home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1993 #3 / NN_1993_3.iso / spool / misc / consumer / house / 17431 < prev    next >
Encoding:
Internet Message Format  |  1993-01-28  |  2.0 KB

  1. Path: sparky!uunet!portal!lll-winken!uwm.edu!spool.mu.edu!olivea!decwrl!pacbell.com!att-out!walter!porthos!dasher!patter
  2. From: patter@dasher.cc.bellcore.com (patterson,george r)
  3. Newsgroups: misc.consumers.house
  4. Subject: Re: Insulating above a finished attic
  5. Message-ID: <1993Jan26.172650.29284@porthos.cc.bellcore.com>
  6. Date: 26 Jan 93 17:26:50 GMT
  7. References: <eric.728015238@milton>
  8. Sender: netnews@porthos.cc.bellcore.com (USENET System Software)
  9. Organization: Bellcore, Livingston, NJ
  10. Lines: 33
  11.  
  12. In article <eric.728015238@milton> eric@milton.u.washington.edu (Eric Hirst) writes:
  13.  
  14. >The primary options, then, are:
  15. >
  16. >1. Stuff in the fiberglass, paper side down, and hope for the best.  Maybe
  17. >increase ventilation in crawl spaces.
  18.  
  19. First off, Reader's Digest is correct (this time). Any moisture that
  20. might condense in the affected roof are will gravitate to those crawl
  21. spaces and evaporate. Increased ventilation in the crawl spaces can't
  22. hurt.
  23.  
  24. You will have a problem "stuffing" the FG in because of roofing nails
  25. sticking down through the roof. I would recomend that you work from the
  26. top, if you can get in there. Cut some pieces of plywood to use as
  27. pushers (say, 9" or 12" wide), and work with one of these on top of the
  28. insulation. You can press the FG down far enough with one of these to
  29. clear the nails. This will also leave enough air gaps between the
  30. insulation and the roof to provide more than adequate ventilation.
  31.  
  32. I did exactly this (actually, my push sticks were 2x4s) a few years ago
  33. in my attic bedroom.
  34.  
  35. An alternate (and better) method of getting the stuff in there is to
  36. remove the sheet rock, insulate, and re-rock, but this is not for the
  37. faint hearted.
  38.  
  39. -----------------------------------------------------------------------
  40.                     | There are very few personal problems which
  41. George Patterson -  | cannot be solved by a suitable application
  42.                     | of high explosive.
  43.                     |
  44. -----------------------------------------------------------------------
  45.