- Newsgroups: comp.sys.mips
- Path: sparky!uunet!uunet.ca!mitra!larry
- From: larry@shark.mitra.com (Larry Williamson)
- Subject: 2030 won't boot, IOP diagnostics hang
- Message-ID: <LARRY.92Dec14085609@shark.mitra.com>
- Sender: larry@mitra.com (Larry Williamson)
- Organization: Mitra Imaging Inc.
- Date: Mon, 14 Dec 1992 13:56:09 GMT
- Lines: 20
-
-
- We have an old 2030 that has not worked for a long time. I pulled it
- out of the cabinet the other day to see if we can get anything out of
- it.
-
- When turned on, the internal hex display counts from 0 up to F, then
- wraps around to 1 and hangs. (I'm not sure if it ever displays F or
- the following 0, but it does count up once and only once).
-
- No message is display on the monitor connected to tty1.
-
- All three keyboard leds remain on.
-
- The machine has no disk drives installed. It has an 8 bit colour
- display adapter installed and 16 Meg of ram.
-
- Does anyone have any suggestions? (pitching the machine is a valid
- suggestion :-).
-
- -Larry
-