home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.sys.sgi
- Path: sparky!uunet!math.fu-berlin.de!informatik.tu-muenchen.de!lrz-muenchen.de!miris!andreas
- From: andreas@miris.phys.chemie.tu-muenchen.de (Andreas Lammers)
- Subject: Flexfax with MODEM ROCKWELL RC32ACL/V1.02C
- Message-ID: <andreas.726231813@miris>
- Summary: received faxes are just 100 mm in length
- Keywords: MODEM ROCKWELL RC32ACL/V1.02C Flexfax haeussler fax class2
- Sender: news@news.lrz-muenchen.de (Mr. News)
- Reply-To: andreas@miris.phys.chemie.tu-muenchen.de
- Organization: Technische Universitaet Muenchen (Germany)
- Date: Tue, 5 Jan 1993 11:03:33 GMT
- Lines: 46
-
- Dear Hackers,
-
- the new year has begun and the money is beginning to flow again. So we
- bought a modem from Haeussler. The modem says it's a ROCKWELL RC32ACL/V1.02C.
-
- I got the flexfax software from sgi.com and just after one change in the
- source-code (I had to elimiate the @ in the dial-string) the sending of faxes
- worked perfect.
-
- We just have the problem that incoming faxes are being cut after about
- 100mm. The log entry says something like
-
- Jan 5 10:10:42: [11465]: --> [7:+FET: 0]
- Jan 5 10:10:42: [11465]: RECV PPM: more pages, same document
- Jan 5 10:10:42: [11465]: start 30 second timer
- Jan 5 10:10:42: [11465]: stop timer
- Jan 5 10:10:42: [11465]: --> [2:OK]
- Jan 5 10:10:42: [11465]: <-- [6:AT+FDR]
- Jan 5 10:10:42: [11465]: start 30 second timer
- Jan 5 10:10:42: [11465]: stop timer
- Jan 5 10:10:42: [11465]: --> [14:Cí%╩ΩJ^B.\202\202jR■]
- Jan 5 10:10:42: [11465]: start 30 second timer
- Jan 5 10:10:42: [11465]: stop timer
- Jan 5 10:10:42: [11465]: --> [2:OK]
- Jan 5 10:10:44: [11465]: <-- [6:AT+FDR]
- Jan 5 10:10:44: [11465]: start 30 second timer
- Jan 5 10:10:44: [11465]: stop timer
- Jan 5 10:10:44: [11465]: --> [5:ERROR]
- Jan 5 10:10:44: [11465]: REMOTE HANGUP: Unspecified Phase C error, \\
- including too much delay between TCF and +FDR command (code 90)
- Jan 5 10:10:44: [11465]: RECV: end
- Jan 5 10:10:44: [11465]: SESSION END
-
- I know, flexfax is not originally supported by SGI, but if anyone
- has an idea, it would be really nice.
-
- Thanks
-
- Andreas
-
-
- --
- Andreas Lammers | Institut fuer Physikalische und Theroretische Chemie
- | der Technischen Universitaet Muenchen
- Tel.:(089)/3209-3444 | Lichtenbergstr. 4
- | D-8046 Garching
-