home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #30 / NN_1992_30.iso / spool / vmsnet / pdp11 / 904 < prev    next >
Encoding:
Text File  |  1992-12-21  |  1.8 KB  |  43 lines

  1. Newsgroups: vmsnet.pdp-11
  2. Path: sparky!uunet!zaphod.mps.ohio-state.edu!caen!batcomputer!cornell!newsstand.cit.cornell.edu!news
  3. From: Jeffrey Luszcz <jrl2@cornell.edu>
  4. Subject: Re: Qbus SMD drive question, Kennedy 5300 and Emulex SC02/A
  5. Message-ID: <1992Dec18.201423.20796@mail.cornell.edu>
  6. X-Xxdate: Fri, 18 Dec 92 20: 17:50 GMT
  7. Sender: news@mail.cornell.edu
  8. Nntp-Posting-Host: bradford.cit.cornell.edu
  9. Nntp-Posting-User: jrl2@cornell.edu
  10. Organization: Cornell University
  11. X-Useragent: Nuntius v1.1.1d7
  12. References: <CMM.0.90.0.724409822.bqt@Bern.DoCS.UU.SE> <BzFu2G.61r@world.std.com>
  13. Date: Fri, 18 Dec 1992 20:14:23 GMT
  14. Lines: 27
  15.  
  16.  
  17. Megan B Gentry, mbg@world.std.com writes:
  18. >I checked the sources and they do twiddle the hardware directly.  The
  19. >RP device you're using may not emulate an RP02/03 exactly.
  20. >
  21. >What version of RT are you using?
  22. >
  23. >                    Megan
  24. >
  25.  
  26.   I figured out what the problem was, a non-functioning dip-switch.
  27. Even though the board was set correctly, it didn't think it was.
  28. So I went through and switched all the switches back and forth
  29. and then reset it up correctly. I put it in and was able to get the
  30. onboard formatter to work. Yeehh!
  31.   Megan is right, the FMT command will not work on this emulation.
  32. but since the board has an onboard formatter, I'm set. Richard
  33. Chapman who is also using a Kennedy  5300 is out of luck though.
  34. After I got the board working he tried it with his 5300 and was
  35. able to format it, but the Dilog DU202 he is using won't recognized
  36. its format scheme. So he called Dilog, they want $250US for a 
  37. formatting utility.  Woah. 