home *** CD-ROM | disk | FTP | other *** search
/ Sound, Music & MIDI Collection 2 / SMMVOL2.bin / DRIVER / S2K0314A.ZIP / S2K0314A.EXE / README.TXT < prev    next >
Encoding:
Text File  |  1995-03-13  |  11.4 KB  |  248 lines

  1. Soundscape S-2000 Release Notes
  2.  
  3. Date: 03/12/95
  4. Version: 1.30.00  (BETA)
  5.  
  6. ******************************************************************************
  7. * NOTICE:  THIS SOFTWARE IS BETA AND IS NOT CURRENTLY SUPPORTED BY ENSONIQ.  *
  8. *          If you have any problems installing or using this software please *
  9. *          send e-mail to soundscape-bugs@ensoniq.com.  We will not be taking*
  10. *          phone calls to support this version until it is released.  Be sure*
  11. *          to include copies of any relevant files (AUTOEXEC, CONFIG.SYS,    *
  12. *          SYSTEM.INI                                                        *
  13. *                                                                            *
  14. ******************************************************************************
  15.  
  16. --------------------------------------------------------------------------------------------------------------------------------
  17. Troubleshooting Information
  18. --------------------------------------------------------------------------------------------------------------------------------
  19. For up-to-date automated troubleshooting assistance, please call Ensoniq's
  20. Fax-on-Demand service at 1-800-257-1439 from a touch-tone telephone.  
  21. This service requires that you have access to a FAX machine.   Please request
  22. document #7255 (Trouble Shooting Manual).
  23.  
  24. --------------------------------------------------------------------------------------------------------------------------------
  25. v 1.30.00 BETA
  26. --------------------------------------------------------------------------------------------------------------------------------
  27. **Installation**
  28. The uninstall program will now check for the SNDSCAPE environment variable
  29. before running.  If it is not present, the uninstall will not run.  This
  30. will prevent the program inadvertently deleting files.
  31.  
  32. The Windows directory is now copied to your SNDSCAPE.INI file.
  33.  
  34. **SSInit**
  35. SSInit now needs to know where your Windows directory is located.  If it can not
  36. find it, SSInit will prompt you to enter your current Windows directory.
  37.  
  38. **SSCD.SYS**
  39. The SSCD program uses new command line arguments.  The previous version uses
  40. the Port= argument to find the Soundscape base address.  The new version uses
  41. /B:<base address>.  This is the only argument in SSCD.
  42.  
  43. **Makeboot**
  44. There is a generic makeboot utility that will create a boot disk to initialize
  45. the Soundscape card.  If you need to create a boot disk it is recommended that
  46. you use this utility.
  47.  
  48. **Windows**
  49. There is a new Windows driver included in this release.  This new driver allows
  50. DOS games to run in a DOS Box under Windows, it will also fix any problems
  51. associated with application authored with the Director.
  52.  
  53. The driver has an on-line help associated with it.  Please consult the on-line help
  54. for questions regarding configuring the driver.
  55.  
  56. To access the driver setup, Open the Control Panel and double click the Soundscape
  57. icon.
  58.  
  59. **Audiostation**
  60. Their is a new version of Audiostation (1.78) that fixes incompatibilities
  61. with some CD-ROM brands.
  62.  
  63. --------------------------------------------------------------------------------------------------------------------------------
  64. v 1.25.00
  65. --------------------------------------------------------------------------------------------------------------------------------
  66. **OS/2 Support**
  67. OS/2 Support has been implemented in this release.  The OS/2 drivers as well
  68. as a README can be found on disk 2.
  69.  
  70. **Installation**
  71.  
  72. **Firmware**
  73. The Sound Blaster emulation is now 2.0 compatible.  This fixes games that only
  74. support SoundBlaster 2.0 or higher (Cyberia, Creature Shock).  It also will
  75. clean up games that try to simulate the auto-restart capabilities of a Sound
  76. Blaster 2.0 on earlier Sound Blaster models (i.e., Rebel Assault).  In some
  77. games, it may be necessary to select Sound Blaster Pro to take advantage of
  78. the additional 2.0 functions.
