home *** CD-ROM | disk | FTP | other *** search
- Path: sparky!uunet!gatech!paladin.american.edu!howland.reston.ans.net!usc!news.service.uci.edu!unogate!mvb.saic.com!carpenter
- From: Carpenter@Fwva.Saic.Com (Apprentice Wizard)
- Newsgroups: comp.os.vms
- Subject: Re: Problem with LaserJet 4M attached via terminal server
- Message-ID: <10305352@MVB.SAIC.COM>
- Date: Mon, 25 Jan 1993 16:12:59 GMT
- References: <1993Jan22.220914.2118@news.vanderbilt.edu>
- Organization: Science Applications Int'l, Corp. - Computer systems operation
- Lines: 63
-
- DALEP@ctrvax.Vanderbilt.Edu (Dale Plummer) writes:
- >I am having a problem with a HP LaserJet 4 M printer connected to
- >a DECserver 200 terminal server. The system is a VAXstation 3100
- >running VMS v5.3. Using the set up described below, I can print
-
-
- These settings work fine for my HP 4 and postscript files:
-
- Terminal: _LTA113: Device_Type: FT4 Owner: SYMBIONT_0002
- Username: SYSTEM
-
- Input: 9600 LFfill: 0 Width: 240 Parity: None
- Output: 9600 CRfill: 0 Page: 66
-
- Terminal Characteristics:
- Interactive Echo Type_ahead No Escape
- Hostsync TTsync Lowercase Tab
- Wrap Scope No Remote Eightbit
- No Broadcast No Readsync No Form Fulldup
- No Modem No Local_echo No Autobaud No Hangup
- No Brdcstmbx No DMA No Altypeahd No Set_speed
- Line Editing Insert editing No Fallback No Dialup
- No Secure server No Disconnect Pasthru No Syspassword
- No SIXEL Graphics No Soft Characters No Printer Port Numeric Keypad
- ANSI_CRT No Regis No Block_mode Advanced_video
- No Edit_mode DEC_CRT DEC_CRT2 DEC_CRT3
- No DEC_CRT4
-
- Device spooled to _LEANVA$DUA0:
-
- Terminal queue OPENLASER, on LEANVA::LTA113:, mounted form DEFAULT
- <HP 4 Laser Printer Paul Van Doren's Office>
- /BASE_PRIORITY=4 /BLOCK_LIMIT=(1,500) /DEFAULT=(FLAG=ONE,FORM=DEFAULT)
- Lowercase /OWNER=[SYSTEM] /PROCESSOR=LATSYM /PROTECTION=(S:RWED,O:RWED,G:RW,
- W:RW)
-
- Port 2: (Remote)
-
- Character Size: 8 Input Speed: 19200
- Flow Control: XON Output Speed: 19200
- Parity: None
-
- Access: Remote Local Switch: None
- Backwards Switch: None Name: PORT_2
- Break: Local Session Limit: 4
- Forwards Switch: ^F Type: Ansi
-
- Preferred Service: None
-
- Authorized Groups: 0- 33
- (Current) Groups: 0- 33
-
- Enabled Characteristics:
-
- Broadcast, Input Flow Control, Loss Notification, Message Codes,
- Output Flow Control, Verification
-
- =-=-=-=-=-=-==-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-==-=-=
- Scott Carpenter
- VAX Systems Manager Ya dina' tell 'im how long it'd really
- SAIC Falls Church, VA take ta fix it did ya'?
- CARPENTER@FWVA.SAIC.COM M. Scott, CAPT, SUFP
- =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
-