home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.dcom.modems
- Path: sparky!uunet!spool.mu.edu!umn.edu!csus.edu!netcom.com!wolfgang
- From: wolfgang@netcom.com (Wolfgang Henke)
- Subject: Re: HELP: Digicom Scout+ and kermit
- Message-ID: <1993Jan5.075206.6468@netcom.com>
- Organization: Netcom
- X-Newsreader: Tin 1.1 PL5
- References: <C0BKK3.4EH@news.cso.uiuc.edu>
- Date: Tue, 5 Jan 1993 07:52:06 GMT
- Lines: 37
-
- Dennis Robinson (djr48312@uxa.cso.uiuc.edu) wrote:
- : Im using minix kermit 5A. For some reason it talks to my Hayes
- : optima 96 fine but does not really want to communicate with my
- : scout+. When I "connect" to the modem I seem to have to hit the
- : enter key twice to get the at command to process. On the hayes I only
- : have to hit enter once. ALso when I try to do a "at*o" I only get
- : this much info:
- :
- : MODEL:SCOUT PNE
- : &B0 &C1 &D2
-
- You seem to have a flowcontrol problem. Just looking at the regular
- AT*O output and the one you posted, it seems that many lines are just
- swallowed. The Scout+ uses hardware handshake by default. (AT*F3).
- Here is the regular AT*O printout so you can compare:
-
- at*o
- MODEL:SCOUT PLUS
- DTE: 57600 N81
- DCE: 14400 V42b
- RECEIVE LEVEL= -36 DBM
-
- E1 K1 M1 Q0 V1 X4 TONE
- &B0 &C1 &D3 &R2 &T5
- *E1 *F3 *G1 *M2 *N2 *P0 *Q3 *S1 *T1
-
- S00=001 S04=010 S08=002 S15=255
- S01=000 S05=008 S09=000 S18=000
- S02=043 S06=002 S10=003 S25=000
- S03=013 S07=090 S12=050 S26=000
- OK
-
-
- --
- _________________________________________________________________________
- Wolfgang Henke Data lanes not car pool lanes wolfgang@netcom.com
-
-