  1. Newsgroups: comp.os.ms-windows.apps
  2. Path: sparky!uunet!munnari.oz.au!mel.dit.csiro.au!dmp.csiro.au!lachlan
  3. From: lachlan@dmp.csiro.au (Lachlan Cranswick)
  4. Subject: Re: Scientific graphic for Windows ?
  5. Message-ID: <1993Jan1.065005.20838@dmp.csiro.au>
  6. Organization: CSIRO Division of Mineral Products, Melbourne, AUSTRALIA
  7. References: <1001@rc1.vub.ac.be> <29DEC199212493521@moose.cccs.umn.edu>,<1992Dec30.140257.7379@dmp.csiro.au> <00965EB8.C9E638A0@vms.csd.mu.edu>
  8. Date: Fri, 1 Jan 1993 06:50:05 GMT
  9. Lines: 75
  10.  
  11. 5916rahmank@vms.csd.mu.edu ( ) writes:
  12.  
  13. >In article <1992Dec30.140257.7379@dmp.csiro.au>, lachlan@dmp.csiro.au (Lachlan Cranswick) writes:
  14. >    .... deletion....
  15. >>
  16. >>Lachlan.
  17. >>-- 
  18. >>  Lachlan Cranswick  -  CSIRO             _--_|\  lachlan@dmp.CSIRO.AU
  19. >>  Division of Mineral Products           /      \ tel +61 3 647 0367
  20. >>  PO Box 124, Port Melbourne 3207        \_.--._/ fax +61 3 646 3223
  21. >>  AUSTRALIA                                    v 
  22. >-------------------------------------------------------------
  23. >    I have a question on sigma plot for dos. I have set the axis 
  24. >    label to scientific notation format. What it does, it puts 
  25. >    three digit exponents, i.e., for example, 2.3e+007. I couldn't
  26. >    find a way to make it a two digit exponent like 2.3e+07. Can
  27. >    somebody show me how to do it.
  28.  
  29. >    Thank you.
  30.  
  31. >    -Anis.
  32.  
  33. Yes, I'm now a liar (well sort of)   when I said 
  34. SigmaPlot could control "everything" (I've not needed
  35. scientific notation before)
  36. I could not figure out how to do it elegantly via the menus
  37. BUT there is a way to do it that is a bit inelegant (via the menus).
  38.  
  39. In Tick label options, select "Text from columns x (say column 7).
  40.  
  41. In column 7, type out the labels as you would want them to
  42. appear on the graph.  Now the problem here (that took me
  43. an hour - it is 30 deg Celcius outside and 35deg Celcius in
  44. my room - so the pressure was on) is that Sigma plot thinks
  45. that 2.3e+02 (the numbers I was using) is numerical, not text,
  46. so it converted it to its standard format which gives you so much
  47. agro.
  48.  
  49. I forgot/don't know how to type numbers as text into the worksheet
  50. but the solution to this I found was to use 123 to make a wk1 file
  51. with the labels entered as text.  Import it into Sigma plot and
  52. it will now recognise the labels as text - and you should
  53. now see the labels on the graph as you want them.
  54. (You should be able to use any data format to inport
  55. the labels into sigma plot. )
  56.  
  57. There are probably better ways to do this but this
  58. is one way to do it at short notice.
  59.  
  60.  
  61. There is an email address and BBS for Jandel to get
  62. help/discuss problems.  I recieved it in a blurb from
  63. them around 6 months ago.  However, as I was really kicking heads
  64. in with this program (being a He-Man individaul) I threw it
  65. in the bin as I thought I would never need it.  Bit stupid
  66. I admit, as I now have a small query on batch printing.
  67. I'm printing over 200 graphs via batch with a cannon 10ex via
  68. EpsonLQ mode.  Half the graphs, before they are printed,
  69. keep prompting whether I want to Use, Cancel, Not Use the
  70. defaults in the graph.  The type of printer is irrelevant, and 
  71. the message prompt is irrelevant to what is printed
  72. out, but means I have to stay by the printer.  I think it may
  73. have something to do with the original graphs were in
  74. SigmaPlot 4.1 format?
  75.  
  76. If you need anymore help, send me email.
  77.  
  78. Hopefully, my reputation (or lack of it) is
  79. still intact.  Happy New Year to all,  Lachlan.
  80.  
  81. -- 
  82.   Lachlan Cranswick  -  CSIRO             _--_|\  lachlan@dmp.CSIRO.AU
  83.   Division of Mineral Products           /      \ tel +61 3 647 0367
  84.   PO Box 124, Port Melbourne 3207        \_.--._/ fax +61 3 646 3223
  85.   AUSTRALIA                                    v 
  86.