  79.  
  80. **SSInit**
  81. The SSInit Exit dialog is more intuitive . Now, the only choices in the Exit
  82. dialog are Accept or Discard changes.  In previous versions, when invoked,
  83. SSInit would read in the current settings from the card and display the
  84. Quick Setup dialog.  Then if the user selected Advanced it would discard any
  85. changes made on this dialog and reload all the values from the SNDSCAPE.INI
  86. file.  This has been a source of confusion for our customers.  In this version,
  87. all settings are obtained from the SNDSCAPE.INI file and if the user selects
  88. "Accept", upon exit the changes are written back out to the INI file.  If the
  89. user selects "Discard," no changes are saved and the Soundscape card will be
  90. left in the same state as when SSInit was invoked.
  91.  
  92. Detection of the Wave Port and Base Port is now done when SSInit is invoked OR
  93. anytime you exit the Hardware settings page.  If either port fails detection,
  94. SSInit will put the user back into the Hardware page. The user can then change
  95. the Port and select OK or select Cancel to abort any changes.
  96.  
  97. **MT32 Utility**
  98. The MT32 program will now set the Soundscape card to MT32 mode when invoked
  99. without any arguments.
  100.  
  101. Example:
  102.     MT32       <- Sets the Soundscape card to MT32 mode
  103.     MT32 ON    <- Sets the Soundscape card to MT32 mode
  104.     MT32 OFF   <- Sets the Soundscape card back into the default (General MIDI) mode.
  105.  
  106.  
  107. --------------------------------------------------------------------------------------------------------------------------------
  108. v 1.20.04
  109. --------------------------------------------------------------------------------------------------------------------------------
  110. **Installation**
  111. Added a test for the PCI bus that will detect when the installation program is
  112. first run if a PCI bus is installed in the system.  If a PCI bus is detected,
  113. the installation program will ask the user if they wish to reconfigure their
  114. interrupts to facilitate the PCI bus. (See Installation Notes 1.20.03 below).
  115.  
  116. **Firmware**
  117. The Soundscape firmware files SNDSCAPE.CO0 and SNDSCAPE.CO1 are now 
  118. generic.  This means that they can be used with all OEM versions of Ensoniq
  119. Soundscape.  The impact of the generic firmware on the original OEM boards is
  120. that use of the TDA8421 tone controller chip has been disabled.  This was done
  121. because of increased code space as well as to facilitate faster development.
  122.  
  123. **SSInit**
  124. The SSInit interface is now the same for all Soundscape OEM boards.  This can
  125. be seen by bringing up the mixer.
  126.  
  127. The DMA test failed on some systems in v1.20.03.  It has been fixed in this
  128. release.
  129.  
  130.  
  131. **VSB**
  132. Because of our changes in our Sound Blaster emulation code the following
  133. files are no longer needed:
  134.    VSB_EMM.COM
  135.    EMM386.EXE
  136.    MAKEBOOT.EXE
  137. These can be removed from your Soundscape directory.
  138.  
  139. **Windows Drivers**
  140. The Windows Driver is now generic.  To use it with OEM boards with the TDA8421, you must insert the line IsDvb=1 in the [sndscape.drv] section of your SYSTEM.INI file.  If necessary, this is done at boot time.
  141.  
  142. The compatibility problem with programs authored with the Directory v4.x
  143. has been fixed.
  144.  
  145.  
  146. --------------------------------------------------------------------------------------------------------------------------------
  147. v 1.20.03
  148. --------------------------------------------------------------------------------------------------------------------------------
  149. **Installation**
  150. When you first run the installation program it will display a dialog
  151. asking you if you have a PCI BIOS.  If you have a PCI BIOS or are unsure 
  152. then you should change your default MIDI IRQ.  In most cases IRQ 10 is a
  153. safe choice.
  154.  
