It is possible that there was a noisy phone line corrupting data.
  181.         Try sending a short message e.g."HELLO" before calling tech support.
  182.  
  183.  
  184. <TEST>************************************************************************
  185.  
  186.  Find your modem:
  187.         ALFIE has a TEST program on the 3-1/2 720k disk to find and test
  188.         your modem:
  189.         To use the test Type COMQUAK2  and the test will find your modem.
  190.  
  191.  
  192. ******************************************************************************
  193.          Please find your modem operators manual before calling .
  194.                                 1-800-388-8499
  195.                              Tech Hrs 8am-5pm EST