- wijkstra@fwi.uva.nl (Marcel Wijkstra (AIO)) writes:
-
- > Hi,
- >
- > I have a rather strange modem problem: I have a 1200 baud Hayes compat.
- > modem (Repko M2000trio) that I want to connect to my 386 clone.
- > I got it from a friend, who used it with a PS/2 and Procomm 2.3, which
- > worked ok.
- > However, when I attach it to my 386 with Procomm 2.4.2, it does not dial
- > any phone number properly: I can hear the (phone) dialing tone through
- > the internal speaker, waiting for a number to be dialed. But the dialing
- > itself is just a short period of (fluctiating) noise (which length is
- > proportional to the length of the phone number, so it DOES try to dial
- > something). And then of course, nothing happens.
- > With my friend's PS/2, everything still works, i.e. we can hear the
- > dialing pulses.
- > I've tried it with a 286 (Bull Micral, so no cheap clone...), but I get
- > the same negative result. Also, I've tried using Windows' (3.0 and 3.1)
- > Terminal program, but again: no luck.
- >
- > What could cause this problem? I don't suppose it's the serial cable,
- > since it is a full 25-wire one (or is it wrong to connect all 25 pins???)
- >
- > Any help would be greatly appreciated.
- >
- Bad news... guess what. If it came from a PS/2 and it is an internal modem
- it might be a MCA modem. If it is an external, and you type AT, and get
- OK back, the cable is just fine. I run 25 pin cable straight though on
- my modems.
-
- Do ATS11? and ATS9?
- One of these are going to be 55 or above. (I think it will be 11, so check
- that first). Do this : ATS11=95
-
- That will lengthen the tones to 95 ms.
-
- Also, try ATDP and see if it pulse dials and can make it out.
-
- Those are my ideas.
-
- Greg
-
- .-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.