  1. Newsgroups: comp.sys.sun.hardware
  2. Path: sparky!uunet!mcsun!chsun!horus!raju
  3. From: raju@inso.pr.net.ch (Raju Varghese)
  4. Subject: Intermittent problems with SunCD
  5. Message-ID: <1993Jan8.143000.318@inso.pr.net.ch>
  6. Summary: Can someone help me with hardware problems with the SunCD player
  7. Keywords: cdrom, scsi
  8. Organization: IntelliSoft, Inc.
  9. Date: Fri, 8 Jan 1993 14:30:00 GMT
  10. Lines: 38
  11.  
  12. I've been using a SunCD for over a year now without problems and now
  13. it is exhibiting intermittent hardware errors. These manifest themselves
  14. with an error message (when things go well) or a system lockup (when it is
  15. nasty). I'm using a Sun SLC running 4.1.2. The SCSI chain has the following
  16. devices: SunCD, two disks and a terminated QIC tape drive.
  17.  
  18. Examples of error messages which it reports are:
  19.     vmunix: sr0: disk not responding to selection
  20.     vmunix: sr0: Unit not Ready. Additional sense code 40
  21.  
  22.     vmunix: esp0: Disconnected command timeout for Target 3 Lun 0
  23.     vmunix: sd0:    SCSI transport failed: reason 'timeout': retrying command
  24.  
  25.     vmunix: esp0: Spurious data in phase from target 2
  26.  
  27.     vmunix: sd2:    SCSI transport failed: reason 'reset': retrying command
  28.  
  29.     vmunix: sr0:    Error for command 'read'
  30.     vmunix:         Error Level: Fatal         Block: 112
  31.     vmunix:         Sense Key:   Hardware Error
  32.     vmunix:         Additional Sense key:   0x9
  33.     vmunix:         Vendor 'Sony' unique error code: 0x9
  34.     
  35.     vmunix: sr0: Unit not Ready. Additional sense code 87
  36.     
  37.  
  38. If it doesn't panic I can usually fix it by ejecting the CD and inserting it
  39. again or by twiddling the SCSI cables at the rear of the unit. I have 
  40. disconnected the cables, cleaned the connectors, cleaned the fan, and the
  41. inside. As the SCSI cables are thick and relatively inflexible, I feel that
  42. there is quite some pressure on the female connectors. Could this be the
  43. problem? It looks like a loose contact somewhere. Has anyone noticed this
  44. before?
  45.  
  46. Any help would be appreciated.
  47.  
  48. Raju Varghese raju@inso.pr.net.ch
  49.  
  50.