  155. **Compatibility Note** 
  156. Some older DOS programs (usually games) do not allow you to specify an 
  157. alternate IRQ and assume IRQ 2/9.  If you have any software that does this 
  158. then you will need to make a change in your BIOS.  Typically, the PCI BIOS 
  159. allows you to allocate one or more IRQs for use with either the PCI bus or 
  160. the ISA bus.  By default, many of the BIOSs use IRQ 9 as the PCI IRQ.  To 
  161. resolve a conflict you must tell the PCI BIOS to use a different IRQ.
  162.  
  163. This can generally be accomplished by going to the PCI settings screen of
  164. the BIOS setup program.  Once there, most setup programs give you a set of
  165. IRQs that can be switched between the PCI bus and the ISA bus.  The basic
  166. idea is to set IRQ 9 to the ISA bus and while each manufacturer may 
  167. implement this differently the common selections are:
  168.  
  169. IRQ 9        ISA/PCI
  170. IRQ 9        Available/Used -> where Used allocates the IRQ to the ISA 
  171.                               bus.
  172. IRQ 9        Free/Used      -> where Used allocates the IRQ to the ISA
  173.                               bus.
  174.  
  175. For additional information consult the BIOS documentation that comes with
  176. your PC.
  177.  
  178.  The software will remove any previous reference in your AUTOEXEC.BAT of
  179. the following:
  180.     SSINIT
  181.     SNDSCAPE environment variable
  182.     BLASTER environment variable
  183.  
  184. It will then place the new Soundscape startup information at the TOP of your 
  185. AUTOEXEC.BAT.  
  186.  
  187. **Firmware**
  188. The software now addresses the MIDI volume problem that was present 
  189. in v1.20.0x.
  190. In earlier versions of 1.20.0x if the synth volume was set to 0 occasionally 
  191. you would hear buzzing from the synthesizer.
  192.  
  193. The MIDI routing bug in 1.20.0x has been fixed.
  194. In earlier versions of 1.20.0x the ability to use an external synthesizer from
  195. DOS was not implemented correctly.
  196.  
  197. --------------------------------------------------------------------------------------------------------------------------------
  198. v1.20.02
  199. --------------------------------------------------------------------------------------------------------------------------------
  200. **Installation**
  201. Installation program will now check for a previous CD-ROM install.
  202. If it detects Soundscape CD-ROM drivers in your CONFIG.SYS or AUTOEXEC.BAT 
  203. it will not overwrite them.
  204.  
  205. **SSInit**
  206. SSInit now downloads both the General MIDI firmware and the FM firmware.  
  207. Previous versions of Soundscape software required the Soundscape card
  208. to be redownloaded when switching between GM and FM mode.  This is no longer 
  209. necessary.
  210.  
  211. The SSInit command-line interface has changed.  To initialize the Soundscape
  212. card type SSINIT /I.  This is done at boot-up time.
  213.  
  214. The Hardware Test page has changed.  To Test your current hardware
  215. settings select Hardware Tests, then select either IRQ or DMA Test.  These
  216. tests will show conflicts with the current hardware settings.  If there is a
  217. conflict, it can be resolved by making changes on the Hardware Settings page
  218. in SSInit.
  219.  
  220. The Synth Settings screen has been removed.
  221.  
  222. A MIDI Settings screen has been added to SSInit.  Under DOS MIDI data can go 
  223. to either the internal synth or the external MIDI port. The MIDI settings 
  224. screen allows you to route your MIDI data to either the Internal Synth or
  225. External MIDI port.  The default for the MIDI routing is the Internal 
  226. Synthesizer.
  227.  
  228. **MT32**
  229. A new utility has been added to allow switching between the General MIDI patch
  230. set and the MT32 patch set.  To switch between the patches you need to run 
  231. the MT32 command.  The arguments for MT32 are as follows:
  232.  
  233. MT32 [ ON | OFF ] [ /? ]
  234. Where ON switches to the MT32 patch set, OFF switches to the General MIDI set.
  235. MT32 without any arguments returns the current patch set.
  236.  
  237.  
  238. **Firmware**
  239. The intermittent noise that was present in the 1.20.0x Sound Blaster emulation
  240. has been eliminated. 
  241.  
  242. **Windows**
  243. SSINITGM.DLL has changed to handle the new firmware.
  244.  